Data Center Power Savings

Size: px
Start display at page:

Download "Data Center Power Savings"

Transcription

1 Data Center Power Savings

2 Data Center Power Savings Keith Mastrian, Regional Sales Manager, Raritan Data center power usage effectiveness (PUE), developed by The Green Grid, has received a lot of attention. But how do you use PUE to minimize wasted power? How do you identify stranded power and thereby possibly delay the construction of a very expensive new data center? How do you justify for management the investment to gather detailed power information? This session will reveal the answers to these questions through a detailed discussion about deploying smart PDUs with outlet-level monitoring and environmental sensors, developing a plan to gather information, and making the most of that information once it has been gathered

3 Metrics: PUE, DCiE, and Carbon Footprint PUE = Total Facility Power IT Equipment Power DCiE = IT Equipment Power Total Facility Power x 100% Carbon Emissions (kg) = Energy (kwh) * Carbon Factor (kg/kwh) Assumptions: 10Mw total, 5 Mw IT, $0.10/kwh, 7x24 operation PUE = 10 Mw/5 Mw = 2.0, DCiE = 50% 8760 hours x $0.10/kwh x 10 Mw = $8.76M annual cost of power Example Carbon Factors: PG&E =.24 kg/kwh Con Ed =.35 kg/kwh CO2 = 8760 hours x 10 Mw x.35 kg/kwh CO2 = 30,660,000 kg (about 6759* cars) *based on ~12k miles and ~4536kg

4 The roadmap to your PUE IT equipment power measurement from Total facility power measurement from Minimum measurement interval Level 1 Basic Level 2 Intermediate Level 3 Advanced UPS PDU Server Data center input power Data center input less shared HVAC Data center input less shared HVAC plus building, lighting, security Monthly/weekly Daily Continuous Source: greengrid.org

5 Green Grid PUE level 1 Green Grid PUE level 2 Green Grid PUE level 3 Source: greengrid.org

6 So why measure? Driving forces behind measuring Source: greengrid.org, energy measurements survey results analysis

7 Actions prompted by efficiency metrics Source: greengrid.org, energy measurements survey results analysis

8 Lower PUE is better, right? On Average, typical DC is ~ 2.0 High range > 2.75 Low range < 1.5 What happens to PUE if we raise the temperature? Cooling load goes down, PUE goes down What happens to PUE if we shut 10% of servers that are deemed ghost servers? IT load goes down, PUE goes up What happens to PUE if we also throttle the cooling to meet the new lower IT loads? IT load goes down, Cooling load goes down, PUE could remain the same PUE is useful but may not be the end all. Ultimately you want to minimize waste and save $$$. Stay tuned, other productivity metrics are coming

9

10 What is an ipdu? Intelligent (rack) Power Distribution Unit Metering down to individual outlets, plus circuit breakers & PDU level Rich power data collection Voltage (V), Current (A), Power Factor, Apparent Power (kva), Active Power (Watts), Energy Consumption (kwh) Remote control of power on/off/recycle Some with integration with KVM Local display & remote GUI Network based 10/100/1000 or wireless Secure Encryption of sessions and session data: HTTPS, SSH, AES, SSL Rich user /user group AAA: LDAP/AD Standards based management SNMP V2, V2, V3 with encryption Built-in support for environmental sensors

11 Tale of Two Cities IT: That s awesome. Facilities: Hmm more components that can fail.

12 The tale of the two cities IT Lingo Facilities Lingo Networking: 10/100/1000, a/b/g/n Plug (NEMA, IEC, IP67/Splashproof) Protocols: TCP/IP, HTTPS Cordset (gauge, jacket, weight, SOOW, plenum-rated) Security: AES, SSL Chassis (Metal, Ventilation, Button Mounting) Interfaces and Interoperability: ODBC, WS-API, SSH, RS-232, RJ- 11, RJ-45, LDAP/AD Manageability: SNMP, thresholds, alerts Receptacles (Soldered? Terminals?) Relays Circuit Breakers (Magneto-Hydraulic / Magneto-Thermal)

13 ASHRAE new recommended operating environment New recommended is 65F to 80F Old recommended is 68F to 77F New allowable is ~60F to 90F NEBS 65F 80F Source: ASHRAE, Thermal Guidelines for Data Processing Environments

14 ASHRAE - Where to measure temperature Source: ASHRAE, Thermal Guidelines for Data Processing Environments

15 What do I do with all this power data? Find stranded power capacity by knowing the actual power load at all levels including racks and IT devices Increase uptime by getting alerts before breakers trip Understand your carbon footprint by charting the carbon emitted to generate the energy consumed Report carbon footprint for business units to drive sustainability initiatives implementing billback programs to drive efficiency behavior Increase energy efficiency by scheduled power control, and measuring changes in consumption due to savings programs Measure PUE, understand how efficient you are, implement efficiency projects, increase utilization and reduce waste, compare with your peers, and improved efficiency

16 Don t forget element & energy management software Something has to collect all this good data Consider accuracy of data What about polling frequency Something has to calculate, trend, and report against the data What about my existing stuff? Don t forget element management Actual load information can also feed change and capacity mgmt tools How much does all this cost?

17 What do I do with the environmental data? Plot CFD like views to quickly see overcooling and hot spots Plot trends of rack inlet temperatures Check if you re operating within ASHRAE guidelines Get a quick look at the environment when you get alerts Vs. nameplate, see the real effect effect of changes to the environment Add servers, add blades, virtualize servers, decomission servers Add blanking plates, add cold/hot aisle containment, shut off CRAC, VFDs on CRAC, add economizers

18 Is there a way to justify the incremental costs for ipdu s? You can t manage what you don t measure Factor in all costs, it might be a wash Totally integrated intelligent rack pdu solution vs. cobbling together the pieces, plus related costs of additional drops, e.g. cabling, Ethernet ports, patch panel ports, etc. Funding might be available in your regions PG&E, American Recovery & Reinvestment Act, California Energy Commission Start small: Build it in phases and learn/see value by showing data to management Energy savings ROI models available from vendors

19 The Ecosystem - It all has to work together to realize economies IT Admins DC Operations DC Manager/Facilities Facilities 3 rd Party Systems IT Equipment Life cycle Management Data Center Asset, Visualization, Change, Capacity, Operations Management Data Center Energy Management Building Management Trouble Ticketing, CMDB, Network Mgmt, Reporting, Workflow, BMS, Billing IT Equipment HTTPS, IPMI, RDP, SSH, SMASH CLP, SNMP, WMI, Modbus, BACNet Power Distribution, Cooling, and Environment/Building Controls SNMP, Web Services, ODBC

20 Resources Green Grid: EPA Server and Data Center Energy Efficiency Initiatives: iciency US Green Building & LEED: ASHRAE: Spec.org: American Clean Energy & Security Act (Waxman Markey): Climate Savers: Sustainable Buildings Industry Council: Raritan:

21 Thank you! Keith Mastrian Regional Sales Manager ext. 12

22 Power densities what can we do about it? Higher power to the rack Higher current, 30A to 60A 3 phase* 24x208x1.73 = 8.6kW 40x208x1.73 = 14.4kW 48*208*1.73 = 17.3kW Higher voltage, trend towards 400V 3 phase to the rack 24x400x1.73 = 16.6kW 48x400x1.73 = 33.2kW Move cooling closer to the IT load Design zones in the data center 5kW racks + 17kW racks *assumes pf = 1

23 Power densities additional benefits from 400V Less copper Less weight Less space Less cost Source: General Cable Carolprene

Data Center Infrastructure Management (DCIM) Demystified

Data Center Infrastructure Management (DCIM) Demystified software is quickly becoming the core engine of data center operations. Only 5 years ago, manual spreadsheets, sometimes supplemented with Visio diagrams, were accepted as the default tools for data center

More information

Deploying High Power to IT Equipment Racks

Deploying High Power to IT Equipment Racks 2012 Raritan Inc. Table of Contents Overview Page 3 Trends in Data Center Power Deployment Page 3 Drivers for High Power Racks Page 3 Data Center Power Distribution Around the World Page 4 What Is High

More information

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc. Cooling on Demand - scalable and smart cooling solutions Marcus Edwards B.Sc. Schroff UK Limited Data Centre cooling what a waste of money! A 1MW data center needs 177,000,000 kwh in its lifetime of 10

More information

EO and Smart Federal Government Data Center Management

EO and Smart Federal Government Data Center Management 1 Overview In fiscal year 2009, the U.S. government used an astounding 1,095.7 trillion BTUs of energy. This total included everything from keeping the lights on at the Lincoln Memorial to maintaining

More information

Deploying High Power to IT Equipment Racks

Deploying High Power to IT Equipment Racks 1 Deploying High Power to IT Equipment Racks A White Paper from Raritan 2 Table of Contents Overview...3 Trends in Data Center Power Deployment...3 Drivers for High Power Racks...4 Data Center Power Distribution

More information

DCIM Data Center Infrastructure Management

DCIM Data Center Infrastructure Management DCIM Data Center Infrastructure Management Part 2 Implementation Challenges & Strategic Advantages - Predictive Analysis August 8, 2013 Presented by Julius Neudorfer Sponsored by Today s Topics Implementation

More information

DCIM Data Center Infrastructure Management

DCIM Data Center Infrastructure Management DCIM Data Center Infrastructure Management Part 3 Operational Management Moves Adds and Changes & Electrical Infrastructure November 5, 2013 Presented by Julius Neudorfer Sponsored by Today s Topics Operational

More information

18 th National Award for Excellence in Energy Management. July 27, 2017

18 th National Award for Excellence in Energy Management. July 27, 2017 18 th National Award for Excellence in Energy Management July 27, 2017 ICICI Bank, Data Centre, August Hyderabad 30 & 31, 2017 ICICI Bank - Revolution in Digital Banking Over 100,000 Digital POS in 4 months

More information

MSYS 4480 AC Systems Winter 2015

MSYS 4480 AC Systems Winter 2015 MSYS 4480 AC Systems Winter 2015 Module 12: DATA CENTERS By Satwinder Singh 14/05/2015 1 Data Centers Data Centers are specialized environments that safeguard your company's most valuable equipment and

More information

Polar PDUs POWER MANAGEMENT

Polar PDUs POWER MANAGEMENT Polar Power Distribution Units (PDUs) provide the ultimate solution for combining cabinet level power management, environmental monitoring, and cabinet access control in multi-tenant and enterprise data

More information

Features and Benefits: Power IQ DCIM Monitoring Solutions

Features and Benefits: Power IQ DCIM Monitoring Solutions 1 : Power IQ DCIM Monitoring Solutions Vendor-agnostic Management Energy Efficiency Through one web browser, monitor any device from major manufactures such as APC, Avocent, BayTech, Chatsworth, Cyber

More information

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model Austin Data Center 6Sigma DC CFD Model Keith Ward Keith Ward Data Center Facilities Engineering and Logistics Design Austin Data Center Statistics - Space Original AT&T Designed and

More information

Server Technology Inc.

Server Technology Inc. Server Technology Inc. Power Efficiency Gains by Deploying 415 VAC Power Distribution in North American Data Centers White Paper STI-100-008 2011-Sept-22 Headquarters Server Technology, Inc. 1040 Sandhill

More information

MEASURE MONITOR UNDERSTAND

MEASURE MONITOR UNDERSTAND MEASURE MONITOR UNDERSTAND Presented by Alistair Hunt Energy Monitoring, Measurement metrics Where and What 1 History & Background Company Timeline 18 Years Comrac & Sinetica founded 15 Years Raritan Integration

More information

ipdu Pocket Guide NORTH AMERICA

ipdu Pocket Guide NORTH AMERICA Best in Class Outlet Density Optimal Form Factors Superior Reliability TM ipdu Pocket Guide NORTH AMERICA Welcome to the Panduit G5 Series of PDU s and Accessories Quality & Reliability 3-Year standard

More information

WIRELESS ENVIRONMENTAL MONITORS

WIRELESS ENVIRONMENTAL MONITORS Packet Powers compact wireless Environmental Monitors makes it easy and affordable to monitor all environmental conditions in your facility. From installation to monitoring in minutes 1 Place wireless

More information

RAMP DCIM Data Center Infrastructure Management Software

RAMP DCIM Data Center Infrastructure Management Software RAMP DCIM Data Center Infrastructure Management Software RFP TEMPLATE 1-866-612-3637 SALES@TUANGRU.COM TUANGRU.COM DCIM RFP TEMPLATE Dear Sir or Madam, Your company has been invited to submit your company

More information

DCIM Data Center Infrastructure Management Measurement is the first step

DCIM Data Center Infrastructure Management Measurement is the first step DCIM Data Center Infrastructure Management Measurement is the first step Presented by Julius Neudorfer Sponsored by DCIM Data Center Infrastructure Management Measurement is the first step Presented by

More information

Intelligent PDUs. Best in Class Outlet Density Optimal Form Factors Superior Reliability

Intelligent PDUs. Best in Class Outlet Density Optimal Form Factors Superior Reliability TM Intelligent PDUs Best in Class Outlet Density Optimal Form Factors Superior Reliability SmartZone G5 Value Proposition Quality & Reliability High Temp High Power Density Hot-Swappable and Upgradable

More information

Power Monitoring in the Data Centre

Power Monitoring in the Data Centre Power Monitoring in the Data Centre Fixed or Wireless Steve Strange RCDD ANIXTER INTERNATIONAL Agenda Energy Consumption Case Study Reasons to Monitor Power Monitoring Environmental Monitoring Asset Tags

More information

ipdu Pocket Guide INTERNATIONAL

ipdu Pocket Guide INTERNATIONAL Best in Class Outlet Density Optimal Form Factors Superior Reliability TM ipdu Pocket Guide INTERNATIONAL Welcome to the Panduit G5 Series of PDU s and Accessories Quality & Reliability 3-Year standard

More information

Innovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s

Innovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s Structure Source PDU s Innovative Power Engineering High Quality Power Distribution for the Data Centre structure source Making the complex, simple structure source product range Rack and Server Power

More information

The -3Ph extension on a product indicates a 3 Phase power product.

The -3Ph extension on a product indicates a 3 Phase power product. Power Terms Glossary 20-Amp Power Input Support: 20-amp Power Input Support. IEC320/C20 power inlet receptacles supports any power cord with IEC320/C19 power connector (PTCORD-XX). 24-Character Outlet

More information

Power IQ for econnect

Power IQ for econnect 1 Center Energy, Power, Environmental, and Access Control Monitoring Software In today s data center, being efficient with power and cooling resources is just as important as maintaining uptime. Power

More information

survey, 71% of respondents listed Improving capacity planning as a top driver for buying DCIM 1.

survey, 71% of respondents listed Improving capacity planning as a top driver for buying DCIM 1. :: In a recent Uptime Institute survey, 71% of respondents listed Improving capacity planning as a top driver for buying DCIM 1. 2 Maintain Assess Control ROI Monitor Optimize The Need for a Better Approach

More information

Modius OpenData v3.3. Product Overview of Modius OpenData for Unified Data Center Monitoring & Analysis

Modius OpenData v3.3. Product Overview of Modius OpenData for Unified Data Center Monitoring & Analysis Modius OpenData v3.3 Product Overview of Modius OpenData for Unified Data Center Monitoring & Analysis Modius Inc. 832 Folsom, Suite 1001 San Francisco, CA 94107 888.323.0066 info@modius.com www.modius.com

More information

Green Data Centers A Guideline

Green Data Centers A Guideline Green Data Centers A Guideline Sekhar Kondepudi Ph.D Associate Professor Smart Buildings & Smart Cities Vice Chair Focus Group on Smart Sustainable Cities ITU-TRCSL Workshop on Greening the Future: Bridging

More information

1.0 Executive Summary. 2.0 Available Features & Benefits

1.0 Executive Summary. 2.0 Available Features & Benefits Statement Of Work Energy Management Services Table of Contents 1.0 Executive Summary 2.0 Available Features & Benefits 3.0 Assessment Deliverables Selection 4.0 On Site Assessment Activities 5.0 Exclusions

More information

Data Center Infrastructure Management (D.C.I.M.)

Data Center Infrastructure Management (D.C.I.M.) Data Center Infrastructure Management (D.C.I.M.) Garies Chong, RCDD, DCDC. BICSI Southeast Asia District Chair Managing Director of EMS Wiring Systems Pte Ltd Data Center Infrastructure Management (D.C.I.M.)

More information

APC APPLICATION NOTE #74

APC APPLICATION NOTE #74 #74 Configuration of InfraStruXure for Data Centers to Support Dell PowerEdge 1855 Abstract Many companies are making plans to incorporate Dell PowerEdge Blade Servers into their data center applications.

More information

Power and Cooling for Ultra-High Density Racks and Blade Servers

Power and Cooling for Ultra-High Density Racks and Blade Servers Power and Cooling for Ultra-High Density Racks and Blade Servers APC White Paper #46 Richard L. Sawyer Director of Data Center Technology American Power Conversion Company 2005 APC corporation What has

More information

Optimization in Data Centres. Jayantha Siriwardana and Saman K. Halgamuge Department of Mechanical Engineering Melbourne School of Engineering

Optimization in Data Centres. Jayantha Siriwardana and Saman K. Halgamuge Department of Mechanical Engineering Melbourne School of Engineering Optimization in Data Centres Jayantha Siriwardana and Saman K. Halgamuge Department of Mechanical Engineering Melbourne School of Engineering Outline Background and Motivation Overview and scale of data

More information

Measurement and Management Technologies (MMT)

Measurement and Management Technologies (MMT) IBM Systems Lab Services and Training Measurement and Management Technologies (MMT) Data Center Solutions for a Smarter Planet AGENDA IBM Energy Efficiency Program & Accomplishments IBM CO2 Reduction Commitment

More information

Green IT and Green DC

Green IT and Green DC Green IT and Green DC Alex SL Tay Regional Service Product Line Manager Site & Facilities Services, IBM ASEAN 1 What our clients are telling us We are running out of space in our data center We have environmental

More information

Predictive Resilience: Leveraging Integrated DCIM to Reduce Data Center Downtime

Predictive Resilience: Leveraging Integrated DCIM to Reduce Data Center Downtime July 17, 2013 Predictive Resilience: Leveraging Integrated DCIM to Reduce Data Center Downtime siemens.com/answers Predictive Resilience Table of content What is DCIM & Its Business Value Extract Maximum

More information

Frequently Asked Questions

Frequently Asked Questions Q. What is the power metering accuracy on CPI econnect PDUs? A. The power metering accuracy on CPI econnect PDUs is ±1% for each breaker. Meters are included in Monitored, Monitored, Switched and Switched

More information

Over IP Group. Data Centre Infrastructure Management (DCIM)

Over IP Group. Data Centre Infrastructure Management (DCIM) Over IP Group Data Centre Infrastructure Management (DCIM) Mission To Protect the World s Network Through Innovation Let s Get Connected Over IP Group Agenda The Aim of CenterOS DCIM What is the CenterOS

More information

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA Smart Data Centres Robert M Pe, Data Centre Consultant Services SEA 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice Content Data center

More information

PX Intelligent Rack PDUs

PX Intelligent Rack PDUs PX Intelligent Rack PDUs Rack Power Distribution Units for Your Data Center Raritan s PX intelligent rack PDU series offers more than just power distribution -- it s a launch pad for real-time remote power

More information

CA ecometer. Overview. Benefits. agility made possible. Improve data center uptime and availability through better energy management

CA ecometer. Overview. Benefits. agility made possible. Improve data center uptime and availability through better energy management PRODUCT SHEET: CA ecometer CA ecometer Improve data center uptime and availability through better energy management agility made possible CA ecometer helps you to visualize, monitor, and better manage

More information

PX Intelligent Rack PDUs

PX Intelligent Rack PDUs PX Intelligent Rack PDUs Rack Power Distribution Units for Your Data Center Raritan s PX intelligent rack PDU series offers more than just power distribution -- it s a launch pad for real-time remote power

More information

Efficiency of Data Center cooling

Efficiency of Data Center cooling Efficiency of Data Center cooling Comparison of data room layouts and cooling systems Bohumil Cimbal Product manager for Cooling Systems in CONTEG Company Objective Basic questions between investor and

More information

Google s Green Data Centers: Network POP Case Study

Google s Green Data Centers: Network POP Case Study Google s Green Data Centers: Network POP Case Study Table of Contents Introduction... 2 Best practices: Measuring. performance, optimizing air flow,. and turning up the thermostat... 2...Best Practice

More information

Comprehensive Data Center Energy Management Solutions

Comprehensive Data Center Energy Management Solutions FROM INSIGHT TO EFFICIENCY: Comprehensive Data Center Energy Management Solutions Since 1995, facility managers and BAS professionals have relied on the Niagara framework to provide full convergence of

More information

Data Center Infrastructure Management ( DCiM )

Data Center Infrastructure Management ( DCiM ) Page 1 Data Center Infrastructure Management ( DCiM ) DCiM is defined by technology researchers and analysts as the integration of information technology (IT) and facility management disciplines to centralize

More information

Power Distribution Units for Data Centers

Power Distribution Units for Data Centers WWW.SIEMON.COM Power Distribution Units for Data Centers PowerMax Power Distribution Units Siemon s PowerMax line of PDUs range from basic and metered for simple, reliable and cost-effective power distribution,

More information

How to Increase Data Center Efficiency

How to Increase Data Center Efficiency How to Increase Data Center Efficiency Shivani Shukla Potkar Product Marketing Manager Pentair Electronics Protection High cooling efficiency & and reduced power consumption enhances the balance between

More information

Product brochure. Eaton epdu G3. Simplify installation. Enhance operation. Maximize control.

Product brochure. Eaton epdu G3. Simplify installation. Enhance operation. Maximize control. Product brochure Eaton epdu G3 Simplify installation. Enhance operation. Maximize control. Power distribution made better by Eaton The Eaton epdu G3 rack mounted power distribution units (PDUs) provide

More information

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw IT COOLING CLOSE CONTROL AIR CONDITIONERS CHILLED WATER HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw 3 Versions available Single chilled water coil Double chilled water coil High temperature IT COOLING

More information

ECO PDU Power Distribution Unit

ECO PDU Power Distribution Unit ECO PDU Distribution Unit PE6108/PE6208/PE8108/PE8208 ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage.

More information

PDU Inspired by Your Data Center. W IEC PDU Series

PDU Inspired by Your Data Center. W IEC PDU Series PDU Inspired by Your Data Center W IEC PDU Series Intelligent kwh PDU - W series Power Efficiency Management With today s increasing demand for high technology power management solutions, PDU kwh measurement

More information

Features and Benefits: dctrack DCIM Operations Solution

Features and Benefits: dctrack DCIM Operations Solution 1 : Asset Auto Discovery Allows for automatic recognition integration into dctrack asset management system for a newly added asset. Automatic recognition of make model of asset makes adding or changing

More information

Product Brochure. Eaton epdu G3 Managed

Product Brochure. Eaton epdu G3 Managed Product Brochure Eaton epdu G3 Managed Advanced power management and precision control The Eaton epdu third generation (G3) Managed models build on Eaton s existing state-of-the-art epdu G3 technology

More information

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director Energy Logic: A Roadmap for Reducing Energy Consumption in the Data Center Emerson Network Power Ross Hammond Managing Director Agenda Energy efficiency Where We Are Today What Data Center Managers Are

More information

Product Brochure. Eaton epdu G3 Managed

Product Brochure. Eaton epdu G3 Managed Product Brochure Eaton epdu G3 Managed Advanced power management and precision control The Eaton epdu third generation (G3) Managed models build on Eaton s existing state-of-the-art epdu G3 technology

More information

THE OFFICIAL TRADE JOURNAL OF BICSI

THE OFFICIAL TRADE JOURNAL OF BICSI ICT TODAY THE OFFICIAL TRADE JOURNAL OF BICSI January/February 2017 Volume 38, Number 1 + PLUS + Information Security and ESS in the Age of the Internet of Things + Grounding System Design and Testing

More information

DC Energy, Efficiency Challenges

DC Energy, Efficiency Challenges DC Energy, Efficiency Challenges Choosing a density strategy Implementing a high density environment Maximizing the efficiency benefit Anticipating the dynamic data center Key points on energy usage in

More information

ARTO LIND ABB Ability Datacenter Automation. The way to monitor & control your DC infrastructure (DCIM) Datacenter Infrastructure Management

ARTO LIND ABB Ability Datacenter Automation. The way to monitor & control your DC infrastructure (DCIM) Datacenter Infrastructure Management ARTO LIND ABB Ability Datacenter Automation The way to monitor & control your DC infrastructure (DCIM) Datacenter Infrastructure Management Data Center common functionality DCIM needs to be open to handle

More information

Basic vs. Intelligent PDUs. Understanding the Differences

Basic vs. Intelligent PDUs. Understanding the Differences 1 Basic vs. Intelligent PDUs Understanding the Differences Table of Contents 1 What Are the Differences Between Basic and Intelligent PDUs? 2 Why Is Choosing the Right PDU Important? 3 Major Challenges

More information

Eaton Open Data Centre Solutions. Kari Koli

Eaton Open Data Centre Solutions. Kari Koli Eaton Open Data Centre Solutions Presenter: Stefan Coote Kari Koli 2008 Eaton Corporation. All rights reserved. Eaton Worldwide Founded in 1911 by J.O. Eaton World Headquarters in Cleveland, Ohio USA Customers

More information

ECO PDU PE7108/PE7208

ECO PDU PE7108/PE7208 PE7108/PE7208 ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage. The PE7108 / PE7208 eco PDUs are intelligent

More information

PE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU

PE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU PE8208 20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU 8 outlets 20A (UL derated 16A) / 16A Outlet Power Measurement The PE8208 eco PDU is intelligent PDUs that contains 8 AC outlets and is available

More information

ABB Automation & Power World: April 18-21, 2011 CLP CEU Myth Busting: The Truth behind Data Center Marketing Trends

ABB Automation & Power World: April 18-21, 2011 CLP CEU Myth Busting: The Truth behind Data Center Marketing Trends ABB Automation & Power World: April 18-21, 2011 CLP-101-1-CEU Myth Busting: The Truth behind Data Center Marketing Trends May 10, 2011 Slide 1 CLP-101-1-CEU Myth Busting: The Truth behind Data Center Marketing

More information

PX INTELLIGENT RACK PDUS

PX INTELLIGENT RACK PDUS PX INTELLIGENT RACK PDUS SMARTER RACK POWER DISTRIBUTION Raritan s PX intelligent rack PDU Series offers more than just power distribution it s a launch pad for real-time remote power monitoring, environmental

More information

Data Centre Energy Efficiency. Duncan Clubb EMEA Data Centre Practice Director CS Technology

Data Centre Energy Efficiency. Duncan Clubb EMEA Data Centre Practice Director CS Technology Data Centre Energy Efficiency Duncan Clubb EMEA Data Centre Practice Director CS Technology Key Messages No more silos energy efficiency only comes from a holistic approach to DC design and operation If

More information

PE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU. 8 outlets. 20A (UL derated 16A) / 16A. Outlet Power Measurement

PE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU. 8 outlets. 20A (UL derated 16A) / 16A. Outlet Power Measurement PE8208 20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU 8 outlets 20A (UL derated 16A) / 16A Outlet Power Measurement The PE8208 eco PDU is intelligent PDUs that contains 8 AC outlets and is available

More information

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link)

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link) CS-12HDE444C8 (Master) CL-12HDE444C8 (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while

More information

ECO PDU PE5108/PE5208

ECO PDU PE5108/PE5208 1 NRGence Energy Intelligence Solutions PE5108/PE5208 ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage.

More information

Energy Saving Best Practices

Energy Saving Best Practices Energy Saving Best Practices BICSI Meeting West Kingston, RI 16 October 2008 Vinnie Jain, CDCP Advanced Marketing Manager Ortronics/Legrand VJ-1July08 IT Spending on the Rise 600 500 400 $B 300 200 100

More information

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight Liebert icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight LIEBERT icom THERMAL SYSTEM CONTROLS All for One, One for All Optimize a Single Cooling Unit With an Intelligent

More information

Innovative monitoring of your data center with DIRIS Digiware

Innovative monitoring of your data center with DIRIS Digiware Innovative monitoring of your data center with DIRIS Digiware Why should you implement power monitoring within your data center? Improving the energy efficiency of your data center allows you to get an

More information

EDX DC-3 environmental monitoring solution

EDX DC-3 environmental monitoring solution EDX DC-3 environmental monitoring solution Designed to monitor and report on power, temperature and humidity conditions within a data centre, in real-time. Data Centre Power Consumption, Cooling Or Hot

More information

84 kw, Tier 3, Direct Expansion, 937 ft 2

84 kw, Tier 3, Direct Expansion, 937 ft 2 [Reference Design 42] 84 kw, Tier 3, Direct Expansion, 937 ft 2 DESIGN OVERVIEW Data Center IT Capacity 84 kw Target Availability Tier 3 Annualized PUE at 100% Load 1.712 Total Racks and Average Density

More information

Power Distribution Units for Data Centers

Power Distribution Units for Data Centers BRC_PowerMax_INT_Draft_I.qxp_Layout 1 9/11/17 2:00 PM Page 2 Power Distribution Units for Data Centers WWW.SIEMON.COM PowerMax Power Distribution Units 2 Siemon s PowerMax line of PDUs range from basic

More information

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered Survey and Audit Service Schedule Airflow and Thermal Imaging Survey Service Schedule Data Centre Solutions Expertly Engineered Consult optimisation, audit and survey services Data Centre Services Workspace

More information

PN5212/PN5320/PN7212/PN7320

PN5212/PN5320/PN7212/PN7320 PN522/PN520/PN722/PN720 Power Over the NET Power Distribution Units ALTUSEN Power Over the NET products are Power Distribution Units that offer outlet level control combined with remote access to give

More information

PDU - Overview / Non-Intelligent PDU s

PDU - Overview / Non-Intelligent PDU s PDU - Overview / Non-Intelligent PDU s InfraPower Rack Power Distribution Units InfraPower Rack PDU Range Switched (Outlet kwh PDU) Monitored (kwh PDU) Metered Basic WSi WS W MD Basic Outlet Measurement

More information

RaMP Data Center Manager. Data Center Infrastructure Management (DCIM) software

RaMP Data Center Manager. Data Center Infrastructure Management (DCIM) software RaMP Data Center Manager Data Center Infrastructure Management (DCIM) software One solution for both IT and facilities managers As data centers become more complex, it becomes increasingly important to

More information

Ft Worth Data Center Power Metering for Real Time PUE Calculation. Scope of Work

Ft Worth Data Center Power Metering for Real Time PUE Calculation. Scope of Work Ft Worth Data Center Power Metering for Real Time PUE Calculation Scope of Work Prepared for the General Services Administration By Lawrence Berkeley National Laboratory Rod Mahdavi December 13, 2010 Executive

More information

Measurement and Management Technologies (MMT) for more energy efficient Data Center and Telecommunication Facilities

Measurement and Management Technologies (MMT) for more energy efficient Data Center and Telecommunication Facilities Information and Communication Technology Portfolio Review San Francisco, CA March 2011 Project Name: Measurement and Management Technologies (MMT) for more energy efficient Data Center and Telecommunication

More information

Next Generation Data Center Facilities Design. Presenter: Ping Lin

Next Generation Data Center Facilities Design. Presenter: Ping Lin Next Generation Data Center Facilities Design Presenter: Ping Lin ping.lin@cqinc.com.tw What is the greatest facility problem with your primary data center? 1. Excessive Heat 2. Insufficient raised floor

More information

EP s approach to Power & Energy efficiency in DCs & paradigms

EP s approach to Power & Energy efficiency in DCs & paradigms DG for Innovation and Technological Support EP s approach to Power & Energy efficiency in DCs & paradigms Presentation Presentation subtitle subtitle or lead-in or lead-in that says that what says what

More information

The ipdu Handbook. A Guide to Intelligent Rack Power Distribution

The ipdu Handbook. A Guide to Intelligent Rack Power Distribution The ipdu Handbook A Guide to Intelligent Rack Power Distribution The ipdu Handbook A Guide to Intelligent Rack Power Distribution Raritan began developing KVM switches for IT professionals to manage servers

More information

IT Level Power Provisioning Business Continuity and Efficiency at NTT

IT Level Power Provisioning Business Continuity and Efficiency at NTT IT Level Power Provisioning Business Continuity and Efficiency at NTT Henry M.L. Wong Intel Eco-Technology Program Office Environment Global CO 2 Emissions ICT 2% 98% Source: The Climate Group Economic

More information

OpenManage Power Center Demo Guide for https://demos.dell.com

OpenManage Power Center Demo Guide for https://demos.dell.com OpenManage Power Center Demo Guide for https://demos.dell.com Contents Introduction... 3 Lab 1 Demo Environment... 6 Lab 2 Change the default settings... 7 Lab 3 Discover the devices... 8 Lab 4 Group Creation

More information

Data Center Design and. Management. Steve Knipple. August 1, CTO / VP Engineering & Operations

Data Center Design and. Management. Steve Knipple. August 1, CTO / VP Engineering & Operations Data Center Design and Energy Management Steve Knipple CTO / VP Engineering & Operations August 1, 2013 Agenda Introduction to EasyStreet Speaker Bio EasyStreet Sustainability Data Center 1 (Retrofit completed

More information

How much power?! Data Centre Efficiency. How much Money?! Carbon Reduction Commitment (CRC)

How much power?! Data Centre Efficiency. How much Money?! Carbon Reduction Commitment (CRC) How much power?! Data Centre Efficiency The US EPA found in 2006 data centres used 1.5% of total US consumption (5) For Bangor University data centres use approximately 5-10% of the total university electricity

More information

Switch to Perfection

Switch to Perfection Switch to Perfection Traditional Data Centre - Temperatures Ideal Air Temperature: 22 C Chilled Water: 7-9 C Heat Load per Rack: Up to 4,5 Chilling & Pump Set The challenge a thermal image Front View of

More information

ECO PDU. Features. PE5220sA

ECO PDU. Features. PE5220sA ECO PDU PE5220s As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage. The NRGence

More information

Power IQ Version from Version

Power IQ Version from Version Power IQ Version 2.0.1 from Version 1.5.1-10 These Release Notes contain important information regarding the release of this product, so please read the entire document carefully. We also strongly recommend

More information

ROI CASE STUDY MAY Logicalis Achieves 159% ROI* with CA DCIM Solution

ROI CASE STUDY MAY Logicalis Achieves 159% ROI* with CA DCIM Solution ROI CASE STUDY MAY 2015 Logicalis Achieves 159% ROI* with CA DCIM Solution 2 ROI CASE STUDY: LOGICALIS MAY 2015 Logicalis increases efficiency and maximizes availability with CA DCIM UK service provider

More information

Energy efficiency within data centers Is your IT organization capitalizing on the latest technology options and best practices?

Energy efficiency within data centers Is your IT organization capitalizing on the latest technology options and best practices? This is a photographic template your photograph should fit precisely within this rectangle. Energy efficiency within data centers Is your IT organization capitalizing on the latest technology options and

More information

SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers

SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers SmartZone Rack Energy Kits Features:

More information

G GRCOW PH6PS6-D-IP44 Power Monitoring, Outlet Level. Part Number

G GRCOW PH6PS6-D-IP44 Power Monitoring, Outlet Level. Part Number Part Number Power Configuration Physical Configuration G1306 -- GRCOW246-103PH6PS6-D-IP44 Power Monitoring, Outlet Level 32A,, 7.3kW 72 in / 1829 mm Vertical Description G1306 -- GRCOW246-103PH6PS6-D-IP44

More information

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden Where s the Heat Coming From Leland Sparks Global Account Technical Consultant Belden What is the greatest DC challenge you face? Air Flow to Heat Load Relation Server Inlet Fans Chips Outlet LOAD Dell

More information

Inspired by Your Data Center. Intelligent W Series : 3 - Phase 208V

Inspired by Your Data Center. Intelligent W Series : 3 - Phase 208V Inspired by Your Data Center Intelligent W Series : 3 - Phase 208V Three Phase for Rising Power Usage High power density has been implemented in applications such as high-end network switches, storage

More information

Data Centre Energy & Cost Efficiency Simulation Software. Zahl Limbuwala

Data Centre Energy & Cost Efficiency Simulation Software. Zahl Limbuwala Data Centre Energy & Cost Efficiency Simulation Software Zahl Limbuwala BCS Data Centre Simulator Overview of Tools Structure of the BCS Simulator Input Data Sample Output Development Path Overview of

More information

How do I... If you manage a datacenter, we have a solution for you. Sentry : Cabinet Power Distribution Unit Product Family : Metered CDU.

How do I... If you manage a datacenter, we have a solution for you. Sentry : Cabinet Power Distribution Unit Product Family : Metered CDU. If you manage a datacenter, we have a solution for you. How do I... Distribute power to all the equipment in the cabinet? Distribute and load balance 3-phase power? Monitor True RMS input current? Reboot

More information

Switched, Outlet Level Monitoring

Switched, Outlet Level Monitoring Part Number Power Configuration Physical Configuration RCURN082-102D20TL5-OD Switched, Outlet Level Monitoring 20A, 120V, 1.9kW 19in / 483mm Horizontal Description The RCURN082-102D20TL5-OD provides hands-on

More information

Intelligent W Series : 3 - Phase 208V 20A / 30A. Inspired by Your Data Center

Intelligent W Series : 3 - Phase 208V 20A / 30A. Inspired by Your Data Center Intelligent W Series : 3 - Phase 208V 20A / 30A Inspired by Your Data Center Three Phase for Rising Power Usage High power density has been implemented in applications such as high-end network switches,

More information