EXPEDITED PERMIT PROCESS FOR RESIDENTIAL SMALL-SCALE PV SYSTEMS STANDARD STRING SYSTEM, MICRO-INVERTER, AC MODULE, OR SUPPLY SIDE

Size: px
Start display at page:

Download "EXPEDITED PERMIT PROCESS FOR RESIDENTIAL SMALL-SCALE PV SYSTEMS STANDARD STRING SYSTEM, MICRO-INVERTER, AC MODULE, OR SUPPLY SIDE"

Transcription

1 EXPEDITED PERMIT PROCESS FOR RESIDENTIL SMLL-SCLE P SYSTEMS STNDRD STRIN SYSTEM, MICRO-INERTER, C ULE, OR SUPPLY SIDE Required Information for Permit:. Two copies of site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site. P arrays on dwellings with a perimeter space at ridge and sides may not need separate fire service review.. Two copies of detail, note, elevation, or a combination thereof, indicating P panels installed will be uniformly spaced above the roof surface less than inches from roof surface and the P panels will not extend past roof peak.. Two copies of electrical diagram showing P array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building.. Two copies of specification sheets and installation manuals for all manufactured components including, but not limited to, P modules, inverter(s, combiner box, disconnects, and mounting system.. Printed name and signature of person responsible for design on all pages. Include license number if applicable.. Be advised that if any of the P wiring is installed inside the dwelling, smoke alarms will need to be updated if not to current code per Florida Building Code Residential, Section R. Step : Structural Review of P rray Mounting System Is the array to be mounted on a defined, permitted roof structure? Yes No Roof Information:. Does the roof have a single roof covering? Yes No If No, please describe roof covering: _ Mounting System Information:. The mounting structure shall be engineered or a product approval.. Is the roof flat or sloped? Flat Sloped If sloped, at what pitch? Page of Rev. //08

2 . For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer_Product Name and Model# b. Total Weight of P Modules and Rails lbs c. Total Number of ttachment Points d. Weight per ttachment Point (b±c _ lbs e. Maximum Spacing Between ttachment Points on a Rail inches (see product manual for maximum spacing allowed based on maximum design wind speed f. Total Surface rea of P Modules (square feet ft g. Distributed Weight of P Module on Roof (b±f _ lbs/ft Step : Three-Day Plan Review of P System In order for a P system to be considered for an expedited permit process, the following must apply:. P modules, utility-interactive inverters, and combiner boxes are identified for use in P systems.. The P array is composed of series strings or less per inverter.. The total inverter capacity has a continuous ac power output of 0,000 Watts or less.. One of the standard electrical diagrams can be used to accurately represent the P system.. The P system, when installed on a historic property, is not located on a character defining feature and is not visible from the street.. The P system extends no further than above mounting surface, and is uniformly spaced above a sloped roof surface. 7. The P system does not extend past the roof peak. Step : Separate Permits Required Per the Florida dministrative Code, Rule -.0, Solar contractors may install new or replace existing power and control wiring in photovoltaic (P source circuits, P output circuits, battery storage system circuits, and power conditioning unit. In an interactive system that operates parallel with a primary source of electrical energy, this work is limited to the P supply side of the power conditioning unit. In a stand-alone, or non-grid connected system, the work above-referenced shall be limited to the P supply side of the power conditioning unit and shall not include wiring integral to the building premises. ll work shall be done in accordance with the National Electric Code. ny work integral to the building premises wiring shall be done by a licensed electrical contractor. separate electrical permit will be required for this work, and should be submitted at the same time as the permit application for the P system. Print Name: _ Company Name (if applicable: Signature: License Number (if applicable: Date: Page of Rev. //08

3 EXPEDITED PERMITTIN CHECKLIST FOR RESIDENTIL PHOTOOLTIC SYSTEMS: ROOFTOP MOUNTED Required Paperwork Checklist: This Document Permit pplication with Notice of Commencement for the installation. Separate Electrical permit application if applicable. Small scale P system package with supporting documentation, drawings, and specifications. ❶ Project Information: Project pplicant: Site Owner Name: Project ddress: P system description: ❷ Project Requirements P system is designed and proposed for a detached single family house. P system is designed for rooftop of a house in general compliance with applicable codes. Mounting system is engineered and designed for P. Panels are mounted no higher than above the surface of the roof and are uniformly spaced above the roof surface. No portion of the system exceeds the peak off the roof. If located on a historic property, does the installation comply with the City s historic preservation regulations? Whenever possible, equipment such as solar panels should not be affixed to the building, but sited in the rear or side yard locations and fully screened with landscaping, fence orr wall. When placement upon the building is unavoidable, such equipment shall be located on a non character defining elevation or roof slope that is not visible from the street. In no instance, shall the equipment be allowed to be placed upon any character defining feature. (see beach.org/departments/historic_preservation Method and type of weatherproofing roof penetrations aree provided. Home is code compliant to setbacks and height, or code allows expansion of nonconformity for solar panels. If all above criteria are met, please proceed to determine if project qualifies for an expedited permit. Page of Rev. //08

4 ❸Determine if your project qualifies for an expedited permit ( day turnaround. Solar and Electrical contractors can apply for an expedited permit where the P system meets the requirements listed in this Checklist and use a template electrical diagram provided by the City. ll project plans and supporting documentation must be provided on site for the inspector. Project will be subject to a field inspection. Yes No N/ a P modules, utility interactive inverters, and combiner boxes are identified and listed and labeled for location and use in P systems. b The system meets all current FBC, City, and Electrical Code requirements. c For Split Buss panels the C interconnection must be one of the six service disconnects. d Maximum load added to the panelboard is based on the rating of the P system and is limited to 0,000 watts. e I have attached the following Electrical Template and Site Plan: Electrical Diagram Standard Strings / Standard String with Converter Electrical Diagram Micro Inverter Electrical Diagram C Module Electrical Diagram Supply Side None of the above Electrical Permit with Plan Review Required Comments: If you answered yes to all of the above questions (yes or N/ for item c, and are using a template diagram provided by the City or followed the template and provided a signed and sealed drawing, your project qualifies for an expedited permit. ❹ Submit this Checklist, the Building and Electrical (if applicable Permit pplications with notarized signature, and copies of the Template Electrical Drawing and Site Plan to: Permit Processing, Development Services Dept., 00 E Boynton Beach Blvd., Boynton Beach, FL I attest that all information in this checklist is accurate to the best of my knowledge. pplicant Signature: Date: pplicant Name (Please Print: License Number (if applicable: Electrical Contractor and electrical permit required for all building premises wiring per Florida dministrative Code, Rule.0 and FBC 0. Page of Rev. //08

5 Site Plan Solar merica Board for Codes and Standards Report

6 Standard Electrical Diagram Expedited Permit Process for P Systems

7 Notes for Standard Electrical Diagram SINS SEE UIDE SECTION 7 P ULE STC (uide Section ULE MKE ULE EL MX POWER-POINT CURRENT (I MP MX POWER-POINT OLTE ( MP OPEN-CIRCUIT OLTE ( OC SHORT-CIRCUIT CURRENT (I SC MX SERIES FUSE (OCPD NOTES FOR LL DRWINS: OCPD = OERCURRENT PROTECTION DEICE NTIONL ELECTRICL CODE REFERENCES SHOWN S (NEC XXX.XX INERTER RTINS (uide Section INERTER MKE INERTER EL MX OLT RTIN SIN FOR DISCONNECT PHOTOOLTIC POWER SOURCE RTED MPP CURRENT RTED MPP OLTE MX SYSTEM OLTE MX CIRCUIT CURRENT WRNIN: ELECTRICL SHOCK HZRD LINE ND LOD MY BE ENERIZED IN OPEN POSITION MXIMUM POWER (P MX MX OLTE (TYP 00 OC TEMP COEFF (m/ o C or %/ o C IF COEFF SUPPLIED, CIRCLE UNITS W MX 0 o C NOMINL C OLTE MX C CURRENT MX OCPD RTIN W SIN FOR INERTER OCPD ND C DISCONNECT (IF USED SOLR P SYSTEM C POINT OF CONNECTION C OUTPUT CURRENT NOMINL C OLTE THIS PNEL FED BY MULTIPLE SOURCES (UTILITY ND SOLR NOTES FOR RRY CIRCUIT WIRIN (uide Section and 8 and ppendix D: NOTES FOR INERTER CIRCUITS (uide Section 8 and 9:. LOWEST EXPECT MBIENT TEMPERTURE BSED ON SHRE MINIMUM MEN EXTREME DRY BULB TEMPERTURE FOR SHRE LOCTION MOST SIMILR TO INSTLLTION LOCTION. LOWEST EXPECTED MBIENT TEMP o C IF UTILITY REQUIRES ISIBLE-BREK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/. HIHEST CONTINUOUS MBIENT TEMPERTURE BSED ON SHRE HIHEST MONTH % DRY BULB TEMPERTURE FOR SHRE LOCTION MOST SIMILR TO INSTLLTION LOCTION. HIHEST CONTINUOUS TEMPERTURE _ o C. 00 SHRE FUNDEMENTLS % DESIN TEMPERTURES DO NOT EXCEED 7 o C IN THE UNITED STTES (PLM SPRINS, C IS. o C. FOR LESS THN 9 CURRENT-CRRYIN CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT T LEST 0." BOE ROOF ND USIN THE OUTDOOR DESIN TEMPERTURE OF 7 o C OR LESS (LL OF UNITED STTES, a W, 90 o C CONDUCTORS RE ENERLLY CCEPTBLE FOR ULES WITH Isc OF 7.8 MPS OR LESS WHEN PROTECTED BY -MP OR SMLLER FUSE. b 0 W, 90 o C CONDUCTORS RE ENERLLY CCEPTBLE FOR ULES WITH Isc OF 9. MPS OR LESS WHEN PROTECTED BY -MP OR SMLLER FUSE. IF ENERTION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/ SIZE PHOTOOLTIC POWER SOURCE ( CONDUCTORS BSED ON MX CURRENT ON NEC 90. SIN OR OCPD RTIN T DISCONNECT SIZE INERTER OUTPUT CIRCUIT (C CONDUCTORS CCORDIN TO INERTER OCPD MPERE RTIN. (See uide Section 9 TOTL OF INERTER OCPD(s, ONE FOR ECH INERTER. DOES TOTL SUPPLY BREKERS COMPLY WITH 0% BUSBR EXCEPTION IN 90.(B((a? YES NO ddress and Phone: Notes for One-Line Standard Electrical Diagram for Single-Phase P Systems Site Name: Site ddress: System C Size: SIZE FSCM NO DW NO RE E. SCLE NTS Date: SHEET Solar merica Board for Codes and Standards Report

8 T 7 8 T Micro-Inverter Electrical Diagram EQUIPMENT SCHEDULE DESCRIPTION P or C ULE /C INERTER (MICRO J-BOX (IF USED P RRY C COMB. PNEL (IF USED EN METER (IF USED C DISCONNECT (IF USED SERICE PNEL PRT NUMBER NOTES UTILITY SERICE M C C _ MICRO-INERTERS IN BRNCH- CIRCUIT SEE UIDE PPENDIX D FOR INFORMTION ON ULE ND RRY ROUNDIN C J-BOX M 7 C DISCO 8 MIN OCPD INERTER OCPD C MICRO-INERTERS IN BRNCH- CIRCUIT C C C COMBINER PNEL BUILDIN ROUNDIN ELECTRODE MIN SERICE PNEL FOR UNUSED ULES PUT "N/ in BLNK BOE CONDUIT ND CONDUCTOR SCHEDULE DESCRIPTION OR CONDUCTOR TYPE USE- or P WIRE EC EC X LL THT PPLY EXTERIOR CBLE LISTED W/ IN. THWN- or XHHW- or RHW- EC EC X LL THT PPLY NO EC IF 90. SYSTEM THWN- or XHHW- or RHW- EC EC X LL THT PPLY COND. UE MF MF NUMBER OF CONDUCTORS MF Cable MF Cable CONDUIT TYPE N/ N/ N/ SME SME CONDUIT SIZE N/ N/ N/ SME SME ddress and Phone: One-Line Standard Electrical Diagram for Micro-Inverter P Systems Site Name: Site ddress: System C Size: SIZE FSCM NO DW NO RE SCLE NTS Date: SHEET E.a 0 Expedited Permit Process for P Systems

9 Notes for Micro-Inverter Electrical Diagram SINS SEE UIDE SECTION 7 P ULE STC (uide Section ULE MKE ULE EL NOTES FOR LL DRWINS: OCPD = OERCURRENT PROTECTION DEICE NTIONL ELECTRICL CODE REFERENCES SHOWN S (NEC XXX.XX SIN FOR DISCONNECT No sign necessary since 90. marking on P module covers needed information MX POWER-POINT CURRENT (IMP MX POWER-POINT OLTE (MP OPEN-CIRCUIT OLTE (OC SHORT-CIRCUIT CURRENT (ISC MX SERIES FUSE (OCPD MXIMUM POWER (PMX MX OLTE (TYP 00 OC TEMP COEFF (m/ o C or %/ o C INERTER RTINS (uide Section INERTER MKE INERTER EL MX OLT RTIN MX 0 o C NOMINL C OLTE MX C CURRENT SIN FOR INERTER OCPD ND C DISCONNECT (IF USED SOLR P SYSTEM C POINT OF CONNECTION C OUTPUT CURRENT NOMINL C OLTE THIS PNEL FED BY MULTIPLE SOURCES (UTILITY ND SOLR IF COEFF SUPPLIED, CIRCLE UNITS MX OCPD RTIN NOTES FOR RRY CIRCUIT WIRIN (uide Section and 8 and ppendix E: NOTES FOR INERTER CIRCUITS (uide Section 8 and 9:. LOWEST EXPECT MBIENT TEMPERTURE BSED ON SHRE MINIMUM MEN EXTREME DRY BULB TEMPERTURE FOR SHRE LOCTION MOST SIMILR TO INSTLLTION LOCTION. LOWEST EXPECTED MBIENT TEMP o C IF UTILITY REQUIRES ISIBLE-BREK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/. HIHEST CONTINUOUS MBIENT TEMPERTURE BSED ON SHRE HIHEST MONTH % DRY BULB TEMPERTURE FOR SHRE LOCTION MOST SIMILR TO INSTLLTION LOCTION. HIHEST CONTINUOUS TEMPERTURE o C. 009 SHRE FUNDMENTLS % DESIN TEMPERTURES DO NOT EXCEED 7 o C IN THE UNITED STTES (PLM SPRINS, C IS. o C. FOR LESS THN 9 CURRENT-CRRYIN CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT T LEST 0." BOE ROOF ND USIN THE OUTDOOR DESIN TEMPERTURE OF 7 o C OR LESS (LL OF UNITED STTES, a W, 90 o C CONDUCTORS RE ENERLLY CCEPTBLE FOR ULES WITH Isc OF 7.8 MPS OR LESS WHEN PROTECTED BY -MP OR SMLLER FUSE. b 0 W, 90 o C CONDUCTORS RE ENERLLY CCEPTBLE FOR ULES WITH Isc OF 9. MPS OR LESS WHEN PROTECTED BY -MP OR SMLLER FUSE. IF ENERTION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/ SIZE PHOTOOLTIC POWER SOURCE ( CONDUCTORS BSED ON MX CURRENT ON NEC 90. SIN OR OCPD RTIN T DISCONNECT SIZE INERTER OUTPUT CIRCUIT (C CONDUCTORS CCORDIN TO INERTER OCPD MPERE RTIN. (See uide Section 9 TOTL OF INERTER OUTPUT CIRCUIT OCPD(s, ONE FOR ECH MICRO- INERTER CIRCUIT. DOES TOTL SUPPLY BREKERS COMPLY WITH 0% BUSBR EXCEPTION IN 90.(B((a? YES NO ddress and Phone: Notes for One-Line Standard Electrical Diagram for Single-Phase P Systems Site Name: Site ddress: System C Size: SIZE FSCM NO DW NO RE E.a SCLE NTS Date: SHEET Solar merica Board for Codes and Standards Report 7

10 T 7 T C Module Electrical Diagram EQUIPMENT SCHEDULE DESCRIPTION PRT NUMBER NOTES UTILITY SERICE M C C C ULES IN BRNCH- CIRCUIT C SEE UIDE PPENDIX D FOR INFORMTION ON ULE ND RRY ROUNDIN J-BOX M C DISCO 7 MIN OCPD INERTER OCPD C C C ULES IN BRNCH- CIRCUIT C C COMBINER PNEL BUILDIN ROUNDIN ELECTRODE MIN SERICE PNEL FOR UNUSED C ULES PUT "N/ in BLNK BOE CONDUIT ND CONDUCTOR SCHEDULE DESCRIPTION OR CONDUCTOR TYPE USE- or P WIRE EC EC X LL THT PPLY EXTERIOR CBLE LISTED W/ IN. THWN- or XHHW- or RHW- EC EC X LL THT PPLY NO EC IF 90. SYSTEM THWN- or XHHW- or RHW- EC EC X LL THT PPLY COND. UE MF MF NUMBER OF CONDUCTORS MF Cable MF Cable CONDUIT TYPE N/ N/ N/ CONDUIT SIZE N/ N/ N/ ddress and Phone: One-Line Standard Electrical Diagram for C Module P Systems Site Name: Site ddress: System C Size: SIZE FSCM NO DW NO RE E.b SCLE NTS Date: SHEET 8 Expedited Permit Process for P Systems

11 Notes for C Module Electrical Diagram SINS SEE UIDE SECTION 7 NOTES FOR LL DRWINS: SIN FOR DISCONNECT OCPD = OERCURRENT PROTECTION DEICE NTIONL ELECTRICL CODE REFERENCES SHOWN S (NEC XXX.XX N/ since no dc wiring C ULE RTINS (uide ppendix C C ULE MKE C ULE EL NOMINL OPERTIN C OLTE NOMINL OPERTIN C FREQUENCY MXIMUM C POWER MXIMUM C CURRENT SIN FOR INERTER OCPD ND C DISCONNECT (IF USED SOLR P SYSTEM C POINT OF CONNECTION C OUTPUT CURRENT NOMINL C OLTE THIS PNEL FED BY MULTIPLE SOURCES (UTILITY ND SOLR MXIMUM OCPD RTIN NOTES FOR RRY CIRCUIT WIRIN (uide Section and 8 and ppendix F: NOTES FOR INERTER CIRCUITS (uide Section 8 and 9:. LOWEST EXPECT MBIENT TEMPERTURE BSED ON SHRE MINIMUM MEN EXTREME DRY BULB TEMPERTURE FOR SHRE LOCTION MOST SIMILR TO INSTLLTION LOCTION. LOWEST EXPECTED MBIENT TEMP o C IF UTILITY REQUIRES ISIBLE-BREK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/. HIHEST CONTINUOUS MBIENT TEMPERTURE BSED ON SHRE HIHEST MONTH % DRY BULB TEMPERTURE FOR SHRE LOCTION MOST SIMILR TO INSTLLTION LOCTION. HIHEST CONTINUOUS TEMPERTURE o C. 009 SHRE FUNDMENTLS % DESIN TEMPERTURES DO NOT EXCEED 7 o C IN THE UNITED STTES (PLM SPRINS, C IS. o C. FOR OR LESS CURRENT-CRRYIN CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT T LEST 0." BOE ROOF ND USIN THE OUTDOOR DESIN TEMPERTURE OF 7 o C OR LESS (LL OF UNITED STTES, a W, 90 o C CONDUCTORS RE ENERLLY CCEPTBLE FOR C ULES INERTER OUTPUT CIRCUITS WITH MPS OR LESS WHEN PROTECTED BY - MP OR SMLLER OCPD. IF ENERTION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/ SIZE PHOTOOLTIC POWER SOURCE ( CONDUCTORS BSED ON MX CURRENT ON NEC 90. SIN OR OCPD RTIN T DISCONNECT (N/ SIZE INERTER OUTPUT CIRCUIT (C CONDUCTORS CCORDIN TO INERTER OCPD MPERE RTIN. (See uide Section 9 TOTL OF INERTER OUTPUT CIRCUIT OCPD(s, ONE FOR ECH C ULE CIRCUIT. DOES TOTL SUPPLY BREKERS COMPLY WITH 0% BUSBR EXCEPTION IN 90.(B((a? YES NO b 0 W, 90 o C CONDUCTORS RE ENERLLY CCEPTBLE FOR C ULES INERTER OUTPUT CIRCUITS WITH MPS OR LESS WHEN PROTECTED BY 0- MP OR SMLLER OCPD. ddress and Phone: Bill Notes for One-Line Standard Electrical Diagram for Single-Phase P Systems Site Name: Site ddress: System C Size: SIZE FSCM NO DW NO RE E.b 0 Ted SCLE NTS Date: SHEET Solar merica Board for Codes and Standards Report 9

12 Supply-Side Connected Electrical Diagram EQUIPMENT SCHEDULE T DESCRIPTION PRT NUMBER NOTES 9 0 UTILITY SERICE M 7 8 _ ULES IN SERIES SOURCE-CIRCUIT ULES IN SERIES SOURCE-CIRCUIT ULES IN SERIES SOURCE-CIRCUIT J-BOX COMBINER DISCO INERTER C C DISCO M MIN OCPD MIN SERICE PNEL ULES IN SERIES SOURCE-CIRCUIT FOR UNUSED SERIES STRINS PUT "N/ in BLNK BOE SEE UIDE PPENDIX C FOR INFORMTION ON ULE ND RRY ROUNDIN CONDUIT ND CONDUCTOR SCHEDULE Disregard if provided with inverter BUILDIN ROUNDIN ELECTRODE T DESCRIPTION OR CONDUCTOR TYPE USE- or P WIRE BRE COPPER EQ. RD. COND. (EC THWN- or XHHW- or RHW- THWN- or XHHW- or RHW- INSULTED EC ROUNDIN ELECTRODE COND. THWN- or XHHW- or RHW- INSULTED EC THWN- or XHHW- or RHW- COND. UE NUMBER OF CONDUCTORS CONDUIT TYPE CONDUIT SIZE ddress and Phone: One-Line Electrical Diagram for Supply-Side Connected Single-Phase P Systems Site Name: Site ddress: System C Size: SIZE FSCM NO DW NO RE SCLE NTS Date: SHEET E.c 0 0 Expedited Permit Process for P Systems

13 Notes for Supply-Side Connected Electrical Diagram SINS SEE UIDE SECTION 7 P ULE STC (uide Section ULE MKE ULE EL MX POWER-POINT CURRENT (I MP MX POWER-POINT OLTE ( MP OPEN-CIRCUIT OLTE ( OC SHORT-CIRCUIT CURRENT (I SC MX SERIES FUSE (OCPD NOTES FOR LL DRWINS: OCPD = OERCURRENT PROTECTION DEICE NTIONL ELECTRICL CODE REFERENCES SHOWN S (NEC XXX.XX INERTER RTINS (uide Section INERTER MKE INERTER EL MX OLT RTIN SIN FOR DISCONNECT PHOTOOLTIC POWER SOURCE RTED MPP CURRENT RTED MPP OLTE MX SYSTEM OLTE MX CIRCUIT CURRENT WRNIN: ELECTRICL SHOCK HZRD LINE ND LOD MY BE ENERIZED IN OPEN POSITION MXIMUM POWER (P MX MX OLTE (TYP 00 OC TEMP COEFF (m/ o C or %/ o C IF COEFF SUPPLIED, CIRCLE UNITS W MX 0 o C NOMINL C OLTE MX C CURRENT MX OCPD RTIN W SIN FOR INERTER OCPD ND C DISCONNECT (IF USED SOLR P SYSTEM C POINT OF CONNECTION C OUTPUT CURRENT NOMINL C OLTE THIS PNEL FED BY MULTIPLE SOURCES (UTILITY ND SOLR NOTES FOR RRY CIRCUIT WIRIN (uide Section and 8 and ppendix D: NOTES FOR INERTER CIRCUITS (uide Section 8 and 9:. LOWEST EXPECT MBIENT TEMPERTURE BSED ON SHRE MINIMUM MEN EXTREME DRY BULB TEMPERTURE FOR SHRE LOCTION MOST SIMILR TO INSTLLTION LOCTION. LOWEST EXPECTED MBIENT TEMP o C IF UTILITY REQUIRES ISIBLE-BREK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/. HIHEST CONTINUOUS MBIENT TEMPERTURE BSED ON SHRE HIHEST MONTH % DRY BULB TEMPERTURE FOR SHRE LOCTION MOST SIMILR TO INSTLLTION LOCTION. HIHEST CONTINUOUS TEMPERTURE _ o C. 00 SHRE FUNDEMENTLS % DESIN TEMPERTURES DO NOT EXCEED 7 o C IN THE UNITED STTES (PLM SPRINS, C IS. o C. FOR LESS THN 9 CURRENT-CRRYIN CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT T LEST 0." BOE ROOF ND USIN THE OUTDOOR DESIN TEMPERTURE OF 7 o C OR LESS (LL OF UNITED STTES, a W, 90 o C CONDUCTORS RE ENERLLY CCEPTBLE FOR ULES WITH Isc OF 7.8 MPS OR LESS WHEN PROTECTED BY -MP OR SMLLER FUSE. b 0 W, 90 o C CONDUCTORS RE ENERLLY CCEPTBLE FOR ULES WITH Isc OF 9. MPS OR LESS WHEN PROTECTED BY -MP OR SMLLER FUSE. IF ENERTION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/ SIZE PHOTOOLTIC POWER SOURCE ( CONDUCTORS BSED ON MX CURRENT ON NEC 90. SIN OR OCPD RTIN T DISCONNECT SIZE INERTER OUTPUT CIRCUIT (C CONDUCTORS CCORDIN TO INERTER OCPD MPERE RTIN. (See uide Section 9 TOTL OF INERTER OCPD(s, ONE FOR ECH INERTER. DOES TOTL SUPPLY BREKERS COMPLY WITH 0% BUSBR EXCEPTION IN 90.(B((a? YES NO ddress and Phone: Notes for One-Line Standard Electrical Diagram for Single-Phase P Systems Site Name: Site ddress: System C Size: SIZE FSCM NO DW NO RE E. SCLE NTS Date: SHEET Solar merica Board for Codes and Standards Report

Introduction to the Inspection Checklist for Rooftop Solar Photovoltaic (PV) Systems in Goshen, IN

Introduction to the Inspection Checklist for Rooftop Solar Photovoltaic (PV) Systems in Goshen, IN Introduction to the Inspection Checklist for Rooftop Solar Photovoltaic (PV) Systems in Goshen, IN This Inspection Checklist for Rooftop Photovoltaic (PV) Systems is based on the Model Inspection Checklist

More information

Rapid Shutdown Requirements for NEC 2017

Rapid Shutdown Requirements for NEC 2017 2017 AEESOLAR DEALER CONF. Rapid Shutdown Requirements for NEC 2017 Presented by: Bill Brooks, CMP 4 2017 NEC Statistics for Article 690 Whole article was reduced from 11,000 words to about 8,000 words.

More information

SRI LANKA STANDARD CODE OF PRACTICE FOR GRID CONNECTED PHOTOVOLTAIC POWER SYSTEMS SLS 1522:2016

SRI LANKA STANDARD CODE OF PRACTICE FOR GRID CONNECTED PHOTOVOLTAIC POWER SYSTEMS SLS 1522:2016 SRI LANKA STANDARD CODE OF PRACTICE FOR GRID CONNECTED PHOTOVOLTAIC POWER SYSTEMS SLS 1522:2016 BY H S W Karunaratne Assistant Director - Engineering Sri Lanka Standards Institution. 1 DEFINITIONS Ac module:

More information

Bulletin Installation of Solar Photovoltaic Systems Section 50; Rules: , , ; Tables 11 and 19 Issued July 2010

Bulletin Installation of Solar Photovoltaic Systems Section 50; Rules: , , ; Tables 11 and 19 Issued July 2010 Ontario Electrical Safety Code - Bulletins 50-1-0 Bulletin 50-1-0 Installation of Solar Photovoltaic Systems Section 50; Rules: 84-020, 84-024, 84-030; Tables 11 and 19 Issued July 2010 Scope (1) Introduction

More information

M215 Microinverter Installation Planning

M215 Microinverter Installation Planning TECHNICAL BRIEF M215 Microinverter Installation Planning The M215 Microinverter The M215 Microinverter is a powerful and efficient grid-tied microinverter. It is compatible with most 60- cell PV modules

More information

More Questions from Inspectors Numerous PV Systems Pose Issues

More Questions from Inspectors Numerous PV Systems Pose Issues Perspectives on PV More Questions from Inspectors Numerous PV Systems Pose Issues by John Wiles 76 IAEI NEWS March. April 2012 www.iaei.org Photovoltaic (PV) systems prices continue to drop and inspectors

More information

Renewable Energy Interconnection Manual for Small Size Systems ( 10kW in NM 20kW in TX) Renewables and Emergent Technologies Group

Renewable Energy Interconnection Manual for Small Size Systems ( 10kW in NM 20kW in TX) Renewables and Emergent Technologies Group Renewable Energy Interconnection Manual for Small Size Systems ( 10kW in NM 20kW in TX) Renewables and Emergent Technologies Group Table of Contents 1. Introduction... 1 2. Purpose... 1 3. Customer Eligibility...

More information

Oncor Residential/Small Commercial Project Requirements

Oncor Residential/Small Commercial Project Requirements Oncor Residential/Small Commercial Project Requirements Revised: March 26, 2018 In Effect: May 1, 2018 Equipment (Including all associated equipment) o Batteries o Utility Meter o Generators o Visible

More information

Model Number Electrical Compatibility Module Connector Type M LL-S22 M LL-S22-NA M LL-S23 M LL-S23-NA

Model Number Electrical Compatibility Module Connector Type M LL-S22 M LL-S22-NA M LL-S23 M LL-S23-NA M215 Microinverter Installation Planning The Enphase M215 Microinverter The M215 Microinverter is Enphase s most powerful and efficient model yet. This grid-tied microinverter is compatible with most 60-cell

More information

W POWER OUTPUT RANGE 99.4% THE OPTIMIZED SOLUTION FULLY INTEGRATED LINEAR PERFORMANCE WARRANTY COMPATIBLE WITH MOST TRINA MODULES

W POWER OUTPUT RANGE 99.4% THE OPTIMIZED SOLUTION FULLY INTEGRATED LINEAR PERFORMANCE WARRANTY COMPATIBLE WITH MOST TRINA MODULES Mono Multi Solutions THE OPTIMIZED SOLUTION COMPTIBLE WITH MOST TRIN MODULES 245-310 W POWER OUTPUT RNGE 99.4% OPTIMIZER EFFICIENCY FULLY INTEGRTED SMRT SOLUTION s a leading global manufacturer of next

More information

SECTION ( ) LIGHTING CONTROL PANELBOARD

SECTION ( ) LIGHTING CONTROL PANELBOARD (26 24 16.02) LIGHTING CONTROL PANELBOARD PART 1 GENERAL 1.01 SCOPE A. The Contractor shall furnish and install Lighting Control Panelboards as specified and as shown on the contract drawings. B. The Lighting

More information

W POWER OUTPUT RANGE

W POWER OUTPUT RANGE Mono Multi Solutions THE OPTIMIZED SOLUTION COMPTIBLE WITH MOST TRIN MODULES 265-305W POWER OUTPUT RNGE Safer Solar Panel-level disconnect to remotely deactivate modules rc, fire and safety hazard mitigation

More information

Please read these instructions carefully before installing This will ensure an easy start and a great first customer experience with TS4 installation

Please read these instructions carefully before installing This will ensure an easy start and a great first customer experience with TS4 installation Please read these instructions carefully before installing This will ensure an easy start and a great first customer experience with TS4 installation INTERACTIVE INSTALLATION AND SAFETY MANUAL FOR TS4:

More information

Connection of the Overhead Door Simulator to the Power Lines

Connection of the Overhead Door Simulator to the Power Lines Job Sheet 11 Connection of the Overhed Door Simultor to the Power Lines OBJECTIVE To connect the overhed door simultor to the three-phse power lines. PROCEDURE 1. Perform lockout/tgout to de-energize the

More information

PV Rapid Shutdown device

PV Rapid Shutdown device PV Rapid Shutdown device Installation and Operation Manual Solis-RSD-1G(1:1) Solis-RSD-1G(2:2) Manufacturer: Ginlong (Ningbo) Technologies Co.,Ltd., Ningbo, Zhejiang, P.R.China US Office: 565 Metro Pl.

More information

Microinverters And The Solar Industry

Microinverters And The Solar Industry Microinverters And The Solar Industry Peter Lum Senior Learning And Development Professional Assistant Professor Skyline College Solar Continues Its Growth 2 Significant Growth Of Microinverters in Solar

More information

Stalking the Elusive and Somewhat Strange PV System

Stalking the Elusive and Somewhat Strange PV System A series of articles on photovoltaic (PV) power systems and the National Electrical Code by John Wiles PERSPECTIVES ON PV Stalking the Elusive and Somewhat Strange PV System Photo 1. Framed PV modules

More information

17. Microwave Collocation 17.1 General

17. Microwave Collocation 17.1 General Original Page 1 17.1 General 17.1.1 General A. Unless otherwise specified herein, general regulations contained in Sections 1 through 4 and Sections 14 and 15 apply in addition to the regulations contained

More information

Installation Guide for America Solar Wholesale Photovoltaic Modules

Installation Guide for America Solar Wholesale Photovoltaic Modules Installation Guide for America Solar Wholesale Photovoltaic Modules Mono Module Poly Module 1 ASW Photovoltaic Module Installation Guide Installation guide for American Solar Wholesale Photovoltaic modules

More information

Equipment Short-Circuit Current Rating and Available Fault Current

Equipment Short-Circuit Current Rating and Available Fault Current Equipment Short-Circuit Current Rating and Available Fault Current Dan Neeser Field Application Engineer Eaton s Bussmann Business Dan.Neeser@CooperIndustries.com Agenda Interrupting Rating & Series Rating

More information

Level 2, 3 and 4 Interconnection Application for Certified, Inverter Based Generating Facilities Not Greater than 2MW

Level 2, 3 and 4 Interconnection Application for Certified, Inverter Based Generating Facilities Not Greater than 2MW Level 2, 3 and 4 Interconnection Application for Certified, Inverter Based Generating Facilities Not Greater than 2MW The Customer Generator applicant ("Applicant") hereby makes application to the T &

More information

W POWER OUTPUT RANGE

W POWER OUTPUT RANGE Mono Multi Solutions THE SFER SOLUTION COMPTIBLE WITH MOST TRIN MODULES 265-305W POWER OUTPUT RNGE FULLY INTEGRTED SMRT SOLUTION Founded in 1997, Trina Solar is the world's leading comprehensive solutions

More information

(SEE SECTIONS VII AND VIII OF THE COVENANTS)

(SEE SECTIONS VII AND VIII OF THE COVENANTS) P.0. Box 7035 Covington, Washington 98042 Office (253) 631-9892 * Fax (253) 630-0988 winterwoodhoa@comcast.net Please put ACC Request in e-mail subject line ARCHITECTURAL CONTROL COMMITTEE (ACC) PROJECT

More information

Custom Switchracks: Built to Comply with NEC/CEC Standards From Design to Installation, Appleton is The Switchrack Authority

Custom Switchracks: Built to Comply with NEC/CEC Standards From Design to Installation, Appleton is The Switchrack Authority From Design to Installation, Appleton is The Switchrack Authority With over 80 years in the industry, Appleton is one of the first and the most respected names in custom switchracks for hazardous and adverse

More information

Want to make your inspectors happy?

Want to make your inspectors happy? Want to make your inspectors happy? Mark Baldassari Director, Codes and Standards Agenda Inspectors How to make your inspector happy Common Misconceptions Installing Microinverters Disconnect Means Grounding

More information

Bulletin Installation of solar photovoltaic systems Rules , , , , and

Bulletin Installation of solar photovoltaic systems Rules , , , , and Bulletin 64-5-0 Installation of solar photovoltaic systems Rules 64-060, 64-200, 64-214, 84-020, 84-024 and 84-030 Scope (1) Introduction (2) Disconnecting means (a) Disconnecting means for solar photovoltaic

More information

FORM FOR PROPOSAL FOR 2014 NATIONAL ELECTRICAL CODE

FORM FOR PROPOSAL FOR 2014 NATIONAL ELECTRICAL CODE FORM FOR PROPOSAL FOR 2014 NATIONAL ELECTRICAL CODE INSTRUCTIONS PLEASE READ CAREFULLY Type or print legibly in black ink. Use a separate copy for each proposal. Limit each proposal to a SINGLE section.

More information

PowerFlex 400 AC Drive Guide Specification

PowerFlex 400 AC Drive Guide Specification PowerFlex 400 AC Drive Guide Specification Adjustable Frequency Drives with Bypass 3.0 50HP @ 208V AC 3.0 350HP @ 480V AC PART 1 GENERAL 1.01 Quality Assurance A. The manufacturer shall have minimum 5

More information

SECTION SWITCHBOARDS

SECTION SWITCHBOARDS SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS

More information

Application for Water and/or Sewer Connections

Application for Water and/or Sewer Connections Mailing Address-1201 South Church Street Mount Laurel, NJ 08054 Engineering Office: 81 Elbo Lane Mount Laurel, NJ 08054-9641 Phone: (856) 722-5900 ext. 117 Email: engineering@mltmua.com Fax: (856) 235-0816

More information

TECHNICAL BRIEF. Planning for an IQ Microinverter System. IQ 6 and IQ 6+ Micros

TECHNICAL BRIEF. Planning for an IQ Microinverter System. IQ 6 and IQ 6+ Micros TECHNICAL BRIEF Planning for an IQ Microinverter System The Enphase IQ Microinverter system is inexpensive to install and provides a wide range of new installation options to solar professionals. The IQ

More information

Document C0. Use for:

Document C0. Use for: Date: July 27, 2015 Document C0 Use for: Connection of Electric Generation that will operate with an Open Transition (Category 1) between the Ameren System and the Generator or operate with a Synchronized

More information

Eaton s Innovative Technology Surge Suppression Guideform Specification High Exposure DIVISION 16 SECTION 16289

Eaton s Innovative Technology Surge Suppression Guideform Specification High Exposure DIVISION 16 SECTION 16289 PART 1 - GENERAL DIVISION 16 SECTION 16289 TRANSIENT VOLTAGE SURGE SUPPRESSION (TVSS) 1 RELATED DOCUMENTS General: Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death. Installation/Operation Manual TABLE OF CONTENTS Page UNPACKING AND INSTALLATION Unpacking and Preliminary Inspection...2, 3 Model Number...9 LOCATION CONSIDERATIONS Environment, Equipment Performance,

More information

TECHNICAL AND GENERAL BID REQUIREMENTS

TECHNICAL AND GENERAL BID REQUIREMENTS TECHNICAL AND GENERAL BID REQUIREMENTS The following specifications are similar to those used by several utilities in procuring photovoltaic systems. These specifications help insure the bidders turn in

More information

Eaton s Innovative Technology Surge Suppression Guideform Specification Low Exposure DIVISION 16 SECTION 16289

Eaton s Innovative Technology Surge Suppression Guideform Specification Low Exposure DIVISION 16 SECTION 16289 PART 1 - GENERAL DIVISION 16 SECTION 16289 TRANSIENT VOLTAGE SURGE SUPPRESSION (TVSS) 1.1 RELATED DOCUMENTS General: Drawings and general provisions of the Contract, including General and Supplementary

More information

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System Part 1 General 1.01 Summary A. These specifications describe

More information

DIVISION 16 SECTION Surge Protective Device Submittal (SPD)

DIVISION 16 SECTION Surge Protective Device Submittal (SPD) DIVISION 16 SECTION 16289 Surge Protective Device Submittal (SPD) PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary

More information

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285. SECTION 26 04 75 - SURGE PROTECTION DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Applicable provisions of the General Conditions, Supplementary General Conditions and Special Conditions shall govern work performed

More information

Installation/User Manual

Installation/User Manual Installation/User Manual APsystems YC500-A Photovoltaic Grid-connected Inverter Version 4.1 8/15 APsystems 600 Ericksen Ave. NE Ste 200 Seattle, WA 98110 TEL: 844-666-7035 EMAIL: info@apsystems.com WEB:

More information

Conergy PH Series Modules. Solar module user manual

Conergy PH Series Modules. Solar module user manual Conergy PH Series Modules Solar module user manual 1 Introduction 1.1 Short description Conergy PH modules are solar modules for installation in photovoltaic systems. 1.2 About this manual 1.2.1 Subject

More information

CLASS T JLLN / JLLS SERIES FUSES

CLASS T JLLN / JLLS SERIES FUSES POWR-GRD Fuse Datasheet CLSS T JLLN / JLLS SERIES FUSES 0/ VC Fast-cting - Description JLLN / JLLS fuses are less than / the size of comparable Class R fuses and are typically used for short circuit protection

More information

Meter Enclosure and Equipment Standards

Meter Enclosure and Equipment Standards Meter Enclosure and Equipment Standards (a) (b) General Requirements: CITY OF OCALA UTILITY SERVICES METER ENCLOSURE AND EQUIPMENT STANDARDS: (1) To avoid the costs associated with having to replace unacceptable

More information

Spring Test 9 due 05/11/2013

Spring Test 9 due 05/11/2013 Spring Test 9 due 05/11/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. A grounding electrode is. a. a solid conductor b. a circuit conductor that

More information

PowerLogic High Density Metering System 1-Meter Enclosure

PowerLogic High Density Metering System 1-Meter Enclosure PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these

More information

Superseding SHEET NO. 34C-51 REVISED SHEET NO. 34C-51 Effective May 27, 2010 Effective December 3, 2011

Superseding SHEET NO. 34C-51 REVISED SHEET NO. 34C-51 Effective May 27, 2010 Effective December 3, 2011 Superseding SHEET NO. 34C-51 REVISED SHEET NO. 34C-51 INTERCONNECTION APPLICATION FOR ALL BUT UL1741 CERTIFIED INVERTER BASED SYSTEMS LESS THAN 10 KW In addition to the information provided below, a complete

More information

L70QS SERIES HIGH-SPEED ROUND BODY FUSES

L70QS SERIES HIGH-SPEED ROUND BODY FUSES Vac/dc - Traditional Round Body Bolted Style HF Description The LQS Series is a next generation High-Speed Fuse for the protection of power semiconductor devices and is designed in the Traditional North

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

Max. Input Power (W) Inrush Current (A pk /µs) LED ARRAY

Max. Input Power (W) Inrush Current (A pk /µs) LED ARRAY Electrical Specifications LEDINTA0024V41DLO Max. Power (W) Voltage (V) Current (A) Tcase Max Input Current (A) Max. Input Power (W) Inrush Current (A pk /µs) Max. THD (%) Min. Power Factor Surge Protection

More information

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) Instruction Bulletin 8222-0513B Retain for future use. SPIKESHIELD Wired-In Branch Panels 8222-0513B 05/2012 Table of Contents Precautions...

More information

2.1 MANAGEMENT UNIT INSTALLATION

2.1 MANAGEMENT UNIT INSTALLATION 2 Install the Management Unit and 2.1 MNGEMENT UNIT INSTLLTION Ensure the C and DC disconnect switches are in the OFF position for the inverter. Mount the Maximizer Management Unit (MMU) in a location

More information

Installation/User Manual

Installation/User Manual Installation/User Manual APsystems YC500i Photovoltaic Grid-connected Inverter Version 1.0 7/16 APsystems 600 Ericksen Ave. NE Ste 200 Seattle, WA 98110 TEL: 844-666-7035 EMAIL: info@apsystems.com WEB:

More information

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters Applications Telecom IT Industrial Safety in compliance with IEC60950:1999, 3 rd edition; EN60950:2000; UL60950, 3 rd edition; CSA Standard C22.2 No.60950-00, 3 rd edition Features New, compact design:

More information

Electrical Service Change-Tn Neenah

Electrical Service Change-Tn Neenah Electrical Service Change-Tn Neenah Permit # Owners name Project address Contractors name Contractors address Fax #: Type of occupancy Job description New construction Main panel Single phase Additional

More information

Max. Input Power (W) Inrush Current (A pk /µs)

Max. Input Power (W) Inrush Current (A pk /µs) Output Power (W) Output Voltage (V) Output Current (A) Tcase Max Input Current (A) Max. Input Power (W) Inrush Current (A pk /µs) Max. THD (%) Min. Power Factor Surge Protection (KV) Weight (Lbs) Envir.

More information

6 Buck Boost Transformers

6 Buck Boost Transformers 6 uck oost Transformers uck-oost transformers are small, single phase, dry type distribution transformers designed and shipped as insulating/isolating transformers. They have a dual voltage primary and

More information

MODEL 9360-SO SOCCER SCOREBOARD

MODEL 9360-SO SOCCER SCOREBOARD MODEL 9360-SO SOCCER SCOREBOARD Instruction Manual Address: 34 Main Street, Whitesboro, NY 13492 Phone: 315-736-3967 Toll Free: 800-383-6060 Fax: 315-736-4058 SCOREBOARDS TIMERS MESSAGE SIGNS VIDEO DISPLAYS

More information

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment. SECTION 26 43 00 SURGE PROTECTION DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment. 1.2 DEFINITIONS A. ATS:

More information

Meikai N220/N300 Micro-Inverter Installation and Operation Manual

Meikai N220/N300 Micro-Inverter Installation and Operation Manual Meikai / Micro-Inverter Installation and Operation Manual Version: 1.0 NOTICE: MKSTAR N270: Pairs with most 60-cell PV modules MKSTAR /: Pairs with most 72-cell PV modules Page 1 Copyright MeiKai ENERGY

More information

Xcel Energy Telemetry Requirements for Distributed Energy Resource Interconnections: Revision 3.1

Xcel Energy Telemetry Requirements for Distributed Energy Resource Interconnections: Revision 3.1 Xcel Energy Telemetry Requirements for Distributed Energy Resource Interconnections: Revision 3.1 Version 3.1: September 22, 2017. Please note that this Revision 3.1 may be subject to subsequent revisions.

More information

KRH CVM DWR CDD REVISIONS NOTICE: THE INFORMATION AND DESIGN CONTAINED HEREIN IS THE PROPERTY OF TRANSTECTOR SYSTEMS. WHO RESERVES ALL RIGHTS THERETO

KRH CVM DWR CDD REVISIONS NOTICE: THE INFORMATION AND DESIGN CONTAINED HEREIN IS THE PROPERTY OF TRANSTECTOR SYSTEMS. WHO RESERVES ALL RIGHTS THERETO THIS SPECIFICTION HS BEEN GENERTED ND IS MINTINED BY CD SYSTEM. CHNGES SHLL ONLY BE INCORPORTED S DIRECTED BY THE DESIGN CTIVITY. REVISIONS LTR DESCRIPTION ECO NUM. DTE PPROVED E UPDTE PER REDLINES 13069

More information

Spring Test 16 due 06/14/2013

Spring Test 16 due 06/14/2013 Spring Test 16 due 06/14/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. Figure 234.142 1. Refer to the information shown in Figure 234.142. Motor 1

More information

From Off-The-Shelf to Market-Ready New Age Enclosures is your Single Source Solution. Let us quote modifiying our Stock Enclosures to meet your

From Off-The-Shelf to Market-Ready New Age Enclosures is your Single Source Solution. Let us quote modifiying our Stock Enclosures to meet your From Off-The-Shelf to Market-Ready New ge Enclosures is your Single Source Solution. Let us quote modifiying our Stock Enclosures to meet your end-use. visit newageenclosures.com/services or call 855-4N-ENCL

More information

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS SECTION 264313 - TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and

More information

CenterPoint Energy P O Box 1700 Houston, TX

CenterPoint Energy P O Box 1700 Houston, TX CenterPoint Energy P O Box 1700 Houston, TX 77251-1700 IF YOU ARE APPLYING FOR DISTRIBUTED GENERATION, PLEASE FOLLOW THE INSTRUCTIONS IN THE PARAGRAPHS BELOW. YOU WILL NEED TO COMPLETE AND SIGN AND THEN

More information

Max. Input Power (W) Inrush Current (A pk /µs)

Max. Input Power (W) Inrush Current (A pk /µs) Electrical Specifications LEDINTA0024V41FLO Output Power (W) 100 Output Voltage (V) 24 cv 3.5~24 cc Output Current (A) 0.10~4.16 cv 4.16 cc Tcase Max cv = constant voltage mode, cc = constant current mode

More information

PROFITEST PV Peak Power Measuring Instrument and Curve Tracer for PV Modules and Strings (Measurement at Capacitive Load)

PROFITEST PV Peak Power Measuring Instrument and Curve Tracer for PV Modules and Strings (Measurement at Capacitive Load) Peak Power Measuring Instrument and Curve Tracer for PV Modules and Strings (Measurement at Capacitive Load) 3-349-632-03 1/5.11 Generator voltage up to 1000 V DC, current up to 20 A DC Measurement of

More information

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit

More information

ILUMEN PID SOLUTION INDOOR OUTDOOR ILUMEN PIDBOX MINI INSTALLATION MANUAL. Ilumen PIDbox mini Version 1.5

ILUMEN PID SOLUTION INDOOR OUTDOOR ILUMEN PIDBOX MINI INSTALLATION MANUAL. Ilumen PIDbox mini Version 1.5 ILUMEN PID SOLUTION ILUMEN PIDBOX MINI INSTALLATION MANUAL INDOOR OUTDOOR Ilumen PIDbox mini Version 1.5 1 TABLE OF CONTENT 1 Information on this manual... 3 1.1 Validity... 3 1.2 Target group... 3 1.3

More information

POWER COMBICON spring-cage connector 7.62 mm pitch SPC 5/...-ST(F)-7,62

POWER COMBICON spring-cage connector 7.62 mm pitch SPC 5/...-ST(F)-7,62 spring-cge connector SPC 5/...-ST(F)- Especilly in the high current rnge, the following is true for conductor connection: Time is money. The new spring-cge plug SPC 5 sves both, s due to the quick spring-cge

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist TES A. Roads-Service, Lanes Common Items Trails and service roads provide adequate access to buildings for maintenance B. Testing Results-provided to the local government construction representative Data

More information

GCI-5K INSTALLATION AND OPERATOR S MANUAL

GCI-5K INSTALLATION AND OPERATOR S MANUAL GCI-5K INSTALLATION AND OPERATOR S MANUAL Grid-tied inverter for wind Ningbo Ginlong Technologies 1 INTRODUCTION 2 SAFETY GUIDELINES AND WARNINGS 3 INSTALLATION 3.1 Selecting a location for the inverter

More information

Hardened Ethernet Switch. Signamax Connectivity Systems. Hardened Ethernet Switch. Model G Series. User s Guide

Hardened Ethernet Switch. Signamax Connectivity Systems. Hardened Ethernet Switch. Model G Series. User s Guide Signamax Connectivity Systems Hardened Ethernet Switch Model 065-7405G Series User s Guide 1 Quick Start Guide Hardened Ethernet Switch This quick start guide describes how to install and use the Hardened

More information

MICHIGAN DEPARTMENT OF TRANSPORTATION

MICHIGAN DEPARTMENT OF TRANSPORTATION MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR GROUNDING, BONDING, LIGHTNING PROTECTION AND SURGE PROTECTION FOR INTELLIGENT TRANSPORTATION SYSTEM EQUIPMENT ITS:CLC 1 of 5 APPR:LWB:DBP:07-31-13

More information

Building: Residential Instructions

Building: Residential Instructions Building and Development Services Department 1112 Manatee Ave West, Suite 408 Bradenton, FL 34205 Phone: (941) 749-3012 ManateeBADSOnline@mymanatee.org www.mymanatee.org Building: Residential Instructions

More information

Electrical Components and Equipment for General Use Self Inspection Checklist

Electrical Components and Equipment for General Use Self Inspection Checklist Name of School: Optional Information Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: Electrical Components and Equipment for General Use Self Inspection Checklist Guidelines:

More information

DISTRIBUTED ENERGY RESOURCES NEM PLUS APPLICATION MANUAL

DISTRIBUTED ENERGY RESOURCES NEM PLUS APPLICATION MANUAL DISTRIBUTED ENERGY RESOURCES NEM PLUS APPLICATION MANUAL Reference Guide for the NEM Plus Application This guide is intended to help customers and contractors complete and submit an application for the

More information

Max. Input Power (W) Input Current. Inrush Current

Max. Input Power (W) Input Current. Inrush Current Output Power (W) Output Voltage (V) Output Current (A) Efficiency Tcase Max Input Current Max. Input Power (W) Inrush Current (Apk/µs) Max. THD (%) Min. Power Factor Surge Protection (KV) Weight (Lbs)

More information

HFX 100 Tx and HFX 100 Rx User Guide

HFX 100 Tx and HFX 100 Rx User Guide This guide describes the function, instlltion nd opertion of the trnsmitter nd receiver. Unless otherwise stted, the terms HFX 100, HDMI extender, nd extender refer to both units. The term trnsmitter refers

More information

XBR V3 INSTALLATION AND USER GUIDE Rev 03. xbr V3 Installation and User Guide Page 1 of 14. (preliminary)

XBR V3 INSTALLATION AND USER GUIDE Rev 03. xbr V3 Installation and User Guide Page 1 of 14. (preliminary) XBR V3 INSTALLATION AND USER GUIDE xbr V3 Installation and User Guide Page 1 of 14 Revision History Rev Date Author Description 01 07/03/2012 Eric Anderson Initial release 02 09/25/2012 Eric Anderson Clarification

More information

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001 SLATE Digital I/O Module R8001D4001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform

More information

L70S SERIES HIGH-SPEED FUSE

L70S SERIES HIGH-SPEED FUSE LS SERIES HIGH-SPEED FUSE 0 Vac Vdc 0-0 Traditional Round Body Style Description Littelfuse LS Series High-Speed Fuses are designed to protect today s equipment and systems, and are manufactured with Littelfuse-developed

More information

MODEL 9266 LITTLE LEAGUE BASEBALL SCOREBOARD. Instruction Manual

MODEL 9266 LITTLE LEAGUE BASEBALL SCOREBOARD. Instruction Manual UNITEC MANUFACTURING DIVISION MODEL 9266 LITTLE LEAGUE BASEBALL SCOREBOARD (WITH INNING BY INNING SCORING & PITCH COUNT) Instruction Manual Mailing Address: PO Box 260, Yorkville, NY 13495-0260 Plant Address:

More information

Power Supply (48Vdc, 2.5A)

Power Supply (48Vdc, 2.5A) Telecommunications Group Section 855-180-201 Equipment Issue 1 Fourth Printing, September 2006 8551-80 Power Supply (48Vdc, 2.5A) Compliant with UL Standard 60950, Second Edition* CONTENTS PAGE Part 1.

More information

FS Series PV Modules Reverse Current Overload

FS Series PV Modules Reverse Current Overload FS Series PV Modules Reverse Current Overload Purpose The purpose of this document is: to describe the system conditions that can cause reverse current overload (RCOL) and the behavior of FS modules in

More information

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K) CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K) CRM Applications CRM includes a control relay box and a power supply; additional

More information

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. , Inc. PD402-DMX Four Channel Dimmer and Switch Packs 4 x 2.5 Amps @ 6VDC to 24 VDC DMX52 compatible DMX52 4 x 2.5 Amps Dimmer Pack C UL US LISTED Digital Lighting Systems, Inc. USER'S MANUAL User's Manual

More information

Installation manual. Daikin Altherma low temperature monobloc option box EK2CB07CAV3. Installation manual. English

Installation manual. Daikin Altherma low temperature monobloc option box EK2CB07CAV3. Installation manual. English Instlltion mnul Dikin Altherm low temperture monobloc option box EKCB07CAV Instlltion mnul Dikin Altherm low temperture monobloc option box English Tble of Contents Tble of Contents About the documenttion.

More information

Installation and Operations Manual Micro-Inverter M S

Installation and Operations Manual Micro-Inverter M S Installation and Operations Manual Micro-Inverter M175-24-240-S Release 1.3 Page 1 Copyright Enphase Energy Inc. 2008 Release 1.3 Contact Information Enphase Energy Inc. 201 1 St Street, Suite 111 Petaluma,

More information

Site Preparation CHAPTER

Site Preparation CHAPTER CHAPTER 3 Site Preparation This chapter describes the steps to take and the considerations you should keep in mind prior to installing the modules in an open rack. It also contains information that applies

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16450 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for panelboards providing fault interrupting capability and overcurrent protective devices. 1.02 REFERENCE STANDARDS A.

More information

rcc.1081 Installation Instructions

rcc.1081 Installation Instructions rcc.1081 Installation Instructions Table of Contents Introduction...1 Specifications...2 Mounting...3 Wiring...5 Wiring Method...7 BACnet Network Wiring...8 Setting BACnet Address...9 Setting the BACnet

More information

M250 (M LL) Safety

M250 (M LL) Safety M250 SAFETY M250 (M250-60-2LL) Safety Important Safety Information This document contains important instructions to use during installation of the Enphase M250 Microinverter. To reduce the risk of electrical

More information

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN 1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,

More information

AC Solar Warehouse Installation and Commissioning Checklist

AC Solar Warehouse Installation and Commissioning Checklist AC Solar Warehouse Installation and Commissioning Checklist Installation and Commissioning Checklist AC Solar System Installation and Commissioning Checklist INSTALLATION DETAILS Address of Installation:

More information

Microgeneration Certification Scheme: MCS 005

Microgeneration Certification Scheme: MCS 005 Microgeneration Certification Scheme: MCS 005 Product Certification Scheme Requirements: Solar Photovoltaic Modules Issue 2.5 This Microgeneration Installation Standard is the property of Department of

More information

Short Circuit Current Ratings and AC Drives

Short Circuit Current Ratings and AC Drives Short Circuit Current Ratings and AC Drives Ivan Spronk, Product Marketing AC Drives Schneider Electric Industry NOW Express Goal of this session Understand Importance of proper SCCRs Hot button points

More information

M215 (M215-60) Safety

M215 (M215-60) Safety M215 QUICK INSTALL GUIDE M215 (M215-60) Safety Important Safety Information This document contains important instructions to use during installation and maintenance of the Enphase M215 Microinverter. To

More information

MAJOR VA Power Inverter

MAJOR VA Power Inverter MAJOR500-500 VA Power Inverter The Major500 is a highly reliable, telecom quality, DC to AC power inverter. The Major500 features full electronic protection, high efficiency and low output noise. The built-in

More information

TELECOMMUNICATION FACILITIES SITING AND CONSULTATION POLICY

TELECOMMUNICATION FACILITIES SITING AND CONSULTATION POLICY POLICY P-22 TELECOMMUNICATION FACILITIES SITING AND CONSULTATION POLICY Preamble It is recognized that while reliable and sophisticated telecommunication facilities are a benefit to the citizens of (CSRD),

More information