High Density Cooling Solutions that work from Knurr Kris Holla
|
|
- Hannah Owens
- 5 years ago
- Views:
Transcription
1 High Density Cooling Solutions that work from Knurr Kris Holla The Heat Goes On Ó by
2 Knürr A An International Company Ranked #3 in the world Founded 1931 Strong international setting in over 32 countries Engineering & Manufacturing in Europe, Americas, Asia ~ employees worldwide Focus on Telecom, LAN/Networking, Server/Storage, Data Centers, Traffic/Automotive, Medical Equipment, Security Portfolio of leading global customers Ó by
3 Knurr- Third largest Enclosure company in the world Our Products and Sevices... Rack and enclosure systems + technical furniture Customized solutions & standard products - platform based Level 3 system integration: Mechanics cabling thermal power active components Innovation quality/reliability flexibility speed attractive price Ó by
4 Leader in Networking & Data Center Products Serverracks Cooling Power Supply DI-Strip UPS Cable Management Administration TFT Displays KVM Switches Security Ó by
5 Today we focus on High Density cooling Solutions Contents Capabilities of Liquid Cooling («LC») Water the Domesticated «Beast» - Rack Liquid Cooling GridKa: The World First Completely Watercooled Cluster- A case Study TCO Study Total Cost of Ownership Ó by
6 Can You Pack This into a Serverrack? This is our dilemma today Pizzas: å 12 kw 5 7U Blade Boxes: å 18 kw Ó by
7 Yes You can there is enough space in a 42 U Rack! Ó by
8 But: Can You Cool It? May be if there is enough cold air around it! Ó by
9 Can You Put It Into This Environment? You can but you cannot cool it! Ó by
10 The Limits of Air Cooling - High end datacenters today accommodate only. [HP] Maximum heat load : ~ W/m² ( W/sqft) = 3-4 kw / rack Ó by
11 Is This the Solution? 3,6 kw / rack 4 kw / rack Leave your racks empty? Build new datacenters? Ó by
12 Today The Room is also the Limit [Siemens Business Services] You cannot unleash a hurricane in a room But you can box it in a rack! Ó by
13 It's All About bringing the Cold closer to the Heat - Bring cooling to Enclosure level.not room Rack Liquid Cooling Ó by CPU Liquid Cooling
14 High Density Cooling Solutions that Work-Cooltherm Rack Liquid Cooling Miracel CoolTherm CoolTherm Ó by
15 CoolTherm: Basic Function cooling water connection Ó by
16 The need to Shift to a new approach-water Comes Back...Capabilities of Liquid Cooling (1,000 Watt, DT = 10 C / 18 F) x 3.500! Heat transport ða small water tube can carry more heat than an entire room of air! In other words the amount of heat that can be removed by water is roughly 3,500 times which can be removed by the same volume of air. Security Water has been a standard and safe medium for heat transport in buildings and mainframes for decades. Flexibility Fluid cooling systems can be flexibly adapted to new cooling needs in the datacenter. Ó by
17 CoolTherm - Performance Data kw cooling capacity height up to 54 U / 2600 mm / 102" width 700 or 800 mm / 28 or 32" depth or mm / 48 or 52" 6 or 9U air/water heat exchanger cooling water temp. 12 / 18 C (54/65 F) l/s (6-14 USgal/min) water flow ~ 0.3 bar (4 PSI) pressure drop system pressure ~ 2 3 bar (30-45 PSI) closed air loop m³/h (1,200-3,250 cfm) air flow cooling air temp C (68-77 F) Þ ASHRAE Class 1 recommended envelope Ó by
18 CoolTherm - Main Advantages. ~ 0 heat disspation to the room uniform cooling air temperature over height, enhanced component lifetime for any 19" components water strictly under server compartment 2 or 3 fans / n+1 redundancy cooling control by fan speed monitoring of temperatures, water flow, fan speed, fire detection by RMS low noise emission enhanced protection against smoke, water vapor, high temperature in case of fire Ó by
19 Ultimate Cooling: CoolTherm 22 kw-25kw Ó by
20 Miracel Cooltherm- Closed loop Cooling Benefits... Improved Cooling More Data Processing Dense Packing Sealed System Smoke Sensing Lower Noise levels Improved work areas Fully Monitored In a Nutshell--They are Reliable, Very Economical with Highest performance and Secured.. Ó by
21 The Case Study Project Ó by
22 GridKa: Computing Power for High Energy Physics Pictures/Data: Forschungszentrum Karlsruhe Ó by
23 GridKa: Data Challenge and Hardware Deployment Pictures/Data: Forschungszentrum Karlsruhe Ó by
24 Rack Liquid Cooling for Cluster Computing 4 kw/rack kw/rack Pictures/Data: Forschungszentrum Karlsruhe Ó by
25 GridKa Milestones 2001: Forschungszentrum Karlsruhe starts deployment of a new grid data center «GridKa» Oct 2002: Prototype of world first completely watercooled PC cluster goes into operation Mar 2003: - multiple watercooled server- / storage-racks operating CPUs, 160 TB RAID, 250 TB tape - several hundreds kw cooling capacity (watercooled) Oct more then 60 racks installed - Extension to > 80 racks / ~ 1 MW scheduled for Q1/05 Pictures/Data: Forschungszentrum Karlsruhe - on only 250 m² (2,700 sqft) room size Ó by
26 Rack Liquid Cooling: System Installation Pictures/Data: Forschungszentrum Karlsruhe 1 MW ó Æ 125 mm / 5 Ó by
27 Full Density: Liquid Cooled 12kW Racks / 1 MW (ultimate configuration) on 250m² / 2,700 sqft The worlds first completely watercooled operating cluster - since 2002 Result: Reduction of 240 Racks to 60 Pictures/Data: Racks Forschungszentrum Karlsruhe and Reduction of Floor Space from Sqft to 2500 Sqft. Ó by
28 Economy Ó by
29 TCO Study by DS-Plan Virtual Model Data Center: U servers ("pizzabox") W heat dissipation each - 1 MW in total Removal of heat load by: Option1: Conventional Airconditioning Option 2: Rack Liquid Cooling (Knürr CoolTherm) Ó by
30 Main Impact on Investment: 80% Floor Space Reduction Option1: Conventional Airconditioning - 4 kw / rack - 8 servers / rack racks m² floor space - 4,5 m room height Option 2: Rack Liquid Cooling (Knürr CoolTherm) - 20 kw / rack - 40 servers / rack - 50 racks m² floor space - 3,5 m room height Ó by
31 TCO Study: Investment Cost Investment Costs for Data Center Example ] Investment costs [ % Electric equipment Ventilation 1500 Refrigeration Racks 1000 Required space Conventional Airconditioning Rack Liquid Cooling (CoolTherm) Ó by Please Pleasenote note green bar green barisis removed. removed.
32 TCO Study: Energy Cost Electricity Costs for Data Center Example (without Servers) % /a] Electricity cost [ Recooling plant Compression chillers Racks Recirculated air DC Conventional Airconditioning Rack Liquid Cooling (CoolTherm) Ó by
33 TCO Study: Profitability Calculation Observation Period 15 Years, Service Life of Racks 6 / 12 / 15 Years 500'000 Savings: /a 450'000 Costs [ /a] 400'000 Savings: /a Savings: /a 350' ' ' ' ' '000 50'000 0 Option 1 Option 2 / 6 years Capital-related payments Requirement-related payments Electricity costs Option 2 / 12 years Option 2 / 15 years Operation-related payments Maintenance, inspection and operation Requirement-related payments Waste heat recovery potential Ó by
34 Conclusions Ó by
35 Knurr High Density Cooling Solutions that Work! We offer scalable solutions from 4kw to 25 kw. CPU Liquid Cooling > 100W/CPU Combined Rack + CPU Liquid Cooling Rack Liquid Cooling Forced Air Free Air kw / Rack CoolTherm CoolBoost Miracel Ó by
36 Conclusions Limits of air cooling reached at w 3-4 kw / rack (full density deployment) Liquid cooling overcomes the «heat barrier» and allows high density applications. Technology and products are already available: Complete data center solutions for rack and CPU cooling Liquid cooling provides considerable reduction of - Floor space - Energy consumption - TCO proves that the products work. Knurr has more installations than any body in the world that are Reliable and proven to work.! Ó by
37 Thank You Ó by
38 Knurr High Density Cooling Solutions that Work! CPU Liquid Cooling > 100W/CPU Combined Rack + CPU Liquid Cooling Forced Air Thank You! Rack Liquid Cooling Free Air kw / Rack CoolTherm Miracel CoolBoost Ó by
Rack & Enclosure Systems
Knürr CoolTherm 4 35 KW Energy-efficient Server Cabinet Technology With Outstanding Benefits, To Minimize Energy Costs In The Data Center And Help Reduce Carbon Dioxide Emmisions Rack & Enclosure Systems
More informationMSYS 4480 AC Systems Winter 2015
MSYS 4480 AC Systems Winter 2015 Module 12: DATA CENTERS By Satwinder Singh 14/05/2015 1 Data Centers Data Centers are specialized environments that safeguard your company's most valuable equipment and
More informationECOBAY: Closed loop water cooled server cabinet for data centers
ECOBAY: Closed loop water cooled server cabinet for data centers ELECTRONICS MANUFACTURING SERVICES Communications Computing Multimedia & Consumer Industrial & Semiconductor Defense & Aerospace Medical
More informationCooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.
Cooling on Demand - scalable and smart cooling solutions Marcus Edwards B.Sc. Schroff UK Limited Data Centre cooling what a waste of money! A 1MW data center needs 177,000,000 kwh in its lifetime of 10
More informationPROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES
PROCESS & DATA CENTER COOLING How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES CONGRATULATIONS 2 BOLD PREDICTION 3 Where We Are TODAY Computer Technology NOW advances more
More informationFuture of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power
Future of Cooling High Density Equipment Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power Agenda Issues facing the Data Center Managing the explosive
More informationNext Generation Cooling
Next Generation Cooling Server Manufacturer Perspective Practical and Cost Effective David Moss Data Center Strategist Dell 1 Why Chip, Row, or Rack? Density? Energy Don t be scared; I don t see 50kW/rack
More informationIT infrastructure Next level for data center. Rittal The System Yavor Panayotov Data center Day
IT infrastructure Next level for data center Rittal The System Yavor Panayotov Data center Day - 2018 1 Rittal The System - Solutions Enclosures Enclosures Small enclosures Command Panel & support arm
More informationClose Coupled Cooling for Datacentres
Close Coupled Cooling for Datacentres Dr Fathi Tarada Mosen Ltd fathi.tarada@mosenltd.com www.mosenltd.com Agenda Increasing Power Densities Raised Floor Limitations Hot and Cold Aisle Enclosures Close
More informationReducing Data Center Cooling Costs through Airflow Containment
FEATURE Reducing Data Center Cooling Costs through Airflow Containment Implementing a containment solution in the data center costs much less than the alternatives of adding air handlers or other supplemental
More informationLiebert DCW CATALOGUE
Liebert DCW CATALOGUE Chilled Water-Based High Density Cooling For The Data Center LIEBERT DCW Flexible Approaches For Energy Efficient Cooling Save up to 70% in cooling energy usage Data center managers
More informationLiebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity
Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center Precision Cooling For Business-Critical Continuity Flexible Approaches For Energy Efficient Cooling Save up to 70% in cooling
More informationEnabling Business Critical Continuity for Unified Communications. Andy Liu Product Manager, Asia Pacific
Enabling Business Critical Continuity for Unified Communications Andy Liu Product Manager, Asia Pacific Emerson Creating Technology and Solutions for a World in Action #1 AC & DC Power System #1 OEM Embedded
More informationCooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS
Cooling > Highly efficient cooling products for any IT application. DATA CENTER SOLUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com End-to-End Cooling Solutions from the Closet to the Data
More informationClose-coupled cooling
Close-coupled cooling Intelligently controlled high-performance InRow cooling for the IT environment APC TM by Schneider Electric close-coupled cooling products provide a modular, scalable, and predictable
More informationMission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire
Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101 Nick Gangemi Regional Sales Manager Data Aire Agenda Exactly what are we talking about ASHRAE TC 9.9 Design best practices
More informationSmart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA
Smart Data Centres Robert M Pe, Data Centre Consultant Services SEA 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice Content Data center
More informationKnürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems
Knürr CoolAdd The universal retrofit solution against overheating in server racks Rack & Enclosure Systems Knürr CoolAdd When cold air is no longer enough! Data centers are subject to constant changes:
More informationHIGH DENSITY RACK COOLING CHOICES
WATERCOOLED HIGH PERFORMANCE COMPUTING SYSTEMS AQUILA WHITE PAPER HIGH DENSITY RACK COOLING CHOICES by Phil Hughes Reprinted with permission of Clustered Systems Company, Inc 1 THIS WHITE PAPER DISCUSSES
More informationLCP Hybrid Efficient performance with heat pipe technology
LCP Hybrid Efficient performance with heat pipe technology 2 LCP Hybrid The whole is more than the sum of its parts The same is true of "Rittal The System." With this in mind, we have bundled our innovative
More informationSmartAisle. SmartAisleTM. Energy-efficient use of existing cooling power in data centers to
SmartAisleTM SmartAisle TM Energy-efficient use of existing cooling power in data centers 1.50 to 1.58 1.49 Emerson Network Power Smart Aisle TM The consistent physical separation of cold zones from warm
More informationPower and Cooling for Ultra-High Density Racks and Blade Servers
Power and Cooling for Ultra-High Density Racks and Blade Servers APC White Paper #46 Richard L. Sawyer Director of Data Center Technology American Power Conversion Company 2005 APC corporation What has
More informationCHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw
IT COOLING CLOSE CONTROL AIR CONDITIONERS CHILLED WATER HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw 3 Versions available Single chilled water coil Double chilled water coil High temperature IT COOLING
More informationEnergy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director
Energy Logic: A Roadmap for Reducing Energy Consumption in the Data Center Emerson Network Power Ross Hammond Managing Director Agenda Energy efficiency Where We Are Today What Data Center Managers Are
More informationEnergy Efficient Data Centers
IBM Systems and Technology Group Lab Services Energy Efficient Data Centers Steven Ahladas IBM Corp ahladas@us.ibm.com Keeping our clients in the race. All trends going the same way. IT Servers were an
More informationA) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.
DATA CENTRE COOLING SYSTEM A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems. 1. Cooling Optimized to Electronic
More informationSMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER
SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER Enabling Tomorrow s CRITICAL EDGE INFRASTRUCTURE We helped some of the largest names in the industry bring new capacity online
More informationUsing CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer
Using CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer Agenda What is CFD? Applications of CFD Applicability to the Data Center How it
More informationEfficiency of Data Center cooling
Efficiency of Data Center cooling Comparison of data room layouts and cooling systems Bohumil Cimbal Product manager for Cooling Systems in CONTEG Company Objective Basic questions between investor and
More informationHPC Solutions in High Density Data Centers
Executive Report HPC Solutions in High Density Data Centers How CyrusOne s Houston West data center campus delivers the highest density solutions to customers With the ever-increasing demand on IT resources,
More informationBENEFITS OF ASETEK LIQUID COOLING FOR DATA CENTERS
BENEFITS OF ASETEK LIQUID COOLING FOR DATA CENTERS Asetek has leveraged its expertise as the world-leading provider of efficient liquid cooling systems to create its RackCDU and ISAC direct-to-chip liquid
More informationData Center Trends and Challenges
Data Center Trends and Challenges, IBM Fellow Chief Engineer - Data Center Energy Efficiency Customers challenges are driven by the following Increasing IT demand Continued cost pressure Responsive to
More information18 th National Award for Excellence in Energy Management. July 27, 2017
18 th National Award for Excellence in Energy Management July 27, 2017 ICICI Bank, Data Centre, August Hyderabad 30 & 31, 2017 ICICI Bank - Revolution in Digital Banking Over 100,000 Digital POS in 4 months
More informationInvestor day. November 17, IT business Laurent Vernerey Executive Vice President
Investor day November 17, 2010 IT business Laurent Vernerey Executive Vice President IT business strategic domain Centralized generation Residential Residential Industries Non Residential Transmission
More informationWhere s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden
Where s the Heat Coming From Leland Sparks Global Account Technical Consultant Belden What is the greatest DC challenge you face? Air Flow to Heat Load Relation Server Inlet Fans Chips Outlet LOAD Dell
More informationPlanning for Liquid Cooling Patrick McGinn Product Manager, Rack DCLC
Planning for Liquid Cooling -------------------------------- Patrick McGinn Product Manager, Rack DCLC February 3 rd, 2015 Expertise, Innovation & Delivery 13 years in the making with a 1800% growth rate
More informationTotal Modular Data Centre Solutions
Sector Data Centre Total Modular Data Centre Solutions www.airedale.com BRITISH MANUFACTURER ENERGY EFFICIENCY CONTROLS SERVICE TRAINING 01 Standardised Modular Designs to fit your needs Our modular system
More informationLCS Value Proposition November 2014
LCS Value Proposition November 2014 Data Center Trends 2014 Improving Data Center Power Efficiency & Reducing Carbon Footprint Initiatives for raising data center temperatures Data center upgrades for
More informationHigh Efficient Data Center Cooling
Nordborg High Efficient Data Center Cooling Copenhagen Center on Energy Efficiency webinar 12. July 2017 Jörg Saar, Danfoss Cooling 1 Danfoss Cooling Contents 1. Short intro to Danfoss Cooling 2. Introduction
More informationDATA CENTER LIQUID COOLING
DATA CENTER LIQUID COOLING EFFICIENT, EFFECTIVE, SUSTAINABLE What is Liquid Cooling? Key Trends & Potential Inhibitors Why are Many Owner/Operators Making the Move? Types of Liquid Cooling Solutions Liquid
More informationRittal LCP T3+ High-availability IT cooling with no compromise
Rittal LCP T3+ High-availability IT cooling with no compromise LCP T3+, the climate for maximum availability... in the financial world Admittedly, we have no solution for overheated markets. But we do
More informationRittal Cooling Solutions A. Tropp
1 Rittal Cooling Solutions Presented by Adam Tropp 2 Agenda Cooling Strategies Aisle Containment Chimney Solution Airstream Management Rittal Liquid Cooling Packages Data Monitoring 3 Cooling strategies.
More informationSchneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions
Schneider Electric Cooling Portfolio Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions Data Center Cooling Agenda 1. How to size data center, server rooms, IDF rooms, etc in
More informationGreen Data Centers A Guideline
Green Data Centers A Guideline Sekhar Kondepudi Ph.D Associate Professor Smart Buildings & Smart Cities Vice Chair Focus Group on Smart Sustainable Cities ITU-TRCSL Workshop on Greening the Future: Bridging
More informationNREL Validates LCS Technology. PRESENTED BY Herb Zien CEO, LiquidCool Solutions
NREL Validates LCS Technology PRESENTED BY Herb Zien CEO, LiquidCool Solutions Learning Objectives As much as 40% of data center power is used to circulate air, and fans in a typical 30-megawatt data center
More informationData Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server
Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server High availability for lower expertise
More informationCombining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency
A White Paper from the Experts in Business-Critical Continuity TM Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency Executive Summary Energy efficiency
More informationRecapture Capacity for Existing. and Airflow Optimization
Recapture Capacity for Existing Data Centers Through Cooling and Airflow Optimization Introduction Challenges and Trends Agenda Cooling & Airflow Optimization Takeaways Learning Objectives Recognize opportunities
More informationMaking the impossible data center a reality.
United Nations ITU WSIS 2016 WINNER E-Environment Malaysia s First Win 2015 ASIA PACIFIC WINNER 2015 Best of Sustainability and Environmental Technology WINNER 2015 Best of Sustainability and Environmental
More informationProduct Guide. Direct Contact Liquid Cooling Industry leading data center solutions for HPC, Cloud and Enterprise markets.
Product Guide Direct Contact Liquid Cooling Industry leading data center solutions for HPC, Cloud and Enterprise markets. www.coolitsystems.com Phone: +1 403.235.4895 The Future of Data Center Cooling
More informationVariable Density, Closed-Loop, Water-Cooled Data Center Solution
Variable Density, Closed-Loop, Water-Cooled Data Center Solution Overview Great Lakes Case & Cabinet Co., Inc. has worked with Naissus Thermal Management Solutions, of Toronto, Ontario to develop one of
More informationSmartAisle Intelligent, Integrated Infrastructure Using Row-based Building Blocks. Solutions For Business-Critical Continuity
SmartAisle Intelligent, Integrated Infrastructure Using Row-based Building Blocks Solutions For Business-Critical Continuity Deploy An Efficient and Flexible Row-Based Infrastructure Efficiency. Capacity.
More informationSwitch to Perfection
Switch to Perfection Traditional Data Centre - Temperatures Ideal Air Temperature: 22 C Chilled Water: 7-9 C Heat Load per Rack: Up to 4,5 Chilling & Pump Set The challenge a thermal image Front View of
More informationPerfect Cooling. A perfect climate for high performance servers
Perfect Cooling A perfect climate for high performance servers High Performance Cooling Modular, scalable, efficient Despite a dramatic rise in climate control requirements, cooling practice in many companies
More informationEffectiveness and Implementation of Modular Containment in Existing Data Centers
WHITE PAPER Effectiveness and Implementation of Modular Containment in Existing Data Centers By Lars Strong, P.E., Upsite Technologies, Inc. Bruce Long, Upsite Technologies, Inc. 505.798.0200 upsite.com
More information) ) page 04. page 07. page 10. page 10. page 12. page 14. page 14. page 16. page 18. page 19. page 19. page 20. page 21. page 22
english version SAIFOR ADVANCED COOLING SOLUTIONS HDC AISLE HIGH DENSITY COOLING MDC AISLE HDC RACK MDC RACK CUBO KEEP-COOL HTRD CADU MAIN FEATURES CONFIGURATIONS & ACCESSORIES CUBO ACCESSORIES ) ) MEDIUM
More information7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America
7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer
More informationA Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System
A Data Center Heat Removal System That Saves... Infrastructure Power Water up to 40% up to 80% up to 85% Discover Inertech s Award-winning Data Center Heat Removal System A Cool Solution; A Breakthrough
More informationPower & Cooling Considerations for Virtualized Environments
Power & Cooling Considerations for Virtualized Environments Cisco Data Center Day 2008 31-01-2008 APC-MGE Vision & Mission OUR VISION APC-MGE products ensure availability wherever data is created, transmitted
More informationQuickSpecs. HP Performance Optimized Datacenter (POD) 20ce. Overview. Retired
Overview The HP Performance-Optimized Data Center (HP POD) is a containerized datacenter equipped with power infrastructure, cooling and IT power distribution. The HP POD can be deployed within weeks instead
More informationLiquid Cooling Package LCP Cooling Systems
Liquid Cooling Package LCP Cooling Systems 2 Rittal LCP The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure,
More informationSystems and Technology Group. IBM Technology and Solutions Jan Janick IBM Vice President Modular Systems and Storage Development
Systems and Technology Group IBM Technology and Solutions Jan Janick IBM Vice President Modular Systems and Storage Development Power and cooling are complex issues There is no single fix. IBM is working
More informationHow to Increase Data Center Efficiency
How to Increase Data Center Efficiency Shivani Shukla Potkar Product Marketing Manager Pentair Electronics Protection High cooling efficiency & and reduced power consumption enhances the balance between
More information100% Warm-Water Cooling with CoolMUC-3
100% Warm-Water Cooling with CoolMUC-3 No chillers, no fans, no problems Axel Auweter MEGWARE CTO Workshop on Energy Efficiency in HPC May 30, 2018, Ljubljana!1 MEGWARE Computer Vertrieb und Service GmbH
More informationIncreasing Data Center Efficiency by Using Improved High Density Power Distribution
Increasing Data Center Efficiency by Using Improved High Density Power Distribution By Neil Rasmussen White Paper #128 Revision 1 Executive Summary A new approach to power distribution for high density
More informationPrecision Cooling. Precision Cooling Advantages
Precision Cooling Today s computing technologies compound conventional cooling problems. Blade servers, communications switches and other electronics are being packed into tighter and tighter spaces. Computing
More informationDATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency
DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency September 27 th, 2013 Tejas Desai, PE CEM CEA LEED AP Sameer Behere, PE CEM LEED AP Agenda Problem: Quick fixes can
More informationVirtualization and consolidation
Virtualization and consolidation Choosing a density strategy Implementing a high-density environment Maximizing the efficiency benefit Anticipating the dynamic data center Schneider Electric 1 Topical
More informationAisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings
WHITE PAPER AisleLok Modular Containment vs. : A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings By Bruce Long, Upsite Technologies, Inc. Lars Strong, P.E., Upsite Technologies, Inc.
More informationTWO FINANCIAL IMPACT STUDIES. Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months
TWO FINANCIAL IMPACT STUDIES Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months TWO FINANCIAL IMPACT STUDIES Seal IT Equipment Cabinets for Significant
More informationData Center Airflow Management Basics: Comparing Containment Systems
WHITE PAPER Data Center Airflow Management Basics: Comparing Containment Systems Edited by David Knapp Product Marketing Manager Published: February 2017 US & Canada +1-800-834-4969 Toronto, Ontario, Canada
More informationPlanning a Green Datacenter
Planning a Green Datacenter Dr. Dominique Singy Contribution to: Green IT Crash Course Organisator: Green IT Special Interest Group of the Swiss Informatics Society ETH-Zurich / February 13, Green Data
More informationThe Evolving Data Center
The Evolving Data Center Dominic Loh Product Manager, Power Quality, APAC Data Centers are enabling global growth Proliferation of mobile computing Digitalization of everything Big Data 2 Evolution of
More informationMoving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet
Moving Containment Inside the Enclosure Presented by Jeff Markle Great Lakes Case & Cabinet Containment Containment : To put constraint upon; to restrain; to confine; to keep within bounds Containment
More informationGreen IT and Green DC
Green IT and Green DC Alex SL Tay Regional Service Product Line Manager Site & Facilities Services, IBM ASEAN 1 What our clients are telling us We are running out of space in our data center We have environmental
More informationOne Stop Cooling Solution. Ben Tam Business Development Manager
One Stop Cooling Solution Ben Tam Business Development Manager Agenda One Stop Cooling Solution Challenges Customers Are Facing Today Rack / Row / Room Solution Keynotes New Product Launch Slide 2 2 One
More informationBrad Nacke Enterprise Account Leader Data Centers
Brad Nacke Enterprise Account Leader Data Centers United Technologies Makes Modern Life Possible Commercial Aerospace Employees: ~56,000 Sales: $16.9B Employees: ~67,000 Sales: $12.0B Employees: ~35,000
More informationData Sheet FUJITSU Server PRIMERGY CX400 M1 Scale out Server
Data Sheet FUJITSU Server Scale out Server Data Sheet FUJITSU Server Scale out Server Scale-Out Smart for HPC, Cloud and Hyper-Converged Computing FUJITSU Server PRIMERGY will give you the servers you
More informationWhat s New for Data Centers in Title Jeff Stein, PE Taylor Engineering
What s New for Data Centers in Title 24-2013 Jeff Stein, PE Taylor Engineering SVLG Workshop November 14, 2013 About Jeff Stein Principal, Taylor Engineering 2000 - now Professional Experience Eley Associates,
More informationHighly Efficient Power Protection for High Density Computing Applications
Highly Efficient Power Protection for High Density Computing Applications IB Power and Cooling Symposium Lennart Jonsson Eaton Corporation 2007 Eaton Corporation. All rights reserved. Impact of High Density
More informationCritical Facilities Round Table SUN Microsystems Friday, March 25, Thursday, March 24, 2005 Wright Line LLC,
Critical Facilities Round Table SUN Microsystems Friday, March 25, 2005 Thursday, March 24, 2005 Wright Line LLC, 2003 1 Topic of Discussion Can standardization, non-uniform and high heat densities co-exist
More informationSmart Solutions Intelligent, Integrated Infrastructure for the Data Center
Solutions For Business-Critical Continuity Smart Solutions Intelligent, Integrated Infrastructure for the Data Center DATA CENTER SOLUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com Deploy
More informationANCIS I N C O R P O R A T E D
Thermal Design of Data Centers to Safeguard Electronic Equipment Presentation at the Thermal Design Center Santa Clara, CA, March 9, 2010 Magnus K. Herrlin, Ph.D. President Incorporated mherrlin@ancis.us
More informationPassive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer
Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling Jeremiah Stikeleather Applications Engineer Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling While CRAH cooling has been
More informationWater-Cooling and its Impact on Performance and TCO
Water-Cooling and its Impact on Performance and TCO Matthew T. Ziegler Director, HPC and AI WW BU System Strategy and Architecture mziegler@lenovo.com 2016 Lenovo Internal. All rights reserved. 1 Agenda
More informationDATA CENTER AIR HANDLING COOLING SOLUTIONS
DATA CENTER AIR HANDLING COOLING SOLUTIONS World-class performance and reliability from YORK As data storage and protection needs grow, so can costs and complexity. That s why having the right partner
More informationIntroducing the Heat Wheel to the Data Center
Introducing the Heat Wheel to the Data Center Robert (Dr. Bob) Sullivan, Ph.D. Data Center Infrastructure Specialist KyotoCooling International Critical Facilities Round Table 1 A New Free Cooling Technique
More informationHow High-Density Colocation and Enhanced Visibility Improve Business Performance
How High-Density Colocation and Enhanced Visibility Improve Business Performance Steven So Vice President Data Center Business Cloud Business Division NTT Com Asia Limited 11 Sep 2015 NTT Communications
More informationCreating an Energy-Efficient, Automated Monitoring System for Temperature and Humidity at a World-Class Data Center
About CyrusOne CyrusOne is a world-renowned enterprise data center provider that offers 40 data centers across the U.S., Europe and Asia with a three million-plus square feet of total net rentable space.
More informationExperimental Study of Airflow Designs for Data Centers
Experimental Study of Airflow Designs for Data Centers Takashi Tsuchiya*, Yoshihide Suwa 2 and Ryozo Ooka 3 Technical Research Institute, Obayashi Corporation, M. Eng., Japan 2 Technical Research Institute,
More informationData Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node
Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node Standard server node for PRIMERGY CX400 M1 multi-node server system
More informationENCLOSURE HEAT DISSIPATION
ENCLOSURE HEAT DISSIPATION DATA CENTER SOLUTIONS A White Paper by Great Lakes Case & Cabinet Company www.werackyourworld.com 814.734.7303 Page 2 Introduction Dangerous heat levels inside an enclosure threaten
More informationLiebert XD. Cooling Solutions For High Heat Density Applications. Precision Cooling For Business-Critical Continuity
XD Cooling Solutions For High Heat Density Applications Precision Cooling For Business-Critical Continuity High Density. High Temperatures Today s data center technologies compound conventional cooling
More informationData Centre Stockholm II, Sweden Flexible, advanced and efficient by design.
Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design. TelecityGroup Kvastvägen 25-29 128 62 Sköndal Stockholm Sweden Tel: +46 (0) 8 799 3800 se.info@telecity.com www.telecitygroup.se
More informationProduct Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres
Product Brochure DENCO Close Control Units Row-DENCO High Density Cooling for Data Centres Data Centre Cooling Through a history in close control, we have developed a broad and deep understanding of how
More informationThe TeliaSonera Green Room Concept for high and mid density ICT equipment
The TeliaSonera Green Room Concept for high and mid density ICT equipment Svante Enlund BA Broadband Services, Technology Solutions TeliaSonera Stockholm, Sweden Svante.Enlund@teliasonera.com Dag Lundén
More informationM+W Group s Visionary Delta Datacenter
Region Central Europe M+W Germany GmbH A Company of the M+W Group 23 rd April 2014 M+W Group s Visionary Delta Datacenter IKS Data Center Design & Engineering Conference 2014 Moscow, Russia M+W Group at
More informationHigh Tech Getting Too Hot? High Density Environments Require A Different Cooling Approach
High Tech Getting Too Hot? High Density Environments Require A Different Cooling Approach Proper airfl ow and thermal management are the most critical aspects of designing and operating your data center,
More informationApplication of Green Technology For Data Centre
Application of Green Technology For Data Centre Steven So Vice President Data Centre Business Cloud Business Division NTT Com Asia Limited 25 Sep 2013 Today s Agenda Why? How? What? Business Drivers
More information84 kw, Tier 3, Direct Expansion, 937 ft 2
[Reference Design 42] 84 kw, Tier 3, Direct Expansion, 937 ft 2 DESIGN OVERVIEW Data Center IT Capacity 84 kw Target Availability Tier 3 Annualized PUE at 100% Load 1.712 Total Racks and Average Density
More information