Ethernet IP Datalink. Introduction

Size: px
Start display at page:

Download "Ethernet IP Datalink. Introduction"

Transcription

1 Object Dictionary 1 Ethernet IP Datalink Introduction The Ethernet Internet Protocol (IP) Datalink object manages the Ethernet communications bus and the messages transmitted on it. This object allows access to Ethernet card statistics. May 1, 2002 Johnson Controls, Inc. Code No. LIT Software Release 5.1

2 2 Ethernet IP Datalink Attributes Specific Attributes Table 1: Attribute Properties Table 1 lists attributes specific to the Ethernet IP Datalink object. The Ethernet IP Datalink object also has the attributes of the Metasys Common object. Refer to Table 1 in the Metasys Common Object chapter (LIT ) for details. Attribute Name Data Type Options/Range Metasys Common See Table 1 in the Metasys Common Object chapter (LIT ). Attributes Address Length Byte Default = 6 BACnet IP Port Unsigned Integer Broadcast Address Octet String Maximum length = 6 Broadcast Receives Broadcast Transmits Bytes In Bytes Out Collision Errors Device Address Octet String Maximum length = 6 Errors In Errors Out Message Receives Message Transmits Multiple Collisions Network Address One Collision OWC Collision Packets In Packets Lost Packets Out Reset Date Reset Time Retry Attempts RX CRC Errors RX FIFO Errors RX Frame Errors RX Other Errors RX Overwrite Errors Continued on next page... Unsigned Integer Date Time

3 Object Dictionary 3 Attribute Name (Cont.) Data Type Options/Range Transmit Failures TX Carrier Errors TX Delayed TX FIFO Errors TX SQE Errors TX Other Errors

4 4 Ethernet IP Datalink Attribute Definitions Table 2: Attribute Definitions Attribute Name Metasys Common Attributes Address Length BACnet IP Port Broadcast Address Broadcast Receives Broadcast Transmits Bytes In Bytes Out Collision Errors Device Address Errors In Errors Out Message Receives Message Transmits Multiple Collisions Network Address One Collision OWC Collision Packets In Packets Lost Packets Out Reset Date Reset Time Retry Attempts RX CRC Errors RX FIFO Errors RX Frame Errors RX Other Errors RX Overwrite Errors TX Carrier Errors Continued on next page... Table 2 lists the definitions of the attributes specific to the Ethernet IP Datalink object. Definition See Table 2 in the Metasys Common Object chapter (LIT ). Indicates the number of octets for the device address (Data Link Address). Indicates the IP port number that the device uses to transmit and receive messages. Indicates the address used when sending broadcast messages. Indicates the number of broadcast messages received. Indicates the number of broadcast message transmissions. Indicates the bytes received from the Ethernet. Indicates the bytes sent to the Ethernet. Indicates that excessive collisions occurred and send aborted. Indicates the address of the device (Data Link Address). Indicates the number of errors detected when receiving messages from the Ethernet. Indicates the number of errors detected when sending messages to the Ethernet. Indicates the number of messages received. Indicates the number of message transmissions. Indicates that more than one collision occurred during the successful sending of message. Indicates the BACnet Network address of this data link. Indicates that one collision occurred during the successful sending of a message. Indicates that an Out-of-Window Collision occurred during the successful sending of a message. Indicates the number of data packets received from the Ethernet. Indicates the number of data packets lost when receiving messages from the Ethernet due to momentary shortage of receive buffers. Indicates the number of data packets sent to the Ethernet. Indicates the date of the clear statistics command. Indicates the time of the clear statistics command. Indicates the number of retry attempts. Indicates the data packet Cyclic Redundancy Check (CRC) errors. Indicates First-In-First-Out (FIFO) overruns on the Ethernet chip. Indicates the data packet is too large. Indicates miscellaneous errors like ring buffer corrupt, ring buffer overflow, frame alignment error, FIFO overrun, missed packet. Indicates ring buffer overflows on the Ethernet chip. Indicates carrier sense errors.

5 Object Dictionary 5 Attribute Name (Cont.) TX Delayed Errors TX FIFO Errors TX Other Errors TX SQE Errors Transmit Failures Definition Indicates the delay due to busy media/network. Indicates the FIFO underruns. Indicates miscellaneous errors like transmit timeout, remote Direct Memory Access (DMA) failure. Indicates sequence (SQE) errors. Indicates the number of message transmit failures.

6 6 Ethernet IP Datalink Commands The Ethernet IP Datalink object supports the commands listed in Table 3. The order of the commands in the table reflects how the commands appear on the user interface. Table 3: Supported Commands Command Name Parameters Access Level Description Latch Statistics Operate Allows a current reading of the statistics. Clear Statistics Operate Allows the user to clear the statistics. Controls Group 507 E. Michigan Street P.O. Box 423 Milwaukee, WI Printed in U.S.A.

Object Dictionary 1. Pager. Introduction

Object Dictionary 1. Pager. Introduction Object Dictionary 1 Pager Introduction The Pager object provides alarm notifications via pager to personnel at a remote location who would otherwise not be aware of the alarm coming into a workstation

More information

Display. Introduction

Display. Introduction Object Dictionary 1 Display Introduction The Display object configures the display of a Local Display Terminal (LDT) in an N30 supervisory controller. Use Project Builder to create a Display object for

More information

Multistate Value/ BACnet Multistate Value

Multistate Value/ BACnet Multistate Value Object Dictionary 1 Multistate Value/ BACnet Multistate Value Introduction Note: The Johnson Controls Multistate Value object is considered a BACnet Multistate Value object because it supports BACnet functionality.

More information

Trend Log/BACnet Trend Log

Trend Log/BACnet Trend Log Object Dictionary 1 Trend Log/BACnet Trend Log Introduction Notes: The Johnson Controls Trend Log object is considered a BACnet Trend Log object because it supports BACnet functionality. In addition, this

More information

N2 Analog Input/ BACnet Analog Input

N2 Analog Input/ BACnet Analog Input Object Dictionary 1 N2 Analog Input/ BACnet Analog Input Introduction Note: The Johnson Controls N2 Analog Input object is considered a BACnet Analog Input object because it supports BACnet functionality.

More information

N2 Binary Input/ BACnet Binary Input

N2 Binary Input/ BACnet Binary Input Object Dictionary 1 N2 Binary Input/ BACnet Binary Input Introduction Note: The Johnson Controls Binary Input object is considered a BACnet Binary Input object, because it supports BACnet functionality.

More information

N2 Multistate Output/ BACnet Multistate Output

N2 Multistate Output/ BACnet Multistate Output Object Dictionary 1 N2 Multistate Output/ BACnet Multistate Output Introduction Note: The Johnson Controls N2 Multistate Output object is considered a BACnet Multistate Output object because it supports

More information

Device Diagnostic. Introduction

Device Diagnostic. Introduction Object Dictionary 1 Device Diagnostic Introduction The Device Diagnostic object supports various diagnostic functions of the device and monitors the device for an overload condition. This object allows

More information

N2 Binary Output/ BACnet Binary Output

N2 Binary Output/ BACnet Binary Output Object Dictionary 1 N2 Binary Output/ BACnet Binary Output Introduction Note: The Johnson Controls Binary Output object is considered a BACnet Binary Output object because it supports BACnet functionality.

More information

Runtime Totalization. Introduction

Runtime Totalization. Introduction Object Dictionary 1 Runtime Totalization Introduction The Runtime Totalization object tracks the time that elapses while a designated input, such as a binary or multistate value, matches a specified state.

More information

Interface Performance

Interface Performance CHAPTER 9 There are two performance options in CGM: performance menus and the Performance Manager. The difference between these two options is that the Performance Manager displays historical data as well

More information

Remote Monitoring. Remote Monitoring Overview

Remote Monitoring. Remote Monitoring Overview Overview, page 1 Access Web Page, page 2 Control Web Page Access, page 3 Device Information Area, page 3 Network Configuration Area, page 4 Ethernet Information Area, page 7 Device Logs Area, page 9 Streaming

More information

Downloading Metasys Integrator 300 Series Code

Downloading Metasys Integrator 300 Series Code M-Tool Manual 693 System Tools Applications Section Issue Date 0101 APPLICATION NOTE Downloading Metasys Integrator 300 Series Code Downloading Metasys Integrator 300 Series Code...3 Introduction...3 Key

More information

Monitoring Ports. Port State

Monitoring Ports. Port State The Ports feature available on the ME 1200 Web GUI allows you to monitor the various port parameters on the ME 1200 switch. Port State, page 1 Port Statistics Overview, page 2 QoS Statistics, page 2 QCL

More information

Metasys Integrator Multistack Application

Metasys Integrator Multistack Application Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date 0998 APPLICATION NOTE Metasys Integrator Multistack Application lntroduction Page *3 Application Details

More information

Metasys Integrator Caterpillar Application

Metasys Integrator Caterpillar Application Application Note Issue Date May, 00 APPLICATION NOTE Metasys Integrator Caterpillar Application Introduction Application Details Component Requirements Vendor Contact Information Design Considerations

More information

Working with BACnet Group Objects

Working with BACnet Group Objects N30 Supervisory Controller User s Manual 33-1 Chapter 33 Working with BACnet Group Objects Introduction Note: Do not confuse the BACnet Group object with the Johnson Controls Group object. For information

More information

Schedule/BACnet Schedule

Schedule/BACnet Schedule Object Dictionary 1 Schedule/BACnet Schedule Introduction Note: The Johnson Controls Schedule object is considered a BACnet Schedule object because it supports BACnet functionality. In addition, this object

More information

Management IP Interface

Management IP Interface The management interface is used for the video control plane messages, such as session creation and deletion, between the Logical Edge Devices (LED) and the external Edge Resource Manager (ERM) server.

More information

Working with Objects and the M-View Screen

Working with Objects and the M-View Screen Project Builder User s Guide 6-1 Chapter 6 Working with Objects and the M-View Screen Introduction The Project Builder uses a variety of objects to configure controllers and perform tasks. This chapter

More information

Metasys Integrator Allen-Bradley Custom Application

Metasys Integrator Allen-Bradley Custom Application Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date 0998 APPLICATION NOTE Metasys Integrator Allen-Bradley Custom Application Introduction Page 3 Application

More information

Cisco Introduction to Cisco Networking Technologies Exam. Practice Test. Version 2.2. https://certkill.com

Cisco Introduction to Cisco Networking Technologies Exam. Practice Test. Version 2.2. https://certkill.com Cisco 640-821 640-821 Introduction to Cisco Networking Technologies Exam Practice Test Version 2.2 QUESTION NO: 1 Refer to the exhibit. Why was this message received? A. No VTY password has been set B.

More information

1. Data Link Layer Protocols

1. Data Link Layer Protocols 1. Data Link Layer Protocols Purpose of the Data Link Layer The Data Link Layer Purpose of the Data Link Layer Data Link Sublayers Network LLC Sublayer Data Link Physical MAC Sublayer 802.3 Ethernet 802.11

More information

Using M-Collector. Using M-Collector...2. Introduction Key Concepts... 3

Using M-Collector. Using M-Collector...2. Introduction Key Concepts... 3 Technical Bulletin Issue Date October 3, 2003 Using M-Collector Using M-Collector...2 Introduction... 2 Key Concepts... 3 M-Collector... 3 Configuration... 3 Runtime Display...4 Maximum Capacity... 6 Collection

More information

Troubleshooting Ethernet Collisions

Troubleshooting Ethernet Collisions Troubleshooting Ethernet Collisions Document ID: 12768 Contents Introduction Prerequisites Requirements Components Used Conventions What Are Collisions? The Deferred Counter The Collisions Counter Late

More information

Guide to Loopback Using the DP8390 Chip Set

Guide to Loopback Using the DP8390 Chip Set Guide to Loopback Using the DP8390 Chip Set OVERVIEW Loopback capabilities are provided to allow certain tests to be performed to validate operation of the DP8390 NIC the DP8391 SNI and the DP8392 CTI

More information

Metasys for Validated Environments (MVE) Installation and Platform Requirements

Metasys for Validated Environments (MVE) Installation and Platform Requirements Issue Date 2/7/03 TECHNICAL BULLETIN Metasys for Validated Environments (MVE) Installation and Platform Requirements Metasys for Validated Environments (MVE) Installation and Platform Requirements...2

More information

Searching for Access Points

Searching for Access Points Information About, page 1 Searching the AP Filter (GUI), page 1 Monitoring the Interface Details, page 4 Searching for Access Point Radios, page 6 Information About You can search for specific access points

More information

Configuring Interfaces on the ML-Series Card

Configuring Interfaces on the ML-Series Card 5 CHAPTER This chapter describes basic interface configuration for the ML-Series card to help you get your ML-Series card up and running. Advanced packet-over-sonet (POS) interface configuration is covered

More information

Course Introduction. Purpose. Objectives. Content. Learning Time

Course Introduction. Purpose. Objectives. Content. Learning Time Course Introduction Purpose This training course provides an overview of Message Frames and hardware issues of the Controller Area Network (CAN) technology used to build networked, multiprocessor embedded

More information

FCC Ethernet Controller

FCC Ethernet Controller FCC Ethernet Controller The FCC is in Ethernet mode when the GFMR [28:31] is set to %1010 This controller supports both Ethernet and IEEE 802.3 protocols, which are very similar, handling the necessary

More information

Global Interface Commands on the Cisco ASR 9000 Series Router

Global Interface Commands on the Cisco ASR 9000 Series Router Global Interface Commands on the Cisco ASR 9000 Series Router This module provides global command line interface (CLI) commands for configuring interfaces on the Cisco ASR 9000 Series Aggregation Services

More information

Integrated Device Technology, Inc Stender Way, Santa Clara, CA Phone #: (408) Fax #: (408) Errata Notification

Integrated Device Technology, Inc Stender Way, Santa Clara, CA Phone #: (408) Fax #: (408) Errata Notification Integrated Device Technology, Inc. 2975 Stender Way, Santa Clara, CA - 95054 Phone #: (408) 727-6116 Fax #: (408) 727-2328 Errata Notification EN #: IEN01-02 Errata Revision #: 11/5/01 Issue Date: December

More information

80C300. Full Duplex CMOS Ethernet 10/100 Mega Bit/Sec Data Link Controller 98012

80C300. Full Duplex CMOS Ethernet 10/100 Mega Bit/Sec Data Link Controller 98012 Full Duplex HURRICANE TM 80C300 Full Duplex CMOS Ethernet 10/100 Mega Bit/Sec Data Link Controller 98012 Features Low Power CMOS Technology 10/100 MBit Ethernet Controller Optimized for Switching Hub,

More information

Global Interface Commands on the. Cisco ASR 9000 Series Router.

Global Interface Commands on the. Cisco ASR 9000 Series Router. Global Interface Commands on the Cisco ASR 9000 Series Router This module describes the global command line interface (CLI) commands for configuring interfaces on the Cisco ASR 9000 Series Router. bandwidth

More information

Configuring IRB. Integrated Routing and Bridging CHAPTER

Configuring IRB. Integrated Routing and Bridging CHAPTER CHAPTER 11 This chapter describes how to configure integrated routing and bridging (IRB) for the ML-Series card. For more information about the Cisco IOS commands used in this chapter, refer to the Cisco

More information

Metasys BACnet System Integrator (BSI) Monitoring

Metasys BACnet System Integrator (BSI) Monitoring Metasys Connectivity Technical Manual 629.5 Metasys BACnet System Integrator Section Issue Date 73 TECHNICAL BULLETIN Metasys BACnet System Integrator (BSI) Monitoring Monitoring the BSI Communicator...2

More information

Configuring Interfaces and Circuits

Configuring Interfaces and Circuits CHAPTER 5 This chapter describes how to configure the CSS interfaces and circuits and how to bridge interfaces to Virtual LANs (VLANs). Information in this chapter applies to all CSS models, except where

More information

Table of Contents 1 Ethernet Interface Configuration Commands 1-1

Table of Contents 1 Ethernet Interface Configuration Commands 1-1 Table of Contents 1 Ethernet Interface Configuration Commands 1-1 broadcast-suppression 1-1 description 1-2 display brief interface 1-3 display interface 1-4 display loopback-detection 1-8 duplex 1-9 flow-control

More information

TECHNICAL BULLETIN. Using M-Authorize. Using M-Authorize...2. Introduction Key Concepts... 3

TECHNICAL BULLETIN. Using M-Authorize. Using M-Authorize...2. Introduction Key Concepts... 3 Issue Date May 31, 2002 TECHNICAL BULLETIN Using M-Authorize Using M-Authorize...2 Introduction... 2 Key Concepts... 3 Software Authorization... 3 Johnson Controls Software Authorization Form... 3 Detailed

More information

Ethernet Interface Configuration Commands

Ethernet Interface Configuration Commands Table of Contents Ethernet Interface Configuration Commands 1 General Ethernet Interface/Subinterface Configuration Commands 1 combo enable 1 description 1 display interface 2 display interface brief 9

More information

Polling the N2 Network or Zone Bus for Devices

Polling the N2 Network or Zone Bus for Devices Metasys Checkout Tool User s Guide 3-1 Chapter 3 Polling the N2 Network or Zone Bus for Devices Introduction The first step in the checkout process is using the Metasys Checkout Tool to find and display

More information

ICC. Metasys N2 Master Driver Manual INDUSTRIAL CONTROL COMMUNICATIONS, INC Industrial Control Communications, Inc.

ICC. Metasys N2 Master Driver Manual INDUSTRIAL CONTROL COMMUNICATIONS, INC Industrial Control Communications, Inc. INDUSTRIAL CONTROL COMMUNICATIONS, INC. Metasys N2 Master Driver Manual January 5, 2018 2018 Industrial Control Communications, Inc. TABLE OF CONTENTS 1 Metasys N2 Master... 2 1.1 Overview... 2 1.2 Connections...

More information

Configuring Interfaces

Configuring Interfaces CHAPTER 6 The chapter applies to the ML-Series (ML100T-2, ML100X-8, ML1000-2 cards. This chapter describes basic interface configuration for the ML-Series card to help you get your ML-Series card up and

More information

Metasys Integrator United Power Application

Metasys Integrator United Power Application Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date 0998 APPLICATION NOTE Metasys Integrator United Power Application lntroduction Page 3 Application Details

More information

N30 Supervisory Controller Quick Start

N30 Supervisory Controller Quick Start Issue Date June 30, 2004 TECHNICAL BULLETIN N30 Supervisory Controller Quick Start N30 Supervisory Controller Quick Start...2 Introduction... 2 Key Concepts... 3 Using This Document... 3 Related Information...

More information

Chapter. Managed Switch Software Monitoring. In This Chapter...

Chapter. Managed Switch Software Monitoring. In This Chapter... Managed Switch Software Monitoring Chapter 23 In This Chapter... System Information...3 2 Port and Power Status...3 4 Network Statistics...3 5 Spanning Tree Status...3 8 Real-Time Ring Status...3 10 Multicast

More information

Contents. Introduction. Methodology. Check for Output Drops. Introduction Methodology

Contents. Introduction. Methodology. Check for Output Drops. Introduction Methodology Contents Introduction Methodology Check for Output Drops Determine if the Drops are Unicast or Multicast Determine Which Output Buffer is Used Check the Active Buffer Monitoring Counters Actively Increment

More information

Ethernet Interface Configuration Commands

Ethernet Interface Configuration Commands Table of Contents Ethernet Interface Configuration Commands 1 General Ethernet Interface/Subinterface Configuration Commands 1 combo enable 1 description 1 display interface 2 display interface brief 9

More information

Metasys Installation and Platform Requirements

Metasys Installation and Platform Requirements Issue Date June 1, 2002 TECHNICAL BULLETIN Metasys Installation and Platform Requirements Metasys Installation and Platform Requirements...2 Introduction... 2 Key Concepts... 3 Operating System Support...

More information

Troubleshooting EtherNet/IP Networks

Troubleshooting EtherNet/IP Networks www.odva.org Troubleshooting EtherNet/IP Networks By Merrill Harriman Schneider Electric Technical Track Introduction Overview Mysterious counters Diagnostic tools Access mechanisms Ethernet counters Troubleshoot

More information

Error Detection Codes. Error Detection. Two Dimensional Parity. Internet Checksum Algorithm. Cyclic Redundancy Check.

Error Detection Codes. Error Detection. Two Dimensional Parity. Internet Checksum Algorithm. Cyclic Redundancy Check. Error Detection Two types Error Detection Codes (e.g. CRC, Parity, Checksums) Error Correction Codes (e.g. Hamming, Reed Solomon) Basic Idea Add redundant information to determine if errors have been introduced

More information

Software Architecture Document: Addendum

Software Architecture Document: Addendum L3x UART Software Architecture Software Architecture Document: Addendum Information in this document is subject to change without notice. Texas Instruments may have pending patent applications, trademarks,

More information

CHAPTER 4 DATA COMMUNICATION MODES

CHAPTER 4 DATA COMMUNICATION MODES USER S MANUAL CHAPTER DATA COMMUNICATION MODES. INTRODUCTION The SCC provides two independent, full-duplex channels programmable for use in any common asynchronous or synchronous data communication protocol.

More information

P2000 Commend Intercom Interface Option

P2000 Commend Intercom Interface Option P2000 Commend Interface Option Product Bulletin Code No. LIT-12012142 Software Release 3.14 Issued November 30, 2015 Johnson Controls offers a purchase option that enables the P2000 Security Management

More information

Ethernet interface commands

Ethernet interface commands Contents Ethernet interface commands 1 Common Ethernet interface commands 1 default 1 description 2 display counters 2 display counters rate 4 display interface 5 display interface brief 12 display packet-drop

More information

Lecture 6 Datalink Framing, Switching. From Signals to Packets

Lecture 6 Datalink Framing, Switching. From Signals to Packets Lecture 6 Datalink Framing, Switching David Andersen Department of Computer Science Carnegie Mellon University 15-441 Networking, Spring 2005 http://www.cs.cmu.edu/~srini/15-441/s05/ 1 From Signals to

More information

Troubleshoot interface down issues in Cisco routers

Troubleshoot interface down issues in Cisco routers Troubleshoot interface down issues in Cisco routers Contents Introduction Prerequisites Requirements Conventions Troubleshoot Methodology Troubleshoot Examples Introduction This document describes troubleshoot

More information

Metasys Integrator GE Lighting Application

Metasys Integrator GE Lighting Application Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date 0998 APPLICATION NOTE Metasys Integrator GE Lighting Application lntroduction Page 3 Application Details

More information

1/29/2008. From Signals to Packets. Lecture 6 Datalink Framing, Switching. Datalink Functions. Datalink Lectures. Character and Bit Stuffing.

1/29/2008. From Signals to Packets. Lecture 6 Datalink Framing, Switching. Datalink Functions. Datalink Lectures. Character and Bit Stuffing. /9/008 From Signals to Packets Lecture Datalink Framing, Switching Peter Steenkiste Departments of Computer Science and Electrical and Computer Engineering Carnegie Mellon University Analog Signal Digital

More information

What Bytes Are Counted by IP to ATM CoS Queueing?

What Bytes Are Counted by IP to ATM CoS Queueing? What Bytes Are Counted by IP to ATM CoS Queueing? Document ID: 10420 Contents Introduction Prerequisites Requirements Components Used Conventions Determine the Value for the Bandwidth Statement in a QoS

More information

Configuring the SS7 Q.703 High Speed Port Adapter

Configuring the SS7 Q.703 High Speed Port Adapter CHAPTER 4 Configuring the SS7 Q.703 High Speed Port Adapter This chapter contains the following sections: Using the EXEC Command Interpreter, page 4-1 Configuring the Interfaces, page 4-2 Checking the

More information

Metasys System Extended Architecture Glossary

Metasys System Extended Architecture Glossary Technical Bulletin Issue Date March 31, 2003 Metasys System Extended Architecture Glossary Key Concepts... 2 Metasys System Extended Architecture Component Acronyms... 2 Metasys System Extended Architecture

More information

Metasys Database Manager Installation Instructions Code No. LIT Software Release 9.0 Issued August 2017

Metasys Database Manager Installation Instructions Code No. LIT Software Release 9.0 Issued August 2017 Code No. LIT-12011553 Software Release 9.0 Issued August 2017 Refer to the QuickLIT website for the most up-to-date version of this document. Document Introduction...2 Summary of Changes...2 Metasys Database

More information

SAMI Cisco IOS PPC Commands

SAMI Cisco IOS PPC Commands APPENDIXC The following commands, listed in alphabetical order, are introduced or modified for the Cisco SAMI Cisco IOS PPCs and are supported at the SAMI Cisco IOS PPC console: clear sami ixp statistics

More information

S300-DIN-RDR2SA Address Mode Configuration

S300-DIN-RDR2SA Address Mode Configuration Technical Bulletin Issue Date August 17, 2010 S300-DIN-RDR2SA Address Mode Configuration The S300-DIN-RDR2SA (also referred to as ) can be addressed in two ways: legacy mode and physical address mode.

More information

EtherChannel & Highly Available Cluster Multiprocessing (HACMP) in AIX V5.2 How-to and Test Experiences

EtherChannel & Highly Available Cluster Multiprocessing (HACMP) in AIX V5.2 How-to and Test Experiences EtherChannel & Highly Available Cluster Multiprocessing (HACMP) in AIX V5.2 How-to and Test Experiences Introduction Abstract: This document gives tips and a working example of how to a Highly Available

More information

Metasys Web Access System Overview

Metasys Web Access System Overview Technical Bulletin Issue Date February 18, 2003 Metasys Web Access System Overview Metasys Web Access System Overview...2 Introduction... 2 Key Concepts... 3 Related Information... 3 Hardware and Software

More information

80C04A AutoDUPLEX TM CMOS Ethernet Data Link Controller

80C04A AutoDUPLEX TM CMOS Ethernet Data Link Controller 3 2 1 68 67 66 65 64 63 62 61 9 8 7 6 5 4 80C04A 80C04A AutoDUPLEX TM CMOS Ethernet Data Link Controller PRELIMINARY March 1994 Features Pinout and function compatible with the 80C04 except for the function

More information

Configuring Link Aggregation on the ML-MR-10 card

Configuring Link Aggregation on the ML-MR-10 card CHAPTER 34 Configuring Link Aggregation on the ML-MR-10 card This chapter applies to the ML-MR-10 card and describes how to configure link aggregation for the ML-Series cards, both EtherChannel and packet-over-sonet/sdh

More information

Data Link Layer: Overview, operations

Data Link Layer: Overview, operations Data Link Layer: Overview, operations Chapter 3 1 Outlines 1. Data Link Layer Functions. Data Link Services 3. Framing 4. Error Detection/Correction. Flow Control 6. Medium Access 1 1. Data Link Layer

More information

SLC 5/03, SLC 5/04 and SLC 5/05 Operating Systems

SLC 5/03, SLC 5/04 and SLC 5/05 Operating Systems Document Update SLC 5/03, SLC 5/04 and SLC 5/05 Operating Systems (Catalog Numbers 1747-L531, 1747-L532, 1747-L541, 1747-L542, 1747-L543, 1747-L551, 1747-L552 and 1747-L553) Introduction Read this document

More information

OUTLINE. SPI Theory SPI Implementation STM32F0 SPI Resources System Overview Registers SPI Application Initialization Interface Examples

OUTLINE. SPI Theory SPI Implementation STM32F0 SPI Resources System Overview Registers SPI Application Initialization Interface Examples SERIAL PERIPHERAL INTERFACE (SPI) George E Hadley, Timothy Rogers, and David G Meyer 2018, Images Property of their Respective Owners OUTLINE SPI Theory SPI Implementation STM32F0 SPI Resources System

More information

Configuring Interfaces

Configuring Interfaces CHAPTER 4 This chapter describes how to configure interfaces for the Catalyst 4500 series switches. It also provides guidelines, procedures, and configuration examples. This chapter includes the following

More information

Global Interface Commands on Cisco IOS XR Software

Global Interface Commands on Cisco IOS XR Software Global Interface Commands on Cisco IOS XR Software This module provides global command line interface (CLI) commands for configuring interfaces on the Cisco CRS Router. HR-613 bandwidth (global) Global

More information

Shared Access Networks. Media Access Protocols. Ethernet (802.3) Ethernet cont...

Shared Access Networks. Media Access Protocols. Ethernet (802.3) Ethernet cont... Media Access Protocols Kameswari Chebrolu Dept. of Electrical Engineering, IIT Kanpur Shared Access Networks More than two nodes are attached to the same physical medium Normally span a small geographical

More information

Direct Connect and Dial-Up Connection on Windows 2000 Operating Systems

Direct Connect and Dial-Up Connection on Windows 2000 Operating Systems Application Note Issue Date March 6, 2003 Direct Connect and Dial-Up Connection on Windows 2000 Operating Systems Direct Connect and Dial-Up Connection on Windows 2000 Operating Systems...2 Introduction...

More information

APPLICATION NOTE JC/85

APPLICATION NOTE JC/85 Metasys Network Technical Manual 636 App. Notes: Network Communications Section Application Note Issue Date 0401 APPLICATION NOTE JC/85 Gateway Introduction Page 3 Application Details *3 Hardware and Software

More information

Metasys System Extended Architecture

Metasys System Extended Architecture Product Bulletin Issue Date March 31, 2003 Metasys System Extended Architecture The architecture of the Metasys building automation and facilities management system has been extended to be fully compatible

More information

Peripheral Component Interconnect - Express

Peripheral Component Interconnect - Express PCIe Peripheral Component Interconnect - Express Preceded by PCI and PCI-X But completely different physically Logical configuration separate from the physical configuration Logical configuration is backward

More information

Vanguard Managed Solutions

Vanguard Managed Solutions Vanguard Managed Solutions Vanguard Applications Ware Serial Feature Protocols Siemens HDLC Protocol Notice 2003 Vanguard Managed Solutions, LLC 575 West Street Mansfield, Massachusetts 02048 (508) 261-4000

More information

Metasys System Extended Architecture Overview

Metasys System Extended Architecture Overview Technical Bulletin Issue Date March 31, 2003 Metasys System Extended Architecture Overview Metasys System Extended Architecture Overview...2 Introduction... 2 Key Concepts... 4 Metasys System Extended

More information

William Stallings Data and Computer Communications. Chapter 7 Data Link Control

William Stallings Data and Computer Communications. Chapter 7 Data Link Control William Stallings Data and Computer Communications Chapter 7 Data Link Control Flow Control Ensuring the sending entity does not overwhelm the receiving entity Preventing buffer overflow Transmission time

More information

ISDN Commands CHAPTER

ISDN Commands CHAPTER CHAPTER 10 ISDN Commands This chapter describes the commands available to configure your router for Integrated Services Digital Network (ISDN) operations. For ISDN configuration information and examples,

More information

CSCI-1680 Link Layer Wrap-Up Rodrigo Fonseca

CSCI-1680 Link Layer Wrap-Up Rodrigo Fonseca CSCI-1680 Link Layer Wrap-Up Rodrigo Fonseca Based partly on lecture notes by David Mazières, Phil Levis, John Janno< Administrivia Homework I out later today, due next Thursday, Sep 25th Today: Link Layer

More information

ETH. Ethernet MAC with Timestamp Extension. TCD30xx User Guide. Revision July 17, 2015

ETH. Ethernet MAC with Timestamp Extension. TCD30xx User Guide. Revision July 17, 2015 TCD30xx User Guide ETH Ethernet MAC with Timestamp Extension Revision 1.0.0-41582 July 17, 2015 Copyright 2015, TC Applied Technologies. All rights reserved. LIST OF TABLES... 16-3 LIST OF FIGURES... 16-4

More information

Lab - Exploring Router Physical Characteristics

Lab - Exploring Router Physical Characteristics Topology Objectives Part 1: Examine Router External Characteristics Part 2: Examine Router Internal Characteristics Using Show Commands Background / Scenario In this lab, you will examine the outside of

More information

Troubleshooting Input Drops on ATM Router Interfaces

Troubleshooting Input Drops on ATM Router Interfaces Troubleshooting Input Drops on ATM Router Interfaces Document ID: 8625 Contents Introduction Prerequisites Requirements Components Used Conventions Traditional Reasons for Input Drops Understanding Throttles

More information

Transient Traffic Interruption on Ports Due to Source MAC Address Attacks Troubleshooting. Table of Contents

Transient Traffic Interruption on Ports Due to Source MAC Address Attacks Troubleshooting. Table of Contents Table of Contents Chapter 1 Transient Traffic Interruption on Ports Due to Source MAC Address Attacks Troubleshooting... 1-1 1.1 Symptom... 1-1 1.2 Related Information... 1-1 1.3 Diagnosis... 1-2 1.4 Troubleshooting...

More information

Buffered Distributor Proposal. Gigabit. (a.k.a. Full Duplex Repeater) (a.k.a. Buffered Repeater) Packet Engines. Bernard Daines

Buffered Distributor Proposal. Gigabit. (a.k.a. Full Duplex Repeater) (a.k.a. Buffered Repeater) Packet Engines. Bernard Daines Gigabit Buffered Distributor Proposal (a.k.a. Full Duplex Repeater) (a.k.a. Buffered Repeater) Bernard Daines Packet Engines (59) 922-919 FAX (59) 922-9185 bernardd@packetengines.com Mailing Address Shipping

More information

CSCI-1680 Link Layer Wrap-Up Rodrigo Fonseca

CSCI-1680 Link Layer Wrap-Up Rodrigo Fonseca CSCI-1680 Link Layer Wrap-Up Rodrigo Fonseca Based partly on lecture notes by David Mazières, Phil Levis, John Janno< Administrivia Homework I out later today, due next ursday, Sep 27th Today: Link Layer

More information

Metasys Integrator Northern Application

Metasys Integrator Northern Application Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date 0900 APPLICATION NOTE Metasys Integrator Northern Application lntroduction Page *3 Application Details

More information

Metasys System Configuration Tool (SCT)

Metasys System Configuration Tool (SCT) Product Bulletin Issue Date March 31, 2003 Metasys System Configuration Tool (SCT) As an integral part of the Metasys system extended architecture, the System Configuration Tool (SCT) supports the engineering,

More information

To access the web page for Cisco Desktop Collaboration Experience, perform these steps.

To access the web page for Cisco Desktop Collaboration Experience, perform these steps. Access Web Page for Cisco Desktop Collaboration, page 1 Enable and Disable Web Page Access, page 2 Device Information, page 3 Network Setup, page 4 Network Statistics, page 9 Device Logs, page 12 Streaming

More information

Data Link Protocols. High Level Data. Control Protocol. HDLC Framing ~~~~~~~~ Functions of a Data Link Protocol. Framing PDUs. Addressing Destination

Data Link Protocols. High Level Data. Control Protocol. HDLC Framing ~~~~~~~~ Functions of a Data Link Protocol. Framing PDUs. Addressing Destination Data Link Protocols Data Link Services Connection-less services Functions of a Data Link Protocol Framing PDUs ing Destination Error Detection / Error Recovery Link Management Ethernet (covered elsewhere)

More information

Peter, Please approve us apply a new ISP connection to separate with CCA for ccahalmar. The bandwidth is 100M.

Peter, Please approve us apply a new ISP connection to separate with CCA for ccahalmar. The bandwidth is 100M. All test are done in business time. Our testing are not professional. Not like ZBRELLA using www.speedtest.net as professional test. All testing report followed after. 1 From ISP s test shows the connection

More information

Modbus Remote Communication Protocol for REM 54_. Technical Description

Modbus Remote Communication Protocol for REM 54_. Technical Description Modbus Remote Communication Protocol for REM 54_ 1MRS 750781-MUM Issued: 08.03.2002 Version: A/18.06.2002 Checked: ML Approved: AF Remote Communication Protocol for REM 54_ Modbus We reserve the right

More information

The MAC Address Format

The MAC Address Format Directing data is what addressing is all about. At the Data Link layer, this is done by pointing PDUs to the destination MAC address for delivery of a frame within a LAN. The MAC address is the number

More information

CS61C Machine Structures Lecture 37 Networks. No Machine is an Island!

CS61C Machine Structures Lecture 37 Networks. No Machine is an Island! CS61C Machine Structures Lecture 37 Networks April 24, 2006 John Wawrzynek Page 1 No Machine is an Island! Computer Processor (active) Control ( brain ) Datapath ( brawn ) Memory (passive) (where programs,

More information

SCA Transport Protocol Driver

SCA Transport Protocol Driver SCA Transport Protocol Driver No:01-005 Introduction This report provides a detailed, technical description of the wireless modem s transport protocol driver developed for Mobile Data Computer Systems

More information