8.2 R5 Series (UL 508) Non-Fusible 16 80A. 8.4 MTS Manual Transfer/Double Throw Switches
|
|
- Darleen Parks
- 6 years ago
- Views:
Transcription
1 . Introduction UL/CSA Standards for Disconnect Switches UL Standards for Electrical Machinery Eaton Solutions for UL 50A and NFPA R5 Series (UL 50) Non-Fusible 6 0A Product Description Features, Benefits and Functions Standards and Certifications Product Identification Product Selection Accessories Technical Data and Specifications Dimensions R9 Series (UL 9) Non-Fusible 30 00A Compact Non-Fusible 00 00A Fusible 30 00A DC Rated Disconnects MTS Manual Transfer/Double Throw Switches Product Description Standards and Certifications Product Identification Product Selection Accessories Technical Data and Specifications Dimensions Learn Online V5-T- V5-T- V5-T-3 V5-T-5 V5-T-5 V5-T-5 V5-T-5 V5-T-6 V5-T-6 V5-T-9 V5-T-0 V5-T- V5-T- V5-T-6 V5-T-5 V5-T-5 V5-T-5 V5-T-5 V5-T-53 V5-T-5 V5-T-56 V5-T-57 Volume 5 Motor Control and Protection CA000006E December 03 V5-T-
2 . Introduction UL/CSA Standards for Disconnect Switches UL 9 Enclosed and Deadfront Switches (CSA C. No. ) These requirements cover enclosed or deadfront switches, with or without provision for fuses, at 600V or less. These products are used as disconnecting means without restrictions; they are heavy-duty products requiring.00 inches (50.0 mm) minimum of creepage distance between phases, which gives maximum safety for users and installation. The short-circuit withstand of those products goes up to 00 ka. UL 9 Molded Case Switches (CSA C. No. 5) These requirements cover molded case circuit breakers, molded case switches and fused molded case switches, rated at 600V or less and 6000A or less. Typical Control Panel UL 9 or UL 9 Non-Fusible Disconnect Switches or Fusible Disconnect Switches UL 50 Non-Fusible Switches Contents Description Introduction Eaton Solutions for UL 50 and NFPA UL Standards for Electrical Machinery UL 50 Industrial Control Equipment (CSA C. No. ) These requirements cover manual, magnetic and solidstate starters and controllers, overload relays, pushbuttons, selector switches and control lights. These products are smaller, requiring only a creepage distance between phases of 0.50 inch (.7 mm). Their use as a disconnecting means is limited to local disconnection of motors. These products can be used as a disconnect means only when they have been additionally tested suitable as motor disconnect. This additional testing ensures that the switch has a proper closing capacity on a short circuit. UL 50 devices cannot be used as main disconnect of an electrical panel, for example, at the entrance of control panels. A manual motor controller marked suitable as motor disconnect shall be installed only on the load side of the branch circuit protective device [UL 50A and NEC (6)]. Page V5-T-3 NFPA 79 Electrical Standard for Industrial Machinery The following types of machines are identified as industrial machinery: Metalworking machine tools, including machines that cut or form metal Plastics machinery Wood machinery, including woodworking, laminating and sawmill machines Assembly machines Material handling machines, including industrial robots and transfer machines Inspection and testing machines, including coordinate measuring and in-process gauging machines V5-T- Volume 5 Motor Control and Protection CA000006E December 03
3 Introduction. Eaton Solutions for UL 50A and NFPA 79 The changes in UL 50A and NFPA 79 impact the design and construction of your equipment. Important modifications concern major safety issues, the disconnect means and the interlocking of the enclosure door. The disconnect shall be operable independent of the door position. The disconnect must be operable, by qualified persons, independent of the door position without the use of accessory tools or devices. Note: NFPA 79; Paragraph (5) T. An operating mechanism for the disconnecting means shall be operable independent of the door position without the use of accessory tools or devices. Note: UL 50A; Paragraph c. The disconnect means is not closable with the enclosure door open, unless an interlock is operated by deliberate action. The interlocking means shall fulfill the following requirement: Prevent closing of the disconnect means while the enclosure door is open, unless an interlock is operated by deliberate action. Note: NFPA 79; Paragraph The disconnecting means is not closable with the enclosure door open, unless an interlock is operated by deliberate action. Note: UL 50A; Paragraph Operable independent of the position of the door Door closed: operation with the external handle through the door. Operated by a deliberate action Push Door open: It is necessary to push the handle from OFF to ON. This deliberate action permits the operator to turn and switch ON. This action is necessary as in most cases there is no padlock on the switch when somebody opens the door of an enclosure. Door open: A robust optional kit with a handle directly fitted on the shaft of the switch allows the operation when the door is open. Turn ON to OFF action permits the operator to turn and switch ON. That is a major safety issue; switching ON directly without any other action is extremely dangerous. The use of a padlock does not comply with the request of the standard; when the panel door is opened, there is generally no padlock, and anybody can turn the switch ON. Volume 5 Motor Control and Protection CA000006E December 03 V5-T-3
4 . Introduction The disconnect means shall be able to be locked in the OPEN position independent of the door position. The circuit disconnecting device shall be provided with a permanent means, permitting it to be locked in the OFF position only independent of the door position. When locked, remote as well as local closing shall be prevented. Note: NFPA 79; Paragraph (3). An operating mechanism for the disconnecting means shall be able to be locked in the OFF position independent of the door position. When locked, closing of the disconnect is not possible. Note: UL 50A; Paragraph d. The interlocking of the enclosure door shall be provided with means to defeat the interlock without removing the power. The interlocking means required by shall be provided with all of the following: Means to defeat the interlock without removing power, and requires the use of a tool to operate Reactivated automatically when all the doors are closed Note: Added effective March, 007. UL 50A; Paragraph NFPA 79; Paragraph states that the [enclosure] interlocking means shall meet the following requirements: Use a device or tool to allow qualified persons to defeat the interlock Be reactivated automatically when the door is closed Locked in the open position independent of the door position Door close: The external throughthe-door handle is padlocked when locked closing of the disconnect is not possible. Door open: A strong metallic padlock kit allows up to three padlocks. The padlocking means is easily accessible, when locked closing of the disconnect is not possible. Defeat the interlock without removing the power A tool allows defeat of the interlock without removing power. The interlocking is reactivated automatically when the door is closed. V5-T- Volume 5 Motor Control and Protection CA000006E December 03
5 R5 Series (UL 50) Non-Fusible 6 0A. R5 Series Non-Fusible 6 0A Product Description R5 Series (UL 50 listed) products are manually operated modular switches. Load break switching and isolation provide safety solutions for any low voltage circuit, particularly for machine and control circuits. The R5 Series products are manual motor controllers suitable as motor disconnect. Features, Benefits and Functions Up to 65 kaic short-circuit rating Direct or external operation Compact footprint DIN rail or base mount Wide range of accessories Up to eight-pole or four-pole MTS Open and enclosed devices Modular design Integrated terminals for additional safety Padlockable design (direct, toggle and external handles) Product can be reverse fed Standards and Certifications Conformity to Standards UL 50 listed, Guide NLRV, File E6550 CSAT C. No., File 7736 IEC , EN CCC CE Contents Description R5 Series Non-Fusible 6 0A Product Selection Accessories Technical Data and Specifications Dimensions Product Identification External front handle Shaft extension for external handle 3 Direct handle Switched fourth-pole module 5 Terminal shroud 6 Auxiliary contacts Note: For further details, please see the installation instructions supplied with each device. 3 5 Page V5-T-6 V5-T-6 V5-T-9 V5-T-0 6 Volume 5 Motor Control and Protection CA000006E December 03 V5-T-5
6 . R5 Series (UL 50) Non-Fusible 6 0A Product Selection Direct Operation R5 Series Ampere Rating Accessories Switch body + Direct handle Switch body + Shaft + External handle Three-Pole Toggle Switch Only Notes Toggle version includes direct handle. Includes shaft and accessory cap. Three-Pole Rotary Switch Only Direct Handle Front and Right External Handle SH00 (Choose one) T5A3030U T5A300U R5A306U R5A305U R5A3030U R5A300U DHR5 SH00 Black 3R, SHB00N SH00 60 T5B3060U R5B3060U Red 3R, 0 T5B300U R5B300U SHR00N Ampere Rating Switched Fourth-Pole Module Auxiliary Contacts (Choose one) External Operation Terminal Shrouds SPR56 SPR55 SPR530 NO + NC ACNONC P TSR5A 3P 0 SPR50 NO TS3R5A ACN0 60 P 0 TSR5B 3P TS3R5B SH00 Black, X SHB00NX SH00 Red, X SHR00NX Door Mounting Kit DMK Front and Right External Handle SH0 (Choose one) SH0 Black 3R, SHB0N SH0 Red 3R, SHR0N SH0 Black, X SHB0NX SH0 Red, X SHR0NX Shaft for SH0 and SH00 5 x 5 mm In (mm).0 (55.5) SF55SH5X (90.0) SF90SH5X (50.0) SF50SH5X (00.0) SF00SH5X5.60 (30.0) SF30SH5X5 V5-T-6 Volume 5 Motor Control and Protection CA000006E December 03
7 R5 Series (UL 50) Non-Fusible 6 0A. Handles Direct Handle Size 00 Handle Size 0 Handle Shafts Shaft 5 x 5 Direct Handle Ampere Rating Handle Color Catalog Number 6 0 Black DHR5 Door Interlocked External Handle (Defeatable) Ampere Rating Handle Color Handle Size NEMA Type Rating Catalog Number Front and Right Side Operation I Black SH00 3R, SHB00N 6 0 Black SH00, X SHB00NX 6 0 Red/Yellow SH00 3R, SHR00N 6 0 Red/Yellow SH00, X SHR00NX 6 0 Black SH0 3R, SHB0N 6 0 Black SH0, X SHB0NX 6 0 Red/Yellow SH0 3R, SHR0N 6 0 Red/Yellow SH0, X SHR0NX Shaft Extensions for External Handle Description Ampere Rating Use with Handle Type Standard lengths: 55 mm, 90 mm, 50 mm, 00 mm, 30 mm For 3/-pole switches: shafts are for external front and side handle For 6/-pole switches and changeover switches: shafts are for external front and side handle Guide Cone Description Ampere Rating Use with Handle Type Catalog Number The guide cone facilitates an easier 6 0 SH00 and SH0 SFGAB connection between the shaft and a Size 00 or Size 0 external selector handle. It allows the shaft up to 0 mm of vertical play when making the connection Note Allows door to be opened when switch is in the ON position. Shaft Length In (mm) Catalog Number 6 0 SH00/SH0.7 (55.0) SF055SH5X5 6 0 SH00/SH0 3.5 (90.0) SF090SH5X5 6 0 SH00/SH0 5.9 (50.0) SF50SH5X5 6 0 SH00/SH0 7.7 (00.0) SF003H5X5 6 0 SH00/SH0.60 (30.0) SF30SH5X5 Volume 5 Motor Control and Protection CA000006E December 03 V5-T-7
8 . R5 Series (UL 50) Non-Fusible 6 0A Additional Pole Configurations Switched Fourth-Pole Module Auxiliary Contact Configurations Switched Fourth-Pole Module Description Ampere Rating Number of Poles Type Catalog Number Add one or two poles and transform: 6 Switched SPR56 Three-pole R5 Series load break switch into a four-pole 5 Switched SPR55 Six-pole R5 Series switch into 30 Switched SPR530 an eight-pole Three-pole changeover switch into a four-pole 0 Switched SPR50 Auxiliary Contact Module Description Ampere Rating Type Catalog Number Early-break/same-make and signalization of positions 0 and I by NO + NC or NO auxiliary contacts. They can be mounted on the left or on the right side of the device. Two modules maximum. Terminal Shrouds Description Ampere Rating Number of Poles Position Catalog Number Line and load protection against direct contact with the terminals or connection parts: single- or three-pole. Advantage: Perforations allowing thermographic inspection. Door/Panel Mounting Kit Description Ampere Rating Number of Poles Catalog Number This kit enables direct mounting of the switch on the door panel. Moreover, the connection clamps of the switch are always accessible. The external handle is quick and easy to install due to an internal locking nut mounted on the inside of the enclosure. Note Includes shaft and accessory cap. 6 0 NO + NC ACN0NC 6 0 NO ACNO 6 0 Line and load TSR5A Line and load TS3R5A 60 0 Line and load TSR5B Line and load TS3R5B and DMK V5-T- Volume 5 Motor Control and Protection CA000006E December 03
9 R5 Series (UL 50) Non-Fusible 6 0A. Technical Data and Specifications UL 50 (CSA. No. ) Manual Motor Controller Suitable as Motor Disconnect from 6 0A Technical Characteristics 6A 5A 30A 0A 60A 0A Approvals Short-circuit rating at 600 Vac (ka) Branch circuit fuse type Maximum fuse rating IEC Characteristics UL 50/CSA. No. 0/65 J 60/30A UL 50/CSA. No. 0/65 J 60/30A Maximum UL Horsepower Ratings/Maximum Motor FLA Current, Three-Phase 0 Vac 0 0 Vac 0 0 Vac 600 Vac Connection Wire range (AWG), solid, single cable Wire range (AWG), solid, two cables Wire range (AWG), stranded, single cable Wire range (AWG), stranded, two cables 3/0.6 5/5 0/ 0/ # #0 x # # # x (# #) 7.5/. 7.5/ 5/ 0/ # #0 x # # # x (# #) UL 50/CSA. No. 0/65 J 60/30A 7.5/. 7.5/ 5/ 0/ # #0 x # # # x (# #) Notes Short-circuit rating achieved when used with respective fuse type and maximum fuse rating. A/B: Category with index A = frequent operation; category with index B = infrequent operation. 3 The power value is given for information only; the current values vary from one manufacturer to another. De-rate % per C above 0 C, max. 70 C. 5 For a rated operating voltage, U e = 00 Vac. UL 50/CSA. No. 0/65 J 60/30A 7.5/. 7.5/ 0/7 5/7 # #0 x # # # x (# #) UL 50/CSA. No. 50/65 J 00/60A 5/6. 5/ 30/0 30/3 # #0 x # # # x (#0 #6) Mechanical Characteristics Endurance, number of mechanical cycles 0,000 0,000 0,000 0,000 0,000 0,000 Auxiliary Contacts Electrical characteristics A300 A300 A300 A300 A300 A300 UL 50/CSA. No. 50/65 J 00/60A 5/6. 0/5 0/5 0/ # #0 x # # # x (#0 #6) Technical Characteristics 6A 5A 3A 0A 63A 0A Rated Operational Currents I e (A) Rated Voltage Load Duty Category A/B A/B A/B A/B A/B A/B 500 Vac AC- A/AC- B 6/6 5/5 3/3 0/0 63/63 0/0 500 Vac AC-3 A/AC-3 B 6/6 5/5 5/5 5/5 63/63 63/ Vac AC- A/AC- B 6/6 5/5 3/3 0/0 63/63 0/0 690 Vac AC- A/AC- B 6/6 5/5 3/3 3/0 0/63 63/0 690 Vac AC-3 A/AC-3 B 6/6 5/5 5/5 5/5 0/0 0/0 Thermal Current I th at 0 C (A) Thermal current I th (0 C) Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) Operational Power in AC-3 (kw) At 00 Vac without prebreaking AC in AC-3 (kw) At 500 Vac without prebreaking AC in AC-3 (kw) At 690 Vac without prebreaking AC in AC-3 (kw) Fuse Protected Short-Circuit Withstand (ka rms Prospective) Prospective short-circuit current (ka rms) Associated fuse rating (A) Overload Capacity (U e 5 Vac) Rated short-time withstand current 0.3 s. I CW (ka rms) Rated short-circuit making capacity Icm (ka peak) Connection Minimum Cu cable cross section (mm ) Maximum Cu cable section (mm ) Tightening torque minimum/maximum (Nm) /. /. /. /. 3.5/ /3.5 Volume 5 Motor Control and Protection CA000006E December 03 V5-T-9
10 . R5 Series (UL 50) Non-Fusible 6 0A Dimensions Approximate Dimensions in Inches (mm) R5 Series 6 0A Toggle Operation 90 External Front Operation.5 (37.0) Door Drilling SH00/SH0 With Fixing Nut Notes 3.9 (.0).7 (73.0).5 (6.0).97 (50.0) 0. (6.0) G E.6 (6.0) 0.35 (.) F M5 3.9 (.0).5 (6.0).99 (50.6).96 (50.0) With Four Fixing Screws One switched fourth-pole module (one per device maximum) or one unswitched neutral pole or one auxiliary contact. Maximum four additional blocks. F M T 0.3 (6.0) F N AC 0.35 (.) Direct Operation with Handle.95 (75.0).5 (6.0).97 (50.0) 0. (6.0) External Side Operation G.6 (6.0) Operating Handle SH00/SH0 Front and Right Side Operation J F M 0.35 (.) F F T M5 G.67 (6.0) 0.35 (.) N D AC 0.35 (.) F M5 F M T F. (36.0) Ø.79 (Ø7.0) N AC 0.35 (.) R5 Series Overall Dimensions Terminal Shrouds Switch Body Switch Mounting Connection Terminal Ampere Rating D Min. D Max. E Min. E Max. AC F F G J M N T 6 0. (30.0) 9.5 (35.0) 3.9 (00.0).65 (37.0).33 (0.0).77 (5.0) 0.59 (5.0).6 (6.0) 0.59 (5.0). (30.0).95 (75.0) 0.59 (5.0) (30.0) 9.5 (35.0) 3.9 (00.0).65 (37.0).33 (0.0).06 (5.5) 0.69 (7.5).99 (76.0) 0.69 (7.5).3 (35.0) 3.35 (5.0) 0.69 (7.5) 0.53 (3.5) 0. (3.0) Ø0.9 (.5).57 (0.0) Ø. (3.0) 0.6 (.0) Ø0. (7.0).0 (.0) I 90º 0º Front Operation for R5 Changeover Switches I 0 II or I I+II II II I 90º 90º V5-T-0 Volume 5 Motor Control and Protection CA000006E December 03
11 R9 Series (UL 9).3 Non-Fusible 30 00A Compact Contents Description Non-Fusible 30 00A Compact Product Selection Technical Data and Specifications Dimensions Non-Fusible 00 00A Fusible 30 00A DC Rated Disconnects Page V5-T- V5-T-5 V5-T-6 V5-T- V5-T-6 V5-T-5 Non-Fusible 30 00A Compact Product Description The R9 Series (UL 9 listed) non-fusible 30 00A compact range ensures making or breaking on load and safety isolation for low voltage electrical circuits, particularly for machine control circuits up to 600V. Features, Benefits and Functions Rating three-pole from 30A to 00A Direct or external operation handle (padlockable in ON position) Double breaking per phase Standards and Certifications UL 9, File E59 CSAT. No., File 7736 IEC EN CE Product Identification Direct handle Door interlocked external handle 3 Shaft extension Terminal shrouds 5 Unswitched neutral pole 6 Switch body 7 Switched fourth-pole module Modular type auxiliary contacts 3 Note: For further details, please see the installation instructions supplied with each device. Volume 5 Motor Control and Protection CA000006E December 03 V5-T-
12 .3 R9 Series (UL 9) Product Selection Direct Operation R9 Series 30 00A Ampere RatingNumber (Frame) of Poles 30 (C-Frame) 60 (C-Frame) 00 (C-Frame) Switch Body Only Direct Handle Front and Right External Handle SH00 (Choose one) SH00 Black, X SHB00NX SH00 Red X SHR00NX External Operation Switch body + Direct handle Switch body + Shaft + External handle Front and Right External Handle SH0 (Choose one) Shaft for SH0 and SH00 Handles In (mm) (Choose one) Switched Fourth-Pole Module 3 R9C3030U DHR9 SH00 Black SH0 Black.0 (55.5) SF55SH5X5 SPR930 3 R9C3060U 3R, 3R, SHB00N SHB0N 3.50 (90.0) SPR960 SF90SH5X5 3 R9C300U SH00 SH0 SPR900 Red 3R, SHR00N Red 3R, SHR0N 5.9 (50.0) SF50SH5X5 SH0 Black, X SHB0NX SH0 Red X SHR0NX 7.7 (00.0) SF00SH5X5.60 (30.0) SF30SH5X5 Auxiliary Contacts (Choose one) NO + NC ACNONC NO ACN0 Terminal Shrouds (Choose one) P TSR9 3P TS3R9CV V5-T- Volume 5 Motor Control and Protection CA000006E December 03
13 R9 Series (UL 9).3 Handles Direct Handle Size 00 Handle Size 0 Handle Shafts Shaft 5 x 5 SFGAB Direct Handle Ampere Rating Handle Color Catalog Number Black DHR9 Door Interlocked External Handle Ampere Rating Handle Color Handle Size NEMA Type Rating Catalog Number Front and Right External Handle Black SH00 3R, SHB00N Black SH00, X SHB00NX Red SH00 3R, SHR00N Red SH00, X SHR00NX Black SH0 3R, SHB0N Black SH0, X SHB0NX Red SH0 3R, SHR0N Red SH0, X SHR0NX Shaft Extensions for External Handle Description Ampere Rating Use with Handle Type Standard lengths: 55 mm, 90 mm, 50 mm, 00 mm, 30 mm Shafts are for external front and right side handles Guide Cone Description Ampere Rating Use with Handle Type Catalog Number The guide cone facilitates an easier connection between the shaft and a Size 00 or Size 0 external selector handle. It allows the shaft up to 0 mm of vertical play when making the connection Note Allows door to be opened when switch is in the ON position. Shaft Length In (mm) Catalog Number SH00/SH0.0 (55.5) SF55SH5X SH00/SH (90.0) SF90SH5X SH00/SH0 5.9 (50.0) SF50SH5X SH00/SH0 7.7 (00.0) SF00SH5X SH00/SH0.60 (30.0) SF30SH5X5 6 0 SH00 and SH0 SFGAB Volume 5 Motor Control and Protection CA000006E December 03 V5-T-3
14 .3 R9 Series (UL 9) Additional Pole Configurations Auxiliary Contact Configurations Switched Fourth-Pole Module Description Ampere Rating Number of Poles Type Catalog Number Transforms a three-pole, R9 Series load break switch into a four-pole 30 Switched SPR Switched SPR Switched SPR900 Auxiliary Contacts Description Ampere Rating Type Catalog Number Early-break/same-make and signalization of positions 0 and I by NO + NC or NO auxiliary contacts. They can be mounted on the left or on the right side of the device. Maximum four auxiliary contacts (two modules) NO + NC ACN0NC NO ACNO Terminal Shrouds Description Ampere Rating Number of Poles Position Catalog Number Line and load protection against direct contact with the terminals or connection parts: single- or three-pole Advantage: Perforations allowing thermographic inspection Line and load TSR Line and load TS3R9CV V5-T- Volume 5 Motor Control and Protection CA000006E December 03
15 R9 Series (UL 9).3 Technical Data and Specifications UL and CSA Characteristics UL 9/CSA. No. Technical Characteristics 30A 60A 00A Short-circuit rating at 0 Vac (ka) 00 ka 00 ka 00 ka Short-circuit rating at 600 Vac (ka) 00 ka 00 ka 5 ka Fuse type J J J Maximum fuse rating (A) Maximum Horsepower Rating/Maximum Motor FLA Three-Phase 0 0 Vac 0/ 0/5 0/5 0 0 Vac 0/7 0/5 50/ Vac 5/7 50/5 50/5 Maximum Horsepower Rating/Maximum Motor FLA Single-Phase 0 Vac / 3/3 5/56 0 Vac 5/ 0/50 0/50 Connection Solid, wire # 0 # 0 # 0 Stranded, wire # /0 # /0 # /0 Auxiliary Contacts Electrical characteristic A300 A300 A300 IEC Characteristics Technical Characteristics 3A 63A 00A Thermal Current I th at 0 C (A) Thermal current I th (0 C) Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) Rated Operation Currents I e (A) Load Duty Category Rated Voltage A A A 00 Vac AC-A Vac AC-3A Vac AC-A Vac AC-3A Operational Power in AC-3 (kw) At 00 Vac without prebreak AC in AC-3 (kw) At 500 Vac without prebreak AC in AC-3 (kw) At 690 Vac without prebreak AC in AC-3 (kw) Overload Capacity (U e 5 Vac) Rated short-time making capacity I cm (ka peak) 5 Connection Minimum Cu cable cross section (mm ) Maximum Cu cable section (mm ) Notes Short-circuit rating achieved when used with respective fuse type and maximum fuse rating. Category with index A = frequent operation. 3 A/B: Category with index A = frequent operation; category with index B = infrequent operation. The power value is given for information only; the current values vary from one manufacturer to another. 5 For a rated operating voltage, U e = 00 Vac. Volume 5 Motor Control and Protection CA000006E December 03 V5-T-5
16 .3 R9 Series (UL 9) Dimensions Approximate Dimensions in Inches (mm) R9 Series 30 00A Compact Direct Operation.95 (75.0).5 (6.0).0 (6.0) 3.07 (7.0).9 (.6) 0.35 (.) 6.00 (660.) 5.7 (3.) 0.35 (.) 7. (9.0).09 (53.0) 0. (6.0).0.0 (6.0) (6.0) M5.0 (6.0) External Front Operation.6 (37.0) 3.9 min. (00.0).65 max. (37.0) 3.9 (.0).5 (6.0).99 (50.6) External Side Operation.9 (.6).0 (6.0) 0.5 (3.0) 3.07 (7.0). min. (30.0) 7.9 max. (0.0) 5.7 (3.) 7. (9.0) Ø.0 (7.0) 3.6 (.0) Notes One switched fourth-pole module (one per device maximum) and/or one unswitched neutral pole. Auxiliary contact..09 (53.0) 0. (6.0) 0.35 (.).0 (6.0) M5.0 (6.0) 0.35 (.).0 (6.0) V5-T-6 Volume 5 Motor Control and Protection CA000006E December 03
17 R9 Series (UL 9).3 Approximate Dimensions in Inches (mm) Door Drilling SH00/SH0 With Fixing Nut 0.53 (3.5) Operating Handle SH00/SH0 Front and Right Side Operation I 90º 0º 0. (3.0) Ø0.9 (.5) With Four Fixing Screws.57 (0.0) Ø. (3.0) 0.6 (.0) Ø0. (7.0).0 (.0) Volume 5 Motor Control and Protection CA000006E December 03 V5-T-7
18 .3 R9 Series (UL 9) Non-Fusible 00 00A Contents Description Non-Fusible 30 00A Compact Non-Fusible 00 00A Product Selection Accessories Technical Data and Specifications Dimensions Fusible 30 00A DC Rated Disconnects Page V5-T- V5-T-9 V5-T-0 V5-T- V5-T-3 V5-T-6 V5-T-5 Non-Fusible 00 00A Product Description The R9 Series (UL 9 listed) non-fusible 00 00A are manually operated multipole load-break switches. Quickmake, quick-break design provides safety isolation for any low voltage circuit. Features, Benefits and Functions High thermal and dynamic withstand ratings Arduous categories of applications High electrical and mechanical endurances 3 Standards and Certifications UL 9, File E59 CSAT. No., File 7736 IEC EN Product Identification External front handle Shaft extensions for external handle 3 Configurable U-type ACs, for pre-break and signalling or TEST Terminal Screens Note: For further details, please see the installation instructions supplied with each device. V5-T- Volume 5 Motor Control and Protection CA000006E December 03
19 R9 Series (UL 9).3 Product Selection Direct Operation R9 Series Non-Fusible 00 00A Ampere Rating (Frame) 00 (D-Frame) 00 (D-Frame) 00 (E-Frame) 600 (F-Frame) 00 (G-Frame) 000 (G-Frame) 00 (G-Frame) Number of Poles Switch Body Only Direct Handle Door Interlocked External Pistol Handle (Choose one) Shaft Extensions for External Handle In (mm) (Choose one) Notes Top (line side) supplied as standard. Auxiliary contact requires holder (catalog number ACHFG) when used on F and G-Frame switches (non-fusible A). 3 Each catalog number is for line or load side. For both line and load, please order two sets. FS suffix = Finger Safe. Auxiliary Contacts Terminal Screens (Choose one) Terminal Lugs 3 3 R9D300U DHR9DE Size, Black 7.90 (00.0) NO + NC 3-pole, Line side only LK3R9DL R9D00U, 3R, SF00PH0X0 ACN0NCDE TS3R9DT Defeatable ACN0NCDELL LKR9DL 3 R9D300U PHBNF.60 (30.0) 3-pole, Load side only LK3R9DL R9D00U SF30PH0X0 NO + NC TS3R9DB Size, Red ACN0NCDE LKR9DL, 3R, Defeatable 5.70 (00.0) SF00PH0X0 ACN0NCDELL -pole, Line or load side TSR9DTB PHRNF 3 R9E300U 9.70 (500.0) 3-pole, Line side only LK3R9EM Size, Black SF500PH0X0 TS3R9ET R9E00U LKR9EM, X Defeatable 3-pole, Load side only PHBNXF TS3R9EB Size, Red, X Defeatable PHRNXF 3 R9F3600U DHR9FG Size 3, Black, X Defeatable PHB3NXF -pole, Line or load side TSR9ETB 7.90 (00.0) NO AC U Type TS3R9F LK3R9FN R9F600U SF00PH5X ACN0R9 TSR9F LKR9FN 3 R9G300U.60 (30.0) NC AC U Type TS3R9FFS LK6R9G 3 3 R9G00U R9G3000U R9G000U R9G300U R9G00U SF30PH5X ACNCR9 Size 3, Red PHR3NXF Size, Black, X Defeatable PHBNXF, X.70 (00.0) Defeatable SF00PH5X TS3R9G TSR9G TS3R9GFS LKR9G Size, Red, X Defeatable PHRNXF External Operation Switch body + Direct handle Switch body + Shaft + External handle Volume 5 Motor Control and Protection CA000006E December 03 V5-T-9
20 .3 R9 Series (UL 9) Accessories Direct Handle PH and PH3 Types PH Type Shaft Extensions X Direct Handle Description Ampere Rating Handle Color Catalog Number Front operation Black DHR9DE Black DHR9FG Door Interlocked External Handle Front Operation Description Ampere Rating Switch Frame Handle Type Handle Color NEMA Type Defeatable Catalog Number The door interlocked external D/E PH Black,3R, Yes PHBNF handle includes one lockable handle and one escutcheon D/E PH Red,3R, Yes PHRNF D/E PH Black,X Yes PHBNXF For Dimensions, see Page V5-T D/E PH Red,X Yes PHRNXF F/G PH3 Black,X Yes PHB3NXF F/G PH3 Red,X Yes PHR3NXF F/G PH Black,X Yes PHBNXF F/G PH Red,X Yes PHRNXF Shaft Extensions for External Front Handle Front Operation Ampere Rating Use (Frame) Standard lengths: 00 mm, 30 mm, 00 mm, 500 mm Shaft Length Minimum Dimensions (X) Inches (mm) Ampere Rating Description (Frame) X Length Catalog Number Standard lengths: 7.90 (00.6).60 (30.0) 5.70 (39.) Note Allow the door to be opened when the switch is in (ON) position. Handle Type Shaft Length In (mm) Catalog Number (D-, E-Frame) PH 7.90 (00.0) SF00PH0X (D-, E-Frame) PH.60 (30.0) SF30PH0X (D-, E-Frame) PH 5.70 (00.0) SF00PH0X (D-, E-Frame) PH 9.70 (500.) SF500PH0X (F-, G-Frame) PH3/PH 7.90 (00.0) SF00PH5X (F-, G-Frame) PH3/PH.60 (30.0) SF30PH5X (F-, G-Frame) PH3/PH 5.70 (00.0) SF00PH5X (D-, E-Frame) ( ) 7.90 (00.6) SF00PH0X ( ).60 (30.0) SF30PH0X ( ) 5.70 (39.) SF00PH0X ( ) 9.70 (500.) SF500PH0X (F-, G-Frame) ( ) 7.90 (00.6) SF00PH5X.70.3 ( ).60 (30.0) SF30PH5X.70.3 ( ) 5.70 (39.) SF00PH5X V5-T-0 Volume 5 Motor Control and Protection CA000006E December 03
21 R9 Series (UL 9).3 Auxiliary Contacts Description Terminal Screens Line and Load Terminal Lugs Notes Early-break/same-make. Gold plated for minimal resistance for PLC applications. 3 Requires use of ACHFG auxiliary contact holder for F- and G-Frame switches. For two-hole lug, consult factory. Ampere Rating (Frame) Number of AC AC Type Catalog Number 00 00A, up to two ACs max NO / NC Standard ACNONCDE 00A, up to two ACs max. (D-, E-Frame) NO / NC Low Level ACNONCDELL A, up to four ACs max (F-, G-Frame) Auxiliary contact holder (for use with ACNOR9 and ACNCR9) Description Line and load protection against direct contact with terminals or connection parts. Line side terminal shrouds are included standard on A non-fusible switches. Shrouds are not included on the 00 00A. Description Connection of copper cables on to the terminals (no spade lugs). Each kit includes lugs for line or load side. For line and load side, order two kits. For Dimensions, see Page V5-T (F-, G-Frame) Maximum Ampere Rating (Frame) (D-Frame) 00 (E-Frame) 600 (F-Frame) (G-Frame) Maximum Ampere Rating (Frame) (D-Frame) 00 (E-Frame) 600 (F-Frame) (G-Frame) NO / NC Standard ACNONCDE NO / NC Low Level ACNONCDELL NO Standard ACNOR9 3 NC Standard ACNCR9 3 ACHFG Number of Poles Line/Load Side Catalog Number 3 Line TS3R9DT 3 Load TS3R9DB Line or load TSR9DTB 3 Line TS3R9ET 3 Load TS3R9EB Line or load TSR9ETB 3 Line or load TS3R9F Line or load TSR9F 3 Line or load TS3R9G Line or load TSR9G Number of Poles Number of Lugs/Pole Lug Capacity/Phase Cable Type Catalog Number 3 #6 300 kcmil Cu/Al LK3R9DL #6 300 kcmil Cu/Al LKR9DL 3 # 600 kcmil Cu/Al LK3R9EM # 600 kcmil Cu/Al LKR9EM 3 () # 600 kcmil Cu/Al LK3R9FN () # 600 kcmil Cu/Al LKR9FN 3 x () # 600 kcmil Cu/Al LK6R9G x () # 600 kcmil Cu/Al LKR9G Volume 5 Motor Control and Protection CA000006E December 03 V5-T-
22 .3 R9 Series (UL 9) Technical Data and Specifications UL and CSA Characteristics Technical Characteristics 00A 00A 00A 600A 00A 000A 00A Short circuit rating at 600 Vac (ka) 00 ka 00 ka 00 ka 00 ka 00 ka 00 ka 00 ka Fuse type J J J J L L L Maximum fuse rating (A) Maximum Horsepower Rating/Maximum Motor FLA Three-Phase 0 0 Vac 30/0 75/9 5/3 00/0 00/0 00/0 00/0 0 0 Vac 75/96 50/0 50/30 00/77 500/ / / Vac 00/99 00/9 350/ / /7 500/7 500/7 Maximum Horsepower Rating/Maximum Motor FLA Direct Current 5 Vdc Two-pole in series 0/76 5/ 0/ 0/ 50 Vdc Three-pole in series 5/55 5/55 50/73 50/73 Connection Minimum connection section/awg #6 #6 # x # x # x # x # Maximum connection section/awg 300 kcmil 300 kcmil 600 kcmil x 600 kcmil x 600 kcmil x 600 kcmil x 600 kcmil Auxiliary Contacts Electrical characteristics A300 A300 A300 A600 A600 A600 A600 IEC Characteristics Technical Characteristics 00A 00A 00A 600A 00A 000A 00A Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) Rated Operational Currents I e (A) Load Duty Rated Voltage Category A A A A A A A 00 Vac AC-A Vac AC-3A Vac AC-A Vac AC-3A Connection Minimum Cu cable cross section (mm ) x 50 x 5 x 0 Minimum Cu busbar section (mm ) x 30 x 5 x 0 x 5 x 50 x 5 x 60 x 5 Operational Power in AC-3 (kw) At 00 Vac without prebreaking AC in AC3 (kw) ( x 3) At 500 Vac without prebreaking AC in AC3 (kw) ( x 3) At 690 Vac without prebreaking AC in AC3 (kw) ( x 3) Overload Capacity (U e 5 Vac) Rated short-circuit making capacity Icm (ka peak) Notes Short-circuit rating achieved when used with respective fuse type and maximum fuse rating. Category with index A = frequent operation. 3 For a rated operating voltage, U i = 00 Vac. V5-T- Volume 5 Motor Control and Protection CA000006E December 03
23 R9 Series (UL 9).3 Dimensions Approximate Dimensions in Inches (mm) Front Operation D- and E-Frames R9 Series Non-Fusible 00 00A V K CA Ampere Rating (A) J T M F Overall Dimensions U W R N R AA AC H Z Y AD C The switch will operate correctly when rotated clockwise 90 degrees. The switch will not operate correctly when rotated counterclockwise 90 degrees. Terminal Shrouds Switch Body AC AD F 3P F P H J 3P J P K (9.6) 0.0 (56.0) 3.05 (77.5) 7.09 (0.0) 9.06 (30.0). (07.0).7 (55.0).3 (05.0).0 (5.6) (9.6) 0.0 (56.0) 3.05 (77.5) 7.09 (0.0) 9.06 (30.0). (07.0).7 (55.0).3 (05.0).0 (5.6) 00.9 (.0) 6.00 (06.0).5 (5.0) 9.05 (30.0).0 (90.0) 6.53 (66.0).95 (75.0) 5.3 (35.0).65 (67.5) Ampere Rating (A) Switch Mounting Connection M 3P M P N R R T U V W Y Z AA AC (60.0).7 (0.0) 5.3 (35.0) 0.35 (9.0) 0.7 (7.0).97 (50.0) 0.9 (5.0). (30.0) 0.3 (.0) 0. (3.5).35 (3.) 6.30 (60.0) 0.60 (5.0) (60.0).7 (0.0) 5.3 (35.0) 0.35 (9.0) 0.7 (7.0).97 (50.0) 0.9 (5.0). (30.0) 0.3 (.0) 0. (3.5).35 (3.) 6.30 (60.0) 0.60 (5.0) 00.6 (0.0) 0.60 (70.0) 7.67 (95.0) 0.35 (9.0) 0.7 (7.0).56 (65.0).77 (5.0).97 (50.0) 0.3 (3.0) 0.0 (5.0).0 (53.0) 0.0 (60.0) 0.0 (0.0) Volume 5 Motor Control and Protection CA000006E December 03 V5-T-3
24 .3 R9 Series (UL 9) Approximate Dimensions in Inches (mm) Front Operation F- and G-Frames R9 Series Non-Fusible 600A H Z AC R9 Series Non-Fusible 00 00A J F Y X M 3.5 (0.0) Ø0.5 (Ø3.0) N N AA The switch will operate correctly when rotated clockwise 90 degrees. The switch will not operate correctly when rotated counterclockwise 90 degrees. Terminal Screens Switch Body Switch Mounting Connection Terminals AC F 3P F P H J P J P M P M P N N AA Z. (60.0).0 (0.0).7 (360.0) 5.5 (0.0) 5.00 (7.5) 6.59 (67.5) 0.03 (55.0) 3.9 (335.0) 6.9 (75.0).3 (59.5).6 (30.0).5 (7.0) Z H AC 0.7 (9.) 0.7 (9.).57 (0.0) Ø0.3 (Ø0.9).5 (.) J.7 (9.9) M Y X F N N N The switch will operate correctly when rotated clockwise 90 degrees. The switch will not operate correctly when rotated counterclockwise 90 degrees. Terminal Screens Switch Body Switch Mounting Connection Terminals AC F 3P F P H J 3P J P M 3P M P N N N Z. (60.0).6 (37.0) 9.37 (9.0) 5.5 (0.0) 6.3 (73.5) 9.9 (33.5) 3.66 (37.0).3 (67.0) 6.9 (75.0).3 (59.5).0 (.0).5 (7.0) V5-T- Volume 5 Motor Control and Protection CA000006E December 03
25 R9 Series (UL 9).3 Approximate Dimensions in Inches (mm) Direct Handle Front Operation R9 Series Non-Fusible 00A R9 Series Non-Fusible A.57 (0.0) Door Interlocked External Handle PH Type Handle PH3 Type Handle PH Type Handle Ø3.07 (Ø7.0) Ø3.07 (Ø7.0) Ø7.00 (9.) Direction of Operation I Door Drilling Templates.57 (0.0) Ø.6 (37.0) 5.3 (35.0).9 (5.0).77 (5.0).79 (5.5) Top and Bottom Terminal Lugs.36 (60.0) 7. (90.0) R9 Series Non-Fusible 00 00A R9 Series Non-Fusible 00A R9 Series Non-Fusible A.5 (3.6) 90º 0º Ø7.0 (.0) 0.5 (Ø.).00 (5.). (.) I.57 (0.0) Ø.6 (37.0).30 (35.0).0 (6.0) 90º 0º.0 (7.5) Ø7.0 (.0) 3.35 (5.0).7 (0.0).0 (6.0) Ø 0.0 (Ø0.6) Ø.70 (Ø9.3) 0.63 (5.9) 0. (.3) I.57 (0.0) Ø.6 (37.0) 3.5 (0.0) 90º 0º Ø7.0 (.0) 3.7 (350.0).36 (60.0).9 (37.) 0.0 (Ø0.).7 (7.9) Volume 5 Motor Control and Protection CA000006E December 03 V5-T-5
26 .3 R9 Series (UL 9) Fusible 30 00A Contents Description Non-Fusible 30 00A Compact Non-Fusible 00 00A Fusible 30 00A Product Identification Product Selection Accessories Technical Data and Specifications Dimensions DC Rated Disconnects Page V5-T- V5-T- V5-T-7 V5-T- V5-T-3 V5-T-37 V5-T-39 V5-T-5 Fusible 30 00A Product Description R9 Series (UL 9 listed) Fusible 30 00A manual operated multi-pole fusible disconnect switches use double break contacts per pole that ensure complete isolation of the fuse when the switch is in the OFF position. When installed with fuses, they provide protection for low voltage electrical installations against short circuit and overload. Features, Benefits and Functions Load break functionality Double break contacts Up to 00 ka short-circuit rating with Class CC, J or L fuses Compact footprints The optional TEST position function (up to 00A) enables testing of the control circuit auxiliaries without switching the main contacts. This function provides a simple alternative to a separately wired pushbutton Defeatable pistol handles automatically re-latch when the panel door is closed Front or side operation Flange operation NFPA 79 compliant kits Two-, three- and fourpole devices Standards and Certifications UL 9, File E59 for 30 to 00A ratings UL 9, File E3053 for H-Frame switches CSA. No., File 7736 CSA. No. 5, File 7736, H-Frame only IEC 6097-, EN IEC , EN NFPA 79 V5-T-6 Volume 5 Motor Control and Protection CA000006E December 03
27 R9 Series (UL 9).3 Product Identification R9 Fusible 30A/CC and 30A/J H-Frame Direct and External Operation External front handles Direct handle 3 Shaft extensions for external handles Configurable U Type ACs, for pre-break and signaling or TEST R9 Fusible 30A/J 00A/L (I N-Frames) Direct and External Operation External front handles External right side handle (not applicable for N-Frame 600/00A) 3 Direct handle Shaft extensions for external handles 5 Configurable U Type ACs, for pre-break and signaling or TEST 6 Side auxiliary contacts 7 Terminal shrouds 7 3 Volume 5 Motor Control and Protection CA000006E December 03 V5-T-7
28 .3 R9 Series (UL 9) Product Selection Direct Operation Front and Right Side Operation Ampere Rating (Frame) (Fuse Class) 30 Compact (H-Frame) (CC) 30 (H-Frame) (CC) 30 Compact (H-Frame) (J) 30 (H-Frame) (J) 30 (I-Frame) (CC) 30 (J-Frame) (J) 60 (J-Frame) (J) Number of Poles Note 00 ka short-circuit rating. Switch Body Only Direct Handle External Selector Handle (Choose one) 3 RH3030FCC DHR9HC Black,3R, SHB0NHV Shaft Extension for Selector Handle Only (Choose one) 3 + switched neutral RH3030FCCSN ) Red SF30SH5X5H,3R, 3 RH3030FJ DHR9HJ SHR0NHV 5.70 (00.0) SF00SH5X5H 3 + switched neutral RH3030FJSN Black,X SHB0NXHV Red,X SHR0NXHV 3 R9I3030FCC DHR9JM R9I030FCC 7.90 (00.0) SF00SH5X5H External Front Pistol Handle Black,3R, PHBNF Red,3R, PHRNF Black,X PHBNXF Red,X PHRNXF R9J030FJ Black,X Black 3 R9J3030FJ (w/ TEST Position) PHBNXFT R9J030FJ R9J060FJ Red,X 3 R9J3060FJ (w/ TEST Position) PHRNXFT R9J060FJ External Operation Switch body + Direct handle Switch body + Shaft + External handle External Right Side Pistol Handle, X PHBNXS Red, X PHRNXS V5-T- Volume 5 Motor Control and Protection CA000006E December 03
29 R9 Series (UL 9).3 Front and Right Side Operation, continued Ampere Rating (Frame) (Fuse Class) 30 Compact (H-Frame) (CC) 30 (H-Frame) (CC) 30 Compact (H-Frame) (J) 30 (H-Frame) (J) 30 (I-Frame) (CC) 30 (J-Frame) (J) 60 (J-Frame) (J) Number of Poles Note 00 ka short-circuit rating. Switch Body Only 3 RH3030FCC 7.90 (00.0) SF00PH5X5 3 + switched neutral RH3030FCCSN 3 RH3030FJ 3 + switched neutral RH3030FJSN Shaft Extensions for Pistol Handle Only In (mm) NFPA (Choose one) 79 Kit.60 (30.0) SF30PH5X (00.0) SF00PH5X5 3 3 R9I3030FCC R9I030FCC R9J030FJ R9J3030FJ 7.90 (00.0) SF00PH0X0.60 (30.0) SF30PH0X0 R9J030FJ 5.70 (00.0) SF00PH0X0 R9J060FJ 3 R9J3060FJ 9.70 (500.0) SF500PH0X0 R9J060FJ NFPA79H NFPA79JKL Auxiliary Contacts (Choose one) AC NO ACNOR9 AC NC ACNCR S Type Auxiliary Contacts (Choose one) Terminal Shrouds Integral to switch AC NO + NC ACNONCJN AC NO + NC ACNONCJN AC NO + NC w/ TEST ACNONCJNT AC NO + NC w/ TEST ACNONCJNT Volume 5 Motor Control and Protection CA000006E December 03 V5-T-9
30 .3 R9 Series (UL 9) Front and Right Side Operation, continued Ampere Rating (Frame) (Fuse Class) 60 (K-Frame) (J) 00 (K-Frame) (J) 00 (L-Frame) (J) 00 (M-Frame) (J) 600 (N-Frame) (J) 00 (N-Frame) (L) Notes 00 ka short-circuit rating. Requires test handle. Number of Poles Switch Body Only Direct Handle (Black) External Front Pistol Handle (Choose one) 3 R9K060FJ R9K3060FJ R9K060FJ DHR9JM Black,3R, PHBNF 3 R9K00FJ R9K300FJ R9K00FJ Red,3R, PHRNF Black R9L00FJ,X PHBNXF 3 R9L300FJ 3 R9L00FJ R9M300FJ R9M00FJ Red,X PHRNXF Black,X (w/ TEST Position) PHBNXFT Red,X (w/ TEST Position) PHRNXFT R9N600FJ DHR9N Black 3 R9N3600FJ, X PHB3NXF R9N600FJ R9N00FL Red,X 3 R9N300FL PHR3NXF R9N00FL External Right Side Pistol Handle (Choose one) Black, X PHBNXS Red, X PHRNXS V5-T-30 Volume 5 Motor Control and Protection CA000006E December 03
31 R9 Series (UL 9).3 Front and Right Side Operation, continued Ampere Rating (Frame) (Fuse Class) 60 (K-Frame) (J) 00 (K-Frame) (J) 00 (L-Frame) (J) 00 (M-Frame) (J) 600 (N-Frame) (J) 00 (N-Frame) (L) Number of Poles Notes 00 ka short-circuit rating. Requires test handle. Switch Body Only Shaft Extensions for External Handle In (mm) (Choose one) NFPA 79 Kit Auxiliary Contacts (Choose one) Auxiliary Contacts (Choose one) Terminal Shrouds R9K060FJ 7.90 (00.0) NFPA79JKL AC AC Integral to switch 3 R9K3060FJ Pistol NO NO + NC SF00PH0X0 ACNOR9 ACNONCJN R9K060FJ R9K00FJ.60 (30.0) AC AC Pistol NC NO + NC 3 R9K300FJ R9K00FJ SF30PH0X (00.0) ACNCR9 ACNONCJN AC 3 R9L00FJ R9L300FJ R9L00FJ ACNONCJNT 9.70 (500.0) Pistol AC Pistol NO + NC SF00PH0X0 w/ TEST TSR9L TSR9L3 TSR9L 3 R9M300FJ R9M00FJ SF500PH0X0 NO + NC w/ TEST ACNONCJNT TSR9M3 TSR9M R9N600FJ 7.90 (00.0) NFPA79N AC TSR9N 3 R9N3600FJ Pistol NO + NC SF00PHX ACNONCJN TSR9N3 R9N600FJ TSR9N R9N00FL.60 (30.0) AC Pistol NO + NC TSR9N 3 R9N300FL SF30PHX ACNONCJN TSR9N3 R9N00FL 5.70 (00.0) TSR9N Pistol SF00PHX 9.70 (500.0) Pistol SF500PHX Volume 5 Motor Control and Protection CA000006E December 03 V5-T-3
32 .3 R9 Series (UL 9) Accessories NFPA 79 Compliant Mechanism for Flange Handle Flange Handle for Flange-Operated Switches Description Cable Operator Rod Operator NFPA 79 Through the Door Kit Ampere Rating Description (Frame) Note Defeatable. Ampere Rating (Frame) Handle Type NEMA Type Catalog Number For side-operated switches only (J-, K-, L-, M-Frame) Standard handle, 3, 3R,, FHS Provides heavy-duty flange style (J-, K-, L-, M-Frame) operation. Meets both UL 50A and Chrome-plated handle, 3, 3R,, X, FHCP NFPA 79 requirements. Please order cable or rod link between handle and switch. Description Link between Flange handle and side-operated switches. Please order mechanism and Flange handle. Description Link between Flange handle and side-operated switches. Mechanism included. Please order Flange handle. For front-operated switches only. Meets both UL 50A and NFPA 79 requirements. Kit includes mechanism, shaft and internal handle. Please also order a PH type external pistol handle. Ampere Rating (Frame) NEMA Type (J-, K-, L-, M-Frame) Mechanism for Flange handle Ampere Rating (Frame) For Enclosure Depth In (mm) Cable Length In (mm) CFM (9.) CFC (5.0) CFC (30.0) CFC (J-, K-, L-, M-Frame) ( ) RFM Catalog Number Catalog Number Catalog Number 30 (H-Frame) NFPA79H (J-, K-, L-, M-Frame) NFPA79JKL (N-Frame) NFPA79N V5-T-3 Volume 5 Motor Control and Protection CA000006E December 03
33 R9 Series (UL 9).3 SO Type Handle PH Type Handle PH Type Handle PH3 Type Handle Direct Handle Description Door Interlocked External Front Handles Ampere Rating Description (Frame) Handle Type NEMA Type Color Right Side External Handles Ampere Rating (Frame) Handle Type NEMA Type Color Note Includes TEST position. Ampere Rating (Frame) Fuse Catalog Number Front operation. Black. 30 (H-Frame) CC DHR9HC 30 (H-Frame) J DHR9HJ The handle locking function of the front external operation handle prevents the user from opening the door of the enclosure when the switch is in the ON position, and when the switch is padlocked in the OFF position (PH, PH and PH3 type handles only). Opening the door when the switch is in the OFF position is possible by defeating the locking function with the use of a tool (authorized persons only). The locking function is restored when the door is closed back. 30 (I-Frame) CC DHR9JM (J-, K-, L-, M-Frame) J DHR9JM (N-Frame) J/L DHR9N Standard Catalog Number 30 (H-Frame) SO, 3R, Black SHB0NHV 30 (H-Frame) SO, 3R, Red/yellow SHR0NHV 30 (H-Frame) SO, X Black SHB0NXHV 30 (H-Frame) SO, X Red/yellow SHR0NXHV (H-,I-, J-Frame) PH, 3R, Black PHBNF (H-,I-, J-Frame) PH, 3R, Red/yellow PHRNF (H-,I-, J-Frame) PH, X Black PHBNXF (H-,I-, J-Frame) PH, X Red/yellow PHRNXF (H-,I-, J-Frame) PH, X Black PHBNXFT (H-,I-, J-Frame) PH, X Red/yellow PHRNXFT (K-, L-, M-Frame) PH, 3R, Black PHBNF (K-, L-, M-Frame) PH, 3R, Red/yellow PHRNF (K-, L-, M-Frame) PH, X Black PHBNXF (K-, L-, M-Frame) PH, X Red/yellow PHRNXF (K-, L-, M-Frame) PH, X Black PHBNXFT (K-, L-, M-Frame) PH, X Red/yellow PHRNXFT (N-Frame) PH3, X Black PHB3NXF (N-Frame) PH3, X Red/yellow PHR3NXF Standard Catalog Number (J-Frame) PH, X Black PHBNXS (J-Frame) PH, X Red/yellow PHRNXS (K-, L-, M-Frame) PH, X Black PHBNXS (K-, L-, M-Frame) PH, X Red/yellow PHRNXS Volume 5 Motor Control and Protection CA000006E December 03 V5-T-33
34 .3 R9 Series (UL 9) X Shaft Extensions for External Handles Ampere Rating (Frame) Handle Type Handle Types SH and PH, X Minimum Dimensions Dimensions X Ampere Rating (Frame) In (mm) Handle Type Shaft Length In (mm) Catalog Number 30 (H-Frame) SH (00.0) SF00SH5X5H 30 (H-Frame) SH0.60 (30.0) SF30SH5X5H 30 (H-Frame) SH (00.0) SF00SH5X5H 30 (H-Frame) PH 7.90 (00.0) SF00PH5X5 30 (H-Frame) PH.60 (30.0) SF30PH5X5 30 (H-Frame) PH 5.70 (00.0) SF00PH5X (I-, J-, K-, L-, M-Frame) PH 7.90 (00.0) SF00PH0X (I-, J-, K-, L-, M-Frame) PH.60 (30.0) SF30PH0X (I-, J-, K-, L-, M-Frame) PH 5.70 (00.0) SF00PH0X (I-, J-, K-, L-, M-Frame) PH (500.0) SF500PH0X (N-Frame) PH (00.0) SF00PHX (N-Frame) PH3.60 (30.0) SF30PHX (N-Frame) PH (00.0) SF00PHX (N-Frame) PH (500.0) SF500PHX Shaft Length In (mm) Catalog Number 30 (H-Frame) ( ) SH (00.0) SF00SH5X5H 30 (H-Frame).0.37 ( ) SH0.60 (30.0) SF30SH5X5H 30 (H-Frame) ( ) SH (00.0) SF00SH5X5H 30 (H-Frame) ( ) PH 7.90 (00.0) SF00PH5X5 30 (H-Frame).0.37 ( ) PH.60 (30.0) SF30PH5X5 30 (H-Frame) ( ) PH 5.70 (00.0) SF00PH5X (I-, J-, K-Frame) ( ) PH, PH (00.0) SF00PH0X0 00 (L-Frame) ( ) PH, PH (00.0) SF00PH0X0 00 (M-Frame) ( ) PH, PH (00.0) SF00PH0X A (I-, J-, K-Frame) ( ) PH, PH3.60 (30.0) SF30PH0X0 00 (L-Frame) ( ) PH, PH3.60 (30.0) SF30PH0X0 00 (M-Frame) ( ) PH, PH3.60 (30.0) SF30PH0X (I-, J-, K-Frame) ( ) PH, PH (00.0) SF00PH0X0 00 (L-Frame) ( ) PH, PH (00.0) SF00PH0X0 00 (M-Frame) ( ) PH, PH (00.0) SF00PH0X (I-, J-, K-Frame) ( ) PH, PH (500.0) SF500PH0X0 00 (L-Frame) ( ) PH, PH (500.0) SF500PH0X0 00 (M-Frame) ( ) PH, PH (500.0) SF500PH0X (N-Frame) ( ) PH3.60 (30.0) SF30PHX (N-Frame) (70.0.0) PH3.60 (30.0) SF30PHX (N-Frame) ( ) PH (00.0) SF00PHX (N-Frame) ( ) PH (50.00) SF500PHX V5-T-3 Volume 5 Motor Control and Protection CA000006E December 03
35 R9 Series (UL 9).3 Terminal Shrouds Auxiliary Contacts NO + NC Description For the R9 Series Fusible 30 00A, indication of the O and I positions by to NO + NC auxiliary contacts. Electrical principle: Cabling by terminal cage with #6 AWG maximum. High electrical characteristics: A600/D600 Auxiliary Contacts NO or NC 3 Description Ampere Rating (Frame) Number of ACs Catalog Number The different functions (pre-break, 0 and indication, NO Auxiliary Contact TEST feature) are easily configurable with pegs (one or two pegs per position). Two superposed (H M-Frame) ACNOR9 auxiliary contacts maximum. NC Auxiliary Contact For 30A/CC (H-Frame), maximum of four ACs. For 30A/J (H-Frame), maximum of two ACs (H M-Frame) ACNCR9 For 30 to 00A/J (I, J and K-Frame), maximum of four ACs. For 00 to 600A/J (L and M-Frame), maximum of eight ACs. Cabling to the control circuit by terminals with a maximum section of x.5 mm. Electrical characteristics: A300 Terminal Shrouds Notes Ampere Rating (Frame) Number of ACs Same-make/same-break auxiliary contacts. Auxiliary contacts without Test cannot be used on I M-Frame switches. 3 Early-break/same-make auxiliary contacts. For replacement only. Both line and load side terminal shrouds are included with 00A switch. Operating Current I e (Amperes) Nominal Current (Amperes) Catalog Number (N-Frame) NO + NC 0 ACNONCJN (N-Frame) NO + NC 0 ACNONCJN (I M-Frame) NO + NC (w/ TEST) 0 ACNONCJNT (I M-Frame) NO + NC (w/ TEST) 0 ACNONCJNT Characteristics for Pre-Break Auxiliary Contacts Operating Current I e (Amperes) Nominal Current Ampere Rating Contact Type Amperes 50 Vac AC-3 00 Vac AC-3 Vdc DC-3 Vdc DC NO + NC Description Ampere Rating (Frame) Number of Poles Catalog Number Line or load side protection against direct contact (H-, I-, J-, K-Frame) /3/ Integral to switch with terminals or the connection parts 00 (L-Frame) TSR9L 00 (L-Frame) 3 TSR9L3 00 (L-Frame) TSR9L3 00 (M-Frame) TSR9M 00 (M-Frame) 3 TSR9M3 00 (M-Frame) TSR9M (N-Frame) TSR9N (N-Frame) 3 TSR9N (N-Frame) TSR9N Volume 5 Motor Control and Protection CA000006E December 03 V5-T-35
36 .3 R9 Series (UL 9) Line and Load Terminal Lugs Description Ampere Rating (Frame) Fuse Connection of bare copper cables on to the terminals (no spade lugs). Number of Lugs Lug Capacity/ Phase Cable Type Catalog Number 30 (H-, I-Frame) CC/J # #0 Cu Integral to switch 30 (H-, I-Frame) CC/J # #0 Cu Integral to switch (J-Frame) J #0 #6 Cu Integral to switch (K-Frame) J # # Cu Integral to switch 00 (L-Frame) J #6 300 kcmil Cu/Al LKR9DL 00 (L-Frame) J 3 #6 300 kcmil Cu/Al LK3R9DL 00 (L-Frame) J #6 300 kcmil Cu/Al LKR9DL 00 (M-Frame) J 3 () # 600 kcmil Cu/Al LK3R9FN 00 (M-Frame) J () # 600 kcmil Cu/Al LKR9FN (N-Frame) J/L () # 600 kcmil Cu/Al LKR9FN (N-Frame) J/L 3 () # 600 kcmil Cu/Al LK3R9FN (N-Frame) J/L () # 600 kcmil Cu/Al LKR9FN Shorting Links Ampere Rating (Frame) Fuse Pack Quantity Catalog Number 60 (J-,K-Frame) J 3 SLJK (K-Frame) J 3 SLK (L-Frame) J 3 SLL3 00 (M-Frame) J 3 SLM (N-Frame) J/L 3 SLN3 V5-T-36 Volume 5 Motor Control and Protection CA000006E December 03
37 R9 Series (UL 9).3 Technical Data and Specifications UL and CSA Characteristics R9 Series Fusible 30 00A Description 30A 30A 30A 30A 60A 60A 00A General Use Ratings Switch frame H H I J J K K 600 Vac (A) Vdc (A) Short-Circuit Ratings Short-circuit rating at Vac (ka) Fuse type CC J CC J J J J Maximum fuse rating (A) Maximum Horsepower Rating/Maximum Motor FLA Three-Phase 0 0 Vac 7.5/ 7.5/ 7.5/ 7.5/ 5/ 5/ 30/0 0 0 Vac 5/ 5/ 5/ 5/ 30/0 30/0 60/ Vac 0/ 0/ 0/ 0/ 50/5 50/5 75/77 Maximum Horsepower Rating/Maximum Motor FLA Single-Phase 0 0 Vac 3/7 3/7 0/50 0/50 0/ Vac 7.5/ 7.5/ 0/6 0/6 0/6 600 Vac 0/0 0/0 0/0 0/0 0/0 Maximum Horsepower Rating/Maximum Motor FLA DC 5 Vdc 3/5 3/5 3/5 3/5 5/0 5/0 7.5/5 50 Vdc 5/0 5/0 5/0 5/0 0/3 0/3 0/7 Mechanical Characteristics Endurance 0,000 0,000 0,000 0,000 0,000 0,000 0,000 (number of operating cycles) Terminal Lugs Type Integrated Integrated Integrated Integrated Integrated Integrated Integrated Minimum conn. section # # # #0 #0 # # Maximum conn. section #0 #0 #0 #6 #6 # # Notes Two-pole in series. Three-pole in series. Volume 5 Motor Control and Protection CA000006E December 03 V5-T-37
38 .3 R9 Series (UL 9) R9 Series Fusible 30 00A, continued Description 00A 00A 600A 00A General Use Ratings Switch Frame L M N N 600 Vac (A) Vdc (A) Short-Circuit Ratings Short-circuit rating at 600 Vac (ka) Fuse type J J J L Maximum fuse rating (A) Maximum Horsepower Rating/Maximum Motor FLA Single-Phase 0 0 Vac 0 0 Vac 600 Vac Maximum Horsepower Rating/Maximum Motor FLA Three-Phase 0 0 Vac 60/5 5/3 00/0 00/0 0 0 Vac 5/56 50/30 500/ / Vac 50/ 350/ /7 500/7 Maximum Horsepower Rating/Maximum Motor FLA DC 5 Vdc 0/ 50 Vdc 50/73 Mechanical Characteristics Endurance (number of operating cycles) Terminal Lugs Type Option Option Option Option Minimum conn. section #6 # x# x# Maximum conn. section 3/0 300 kcmil x 600 kcmil x 600 kcmil Notes Two-pole in series. Three-pole in series. V5-T-3 Volume 5 Motor Control and Protection CA000006E December 03
39 R9 Series (UL 9).3 Dimensions Approximate Dimensions in Inches (mm) Front Operation R9 Series Fusible 30A/CC H-Frame H R9 Series Fusible 30A/J H-Frame H Z Switch Body Switch Mounting Connection Terminals F H H J J N N AA Z 3.7 (96.0) 3. (3.3) 5.9 (3.).7 (37.3) 0.59 (5.0) 3.3 (79.5).00 (5.).56 (5.). (.) H Z Switch Body Switch Mounting Connection Terminals F H J J N N AA Z.3 (0.9) 3.9 (9.).7 (37.3) 0.59 (5.0) 3.30 (3.).00 (5.).56 (5.). (.) AA AA N N F F J J J N J N Volume 5 Motor Control and Protection CA000006E December 03 V5-T-39
40 .3 R9 Series (UL 9) Approximate Dimensions in Inches (mm) R9 Series Fusible 30A/CC I-Frame H 6.0 (53.0) R9 Series Fusible 30A/J and 60A/J (00 ka) J-Frame Z AA 0. (0.3).9 (6.5) Switch Body Switch Mounting Connection Terminals Ampere Rating (Fuse) F 3P F P H J M N N AA Z 30 (CC).9 (5.0) 6.06 (5.0) 3.9 (99.0).77 (5.0). (9.0) 5.3 (35.0).63 (66.5) 5.7 (9.0). (3.0) 5.35 (35.9).0 (0.) 5.7 (9.). (35.).6 (37.). (35.). (9.0). (.9) M F J N N V5-T-0 Volume 5 Motor Control and Protection CA000006E December 03
41 R9 Series (UL 9).3 Approximate Dimensions in Inches (mm) R9 Series Fusible 60A/J (00 ka) and 00A/J K-Frame 7.3 (5.9) 6.77 (7.0) R9 Series Fusible 00A/J L-Frame 5. (9.) 5.3 (3.). (35.). (35.) 5.7 (9.) 7.7 (96.).96 (9.).6 (37.) 6. (57.0) 6.6 (67.9). (35.) 5. (3.). (.) 6.50 (65.) 7.67 (9.).6 (9.) Volume 5 Motor Control and Protection CA000006E December 03 V5-T-
42 .3 R9 Series (UL 9) Approximate Dimensions in Inches (mm) R9 Series Fusible 00A/J M-Frame H R9 Series Fusible A J/L N-Frame H Z AA 0.0 (0.) 5.00 (7.0). (30.0) M F M J M0 N 6.53 (66.0) Switch Body Switch Mounting Connection Terminals F 3P F P H H J M N N AA Z 0.0 (76.0) 3.70 (3.0) 5.56 (.5). (90.0) 0. (.5). (7.0).3 (.0). (.0).3 (363.5).06 (7.0) Min. 0.3 (Min. 6.9) 9. (9.9) 6.0 (5.9) 0.7 (6.9).3 (5.9).96 (30.0) 3. (79.). (300.0) 0.7 (6.9) 3.5 (9.9) 0.7 (6.9) 3.36 (5.3) 0.3 (0.9) Fix 9. (Fix 50.0) (300.0) 0.3 (7.0) (59.) 3.36 (5.3) ø0.5 (ø3.0).00 (50.) 3P. (.0).56 (65.0) 3.70 (9.0) 3P.33 (36.0) P. (37.0) 3.70 (9.0) P.03 (5.0).3 (3.0) 0.35 (.9) 9.7 (35.5) 0.6 (.) 9.7 (35.5) N V5-T- Volume 5 Motor Control and Protection CA000006E December 03
43 R9 Series (UL 9).3 Approximate Dimensions in Inches (mm) 30CC (H-Frame). (.0) 30J (H-Frame) 5. (30.0).3 (5.7) 30J to 00J.36 (60.0) 600J and 00L.57 (0.0).79 (5.5) 7. (90.0) 5.3 (35.0) 3.35 (5.0) Flange Handle 6. (5.0) 3.50 (.9).6 (5.9) 0.6 (.).06 (6.9) 5.66 (3.) Ø0.50 (Ø.7).00 (5.) Ø0. (Ø7.).55 (39.) (5.) (.3).6 (.9) 7.0 (0.3).3 (5.9).70 (6.6) Volume 5 Motor Control and Protection CA000006E December 03 V5-T-3
44 .3 R9 Series (UL 9) Approximate Dimensions in Inches (mm) Door Interlocked External Handle PH Type Handle PH Type Handle PH3 Type Handle Direction of Operation I Door Drilling Template.57 (0.0) Ø.6 (37.0).73 (.0) Ø3.07 (Ø7.0) Ø3.07 (Ø7.0).75 (70.0) Line and Load Side Lugs 00A (L-Frame).5 (3.6) 90º 0º Ø7.0 (.0) 0.5 (Ø.).00 (5.). (.) I.57 (0.0) Ø.6 (37.0) 90º 0º.9 (5.0).77 (5.0) 00 00A (M- and N-Frames) 3.5 (0.0) Ø7.0 (.0).9 (37.) 0.0 (Ø0.).7 (7.9) Ø3.07 (Ø7.0) I.57 (0.0) Ø.6 (37.0) 90º 0º Ø7.0 (.0).7 (0.0).0 (6.0) V5-T- Volume 5 Motor Control and Protection CA000006E December 03
45 R9 Series (UL 9).3 DC Rated Disconnects Contents Description Non-Fusible 30 00A Compact Non-Fusible 00 00A Fusible 30 00A DC Rated Disconnects Product Selection Accessories Technical Data and Specifications Dimensions Page V5-T- V5-T- V5-T-6 V5-T-6 V5-T-7 V5-T-9 V5-T-50 DC Rated Disconnects Product Description UL listed disconnect switches 600 Vdc for photovoltaic applications 00 to 00A R9 Series (UL 9 listed) DC rated disconnects are manually operated multi-pole load break switches. They provide safety isolation for any low voltage circuit in a photovoltaic application. Application Description In three- and four-pole versions from 00 to 00A Standards and Certifications UL 9, culus, File E59 CSA. No., File 7736 IEC EN IEC (Rules for the installations and sites special photovoltaic applications) Features, Benefits and Functions Switching technology Up to 600 Vdc according to UL 9 / CSA Up to 000 Vdc according to IEC 97-3 Note Q 00 Simplified Large Photovoltaic System Layout Source Combiner R9 DC R9 DC Array Combiner R9 DC A up to 000V Array Combiner R9 DC 00 00A up to 000V R9 DC 00 to 00A to 000V Standard R9 Series AC disconnect switch non-fusible up to 00A or fusible up to 00A Volume 5 Motor Control and Protection CA000006E December 03 V5-T-5
46 .3 R9 Series (UL 9) Product Selection Direct Operation External Operation Front Operation Three- and Four-Pole Ampere Rating Number of Poles Switch Body Direct Handle External Handle (Choose one) R9D300UDC R9D00UDC R9D300UDC R9D00UDC DHR9DE S Type Black, 3R, PHBNF Red/Yellow, 3R, PHRNF Black, X PHBNXF Shaft for External Handle In (mm) (Choose one) 7.90 (00.0) SF00PH0X0.60 (30.0) SF30PH0X (00.0) SF00PH0X0 Auxiliary Contacts (Choose one) C Type st Contact NO+NC ACNONCDE C Type nd Contact NO+NC ACNONCDE Terminals Shroud 3P TS3R9DT 3P 3 TS3R9DB P TSR9DTB 00 3 R9E300UDC R9E00UDC Red/Yellow, X PHRNXF 3P TS3R9ET 3P 3 TS3R9EB Terminal Lugs 3P LK3R9DL P LKR9DL 3P LK3R9EM P LKR9EM Jumpers for Connecting Poles in Series pieces DCJUMPD 3 pieces DCJUMPD3 pieces DCJUMPE 3 pieces DCJUMPE3 P TSR9ETB Notes Defeatable handle. Top (line side). 3 Bottom (load side). Top or bottom (line or load side). V5-T-6 Volume 5 Motor Control and Protection CA000006E December 03
47 R9 Series (UL 9).3 Accessories Direct Handle PH Type Handle Direct Handle Description Ampere Rating Handle Color Catalog Number Front operation Black DHR9DE Door Interlocked External Handle Front Operation l 0, Three- and Four-Pole Ampere Rating Handle Handle Color NEMA Type Catalog Number PH Type Black, 3R, PHBNF PH Type Red/yellow, 3R, PHRNF PH Type Black, X PHBNXF PH Type Red/yellow, X PHRNXF Auxiliary Contacts Description Ampere Rating Number of AC Type Catalog Number Early-break/same-make and signaling of positions 0 and : to NO/NC auxiliary contacts to low level NO/NC auxiliary contacts Characteristics: NO/NC AC: IP with front and side operation Connection to the control circuit: By 6.35 mm fast-on terminal Electrical characteristics: 30,000 operations; A300 Terminal Screens Description Ampere Rating Number of Poles Position Catalog Number Line or load side protection against Three- and Four-Pole direct contact with terminals or connection parts Top (line) TS3R9DT Bottom (load) TS3R9DB Top or bottom (line or load) TSR9DTB 00 3 Top (line) TS3R9ET 00 3 Bottom (load) TS3R9EB 00 Top or bottom (line or load) TSR9ETB Note Order two sets for line and load sides. NO/NC Contact for Three and Four Poles AC NO + NC C Type AC C Type NO + NC Low Level NO/NC Contact for Three and Four Poles AC C Type NO + NC AC C Type NO + NC ACNONCDE ACNONCDE ACNONCDELL ACNONCDELL Volume 5 Motor Control and Protection CA000006E December 03 V5-T-7
48 .3 R9 Series (UL 9) Line and Load Terminal Lugs Line and Load Terminal Lugs Description Ampere Rating Connection Type Connection of bare copper cables onto the terminals Jumpers for Connecting Poles in Series Description Ampere Rating Kit of Figure Number of Poles in Series Catalog Number The jumpers will make easy pieces 3 DCJUMPD the connection of the poles in series, allowing the following 3 pieces DCJUMPD3 configurations: 00 pieces 3 DCJUMPE 00 3 pieces DCJUMPE3 - + Load - Load X + Shaft Extensions for External Front Dimensions (X) Inches (mm) Ampere Description Rating Dimension X Handle Shaft Length Catalog Number Standard lengths: 7.9 inches/00 mm.6 inches/30 mm 5.7 inches/00 mm Note For other connections, refer to installation instructions. Number of Cables per Terminal Lugs per Kit Cable Type Catalog Number kcmil Cu/Al LKR9DL kcmil Cu/Al LKR9DL kcmil Cu/Al LKR9EM kcmil Cu/Al LKR9EM For Three- and Four-Pole ( ) PH Type 7.90 (00.0) SF00PH0X ( ) PH Type.60 (30.0) SF30PH0X (39.0.0) PH Type 5.70 (00.0) SF00PH0X0 V5-T- Volume 5 Motor Control and Protection CA000006E December 03
49 R9 Series (UL 9).3 Technical Data and Specifications 00 00A Characteristics According to UL 9 Characteristics According to IEC Ampere Rating Thermal Current I th at 0 C (A) General Use Purpose Ampere Rating Rated voltage In series A A A 600 Vdc 3P Overload Capacity Prospective short-circuit current (ka rms) Type of fuse A70P00 A70P00 LDC Fuse rating Connection Terminals Minimum connection section/awg #6 #6 # Maximum connection section/awg 300 kcmil 300 kcmil 600 kcmil Auxiliary Contacts Electrical characteristics A300 A300 A300 Ampere Rating Thermal Current I th at 0 C (A) Rated Operational Currents I e (A), DC- B Rated voltage In series A A A 750 Vdc 3P Vdc P 000 Vdc P Volume 5 Motor Control and Protection CA000006E December 03 V5-T-9
50 .3 R9 Series (UL 9) Dimensions Approximate Dimensions in Inches (mm) R9 Series DC Rated Disconnects 00 00A Front Operation V K CA J R9 Series DC Rated Disconnects T M F U W R N R AA AC H Ampere Rating C AC AD F 3P F P H J 3P J P K M 3P M P (9.5) 0.0 (56.5) 3.05 (77.5) 7.09 (0.) 9.06 (30.0). (07.).7 (55.).3 (0.9).0 (5.7) 6.30 (60.0).7 (0.) 00.9 (5.0) 6.00 (06.).5 (.5) 9.05 (30.0).0 (90.0) 6.53 (66.0).95 (75.7) 5.3 (3.9).65 (67.3).6 (09.) 0.60 (69.) Z Y AD C The switch will operate correctly when rotated clockwise 90 degrees. The switch will not operate correctly when rotated counterclockwise 90 degrees. Ampere Rating N R R T U V W Y Z AA CA (35.0) 0.35 (.9) 0.7 (6.9).97 (50.0) 0.9 (.9). (30.0) 0.3 (0.9) 0. (3.6).35 (3.3) 6.30 (60.0) 0.60 (5.) (93.0) 0.35 (.9) 0.7 (6.9).56 (65.0).77 (5.0).97 (50.0) 0.3 (0.9) 0.0 (5.).0 (5.) 0.0 (59.) 0.0 (0.3) V5-T-50 Volume 5 Motor Control and Protection CA000006E December 03
51 R9 Series (UL 9).3 Approximate Dimensions in Inches (mm) Jumpers 00 00A 00A 0.9 (.5) 0.59 (5.0) Terminal Lugs 00 00A 00A.5 (3.6) Door Interlocked External Handle 00 to 00A, Three- and Four-Pole PH Type Handle Direction of Operation I 0.7 (.0) 0.5 (Ø.) Ø0.3 (Ø.0).00 (5.). (.) Ø3.07 (Ø7.0) 90º 0º.97 (50.0).9 (5.0).77 (5.0) 0.9 (.5) 0.6 (.0) Door Drilling Template.57 (0.0) Ø.6 (37.0) Ø7.0 (.0) 9.00 (.6).30 (35.0).0 (6.0).00 (057.).50 (57.5).0 (7.5) (65.0) 0.63 (5.9) 0. (.3) Ø 0.0 (Ø0.6) Ø.70 (Ø9.3).50 (57.5) 5.00 (7.0) Volume 5 Motor Control and Protection CA000006E December 03 V5-T-5
52 . Manual Transfer/Double Throw Switches Manual Transfer Switches Contents Description Manual Transfer/Double Throw Switches Product Selection Accessories Technical Data and Specifications Dimensions Page V5-T-53 V5-T-5 V5-T-56 V5-T-57 Product Description R9 Series (UL 9 listed) non-fusible disconnects are heavy-duty manual transfer switches, they transfer load manually between two low voltage circuits and provide safety disconnection. These switches are extremely durable and are tested and approved for use in the most demanding applications as resistive load or total system applications. Three load break positions (I, 0, II) On load switching Direct or external handle 0 Vac total system 600 Vac resistive load Standards and Certifications UL 9, culus, File E59 UL00 (600 00A) CSA. No., File 7736 IEC EN CE 5 Product Identification External front handle Direct handle 3 Shaft extension for external handle Pre-break ACs (standard on A) 5 Terminal screen 3 V5-T-5 Volume 5 Motor Control and Protection CA000006E December 03
53 Manual Transfer/Double Throw Switches. Product Selection Direct Operation Manual Transfer/Double Throw Switches UL 9 Standard Ampere Rating Number of Poles Switch Body Only Direct Handle (Black) External Three- Position Handle (Choose one) RMTS300U RMTS00U RMTS300U RMTS00U DHMTSSL Size, Black I 0 II Type /X PHBNX3P Size, Red I 0 II Type /X PHRNX3P 00 3 RMTS300U Size 3, Black RMTS00U I 0 II Type /X PHB3NX3P Size 3, Red I 0 II Type /X PHR3NX3P RMTS3600U DHMTSDL Size, Black RMTS600U I 0 II Type /X PHBNX3P Notes All ratings, 00 00A, are UL 9 listed. Switches rated A are UL 00 listed as well. Line or load (top or bottom); for both line and load, order two kits. 3 Low level auxiliary contact gold plated for minimal resistance for PLC applications. Shaft Extensions for External Handle In (mm) (Choose one) 7.90 (00.6) SF00PH0X0.60 (30.0) SF30PH0X (39.) SF00PH0X (00.6) SF00PH5X.60 (30.0) SF30PH5X 5.70 (39.) SF00PH5X Bridging Bars 3P BB3P00 P BBP00 3P BB3P00 P BBP00 3P BB3P600 P BBP600 Size, Red 00 3 RMTS300U DHMTSDLM I 0 II 3P Type /X BB3P00 RMTS00U PHRNX3P 00 3 RMTS300U RMTS00U External Operation Switch body + Direct handle Switch body + Shaft + External handle P BBP00 Auxiliary Contacts NO/NC ACNONCMTS00 Low level ACNONCMTS00LL 3 NO/NC contact standard Terminal Screens 3P TS3MTS00TB P TSMTS00TB 3P TS3MTS00TB P TSMTS00TB 3P TS3MTS600 P TSMTS600 3P TS3MTS00 P TSMTS00 Volume 5 Motor Control and Protection CA000006E December 03 V5-T-53
Catalog Number A, up to two ACs max (F-, G-Frame) Number of Poles. Rating (Frame) (D-Frame) 400 (E-Frame)
.0 R9 Series (UL 98) Non-Fusible 00 00A Auxiliary Contacts Terminal Screens Line and Load Terminal Lugs Maximum Ampere Rating (Frame) Notes Early-break/same-make. Gold plated for minimal resistance for
More informationR9 Series Non-Fusible A Compact Page 47 Page 49 Page 51. R9 Series. Page 53 Page 58 Page 59 IEC EN
Circuit Protection.3 Open Rotary Disconnects Product Overview Rotary Disconnect Switch Selection Guide Description Product Description Approvals Description Product Description Approvals Note Q4 2010 R5
More informationContents. Volume 5 Motor Control and Protection CA E December
Rotary Disconnects.4 Contents Description Page Product Description............................. 677 Standards and Certifications...................... 677 Product Selection..............................
More informationFUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A
Fuse protection The solution for > Motor on-load disconnect > Protection of industrial cabinet > Electrical distribution ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches
More informationFUSERBLOC UL Fusible disconnect switches UL and CSA 30 to 800 A
Fuse protection The solution for > Motor load break. > Protection of industrial cabinet. > Electrical distribution. ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches
More informationIDE Load break switches for machine control Remotely trippable switch from 32 to 160 A
The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct
More information63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.
comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power
More informationNon-Fusible Disconnect Switches
UL 98 and IEC, Non-Fused Switches Mersen s non-fusible disconnect switches are listed to UL 98 and bear the CE mark as conformance to IEC 60947-3. They are service entrance devices that are capable of
More informationSIRCO Load break switches for power distribution from 125 to 5000 A
The solution for Load break switches sirco_456_a_1_cat > Main switchboard > Distribution panel > Emergency breaking > Network coupling > Local safety breaking sirco-ac_001_a_1_cat SIRCO 3 x 250 A direct
More informationNon-Fusible Disconnect Switches
UL 98 and IEC, Non-Fused Switches Mersen s non-fusible disconnect switches are listed to UL 98 and bear the CE mark as conformance to IEC 60947-3. They are service entrance devices that are capable of
More informationSOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES
MANALL OPERATED CHANGEOER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application:
More informationComplete UL/CSA Disconnect Switch Kits
Product Selection Complete UL/CSA Disconnect Switch Kits Includes disconnect switch, operating handle with defeater mechanism and operating shaft, NFPA handle, auxiliary contacts, and padlock attachment.
More information194E FA 32 E P11 P11 6
Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable for padlocks) E-FA Painted Steel Enclosure
More informationDisconnect Switches. Safe Switching and Disconnecting
IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as
More information1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors
. Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................
More informationMiniature Circuit Breakers and Supplementary Protectors. Contents
. Optimum and Efficient Protection for Every Application Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant.
More informationUL 98 Fusible Disconnect Switches
UL 98 Fusible Mersen s fusible disconnect switches are listed to UL 98 and bear the CE mark as conformance to IEC 60947-3. They are service entrance devices capable of fully rated load-break and load-make.
More informationSwitch Disconnectors, Main and EMERGENCY-STOP Switches
General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)
More informationUL 489 Cable-In / Cable-Out Branch Circuit Breaker
Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up
More information1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers
.2 WMZ Circuit Breakers Contents Description WMZ Circuit Breaker Standards and Certifications.............. Selection................ Product Selection....................... Accessories...........................
More informationThe safest way to switch power on and off in your industrial control panels.
The safest way to switch power on and off in your industrial control panels. Your problem: You need a range of disconnect switches for your industrial control requirements ranging from Service Entrance
More information60103 Circuit Breaker
6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard
More informationFUSERBLOC from 30 to 800 A
from 30 to 800 Product presentation FB30DT FB30SO Ferraz Shawmut FUSERBLO disconnect switches are extremely durable, manually operated, fusible disconnect switches. The switches employ double break contacts
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More information1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control
. Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT
More informationBulletin 194R Fused and Non-Fused Disconnects Product Selection
Product Selection 4th Pole Modules Maximum Hp Ratings Rated 1-Phase (60 Hz) -Phase (60 Hz) DC Current [A] 1V 240V 240V 480V V 12V V Ref. Non-d 0 2 7. 1 A2 194R-0-NN 60 1 0 40 B2 194R-60-NN UL Class CC
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More information194E FA 32 E P11 P11 6
Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable f padlocks) E-FA Painted Steel Enclosure
More informationBulletin 194R Fused and Non-Fused Disconnects Product Selection
Product Selection 4th Pole Modules Maximum Hp Ratings Rated 1-Phase (60 Hz) -Phase (60 Hz) DC Current [A] 10V 40V 40V 480V V 1V 0V Ref. Cat. No. Non-d 0 7. 1 0 A 194R-0-NN 60 1 0 40 B 194R-60-NN UL Class
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More informationClose Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors
Close Protection from Moeller miniature branch circuit breakers miniature supplementary protectors FAZ branch circuit breakers General Information... Selection Tables Trip Characteristic C - Box terminals...
More information1492-SP Supplementary Protectors
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationSECTION DISCONNECT SWITCHES
SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification
More informationFUSERBLOC LMDC Fuse combination switches FUSERBLOC Live Maintenance DC
Fuse protection The solution for > Live maintenance of speed drives supplied by a common DC bus > Live maintenance of PV inverters connected in parallel on a same circuit fuser-lm_2_a Strong points > Compact
More informationReferences. For SIRCO MV. References
16 to 160 A Functions Dimensions sircm_071_b_1_x_cat Direct handle M00 handle sircm_041_a_1_x_cat M01 handle Handle colour Handle 16 80 100 125 Blue Blue M00-type M01-type 2299 5012 2299 5032 Handle colour
More information3RV1 Circuit-Breakers
SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a
More informationProduct Guide. UL 1077 DIN Rail Supplementary Protectors
Product Guide UL 0 DIN Rail Supplementary Protectors UL 0 DIN Rail Supplementary Protectors Product Overview... Product Selection WMZS B Curve ( X I n Current Rating)..............................................
More informationProduct Guide. UL 489 DIN rail miniature circuit breakers
Product Guide UL 489 DIN rail miniature circuit breakers UL 489 DIN rail miniature circuit breakers Product Overview................................................ 2 Product Selection WMZT 10 kaic at
More informationJ7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1
Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload
More informationMOTOR PROTECTION CIRCUIT BREAKERS
MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm
More informationMotor protection circuit breakers
Wide adjustment range 0. to 00A IEC breaking capacity Icu 50kA (400V) up to 00A Suitable for isolation Comprehensive line of accessories Magnetic-only version Automatic trip indicators High reliability
More informationProtection Equipment
Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data
More informationSwitch rated plugs and receptacles with NEMA 4X protection
DSN Features and Ratings p. 22 DSN20 p. 23 DSN30 p. 25 DSN60 p. 27 Spare parts p. 29 Dimensions p. 31 21 Switch rated plugs and receptacles with NEMA 4X protection DSN Series products are switch and hp
More informationManual Motor Control Switches and Disconnects
Manual Motor Control Switches and Disconnects Vario, GS1, GS2, and LK4 9421CT0301R09/12 2013 CONTENTS Description............................................. Page Mini-VARIO and VARIO Manual Motor Control
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationSwitch-disconnectors OTDC and OTDCP Switches for photovoltaic applications
Protection and Connection Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications DC switch-disconnectors
More informationApproved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.
Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit
More informationOVERLOAD RELAYS POWER & ACTUATION PROVEN. series
POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be
More informationReferences. For front operation. For right side operation. Padlockable in position 0. Handle type. Frame size. Padlockable in position 0 and I
DIRECT OPERATION T O O R D E R EXTERNAL OPERATION Fuse combination switches picto_080_c_1_gb_cat Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle Direct handle acces_147_a_2_cat
More informationPowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)
PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 0CT00R/0 0 CONTENTS Description..............................................Page Description.............................................
More informationMotor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)
More informationthe Santon FCS-type switch Disconnect Superior Switch Solutions
the Santon FCS-type switch Disconnect Superior Switch Solutions The technical information given in this table applies to 3 and 4 pole fuse combination switches. FRAME SIZE 1 1 2 3 3 4 4a 4b 5 6 6 nominal
More informationMini Contactors & Overloads
108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)
More informationUL 489 DIN rail branch circuit breakers
UL 9 DI rail branch circuit breakers FAZ-A circuit breakers Product Overview UL 9 DI rail branch circuit breakers FAZ-A circuit breakers PRODUCT OVERVIEW Optimum and efficient protection Optimum product
More informationMG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD
United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL
More informationCS8 Industrial Control Relays
CS8 Industrial Control Relays Despite increasing complexity, control systems and installations must become increasingly compact. And the CS8 Miniature Relay System packs maximum performance into minimum
More informationWMS SUPPLEMENTARY PROTECTORS
WMS Supplementary Protectors Overview WMS SUPPLEMENTARY PROTECTORS Product Specification The WMS Supplementary Protector is a dual-rated product for both AC and DC supplies, in accordance with UL 1077
More informationMULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors
B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors
More informationSiemens AG 2017 SENTRON. 3LD Main Control and EMERGENCY-STOP Switches. Catalog Extract LV 10. Edition 10/2017. siemens.com/switching-devices
Siemens AG 201 SENTRON 3LD Main Control and EMERGENCY-STOP Switches Catalog Extract LV 10 Edition 10/201 siemens.com/switching-devices Siemens AG 201 Related catalogs Low-Voltage Power Distribution and
More informationCircuit Breakers Type CTI 25M, CTI 45MB
Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is
More informationAThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.
www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More informationlow voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters
CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor
More informationReferences. References. Rating (A) Référence
DIRECT OPERATION T O O R D E R EXTERNAL OPERATION picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle acces_128_a_1_cat acces_129_a_1_cat Direct handle
More informationCircuit Breakers, Type CTI 25M, CTI 45MB, CTI 100
MAKING MODERN LIVING POSSIBLE Data sheet Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit and overload protection of motor applications cover together with the circuit
More informationSafety Products Introduction LS-Titan Safety Interlock Switches. Technical Reference... 2
Key Interlock Switch Door-Flap Switch Door-Hinge Switch.0 Introduction Technical Reference............................................ 2.1 Learn Online Product Description.............................................
More informationSiemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.
KD Switch Disconnectors SENTRON Edition December 01 Answers for infrastructure and cities. Related catalogs Low-Voltage Power Distribution and LV 10 Electrical Installation Technology SENTRON SIVACON ALPHA
More informationMOTOR & CIRCUIT PROTECTION
2 MOTOR & CIRCUIT PROTECTION Motor Protection Circuit Breakers p2-1 Motor Protection Relays p2-13 Thermistor Protection Relay p2-18 Fuse Holders p2-20 Miniature Circuit Breakers p2-23 Residual Current
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60
DATASHEET - FAZ-C5/2-RT Miniature circuit breaker (MCB), 5A, 2p, C-Char, AC Part no. FAZ-C5/2-RT Catalog No. 102203 Eaton Catalog No. FAZ-C5/2-RT EL-Nummer 1691799 (Norway) Similar to illustration Delivery
More informationNF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC1010D0201 28/03/11 NFE-.. / NFZE-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)
More information3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017
3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka
DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery
More informationSelection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationIntroduction Circuit Protection
Introduction Circuit Protection Weidmuller s DIN-rail mounted circuit breakers are available for use in applications where circuit protection must be able to distinguish between circuit overloads and short
More informationJockey Pump Controllers
BR081001EN Microprocessor Based with Color Touchscreen Product Description ACROSS THE LINE Controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single
More informationSwitches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors
6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or
More informationK1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm
Characteristics cam voltmeter switch - 3L and 3L-N - 60-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationAllen-Bradley Bulletin 100 Contactors
Allen-Bradley Bulletin 100 Contactors An integrated portfolio of IEC Contactors that save panel-space and energy Features and Benefits: Direct-on-line and reversing contactors Built-in surge suppression
More informationMagnetically Actuated Safety Interlock Switches
Conforms to EN10, EN292, EN020-1 CSA and BG approved Actual Size Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic,
More information5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009
Siemens AG 9 BETA Protecting SR Busbar Systems /2 Product overview /3 Distribution board components /9 Built-in components /17 Mounting components Siemens ET B1 10/9 BETA Protecting SR Busbar Systems Siemens
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG GERMANY This is to certify that representative samples of Motor Controllers, Magnetic (See following pages for additional
More informationAllen-Bradley 1492-RCDA4A40
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Suitable for DIN Rail mounting Approval marks are easily visible on dome Terminal design helps
More informationK1K015NZ4 cam stepping switch - 2-pole A - screw mounting
Characteristics cam stepping switch - 2-pole - 60-12 A - screw mounting Complementary Number of steps 5 Main Range of product Product or component type Component name [Ith] conventional free air thermal
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker
Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics ensures suitability for a wide range of applications.
More informationApproved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.
Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit
More informationMagnetically Actuated Safety Interlock Switches
Rev. 7.07 C US Conforms to EN1088, EN292, EN6020-1 CSA approved MA Series Magnetically Actuated Safety Interlock es Large selection choose from a large selection of contact configurations housed in plastic
More informationK1D004ACH cam switch - 4-pole A - for Ø 22 mm
Characteristics cam switch - 4-pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing mode Cam
More informationSelection Guide. Control Circuit and Load Protection
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationDISCONNECT SWITCHES > QUICK REFERENCE GUIDE north american edition
DISCONNECT SWITCHES > QUICK REFERENCE GUIDE north american edition OUR COMMITMENT MAKES THE DIFFERENCE > GUARANTEE, CONFORMITY OF LONG-LASTING PRODUCTS BACO facilitates the daily work offering ingenious
More informationSiemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.
3RA Fuseless Compact Starters Catalog News LV 1 N April 2008 SIRIUS www.siemens.com/lowvoltage 3RA Fuseless Compact Starters General data Overview 3RA fuseless compact starters and infeed system for 3RA
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
Delivery program Contactor relay, 3N/O+1N/C, DC current Part no. DILA-31(24VDC) Catalog No. 276379 Eaton Catalog No. XTRE10B31TD EL-Nummer 4130206 (Norway) Product range DILA relays Application Contactor
More informationMini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors
More information1510 MOTOR CONTROLLERS
SECTION 262913- MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of contract, including general and supplementary conditions and Division 1 specification section,
More informationIndustrial Controls Product Catalog RA64 / 3RA65 up to 32 A for mounting rail, surface,
Combination Starters Industrial Controls Product Catalog 2017 Section c o n t e n t s Self Protected Motor Starters per UL 508 Type E 3RA6 3RA61 / 3RA62 up to 32 A for mounting rail, surface, comb busbar,
More informationSection 4 Ground-Fault Protection Devices
Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that
More information