PRIMERGY RX100 S6 Server

Size: px
Start display at page:

Download "PRIMERGY RX100 S6 Server"

Transcription

1 Options Guide - English PRIMERGY RX100 S6 Server Options Guide Edition June 2012

2 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by to Certified documentation according to DIN EN ISO 9001:2008 To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001:2008. cognitas. Gesellschaft für Technik-Dokumentation mbh Copyright and Trademarks Copyright 2011 Fujitsu Technology Solutions GmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers. The contents of this manual may be revised without prior notice. Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. No part of this manual may be reproduced in any form without the prior written permission of Fujitsu. Microsoft, Windows, Windows Server, and Hyper V are trademarks or registered trademarks of Microsoft Corporation in the USA and other countries. Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the USA and other countries.

3 Before reading this manual For your safety This manual contains important information for safely and correctly using this product. Carefully read the manual before using this product. Pay particular attention to the accompanying manual "Safety Notes and Regulations" and ensure these safety notes are understood before using the product. Keep this manual and the manual "Safety Notes and Regulations" in a safe place for easy reference while using this product. Radio interference This product is a "Class A" ITE (Information Technology Equipment). In a domestic environment this product may cause radio interference, in which case the user may be required to take appropriate measures. VCCI-A Aluminum electrolytic capacitors The aluminum electrolytic capacitors used in the product's printed circuit board assemblies and in the mouse and keyboard are limited-life components. Use of these components beyond their operating life may result in electrolyte leakage or depletion, potentially causing emission of foul odor or smoke. As a guideline, in a normal office environment (25 C) operating life is not expected to be reached within the maintenance support period (5 years). However, operating life may be reached more quickly if, for example, the product is used in a hot environment. The customer shall bear the cost of replacing replaceable components which have exceeded their operating life. Note that these are only guidelines, and do not constitute a guarantee of trouble-free operation during the maintenance support period. High safety use This product has been designed and manufactured for general uses such as general office use, personal use, domestic use and normal industrial use. It has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk to life or body if such safety cannot be ensured. RX100 S6 Options Guide

4 These uses include control of nuclear reactions in nuclear power plants, automatic airplane flight control, air traffic control, traffic control in mass transport systems, medical devices for life support, and missile guidance control in weapons systems (hereafter, "high safety use"). Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this product for high safety use. Measures against momentary voltage drop This product may be affected by a momentary voltage drop in the power supply caused by lightning. To prevent a momentary voltage drop, use of an AC uninterruptible power supply is recommended. (This notice follows the guidelines of Voltage Dip Immunity of Personal Computer issued by JEITA, the Japan Electronics and Information Technology Industries Association.) Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan. Documents which contain such technology should not be exported from Japan or transferred to non-residents of Japan without first obtaining authorization in accordance with the above law. Harmonic Current Standards This product conforms to harmonic current standard JIS C Only for the Japanese market: About SATA hard disk drives The SATA version of this server supports hard disk drives with SATA / BC-SATA storage interfaces. Please note that the usage and operation conditions differ depending on the type of hard disk drive used. Please refer to the following internet address for further information on the usage and operation conditions of each available type of hard disk drive: Options Guide RX100 S6

5 Only for the Japanese market: I Although described in this manual, some sections do not apply to the Japanese market. These options and routines include: USB Flash Module (UFM) CSS (Customer Self Service) RX100 S6 Options Guide

6 Options Guide RX100 S6

7 Contents 1 Introduction Concept and target groups Documentation overview Expansions and conversions Notational conventions Procedure Safety instructions Preparation Opening the server Main memory Population rules Expanding the main memory Accessible drives and LSP Installing an accessible 5.25-inch slimline drive Installing a LSP Expansion cards and BBU Installing an expansion card Installing a BBU RX100 S6 Options Guide

8 Contents 8 Further options Front VGA module TPM USB Flash Module (UFM) Completion Closing the server Appendix Cabling Index Options Guide RX100 S6

9 1 Introduction The PRIMERGY RX100 S6 server is an Intel-based server for small and medium-sized networks and can be used in the rack systems made by Fujitsu and in current standard rack systems made by various other manufacturers. Security functions in the BIOS Setup and on the system board protect the data on the server against manipulation. Additional security is provided by the lockable rack door. The server occupies 1 height units (HU) in the rack. 1.1 Concept and target groups This Options Guide shows you how to extend and upgrade your server. V CAUTION! The activities described in this manual may only be performed by technical specialists. I The installation and removal of the hot-plug components is described in the Operating Manual supplied with the server. 1.2 Documentation overview More information on your PRIMERGY RX100 S6 can be found in the following documents: "Quick Start Hardware - PRIMERGY RX100 S6" leaflet " はじめにお読みください -PRIMERGY RX100 S6" for the Japanese market (only included as a printed copy) "Quick Start Software - Quick Installation Guide" DVD booklet (only included with the ServerView Suite as a printed copy) except for the Japanese market "Safety Notes and Regulations" manual " 安全上のご注意 " for the Japanese market "Warranty" manual " 保証書 " for the Japanese market RX100 S6 Options Guide 9

10 Documentation overview "ServerView Suite Local Service Concept - LSC" manual "Returning used devices" manual and "Service Desk" leaflet " サポート & サービス " for the Japanese market "PRIMERGY RX100 S6 Server Operating Manual" "PRIMERGY RX100 S6 Server Options Guide" "System Board D2863 for PRIMERGY RX100 S6 Technical Manual" BIOS Setup Utility for RX100 S6 manual I PRIMERGY manuals are available in PDF format on the ServerView Suite DVD 2. The ServerView Suite DVD 2 is part of the ServerView Suite supplied with every server. If you no longer have the ServerView Suite DVDs, you can obtain the relevant current versions using the order number U15000-C289 (the order number for the Japanese market: please refer to the configurator of the server The PDF files of the manuals can also be downloaded free of charge from the Internet. The overview page showing the online documentation available on the Internet can be found using the URL (for EMEA market): The PRIMERGY server documentation can be accessed using the Industry standard servers navigation option. For the Japanese market please use the URL: Further sources of information: PRIMERGY Abbreviations and Glossary on the ServerView Suite DVD 2 Manual for the monitor Documentation for the boards and drives Operating system documentation Information files in your operating system 10 Options Guide RX100 S6

11 Expansions and conversions 1.3 Expansions and conversions Main memory There are four slots for main memory to be used for UDIMM (unbuffered DIMM) or RDIMM (registered DIMM) memory modules. Mixing both types of memory modules is forbidden. RDIMM memory modules are configurable for Xeon CPUs only. Accessible drives One 5.25-inch slimline bay is available for an optical drive. LSP The system board supports the CSS (Customer Self Service) functionality (description see the operating manual). You can install a ServerView Local Service Panel (LSP) for an easier identification of the defective components. I There is only one 3.5-inch bay. You can install either a LSP or a Front VGA module. Additional expansion cards in the PCI slots With two riser cards, the system board offers 2 x PCI Express x8 slots and 1x PCI Express x4 slot. BBU You can install one Battery Backup Unit (BBU). Front VGA module The server can be equipped with a Front VGA module. This module offers one video (VGA) and one USB connector at the server s front side. I There is only one 3.5-inch bay. You can install either a LSP or a Front VGA module. Trusted Platform Module (TPM) The server can be equipped with a TPM (Trusted Platform Module). This module enables programs from third party manufacturers to store key information. RX100 S6 Options Guide 11

12 Notational conventions USB Flash Module (UFM) The server can be equipped with a USB Flash Module (UFM). This module can be used as optional memory for software (e.g. VMware) or as a software dongle. 1.4 Notational conventions The following notational conventions are used in this manual: Text in italics "Quotation marks" V CAUTION! I indicates commands or menu items. indicate names of chapters and terms that are being emphasized. describes activities that must be performed in the order shown. pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data. indicates additional information, notes and tips. 12 Options Guide RX100 S6

13 2 Procedure V CAUTION! The actions described in this manual shall be performed by technical specialists. A technical specialist is a person who is trained to install the server including hardware and software. Repairs to the device that do not relate to CSS failures shall be performed by service personnel. Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability. Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) or damage the equipment. First of all, carefully read the safety instructions in the chapter "Safety instructions" on page 15. Make sure that all necessary manuals (see the section "Documentation overview" on page 9) are available; print the PDF files if required. Most importantly, you will need the Operating Manual for the server and the Technical Manual for the system board. Shut the server down correctly, switch it off, disconnect the power cords and open the server as described in the chapter "Preparation" on page 23. Carry out the expansion or upgrade of your server as described in the pertinent chapter. I Installation and removal of the hot-plug components are described in the Operating Manual. Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 63. Start the operating system and make the appropriate configuration if necessary (see the Operating Manual). I For the latest information on optional products provided for the RX100 S6 see the configurator of this server: RX100 S6 Options Guide 13

14 Procedure 14 Options Guide RX100 S6

15 3 Safety instructions I The following safety instructions are also provided in the manual "Safety Notes and Regulations". This device meets the relevant safety regulations for IT equipment. If you have any questions about whether you can install the server in the intended environment, please contact your sales outlet or our customer service team. V CAUTION! The actions described in this manual shall be performed by technical specialists. A technical specialist is a person who is trained to install the server including hardware and software. Repairs to the device that do not relate to CSS failures shall be performed by service personnel. Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability. Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) or damage the equipment. Before installing/removing internal options to/from the server, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cords from the power outlet. Failure to do so can cause electric shock. RX100 S6 Options Guide 15

16 Safety instructions Before starting up V CAUTION! During installation and before operating the device, observe the instructions on environmental conditions for your device. If the device is brought in from a cold environment, condensation may form both inside and on the outside of the device. Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the device if this requirement is not observed. Transport the device only in the original packaging or in packaging that protects it from knocks and jolts. Installation and operation V CAUTION! This unit should not be operated in ambient temperatures above 35 C. If the unit is integrated into an installation that draws power from an industrial power supply network with an IEC309 connector, the power supply's fuse protection must comply with the requirements for nonindustrial power supply networks for type A connectors. The unit automatically adjusts itself to a mains voltage in a range of 100 V V or 200 V V. Ensure that the local mains voltage lies within these limits. This device must only be connected to properly grounded power outlets or insulated sockets of the rack's internal power supply with tested and approved power cords. Ensure that the device is connected to a properly grounded power outlet close to the device. 16 Options Guide RX100 S6

17 Safety instructions V CAUTION! Ensure that the power sockets on the device and the properly grounded power outlets are freely accessible. The On/Off button or the main power switch (if present) does not isolate the device from the mains power supply. To disconnect it completely from the mains power supply, unplug all network power plugs from the properly grounded power outlets. Always connect the server and the attached peripherals to the same power circuit. Otherwise you run the risk of losing data if, for example, the server is still running but a peripheral device (e.g. memory subsystem) fails during a power outage. Data cables must be adequately shielded. Ethernet cabling has to comply with EN and EN /2 standards or ISO/IEC standard respectively. The minimum requirement is a Category 5 shielded cable for 10/100 Ethernet, or a Category 5e cable for Gigabit Ethernet. Route the cables in such a way that they do not create a potential hazard (make sure no-one can trip over them) and that they cannot be damaged. When connecting the server, refer to the relevant instructions in this manual. Never connect or disconnect data transmission lines during a storm (risk of lightning hazard). Make sure that no objects (e.g. jewelry, paperclips etc.) or liquids can get inside the server (risk of electric shock, short circuit). In emergencies (e.g. damaged casing, controls or cables, penetration of liquids or foreign bodies), switch off the server immediately, remove all power plugs and contact your sales outlet or customer service team. RX100 S6 Options Guide 17

18 Safety instructions V CAUTION! Proper operation of the system (in accordance with IEC /2 resp. EN /2) is only ensured if the casing is completely assembled and the rear covers for the installation slots have been fitted (electric shock, cooling, fire protection, interference suppression). Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and those relating to telecommunication terminals. If you install other expansions, they may damage the system or violate the safety regulations. Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet. The components marked with a warning notice (e.g. lightning symbol) may only be opened, removed or exchanged by authorized, qualified personnel. Exception: CSS components can be replaced. The warranty is void if the server is damaged during installation or replacement of system expansions. Only set screen resolutions and refresh rates that are specified in the operating manual for the monitor. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service center. Before installing/removing internal options to/from the server, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cords from the outlet. Failure to do so can cause electric shock. Do not damage or modify internal cables or devices. Doing so may cause a device failure, fire, or electric shock. Devices inside the server remain hot after shutdown. Wait for a while after shutdown before installing or removing internal options. The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity. Before handling them, first touch a metal part of the server to discharge static electricity from your body. Do not touch the circuitry on boards or soldered parts. Hold the metallic areas or the edges of the circuit boards. 18 Options Guide RX100 S6

19 Safety instructions V CAUTION! Install the screw removed during installation/detaching Internal Options in former device/position. To use a screw of the different kind causes a breakdown of equipment. The installation indicated on this note is sometimes changed to the kind of possible options without notice. Batteries V CAUTION! Incorrect replacement of batteries may result in a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the Technical Manual for the system board). Replace the lithium battery on the system board in accordance with the instructions in the Technical Manual for the system board. RX100 S6 Options Guide 19

20 Safety instructions Working with CDs/DVDs/BDs and optical drives When working with devices with optical drives, these instructions must be followed. V CAUTION! Only use CDs/DVDs/BDs that are in perfect condition, in order to prevent data loss, equipment damage and injury. Check each CD/DVD/BD for damage, cracks, breakages etc. before inserting it in the drive. Note that any additional labels applied may change the mechanical properties of a CD/DVD/BD and cause imbalance. Damaged and imbalanced CDs/DVDs/BDs can break at high drive speeds (data loss). Under certain circumstances, sharp CD/DVD/BD fragments can pierce the cover of the optical drive (equipment damage) and can fly out of the device (danger of injury, particularly to uncovered body parts such as the face or neck). High humidity and airborne dust levels are to be avoided. Electric shocks and/or server failures may be caused by liquids such as water, or metallic items, such as paper clips, entering a drive. Shocks and vibrations are also to be avoided. Do not insert any objects other than the specified CDs/DVDs/BDs. Do not pull on, press hard, or otherwise handle the CD/DVD/BD tray roughly. Do not disassemble the optical drive. Before use, clean the optical disk tray using a soft, dry cloth. As a precaution, remove disks from the optical drive when the drive is not to be used for a long time. Keep the optical disk tray closed to prevent foreign matter, such as dust, from entering the optical drive. Hold CDs/DVDs/BDs by their edges to avoid contact with the disk surface. 20 Options Guide RX100 S6

21 Safety instructions Do not contaminate the CD/DVD/BD surface with fingerprints, oil, dust, etc. If dirty, clean with a soft, dry cloth, wiping from the center to the edge. Do not use benzene, thinners, water, record sprays, antistatic agents, or silicone-impregnated cloth. Be careful not to damage the CD/DVD/BD surface. Keep the CDs/DVDs/BDs away from heat sources. Do not bend or place heavy objects on CDs/DVDs/BDs. Do not write with ballpoint pen or pencil on the label (printed) side. Do not attach stickers or similar to the label side. Doing so may cause rotational eccentricity and abnormal vibrations. When a CD/DVD/BD is moved from a cold place to a warm place, moisture condensation on the CD/DVD/BD surface can cause data read errors. In this case, wipe the CD/DVD/BD with a soft, dry cloth then let it air dry. Do not dry the CD/DVD/BD using devices such as a hair dryer. To avoid dust, damage, and deformation, keep the CD/DVD/BD in its case whenever it is not in use. Do not store CDs/DVDs/BDs at high temperatures. Areas exposed to prolonged direct sunlight or near heating appliances are to be avoided. I You can prevent damage from the optical drive and the CDs/DVDs/BDs, as well as premature wear of the disks, by observing the following suggestions: Only insert disks in the drive when needed and remove them after use. Store the disks in suitable sleeves. Protect the disks from exposure to heat and direct sunlight. Laser information The optical drive complies with IEC laser class 1. V CAUTION! The optical drive contains a light-emitting diode (LED), which under certain circumstances produces a laser beam stronger than laser class 1. Looking directly at this beam is dangerous. Never remove parts of the optical drive casing! RX100 S6 Options Guide 21

22 Safety instructions Modules with Electrostatic-Sensitive Devices Modules with electrostatic-sensitive devices are identified by the following sticker: Figure 1: ESD label When you handle components fitted with ESDs, you must always observe the following points: Switch off the system and remove the power plugs from the power outlets before installing or removing components with ESDs. You must always discharge static build-up (e.g. by touching a grounded object) before working with such components. Any devices or tools that are used must be free of electrostatic charge. Wear a suitable grounding cable that connects you to the external chassis of the system unit. Always hold components with ESDs at the edges or at the points marked green (touch points). Do not touch any connectors or conduction paths on an ESD. Place all the components on a pad which is free of electrostatic charge. I For a detailed description of how to handle ESD components, see the relevant European or international standards (EN , ANSI/ESD S20.20). 22 Options Guide RX100 S6

23 4 Preparation V CAUTION! Before removing or attaching covers, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cables from the outlet. Failure to do so can cause electric shock. Only for rack model: Use the anti-tilt plate to prevent the rack from tipping when installing the rack. Pulling the server out of the rack without having installed the anti-tilt plate may cause the rack to tip over. Only for rack model: Be careful not to pinch fingers or clothes when sliding out the server or pushing it back. Failure to do so may cause injury. Before attaching the cover, make sure no unnecessary parts or tools are left inside the server. Before turning on the server, make sure the cover is closed. Follow the safety instructions in the chapter "Safety instructions" on page Opening the server Exit all applications and shut down the server properly. Press the On/Off button if the server has not been switched off by the operating system. Pull all power connectors out of the power outlets. Disconnect all cables on the rear of the server. RX100 S6 Options Guide 23

24 Opening the server Figure 2: Pulling the server out of the rack Unscrew the two knurled screws (1). Pull the server as far as it will go out of the rack (2). Release the locking mechanism (a or b) of both rails (3). Pull the server carefully out of the rails and place it on a flat support. Figure 3: Loosening the two knurled screws Unlock the top cover by removing the two knurled screws at the rear side (1). 24 Options Guide RX100 S6

25 Opening the server Figure 4: Removing the top cover Push the top cover as far as it will go in the direction of the arrow (1). Lift off the top cover upward (2). RX100 S6 Options Guide 25

26 Opening the server 26 Options Guide RX100 S6

27 5 Main memory V CAUTION! Before installing/removing memory to/from the server, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cables from the outlet. Failure to do so can cause electric shock. A memory module consists of parts that are very vulnerable to damage by static electricity, and can easily be damaged by static electricity in the human body. Before handling memory modules, first touch a metal part of the server to discharge static electricity. Do not touch the circuitry on boards and soldered parts. Hold the metallic areas or the edge of the circuit boards. Do not install unauthorized third party memory modules. Doing so may cause electric shock, a fire, or failures. Wait for a sufficient period of time after server shutdown before installing or removing memory modules. Failure to do so may cause burns. When installing or removing memory modules, make sure to remove the screws at the specified points only. Failure to do so may cause injury. It may also cause failures. Touch only the specified part of the printed circuit board. Failure to do so may cause injury. It may also cause failures. Do not insert and remove memory modules repeatedly. Doing so may cause failures. If the memory module has not been correctly inserted, it may cause a fire. Insert the memory module with attention to its direction. If a memory module is installed and you pull the securing clips strongly outward, the memory module pops up. Doing so may cause a device failure. Follow the safety instructions in the chapter "Safety instructions" on page 15. RX100 S6 Options Guide 27

28 Population rules 5.1 Population rules There are four slots for main memory. DIMM 2A DIMM 1A DIMM 2B DIMM 1B Figure 5: Slots of the main memory Memory slot 1 / channel A (DIMM 1A) needs to be populated first. Quad rank (QR) memory modules must be populated first in DIMM 1A, in case of usage memory modules with different ranks (SR/DR + QR). Within all channels memory slot 1 must be populated prior to slot 2. Install memory modules within a channel in descending order of capacity: higher capacity in slot 1, lower capacity in slot 2. Mixing of RDIMM and UDIMM is not allowed. 28 Options Guide RX100 S6

29 Population rules RDIMM memory modules Technology: Total memory size: DDR / 1333 buffered single rank (SR), dual rank (DR) or quad rank (QR) RDIMM memory modules with ECC. Support for up to 4 RDIMM memory modules. RDIMM memory modules are only supported by Intel Quad-Core processors (Xeon 3400 series). up to 32 GB Configuration per Max. speed DIMM-2 DIMM-1 channel 1 DDR empty SR/DR 2 DDR empty QR 3 DDR SR/DR SR/DR 4 DDR3-800 QR QR UDIMM memory modules Technology: Total memory size: DDR unbuffered single rank (SR) or dual rank (DR) UDIMM memory modules with ECC. Support for up to 4 UDIMM memory modules. UDIMM memory modules are supported by Intel Dual- Core processors (e.g. Core i3-540, Pentium G6950, Celeron G1101) and by Intel Quad-Core processors (Xeon 3400 series). up to 16 GB Configuration per Max. speed DIMM-2 DIMM-1 channel 1 DDR empty SR/DR 2 DDR SR/DR SR/DR RX100 S6 Options Guide 29

30 Expanding the main memory 5.2 Expanding the main memory Open the server as described in the chapter "Preparation" on page 23. Figure 6: Opening the securing clips Press the securing clips on both sides of the memory slot concerned outward (1). Figure 7: Installing a memory module Carefully press the memory module into the slot (1) until the securing clips on both sides of it engage (2). Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page Options Guide RX100 S6

31 6 Accessible drives and LSP V CAUTION! Before installing/removing an accessible drive to/from the server, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cables from the outlet. Failure to do so can cause electric shock. When installing an accessible drive, hold it by the side. Applying force to the top may cause failures. Do not touch the circuitry on boards and soldered parts. Hold the metallic areas or the edge of the circuit boards. The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity. Before handling them, first touch a metal part on the server to discharge static electricity from your body. Before installing an internal accessible drive, see the manual for the accessible drive. When forcing an accessible drive into a server, be careful so as not to pinch the cable etc. connected to an accessible drive. Follow the safety instructions in the chapter "Safety instructions" on page 15. RX100 S6 Options Guide 31

32 Installing an accessible 5.25-inch slimline drive 6.1 Installing an accessible 5.25-inch slimline drive Open the server as described in the chapter "Preparation" on page 23. Figure 8: Removing the dummy cover (bottom side) Pull the dummy cover out of the bay (1). V CAUTION! Keep the dummy cover for future use. If you remove the accessible drive again and do not replace it with a new one, the dummy cover must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures. Figure 9: Removing the retaining spring from the dummy cover Remove the two screws (1). Pull the retaining spring out of the dummy cover (2). 32 Options Guide RX100 S6

33 Installing an accessible 5.25-inch slimline drive Figure 10: Installing the retaining spring Fasten the retaining spring with two screws to the rear side of the accessible drive. Figure 11: Installing the accessible drive Push the accessible drive into the bay (1) simultanously pressing the front of the drive slightly down until the retaining spring engages (2). RX100 S6 Options Guide 33

34 Installing an accessible 5.25-inch slimline drive Figure 12: Connecting the cables Connect the power cable (1) to the accessible drive (see the cabling plans in the Appendix). Connect the data cable (2) to the SATA connector on the accessible drive (see the cabling plans in the Appendix). Figure 13: Connecting the SATA cable to the system board Thread the SATA cable through the openings (1). Connect the SATA cable (2) to the system board (see the cabling plans in the Appendix). Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page Options Guide RX100 S6

35 Installing a LSP 6.2 Installing a LSP I There is only one 3.5-inch bay. You can install either a LSP or a Front VGA module. Open the server as described in the chapter "Preparation" on page 23. Figure 14: Disengaging the dummy module Press the locking mechanism down. RX100 S6 Options Guide 35

36 Installing a LSP Figure 15: Removing the dummy module Push the dummy module frontward and out of the bay. V CAUTION! Keep the dummy module for future use. If the LSP is removed again and not replaced with a new one, then the dummy module must be reinstalled due to cooling, the applicable EMC regulations (regulations on electromagnetic compatibility) and fire protection. 36 Options Guide RX100 S6

37 Installing a LSP Figure 16: LSP Figure 17: Installing the LSP Push the LSP into the bay from the front until the locking mechanism engages. RX100 S6 Options Guide 37

38 Installing a LSP Figure 18: Connecting the LSP cable to the LSP Thread the LSP cable through the openings (1). Connect the LSP cable (2) to the LSP (see the cabling plans in the Appendix). Figure 19: Connecting the LSP cable to the system board Plug the LSP cable into the SMBus LSP connector on the system board (see the cabling plans in the Appendix). Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page Options Guide RX100 S6

39 7 Expansion cards and BBU V CAUTION! Before installing/removing expansion cards to/from the server, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cables from the outlet. Failure to do so can cause electric shock. The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity. Before handling them, first touch a metal part on the server to discharge static electricity from your body. Do not touch the circuitry on boards and soldered parts. Hold the metallic areas or the edge of the circuit boards. Follow the safety instructions in the chapter "Safety instructions" on page 15. RX100 S6 Options Guide 39

40 Installing an expansion card 7.1 Installing an expansion card With two riser cards, the system board offers 2 x PCI Express x8 slots and 1x PCI Express x4 slot. Preferred slots Riser card PCI bus Slots / slots no. Length S26361-E402-A10 PCIe x8 1 slot / 1 standard or low-profile PCIe x8 slot, maximum length 175 mm S26361-E403-A10 PCIe x8 1 slot / 2 low-profile PCIe x8 slot, maximum length 170 mm PCIe x4 (mech. x8) 1 slot / 3 PCIe x4 slot (mech. x8), only for modular RAID Start installing expansion cards from slot 1. If slot 1 is already occupied, please use slot 2. Slot 3 is reserved for RAID controller only. 1. Controller for special slots Nvidia NVS290 S26361-F2748-E63 (only when slot 3 is empty) Intel 10 Gigabit XF SR Dual Port S26361-F3555-E201 (Spring Fountain) FSC S26361-D2607-A** (if boot controller) FSC S26361-D2616-A** (if boot controller) FSC S26361-D2507-A** (if boot controller) FSC S26361-D2516-A** (if boot controller) PCI bus type Max pcs per system Slot no , , , , , ,2 Forbidden slot 40 Options Guide RX100 S6

41 Installing an expansion card 2. PCI-Express x4 controller MegaRAID SAS9280-8e 6Gb/s Intel Pro 1000PT Quad Port Server Adapter LP S26361-F3462-E201 (Kirkwood 2) Intel Pro/1000PT dual Server Adapter S26361-F3228-E201 (Redwater) Intel PRO/1000 PF Server Adapter S26361-F3242-E201 (Sheepshead Bay) PCI bus type Max pcs per system Slot no GB/s GB/s Forbidden slot 3. PCI-Express x1 controller Adaptec SCSI Card ASC LPE S26361-F3270-E201 Intel Gigabit CT Desktop Adapter S26361-F3516-E201 (Shelter Island) Intel PRO/1000 PT Server Adapter S26361-F3241-E201 (Glyndon) PCI bus type Max pcs per system Slot no GB/s GB/s Forbidden slot RX100 S6 Options Guide 41

42 Installing an expansion card Riser module 1 Riser module 1 offers slot 1. Open the server as described in the chapter "Preparation" on page 23. Figure 20: Removing the riser module 1 Push the green lock bars of the riser module 1 in direction of the arrows (1). Carefully pull out the riser module 1 upward (2). Please read the documentation supplied with the expansion card. 42 Options Guide RX100 S6

43 Installing an expansion card Figure 21: Pulling out the slot cover - riser module 1 Pull out the slot cover frontward (1) and remove it sideward (2). V CAUTION! Keep the slot cover for future use. If the expansion card is removed and not replaced with a new card, the slot cover must be reinstalled due to cooling, to comply with applicable EMC regulations (regulations on electromagnetic compatibility) and to protect against fire. Figure 22: Removing the slot cover extension Loosen the screw (1) and remove the slot cover extension (2). RX100 S6 Options Guide 43

44 Installing an expansion card Figure 23: Attaching the slot cover extension to the expansion card Attach the slot cover extension to the slot cover of the expansion card (1). Fasten the slot cover extension with one screw (2). B A Figure 24: Installing an expansion card -slot 1 Carefully press the expansion card into the riser card slot (A), until it clicks into place (1). Make sure that the lug on the slot cover (B) clicks into place in the corresponding hole (2). 44 Options Guide RX100 S6

45 Installing an expansion card A Figure 25: Installing the riser module 1 Insert the riser card into the system board slot (1). Make sure that the two guiding bolts (A) at the right side of the riser holder engage correctly. Push the green lock bars of the riser module 1 in direction of the arrows (2). If necessary, connect the cables to the expansion card and the other components. Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 63. RX100 S6 Options Guide 45

46 Installing an expansion card Riser module 2 Riser module 2 offers slot 2 and slot 3. Open the server as described in the chapter "Preparation" on page 23. Figure 26: Removing the riser module 2 If necessary, remove the cables from the two cable clamps (1). Notice the cable routing. Carefully pull out the riser module 2 upward (2). Please read the documentation supplied with the expansion card. 46 Options Guide RX100 S6

47 Installing an expansion card Figure 27: Pulling out the slot cover - slot 2 Pull out the slot cover (1). V CAUTION! Keep the slot cover for future use. If the expansion card is removed and not replaced with a new card, the slot cover must be reinstalled due to cooling, to comply with applicable EMC regulations (regulations on electromagnetic compatibility) and to protect against fire. RX100 S6 Options Guide 47

48 Installing an expansion card A B Figure 28: Installing an expansion card -slot 2 Carefully press the expansion card into the riser card slot (A), until it clicks into place (1). Make sure that the lug on the slot cover (B) clicks into place in the corresponding hole (2). 48 Options Guide RX100 S6

49 Installing an expansion card Figure 29: Attaching the mounting bracket to an expansion card Attach the mounting bracket to the expansion card (1). Fasten the mounting bracket with two screws (2). A B Figure 30: Installing an expansion card - slot 3 Fit the hook on the riser card holder (B) into the retaining slot in the mounting bracket (1). Carefully press the expansion card into the riser card slot (A), until it clicks into place (2). RX100 S6 Options Guide 49

50 Installing an expansion card A Figure 31: Installing the riser module 2 Insert the riser card into the system board slot (1). Make sure that the two guiding bolts (A) of the riser holder engage correctly. If necessary, route the cables in the two cable clamps as before (2). If necessary, connect the cables to the expansion card and the other components. Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page Options Guide RX100 S6

51 Installing a BBU 7.2 Installing a BBU You can install one Battery Backup Unit (BBU). Open the server as described in the chapter "Preparation" on page 23. Figure 32: Removing two bolts from the BBU Loosen the two screws and remove the two bolts from the BBU. A Figure 33: Connecting the cable to the BBU Connect the BBU cable to the BBU. V CAUTION! Make sure that the connector side with two pin rows (A) is on the top. Otherwise you risk short-circuits. RX100 S6 Options Guide 51

52 Installing a BBU Figure 34: Position of the bolts and the foil A Figure 35: Fastening the BBU to the housing Position the BBU on the two bolts in the housing (1) with aligning the edges of the foil (A) and the BBU. Fasten the BBU to the bolts using two screws (2). 52 Options Guide RX100 S6

53 Installing a BBU Figure 36: Connecting BBU cable to controller Install a controller as described in the section "Installing an expansion card" on page 40. Connect the BBU cable to the controller. V CAUTION! Make sure that the connector side with two pin rows is on the top. Otherwise you risk short-circuits. Figure 37: Routing BBU cable Route the BBU cable as shown in the figure. Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 63. RX100 S6 Options Guide 53

54 Installing a BBU 54 Options Guide RX100 S6

55 8 Further options V CAUTION! Follow the safety instructions in chapter "Safety instructions" on page Front VGA module I There is only one 3.5-inch bay. You can install either a LSP or a Front VGA module. Open the server as described in the chapter "Preparation" on page 23. Remove the dummy module as described on page 35. Figure 38: Connecting cables to the Front VGA module Thread the two ends of the Front VGA cable through the top bay for accessible drives (1). Connect the USB connector (2) and the VGA connector (3) to the connectors of the Front VGA module. RX100 S6 Options Guide 55

56 Front VGA module Figure 39: Sliding in the Front VGA module Push the Front VGA module into the bay from the front (1). Thread the cable through the openings (2). Figure 40: Connecting the Front VGA cable to the system board Connect the Front VGA cable to the system board (see the cabling plans in the Appendix). Route the cable in the two cable clamps. Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page Options Guide RX100 S6

57 TPM 8.2 TPM The server can be equipped with a TPM (Trusted Platform Module). This module enables programs from third party manufacturers to store key information. Figure 41: TPM installation kit 1 TPM (Trusted Platform Module) 3 Special screw for TPM 2 TPM spacer I The black TPM spacer is not used in this server. 4 TPM screwdriver insert bit for TPM special screw Open the server as described in the chapter "Preparation" on page 23. Figure 42: Inserting the TPM spacer on the system board Insert the TPM spacer into the hole on the system board. RX100 S6 Options Guide 57

58 TPM Figure 43: Fastening the TPM Insert the TPM on the system board (1). Fasten the TPM with the special screw for the TPM (2). Please use the TPM screwdriver insert bit to tighten the special screw. I Do not fasten the screw too tightly (torque value of 0.6 Nm). Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page Options Guide RX100 S6

59 USB Flash Module (UFM) 8.3 USB Flash Module (UFM) The server can be equipped with a USB Flash Module (UFM). Figure 44: UFM installation kit Figure 45: UFM cable 1 USB Flash Module (UFM) 3 UFM spacer 2 UFM nylon screw 4 UFM cable RX100 S6 Options Guide 59

60 USB Flash Module (UFM) Open the server as described in the chapter "Preparation" on page 23. Figure 46: Preparing the UFM Remove the nylon screw from the UFM (1). Remove the UFM spacer (2). I The UFM spacer is no longer required. 60 Options Guide RX100 S6

61 USB Flash Module (UFM) Figure 47: Position of the bolts in the chassis Figure 48: Positioning the UFM Push the UFM between the two bolts (1) until the threaded bolt (2) engages in the screw hole. RX100 S6 Options Guide 61

62 USB Flash Module (UFM) Figure 49: Fastening the UFM Fasten the UFM with the nylon screw. Figure 50: Connecting the UFM cable Connect the UFM cable to the UFM (connector J2) and to the system board (connector J26). Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page Options Guide RX100 S6

63 9 Completion V CAUTION! Follow the safety instructions in chapter "Safety instructions" on page Closing the server Figure 51: Mounting the top cover Place the top cover on the server (1). Make sure that each bolt is positioned in the corresponding nut. Push the top cover as far as it will go in the direction of the arrow (2). RX100 S6 Options Guide 63

64 Closing the server Figure 52: Securing the two knurled screws Secure the top cover with the two knurled screws at the rear side (1). If you have not removed the server from the rack, skip the instructions for mounting in the rack: Figure 53: Inserting the server Extend the interior telescopic rails completely to the front (1). I They must click into place so that they can no longer be moved. 64 Options Guide RX100 S6

65 Closing the server Insert the prepared server into the protruding interior telescope rails (2) until the rails engage. Release the locking mechanism (a or b) of both rails (3). Push the server as far as it will go into the rack (4). Fasten the server to the rack (5) using the two knurled screws (front panel). Reconnect all the cables you disconnected beforehand on the rear of the server. Connect all power plugs to the power outlets. Press the on/off key to start up the server. RX100 S6 Options Guide 65

66 Closing the server 66 Options Guide RX100 S6

67 10 Appendix 10.1 Cabling No. Part number From -to 1 SNP:A3C System board to fans and ODD power 2 SNP:A3C System board to front panel 3 SNP:A3C System board to backplane 4 SNP:A3C System board to ODD data T26139-Y3958-V101 System board to ODD data I There is no problem even if it connects it with a yellow SATA connector though the color of the connector of T Y3958-V101 is different from SNP:A3C SNP:A3C System board to backplane (SATA only) 6 SNP:A3C System board to LSP 7 SNP:A3C System board to front VGA module 8 SNP:A3C System board to backplane (SATA only) 9 SNP:A3C System board to backplane (SATA only) 10 SNP: A3C RAID card to backplane 11 SNP:A3C RAID card to backplane 12 T26361-Y3987-V2 ibbu to RAID card RX100 S6 Options Guide 67

68 Appendix 2 Front panel 350W PSU HDD bay CPU HDD bay System fans 4 Slim ODD SNP:A3C SNP:A3C SNP:A3C T26139-Y3958-V101 Figure 54: Basic cabling 68 Options Guide RX100 S6

69 Appendix 2 Front panel 350W PSU 5 3 HDD bay CPU HDD bay 9 8 System fans 4 Backplane Slim ODD 1 1 SNP:A3C SNP:A3C SNP:A3C T26139-Y3958-V101 3 SNP:A3C SNP:A3C SNP:A3C SNP:A3C Figure 55: Cabling of the 2.5-inch SATA HDD variant RX100 S6 Options Guide 69

70 Appendix 2 Front panel 350W PSU 10 3 HDD bay CPU HDD bay 4 System fans 10 Backplane Slim ODD RAID card 1 ibbu 12 1 SNP:A3C SNP:A3C SNP:A3C T26139-Y3958-V101 3 SNP:A3C SNP:A3C T26361-Y3987-V2 Figure 56: Cabling of the 2.5-inch SAS HDD variant with ibbu 70 Options Guide RX100 S6

71 Appendix 2 Front panel 350W PSU 3 HDD bay 5 CPU HDD bay 8 System fans 4 Backplane Slim ODD 1 1 SNP:A3C SNP:A3C SNP:A3C T26139-Y3958-V101 3 SNP:A3C SNP:A3C SNP:A3C Figure 57: Cabling of the 3.5-inch SATA HDD variant RX100 S6 Options Guide 71

72 Appendix 2 Front panel 350W PSU 3 HDD bay 11 CPU HDD bay 4 System fans 11 Backplane Slim ODD RAID card 1 ibbu 12 1 SNP:A3C SNP:A3C SNP:A3C T26139-Y3958-V101 3 SNP:A3C SNP:A3C T26361-Y3987-V2 Figure 58: Cabling of the 3.5-inch SAS HDD variant with ibbu 72 Options Guide RX100 S6

73 Appendix 2 Front panel 350W PSU 3 HDD bay 5 CPU HDD bay System fans Backplane Front VGA module 1 SNP:A3C SNP:A3C SNP:A3C T26139-Y3958-V101 3 SNP:A3C SNP:A3C SNP:A3C SNP:A3C Figure 59: Cabling of the 3.5-inch SATA HDD variant with Front VGA module RX100 S6 Options Guide 73

74 Appendix 2 Front panel 350W PSU 3 HDD bay 5 CPU HDD bay System fans Backplane LSP 1 1 SNP:A3C SNP:A3C SNP:A3C T26139-Y3958-V101 3 SNP:A3C SNP:A3C SNP:A3C SNP:A3C Figure 60: Cabling of the 3.5-inch SATA HDD variant with LSP 74 Options Guide RX100 S6

PRIMERGY BX400 S1 System Unit

PRIMERGY BX400 S1 System Unit Options Guide - English PRIMERGY BX400 S1 System Unit Options Guide December 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

PRIMERGY TX120 S2 Server. Service Supplement

PRIMERGY TX120 S2 Server. Service Supplement PRIMERGY TX120 S2 Server Service Supplement Edition July 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY RX300 S6 Server

PRIMERGY RX300 S6 Server Options Guide - English PRIMERGY RX300 S6 Server Options Guide Edition October 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

Operating Manual - English. RDX USB 3.0 QuikStor Drive

Operating Manual - English. RDX USB 3.0 QuikStor Drive Operating Manual - English RDX USB 3.0 QuikStor Drive December 2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

PRIMERGY RX600 S5 Server

PRIMERGY RX600 S5 Server Service Supplement - English PRIMERGY RX600 S5 Server Service Supplement June 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

PRIMERGY TX150 S6 Server. Options Guide

PRIMERGY TX150 S6 Server. Options Guide PRIMERGY TX150 S6 Server Options Guide Edition June 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

FUJITSU Server PRIMERGY RX1330 M2

FUJITSU Server PRIMERGY RX1330 M2 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX1330 M2 Upgrade and Maintenance Manual December 2015 Comments Suggestions Corrections The User Documentation Department would like to

More information

PRIMERGY TX300 S6 Server

PRIMERGY TX300 S6 Server Service Supplement - English PRIMERGY TX300 S6 Server Service Supplement Edition March 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

PRIMERGY RX600 S5 Server

PRIMERGY RX600 S5 Server Options Guide - English PRIMERGY RX600 S5 Server Options Guide August 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback

More information

PRIMERGY BX922 S2 Server Blade

PRIMERGY BX922 S2 Server Blade Options Guide - us PRIMERGY BX922 S2 Server Blade Options Guide Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

FUJITSU Server PRIMERGY RX1330 M1

FUJITSU Server PRIMERGY RX1330 M1 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX1330 M1 Upgrade and Maintenance Manual August 2014 Comments Suggestions Corrections The User Documentation Department would like to know

More information

PRIMERGY TX200 S6 Server

PRIMERGY TX200 S6 Server Options Guide - English PRIMERGY TX200 S6 Server Options Guide Edition July 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

PRIMERGY TX300 S6 Server

PRIMERGY TX300 S6 Server Options Guide - English PRIMERGY TX300 S6 Server Options Guide Edition March 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

FUJITSU Server PRIMERGY TX1320 M3

FUJITSU Server PRIMERGY TX1320 M3 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY TX1320 M3 Upgrade and Maintenance Manual April 2017 Comments Suggestions Corrections The User Documentation Department would like to know

More information

PRIMERGY BX920 S3 Server Blade

PRIMERGY BX920 S3 Server Blade Upgrade and Maintenance Manual - English PRIMERGY BX920 S3 Server Blade Upgrade and Maintenance Manual Edition February 2014 Comments Suggestions Corrections The User Documentation Department would like

More information

PRIMERGY BX620 S6 Server Blade

PRIMERGY BX620 S6 Server Blade Service Supplement - English PRIMERGY BX620 S6 Server Blade Service Supplement September 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

FUJITSU Server PRIMERGY RX100 S8

FUJITSU Server PRIMERGY RX100 S8 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX100 S8 Upgrade and Maintenance Manual April 2015 Comments Suggestions Corrections The User Documentation Department would like to know

More information

FUJITSU Server PRIMERGY RX1330 M3

FUJITSU Server PRIMERGY RX1330 M3 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX1330 M3 Upgrade and Maintenance Manual April 2017 Comments Suggestions Corrections The User Documentation Department would like to know

More information

FUJITSU Server PRIMERGY RX2510 M2

FUJITSU Server PRIMERGY RX2510 M2 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX2510 M2 Upgrade and Maintenance Manual June 2017 Comments Suggestions Corrections The User Documentation Department would like to know

More information

PRIMERGY MX130 S2 Server

PRIMERGY MX130 S2 Server Upgrade and Maintenance Manual - English PRIMERGY MX130 S2 Server Upgrade and Maintenance Manual Edition November 2011 Comments Suggestions Corrections The User Documentation Department would like to know

More information

PRIMERGY CX400 S1 Server Enclosure

PRIMERGY CX400 S1 Server Enclosure Upgrade and Maintenance Manual - English PRIMERGY CX400 S1 Server Enclosure Upgrade and Maintenance Manual Edition December 2012 Comments Suggestions Corrections The User Documentation Department would

More information

PRIMERGY RX300 S4. Options Guide

PRIMERGY RX300 S4. Options Guide PRIMERGY RX300 S4 Options Guide Edition June 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our

More information

PRIMERGY RX300 S5. Service Supplement

PRIMERGY RX300 S5. Service Supplement PRIMERGY RX300 S5 Service Supplement Edition June 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY RX100 S6 Server. Service Supplement

PRIMERGY RX100 S6 Server. Service Supplement PRIMERGY RX100 S6 Server Service Supplement Edition january 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

PRIMERGY CX400 S2 Server Enclosure

PRIMERGY CX400 S2 Server Enclosure Operating Manual - English PRIMERGY CX400 S2 Server Enclosure Operating Manual Edition December 2013 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of

More information

PRIMERGY RX100 S7 Server

PRIMERGY RX100 S7 Server Operating Manual - English PRIMERGY RX100 S7 Server Operating Manual Edition June 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

PRIMERGY RX300 S2 Server System

PRIMERGY RX300 S2 Server System PRIMERGY PRIMERGY RX300 S2 Server System Monika Spanjaart Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001160 Fax: (++49) 700 / 372 00000

More information

PRIMERGY TX300 S4. Options Guide

PRIMERGY TX300 S4. Options Guide PRIMERGY TX300 S4 Options Guide Edition April 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our

More information

HP ProLiant DL165 G7 Server

HP ProLiant DL165 G7 Server HP ProLiant DL165 G7 Server Installation Instructions Part Number 601464-003 Identifying server components Front panel components Figure 1 Front Panel Components / 4 3.5 LFF HDD Item Description 1 Thumbscrews

More information

FUJITSU Server PRIMERGY RX2510 M2

FUJITSU Server PRIMERGY RX2510 M2 Operating Manual - English FUJITSU Server PRIMERGY RX2510 M2 Operating Manual February 2016 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

PRIMERGY SX940 S1 Storage Blade

PRIMERGY SX940 S1 Storage Blade Operating manual - English PRIMERGY SX940 S1 Storage Blade Operating manual Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

PRIMERGY CX272 S1 Server Node

PRIMERGY CX272 S1 Server Node Upgrade and Maintenance Manual - English PRIMERGY CX272 S1 Server Node Upgrade and Maintenance Manual February 2014 Comments Suggestions Corrections The User Documentation Department would like to know

More information

PRIMERGY RX100 S6 Server. Operating manual

PRIMERGY RX100 S6 Server. Operating manual PRIMERGY RX100 S6 Server Operating manual Edition December 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

HP ProLiant MicroServer

HP ProLiant MicroServer HP ProLiant MicroServer Installation Sheet Part Number 615715-004 Panel door components Item Component 1 16 screws for HDD installation 2 4 screws for ODD installation 3 Screw driver Rear panel components

More information

PRIMERGY TX150 S5 Server

PRIMERGY TX150 S5 Server PRIMERGY PRIMERGY TX150 S5 Server Options Guide Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: 0 700 / 372 00000 TX150

More information

FUJITSU Server PRIMERGY RX100 S8

FUJITSU Server PRIMERGY RX100 S8 Operating Manual - English FUJITSU Server PRIMERGY RX100 S8 Operating Manual Edition May 2014 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options CHAPTER 4 Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options This chapter provides instructions for installing, replacing, and removing various hardware options in your Cisco ADE

More information

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Order Number:

More information

Operating Manual - English PRIMERGY RX200 S6. Operating Manual

Operating Manual - English PRIMERGY RX200 S6. Operating Manual Operating Manual - English PRIMERGY RX200 S6 Operating Manual April 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback

More information

FUJITSU Server PRIMERGY TX1330 M2

FUJITSU Server PRIMERGY TX1330 M2 Operating Manual - English FUJITSU Server PRIMERGY TX1330 M2 Operating Manual December 2016 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

PRIMERGY BX924 S2 Server Blade

PRIMERGY BX924 S2 Server Blade Operating Manual - English PRIMERGY BX924 S2 Server Blade Operating Manual Edition May 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

PRIMERGY SX650 Storage Blade. Operating Manual

PRIMERGY SX650 Storage Blade. Operating Manual PRIMERGY SX650 Storage Blade Operating Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

PRIMERGY TX100 S3 Server

PRIMERGY TX100 S3 Server Operating Manual - English PRIMERGY TX100 S3 Server Operating Manual Edition November 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

FUJITSU Server PRIMERGY TX1320 M3

FUJITSU Server PRIMERGY TX1320 M3 Operating Manual - English FUJITSU Server PRIMERGY TX1320 M3 Operating Manual March 2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

PRIMERGY BX920 S2 Server Blade

PRIMERGY BX920 S2 Server Blade Operating Manual - English PRIMERGY BX920 S2 Server Blade Operating Manual Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

PRIMERGY TX120 S3 Server

PRIMERGY TX120 S3 Server Operating Manual - English PRIMERGY TX120 S3 Server Operating Manual Edition May 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

System Board D3034 for PRIMERGY RX100 S7

System Board D3034 for PRIMERGY RX100 S7 Technical Manual - English System Board D3034 for PRIMERGY RX100 S7 Technical Manual Edition August 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

PRIMERGY SX910 S1 Storage Blade

PRIMERGY SX910 S1 Storage Blade Operating Manual - English PRIMERGY SX910 S1 Storage Blade Operating Manual Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

PRIMERGY TX200 S7 Server

PRIMERGY TX200 S7 Server Operating Manual - English PRIMERGY TX200 S7 Server Operating manual Edition June 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

JanusRAID SA-6692J Hardware User Manual

JanusRAID SA-6692J Hardware User Manual JanusRAID SA-6692J Hardware User Manual 42-30000-5067 SATA II JBOD enclosure Version 1.1 SA-6692J SATA II JBOD enclosure Hardware User Manual Table of Contents Preface... i Chapter 1 System Requirements

More information

Chapter 1 Names and Functions This chapter explains the names and functions of the parts.

Chapter 1 Names and Functions This chapter explains the names and functions of the parts. PRIMERGY SX650 Storage Blade Hardware Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Make sure to read before using

More information

Operating Manual - English. FUJITSU Server PRIMERGY TX1330 M3 Operating Manual

Operating Manual - English. FUJITSU Server PRIMERGY TX1330 M3 Operating Manual Operating Manual - English FUJITSU Server PRIMERGY TX1330 M3 Operating Manual May2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

PRIMERGY CX122 S1 Server

PRIMERGY CX122 S1 Server Operating Manual - English PRIMERGY CX122 S1 Server Operating Manual Edition November 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

PRIMERGY TX300 S4 Server. Options Guide

PRIMERGY TX300 S4 Server. Options Guide PRIMERGY TX300 S4 Server Options Guide Edition December 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions... Table of Contents Quick Install Guide page 1 EN English Table of Contents 1. Introduction... 2 1.1 Safety... 2 1.2 Rack System Precautions... 2-3 1.3 ESD Precautions... 3... 3 1... 3 2 Fitting PSU s...

More information

Intel NUC Kit DN2820FYKH User Guide. Intel NUC Kit DN2820FYKH User Guide

Intel NUC Kit DN2820FYKH User Guide. Intel NUC Kit DN2820FYKH User Guide Intel NUC Kit DN2820FYKH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers and with the safety

More information

FUJITSU Server PRIMERGY TX2540 M1

FUJITSU Server PRIMERGY TX2540 M1 Operating Manual - English FUJITSU Server PRIMERGY TX2540 M1 Operating Manual January 2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

FUJITSU Server PRIMERGY RX1330 M3

FUJITSU Server PRIMERGY RX1330 M3 Operating Manual - English FUJITSU Server PRIMERGY RX1330 M3 Operating Manual March 2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

FUJITSU Server PRIMERGY RX2520 M1

FUJITSU Server PRIMERGY RX2520 M1 Operating Manual - English FUJITSU Server PRIMERGY RX2520 M1 Operating manual Edition February 2015 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of

More information

PRIMERGY TX300 S3 Server

PRIMERGY TX300 S3 Server PRIMERGY PRIMERGY TX300 S3 Server Options Guide Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: (++49) 700 /

More information

Intel NUC Kit D54250WYKH & D34010WYKH User Guide. Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide

Intel NUC Kit D54250WYKH & D34010WYKH User Guide. Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers

More information

PRIMERGY BX920 S1 Server-Blade. Service Supplement

PRIMERGY BX920 S1 Server-Blade. Service Supplement PRIMERGY BX920 S1 Server-Blade Service Supplement Edition April 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

FUJITSU Server PRIMERGY CX400 M4 Server Enclosure

FUJITSU Server PRIMERGY CX400 M4 Server Enclosure Operating Manual - English FUJITSU Server PRIMERGY CX400 M4 Server Enclosure Operating Manual July 2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed

More information

PRIMERGY RX200 S7 Server

PRIMERGY RX200 S7 Server Operating Manual - English PRIMERGY RX200 S7 Server Operating Manual Edition November 2013 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

To connect the AC adapter:

To connect the AC adapter: Replacing the AC Adapter Replacing the AC Adapter 3 Plug the power cord into a wall outlet. The power indicator turns on. To connect the AC adapter: Connect the power cord to the AC adapter. Power indicator

More information

PRIMERGY TX100 S2 Server

PRIMERGY TX100 S2 Server Operating Manual - English PRIMERGY TX100 S2 Server Operating Manual March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback

More information

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx Preface Obtaining Documentation and Submitting a Service Request, page xvii Safety s, page xvii Safety Guidelines, page xx Obtaining Documentation and Submitting a Service Request For information on obtaining

More information

Intel NUC Kit DC53427HYE User Guide. Intel NUC Kit DC53427HYE

Intel NUC Kit DC53427HYE User Guide. Intel NUC Kit DC53427HYE Intel NUC Kit DC53427HYE User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers and with the safety

More information

easyraid Q24P2-U4R4 Hardware Manual

easyraid Q24P2-U4R4 Hardware Manual easyraid Q24P2-U4R4 Hardware Manual 42-30000-5105 SCSI Channel to Serial ATA II Disk Array System Version 1.0 easyraid Q24P2-U4R4 U320 SCSI Channel to Serial ATA II Disk Array System Hardware User Manual

More information

Removal and Installation8

Removal and Installation8 8 Screw Types 8-4 Top Cover Assembly 8-5 Left Hand Cover 8-6 Right Hand Cover 8-10 Front Panel Assembly 8-14 Left Rear Cover 8-15 Right Rear Cover 8-16 Extension Cover (60" Model only) 8-17 Media Lever

More information

LVN5200A-R2, rev. 1, Hardware Installation Guide

LVN5200A-R2, rev. 1, Hardware Installation Guide LVN5200A-R2 LVN5250A-R2 LVN5200A-R2, rev. 1, Hardware Installation Guide Customer Support Information Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support

More information

FUJITSU Server PRIMERGY RX2510 M2

FUJITSU Server PRIMERGY RX2510 M2 Operating Manual - English FUJITSU Server PRIMERGY RX2510 M2 Operating Manual June 2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

Replacing the Power Supply

Replacing the Power Supply APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools

More information

PRIMERGY RX600 S4 Server. Service Supplement

PRIMERGY RX600 S4 Server. Service Supplement PRIMERGY RX600 S4 Server Service Supplement Edition December 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

FibreCAT TXF Backup Subsystem. Service Supplement

FibreCAT TXF Backup Subsystem. Service Supplement FibreCAT TXF Backup Subsystem Service Supplement Edition October 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide Copyright Information The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing

More information

User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC)

User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC) User Guide - English FUJITSU Software ServerView Suite Local Service Panels Local Service Concept (LSC) Last Edition August 2017 Comments Suggestions Corrections The User Documentation Department would

More information

Intel NUC Kit NUC7i7BNH, NUC7i5BNH & NUC7i3BNH User Guide. Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide

Intel NUC Kit NUC7i7BNH, NUC7i5BNH & NUC7i3BNH User Guide. Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated

More information

FUJITSU Server PRIMERGY RX2530 M4

FUJITSU Server PRIMERGY RX2530 M4 Operating Manual - English FUJITSU Server PRIMERGY RX2530 M4 Operating Manual July 2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK. User Guide

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK. User Guide Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers

More information

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter Industrial PC IPC191V2 General Operating, Maintenance and Installation Manual Hardware Platform Protocol Converter D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 78 Internet: http://www.ipcomm.de

More information

SCSI Cable Installation Instructions

SCSI Cable Installation Instructions Identifying the SCSI Cable Parts SCSI Cable Installation Instructions for HP ProLiant DL100 Series Generation 2 Servers Item Description 1 Connector end 2 240 mm location 3 Terminator end Read instructions

More information

FUJITSU Server PRIMERGY RX2540 M4

FUJITSU Server PRIMERGY RX2540 M4 Operating Manual - English FUJITSU Server PRIMERGY RX2540 M4 Operating manual July 2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x

Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x Last Updated: December 4, 2014 Use these instructions to replace the RAID battery backup unit (BBU)

More information

System Board D3031 for PRIMERGY RX200 S6

System Board D3031 for PRIMERGY RX200 S6 Technical Manual - English System Board D3031 for PRIMERGY RX200 S6 Technical Manual Edition August 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not

More information

Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH

Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated

More information

Intel NUC Kit NUC5i3MYHE & NUC5i5MYHE User Guide. Intel NUC Kit NUC5i3MYHE Intel NUC Kit NUC5i5MYHE User Guide

Intel NUC Kit NUC5i3MYHE & NUC5i5MYHE User Guide. Intel NUC Kit NUC5i3MYHE Intel NUC Kit NUC5i5MYHE User Guide Intel NUC Kit NUC5i3MYHE Intel NUC Kit NUC5i5MYHE User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers

More information

Multi-Mount for Mac Pro " to 5.25" Drive Bay Converter Bracket. Assembly & Installation Manual

Multi-Mount for Mac Pro  to 5.25 Drive Bay Converter Bracket. Assembly & Installation Manual Multi-Mount for Mac Pro 2009-2010 3.5" to 5.25" Drive Bay Converter Bracket Assembly & Installation Manual Introduction 1 INTRODUCTION 1.1 System Requirements 1.1.1 Computer Requirements 1.1.2 Hard Drive

More information

Installation Job Aid for VSP 4450GTX-HT- PWR+

Installation Job Aid for VSP 4450GTX-HT- PWR+ Installation Job Aid for VSP 4450GTX-HT- PWR+ Notices Release 6.1.0.0 NN46251-305 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

FCC COMPLICANCE STATEMENT

FCC COMPLICANCE STATEMENT FCC COMPLICANCE STATEMENT For Users in the USA This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of FCC Rules. These rules are designed

More information

User Guide for NUC8i5BEK, NUC8i3BEK. Intel NUC Kit NUC8i5BEK Intel NUC Kit NUC8i3BEK. User Guide

User Guide for NUC8i5BEK, NUC8i3BEK. Intel NUC Kit NUC8i5BEK Intel NUC Kit NUC8i3BEK. User Guide Intel NUC Kit NUC8i5BEK Intel NUC Kit NUC8i3BEK User Guide 1 Before You Begin CAUTIONS The steps in this guide assume you re familiar with computer terminology and with the safety practices and regulatory

More information

Fujitsu Cluster-in-a-box based on PRIMERGY BX400-S/M/L PRIMERGY CX420-S/M

Fujitsu Cluster-in-a-box based on PRIMERGY BX400-S/M/L PRIMERGY CX420-S/M User Guide - English Fujitsu Cluster-in-a-box based on PRIMERGY BX400-S/M/L PRIMERGY CX420-S/M Getting Started Edition April 2013 Comments Suggestions Corrections The User Documentation Department would

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

User Guide for NUC7CJYSAL. Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL. User Guide

User Guide for NUC7CJYSAL. Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL. User Guide Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL User Guide 1 Before You Begin CAUTIONS The steps in this guide assume you re familiar with computer terminology and with the safety practices

More information

Intel NUC Kit NUC7i3BNHX1 with Intel Optane Memory. Intel NUC Kit NUC7i5BNHX1 with Intel Optane Memory

Intel NUC Kit NUC7i3BNHX1 with Intel Optane Memory. Intel NUC Kit NUC7i5BNHX1 with Intel Optane Memory Intel NUC Kit NUC7i3BNHX1 with Intel Optane Memory Intel NUC Kit NUC7i5BNHX1 with Intel Optane Memory Intel NUC Kit NUC7i7BNHX1 with Intel Optane Memory User Guide 1 Before You Begin CAUTIONS The procedures

More information

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers

More information

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Job Aid for Ethernet Routing Switch 3600 Series Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions

More information

Installation Job Aid for VSP 4850GTS

Installation Job Aid for VSP 4850GTS Installation Job Aid for VSP 4850GTS Notices Release 6.1.0.0 NN46251-308 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs describe

More information