1008 kw, Tier 2, Chilled Water, ft 2

Size: px
Start display at page:

Download "1008 kw, Tier 2, Chilled Water, ft 2"

Transcription

1 [eference Design 81] 1008 kw, Tier 2, hilled Water, ft 2 DESIGN OVEVIEW Data enter IT apacity 1008 kw Adaptable from 200 kw to 3024 kw Target Availability Tier 2 Annualized PUE at 100% Load 1.65 in Miami, FL USA 1.46 in Montreal, anada 1.54 in St. Louis, MO USA Total acks and Average Density 336 racks at 3 kw/rack INTODUTION The planning process of most projects can be iterative and thereby expensive. Data center projects are burdened with these challenges and can benefit greatly from simplification and time savings. Schneider Electric s data center reference designs help optimize the planning process by providing validated, proven, and documented data center physical infrastructure plans. The use of these designs has a positive impact on not just the project itself, but also on the performance, reliability, and efficiency of the data center over its lifetime. eference Design 81 includes information for three areas: facility power, facility cooling, and the IT space. ombined together, they comprise the integrated facility power, facility cooling and structural systems required to meet the design s specifications in this overview document. IT & Facility Floor Space ft 2 egional Voltage and Frequency 480V, 60Hz AOUT THIS DESIGN Plug-in iusway for flexible and easy power circuit deployment Air-cooled, packaged chiller cooling architecture Energy savings through waterside economizer during favorable outdoor conditions Highly scalable and adaptable

2 [eference Design 81] 2 Facility Power DESIGN OPTIONS This reference design can be modified as follows without a significant effect on the design s performance attributes: Add StruxureWare Power Monitoring Expert Provision for load bank hange UPS batteries (classic or modular batteries, short/ long backup times) Add/change standby generator options (location, tank size, fuel type) The facility power system provides power to all of the critical and non-critical components within the datacenter. It consists of a single power path with N+1 UPSs, backed up by N+1 generators, to achieve a Tier 2 redundant architecture. The facility power system has a QED-2 switchboard with a 3200 amp main bus that feeds both the IT space and facility cooling UPSs. One 1.4 MW Symmetra MW UPS serves as the IT space UPS. A 60 kva Galaxy 5000 UPS supplies protected power to N+1 pumps. The main bus also feeds an I-Line facility cooling distribution panel, providing power to N+1 chillers in the mechanical space. The power distribution architecture from the electrical space to the IT space utilizes a combination of LV power panels and the iusway power distribution system. The design can also support additional peripheral devices like lighting, access control systems, and environmental monitoring and control devices. Power meters integrate with (optional) StruxureWare Power Monitoring Expert to monitor power quality and allow for predictive maintenance & diagnostics of the system. Every component in this design is built and tested to the applicable ANSI, NEMA, UL or IEEE standards. Design details and schematics are available in the Engineering Package (see page 7). FAILITY POWE LOK DIAGAM 3200A, 480V, 65kA 60kVA UPS Galaxy A, 480V, 65kA 3 HW Pumps 1200A, 480V, 65kA 3 Packaged hiller Utility A HUM G G 2000A, 480V, 65kA 1.4MW UPS Symmetra MW 1600A, 480V, 65kA 480V 208/120V 4x 300kVA 16 iusway Feeds to 8 IT Pod 2x oom ooler 225A, 480V, 65kA 13 AHs FAILITY POWE ATTIUTES Name Value Unit Total amps (main bus) 3200 A Input voltage (main bus) 480 V Switchboard kai 65 ka Power path Generator redundancy N+1 IT space UPS capacity 1200 kw IT space UPS redundancy N+1 IT space UPS rated load 5 minutes IT space UPS output voltage 480 V Facility cooling UPS capacity 54/60 kw/kva Facility cooling UPS redundancy N Facility cooling UPS rated load 5 minutes Document Number D81DS evision 0 / Nov 2014

3 [eference Design 81] 3 Facility ooling DESIGN OPTIONS This reference design can be modified as follows without a significant effect on the design s performance attributes: Add StruxureWare ooling Monitoring Expert FAILITY OOLING LOK DIAGAM W supply W return Uniflair W 13 units... Uniflair W Uniflair W IT Space The facility cooling design is comprised of a chilled water cooling system in the IT space, integrated with a single chilled water loop with N+1 pumps in the mechanical space and an N+1 packaged chiller outdoors. Altogether, they form a Tier 2 redundant architecture. The facility cooling contains three 700 kw air-cooled water chillers with axial fans and a free-cooling system. Economization is achieved with dry coolers integrated within the chiller to save energy during favorable outdoor conditions. A thermal storage system is offered as an option to provide 5 minutes of continuous cooling after a power outage or chiller restart. The piping architecture feeds room-based Uniflair chilled water AHs in the IT space. It also feeds room-based Uniflair AHs in the electrical space. More information on the cooling configuration is provided in the IT space section of this document. This design is instrumented to work with (optional) StruxureWare ooling Monitoring Expert. Design details such as dimensions, equipment placement, temperature set points, pipe sizing, flow rates, and pressure drops are available in the Engineering Package (See page 7). FAILITY OOLING ATTIUTES Name Value Unit Total cooling capacity 1400 kw hilled Water Mechanical redundancy N+1 Outdoor heat exchange Air-ooled, Packaged hiller oolant supply temperature 59 F oolant return temperature 69 F Storage tank size (optional) 5000 gallons ide-through time 5 minutes Packaged hiller 700kW VFD VFD VFD Expansion tank Dirt/air separator Economizer type hilled Water eturn Water-Side Packaged hiller 700kW hemical dosing pot System bypass Packaged hiller 700kW hilled Water Supply uffer Tank (optional) Document Number D81DS evision 0 / Nov 2014

4 2014 Schneider Electric. All rights reserved. [eference Design 81] 4 IT Space DESIGN OPTIONS This reference design can be modified as follows without a significant effect on the design s performance attributes: Add environmental and security management hange rack options (tall, wide, deep) hange power distribution options (ack PDU type: basic, switched) Add StruxureWare Data enter Expert A single power distribution path from the electrical space powers the Tier 2 IT space, consisting of 180 kw of critical cooling load and 1008 kw of critical IT load, fed by busway in an N configuration. 336 NetShelter racks of an average 3 kw per rack density are arranged in a highly scalable and adaptable pod fashion. Smaller starting loads can be supported by making adjustments such as reducing the number of IT pods or decreasing the capacity of the UPS. Likewise, larger loads can be reached by using a step and repeat approach with this design as the baseline. This flexibility drives efficiency and defers capital expenditure until needed. Each pod is powered by two 225A iusway power distribution lines. Each rack is configured with a metered rack-mount PDU to enable remote monitoring of the units for efficiency and capacity management. Uniflair chilled water room-based AHs, in an N+1 configuration, control the removal of heat by monitoring the temperature in the room and the pressure in the contained hot aisle. The security of the room is maintained at multiple points. At the rack level, access is controlled by a door lock and sensor. At the room level, security cameras are utilized for monitoring. Design details and schematics are available in the Engineering Package (see page 7). IT SPAE LOK DIAGAM IT SPAE ATTIUTES Name Value Unit IT load 1008 kw Supply voltage to IT 208 V Average density 3 kw/rack Number of racks 336 racks IT floor space ft 2 or dual cord hilled Water A/AH type oom-ased AH A/AH redundancy N+1 ontainment type Hot-Aisle Document Number D81DS evision 0 / Nov 2014

5 [eference Design 81] 5 Design Attributes OVEVIEW Value Unit Target availability Tier 2 Tier Annualized PUE at 100% load 1.65 / 1.46 / 1.54 Data center IT capacity 1008 kw IT & facility floor space ft 2 Average density 3 kw/rack FAILITY POWE Value Unit Total amps (main bus) 3200 A Input voltage (main bus) 480 V Switchboard kai 65 ka Power path Generator redundancy N+1 IT space UPS capacity 1200 kw IT space UPS redundancy N+1 IT space UPS rated load 5 minutes IT space UPS output voltage 480 V Facility cooling UPS capacity 54/60 kw/kva Facility cooling UPS redundancy N Facility cooling UPS rated load 5 minutes FAILITY OOLING Value Unit Total cooling capacity 1400 kw hilled Water Mechanical redundancy N+1 Outdoor heat exchange Air-ooled, Packaged hiller oolant supply temperature 59 F oolant return temperature 69 F Storage tank size (optional) 5000 gallons ide-through time 5 minutes Economizer type Water-Side IT SPAE Value Unit IT load 1008 kw Supply voltage to IT 208 V Average density 3 kw/rack Number of racks 336 racks IT floor space ft 2 or dual cord hilled Water A/AH type oom-ased AH A/AH redundancy N+1 ontainment type Hot-Aisle Document Number D81DS evision 0 / Nov 2014

6 [eference Design 81] 6 Data enter Infrastructure Management (DIM) System Good design and quality construction alone do not ensure a highly available & efficient data center. DIM provides on-going monitoring and control to ensure the facility lives up to its design intent. StruxureWare for Data enters is a software management suite designed to collect and manage data about a data center s assets, resource use, and operational status throughout the life cycle of the facility. This information is then distributed, integrated, and applied in ways that help managers optimize the data center s performance and meet IT, business, and service-oriented goals. From IT assets to racks, rows, rooms and buildings, StruxureWare for Data enters delivers the right information to the right users at the right time. ontrol level: Experts, on site or remotely, can control process performance and ensure business continuity in real time, while tracking energy consumption in a highly critical and secure environment. Operations level: Functional managers can optimize operations, energy, and assets through smart analytical tools, often spanning multiple sites. Enterprise level: -level executives can drive their sustainability strategy efficiently, choosing the best scenario that meets their business objective to conserve enterprise-wide resources. StruxureWare for Data enters allows for flexibility when requirements and implementation strategies change over time. StruxureWare software applications and suites simplify integration time, improve reliability, enhance visibility to energy information, and streamline operational efficiency. Demo: >Visit to learn more about StruxureWare for Data enters! Document Number D81DS evision 0 / Nov 2014

7 [eference Design 81] 7 Schneider Electric Life-ycle Services Team of over 7,000 trained specialists covering every phase and system in the data center Standardized, documented, and validated methodology leveraging automation tools and repeatable processes developed over 45 years omplete portfolio of services to solve your technical or business challenge, simplify your life, and reduce costs Get more information for this design: Engineering Package 3D spatial views Floor layouts Every reference design is built with technical documentation for engineers and project managers. This includes engineering schematics (AD, PDF), floor layouts, equipment lists containing all the components used in the design and 3D images showing real world illustrations of our reference designs. Documentation is available in multiple formats to suit the needs of both engineers and managers working on data center projects. ill of materials One-line schematics > lick here to register to receive the Engineering Package for this design, or eferencedesigns@schneider-electric.com. Document Number D81DS evision 0 / Nov 2014

200 kw, Tier 3, Chilled Water, 5250 ft 2

200 kw, Tier 3, Chilled Water, 5250 ft 2 [eference Design 4] 200 kw, Tier 3, Chilled Water, 5250 ft 2 DESIGN OVEVIEW Data Center IT Capacity 200 kw Adaptable from 50 kw to 600 kw Target Availability Tier 3 Annualized UE at 100% Load 1.67 in Miami,

More information

84 kw, Tier 3, Direct Expansion, 937 ft 2

84 kw, Tier 3, Direct Expansion, 937 ft 2 [Reference Design 42] 84 kw, Tier 3, Direct Expansion, 937 ft 2 DESIGN OVERVIEW Data Center IT Capacity 84 kw Target Availability Tier 3 Annualized PUE at 100% Load 1.712 Total Racks and Average Density

More information

2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft.

2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft. [Reference Design 64] 2000 kw, Tier 3, Chilled Water, refabricated, 23700 sq. ft. DESIGN OVERVIEW Data Center IT Capacity 2000 kw Target Availability Tier 3 Annualized E at 100% Load 1.64 in Miami, FL

More information

5.2 MW, Pod-based build, Chilled Water, ft 2

5.2 MW, Pod-based build, Chilled Water, ft 2 [Reference Design 65] 5.2 MW, Pod-based build, hilled Water, 85000 ft 2 DESIGN OVERVIEW Data enter apacity 5.2 MW Target Availability Tier III with 2N power distribution and less-redundant generator configuration

More information

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

3300 kw, Tier 3, Chilled Water, 70,000 ft 2 [Reference Design 22] 3300 kw, Tier 3, Chilled Water, 70,000 ft 2 DESIGN OVERVIEW Data Center IT Capacity 1100 kw per Data Hall 3 Independent Data Halls Design Application Range This design can be applied

More information

9.6 MW, Traditional IT and OCP-compatible, Indirect Air Economizer, m 2

9.6 MW, Traditional IT and OCP-compatible, Indirect Air Economizer, m 2 [Reference esign 62] 9.6 MW, Traditional IT and OC-compatible, Indirect Air Economizer, 16970 m 2 ESIGN OVERVIEW ata Center IT Capacity 9.6 MW Target Availability Tier III with 2N power distribution and

More information

Close-coupled cooling

Close-coupled cooling Close-coupled cooling Intelligently controlled high-performance InRow cooling for the IT environment APC TM by Schneider Electric close-coupled cooling products provide a modular, scalable, and predictable

More information

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America 7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer

More information

QuickSpecs. HP Performance Optimized Datacenter (POD) 20ce. Overview. Retired

QuickSpecs. HP Performance Optimized Datacenter (POD) 20ce. Overview. Retired Overview The HP Performance-Optimized Data Center (HP POD) is a containerized datacenter equipped with power infrastructure, cooling and IT power distribution. The HP POD can be deployed within weeks instead

More information

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling Jeremiah Stikeleather Applications Engineer Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling While CRAH cooling has been

More information

Reference Design Quicktour Design Summary

Reference Design Quicktour Design Summary Quicktour Design Summary Outdoor Heat Rejection Mixed Use or Purpose Built Data Center Facility Indoor/Outdoor Power Generation Mechanical Room Electrical Room Data Center Whitespace Reclaimed Whitespace

More information

Efficiency of Data Center cooling

Efficiency of Data Center cooling Efficiency of Data Center cooling Comparison of data room layouts and cooling systems Bohumil Cimbal Product manager for Cooling Systems in CONTEG Company Objective Basic questions between investor and

More information

Symmetra PX 48kW. Scalable from 16 to 48kW. Make the most of your energy TM. Modular, Scalable, High-Efficiency Power Protection for Data Centers

Symmetra PX 48kW. Scalable from 16 to 48kW. Make the most of your energy TM. Modular, Scalable, High-Efficiency Power Protection for Data Centers Symmetra PX 48kW Scalable from 16 to 48kW Modular, Scalable, High-Efficiency Power Protection for Data Centers High performance, right-sized, modular, scalable, 3-phase power protection with high efficiency

More information

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System A Data Center Heat Removal System That Saves... Infrastructure Power Water up to 40% up to 80% up to 85% Discover Inertech s Award-winning Data Center Heat Removal System A Cool Solution; A Breakthrough

More information

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc. Cooling on Demand - scalable and smart cooling solutions Marcus Edwards B.Sc. Schroff UK Limited Data Centre cooling what a waste of money! A 1MW data center needs 177,000,000 kwh in its lifetime of 10

More information

Modular, scalable, high-efficiency power protection for data centers

Modular, scalable, high-efficiency power protection for data centers Scalable from 16 kw to 160 kw Modular, scalable, high-efficiency power protection for data centers The right-sized UPS for demanding business-critical applications The Schneider Electric Symmetra PX 96/160

More information

Power and Cooling for Ultra-High Density Racks and Blade Servers

Power and Cooling for Ultra-High Density Racks and Blade Servers Power and Cooling for Ultra-High Density Racks and Blade Servers APC White Paper #46 Richard L. Sawyer Director of Data Center Technology American Power Conversion Company 2005 APC corporation What has

More information

Virtualization and consolidation

Virtualization and consolidation Virtualization and consolidation Choosing a density strategy Implementing a high-density environment Maximizing the efficiency benefit Anticipating the dynamic data center Schneider Electric 1 Topical

More information

APC by Schneider Electric Elite Data Centre Partner

APC by Schneider Electric Elite Data Centre Partner Data Centre Solutions...energy efficient by design APC by Schneider Electric Elite Data Centre Partner APC s leading Elite Data Centre Solutions Partner providing customers with expert advice, integration

More information

Thermal management. Thermal management

Thermal management. Thermal management Thermal management Thermal management Managing thermal loads is a major challenge for all Data Centre operators. Effecting proper control of the thermal environment drives energy consumption and ultimately

More information

Integralna rešenja Infrastrukture Data Centra

Integralna rešenja Infrastrukture Data Centra 1 2 Integralna rešenja Infrastrukture Data Centra Jason Dodier, Solutions Business Development Manager - Global Sales (Schneider Electric) Overview of Prefabricated DC's market Prefab - needs to be satisfied

More information

Datacentre Reading East 2 Data sheet

Datacentre Reading East 2 Data sheet Datacentre Reading East 2 Data sheet Data sheet Datacentre Reading East 2 Find us With 10 datacentres, over 4,500 racks and a 10Gb resilient core network between our datacentre locations, Pulsant has the

More information

Optimize Your Data Center. Gary Hill VP, Business Development DVL Group, Inc.

Optimize Your Data Center. Gary Hill VP, Business Development DVL Group, Inc. Optimize Your Data Center Gary Hill VP, Business Development DVL Group, Inc. Data Center Age Profile Gartner Group Survey Legacy Data Centers Challenges Under Powered - Room or Racks Inadequate Air Delivery

More information

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS Cooling > Highly efficient cooling products for any IT application. DATA CENTER SOLUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com End-to-End Cooling Solutions from the Closet to the Data

More information

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA Smart Data Centres Robert M Pe, Data Centre Consultant Services SEA 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice Content Data center

More information

Rack Colocation Hosting. Data Centre Solutions Expertly Engineered

Rack Colocation Hosting.   Data Centre Solutions Expertly Engineered Rack Colocation Hosting www.workspace-technology.com Data Centre Solutions Expertly Engineered We are committed to ensuring the very best data centre environment for your business Rack Colocation Hosting

More information

Modular data centres in containers

Modular data centres in containers Modular data centres in containers 2 Modular data centres Contents IT Containers based on the modular principle.. 4 5 Edge Data Center... 6 7 RiMatrix Data Center Container IT Containers 50 100 kw... 10

More information

The Evolving Data Center

The Evolving Data Center The Evolving Data Center Dominic Loh Product Manager, Power Quality, APAC Data Centers are enabling global growth Proliferation of mobile computing Digitalization of everything Big Data 2 Evolution of

More information

Green Data Centers A Guideline

Green Data Centers A Guideline Green Data Centers A Guideline Sekhar Kondepudi Ph.D Associate Professor Smart Buildings & Smart Cities Vice Chair Focus Group on Smart Sustainable Cities ITU-TRCSL Workshop on Greening the Future: Bridging

More information

DCIM Solutions to improve planning and reduce operational cost across IT & Facilities

DCIM Solutions to improve planning and reduce operational cost across IT & Facilities DCIM Solutions to improve planning and reduce operational cost across IT & Facilities Presented by: Chi Sen, Director, Data Centre Software Solutions, APJ & EMEA Schneider Electric Data Center Solutions

More information

APC APPLICATION NOTE #74

APC APPLICATION NOTE #74 #74 Configuration of InfraStruXure for Data Centers to Support Dell PowerEdge 1855 Abstract Many companies are making plans to incorporate Dell PowerEdge Blade Servers into their data center applications.

More information

SmartMod Intelligent, Integrated Infrastructure for the Data Center

SmartMod Intelligent, Integrated Infrastructure for the Data Center SmartMod Intelligent, Integrated Infrastructure for the Data Center Deploy a High-Capacity, Efficient and Secure Infrastructure in Just Months Building a new data center in a short timeframe is nearly

More information

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect of Record: SPARCH Project Overview The project is located

More information

Driving Business Value through Enterprise Agreements and Partnering

Driving Business Value through Enterprise Agreements and Partnering Driving Business Value through Enterprise Agreements and Partnering Presented by Dwayne Presenter Kalma Name/s and Tyler Duncan Agenda Introductions The Partnership Team: ebay, Dell, and OSIsoft Background

More information

Business continuity made easy

Business continuity made easy Business continuity made easy Schneider Electric Easy UPS 3 Series Easy UPS 3S: 220/230/240/380/400/415V Easy UPS 3M: 380/400/415V schneider-electric.com/ups Business continuity made easy The Schneider

More information

SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER

SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER Enabling Tomorrow s CRITICAL EDGE INFRASTRUCTURE We helped some of the largest names in the industry bring new capacity online

More information

Bus Way vs. Cable: a CapEx comparison

Bus Way vs. Cable: a CapEx comparison Siemens.com/datacenters Bus Way vs. Cable: a CapEx comparison Positive economics characterize bus way based designs for Data Center critical power distribution White Paper November 2013 Traditionally,

More information

Datacentre Newbridge Data sheet

Datacentre Newbridge Data sheet Datacentre Newbridge Data sheet Data sheet Datacentre Newbridge Find us 7 Claylands Road Edinburgh EH28 8LF Scotland With 10 datacentres, over 4,500 racks and a 10Gb resilient core network between our

More information

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power Future of Cooling High Density Equipment Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power Agenda Issues facing the Data Center Managing the explosive

More information

APC InfraStruXure Solution Overview

APC InfraStruXure Solution Overview APC InfraStruXure Solution Overview We re waiting for your call or email. 800--0 uptime@uptimeu.com Wiring Closets ( Racks) Small Server Rooms ( Racks) Small Data Centers ( 0 Racks) Medium Data Centers

More information

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center Deploy a Fully Configured Data Center in Just Weeks Availability, Capacity, Efficiency. You need them and now you can have them

More information

EDGE LM XLMA Series Data Module

EDGE LM XLMA Series Data Module TM TM EDGE LM XLMA Series Data Module The EDGE LM Data Modules can be deployed indoors or outdoors and have been designed to provide density and rack adaptable IT space for environments enabling low to

More information

Cisco Lab Setpoint Increase. Energy Efficient Data Center Demonstration Project

Cisco Lab Setpoint Increase. Energy Efficient Data Center Demonstration Project Cisco Lab Setpoint Increase Energy Efficient Data Center Demonstration Project About the Energy Efficient Data Center Demonstration Project The project s goal is to identify key technology, policy and

More information

T66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management

T66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management T66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management Name Doug Demian Title Application Engineer Date November 7 & 8, 2012 Rev 5058-CO900C Copyright 2012 Rockwell

More information

Next Generation Cooling

Next Generation Cooling Next Generation Cooling Server Manufacturer Perspective Practical and Cost Effective David Moss Data Center Strategist Dell 1 Why Chip, Row, or Rack? Density? Energy Don t be scared; I don t see 50kW/rack

More information

IXcellerate Moscow One Datacentre - Phase 1 & 2 Overview

IXcellerate Moscow One Datacentre - Phase 1 & 2 Overview Contents 1. Document Purpose... 2 2. Facility Overview... 2 2.1 Technical Space... 2 2.2 Load Density... 2 2.3 Resilience... 2 2.4 Engineering Plant Maintenance & Service Restoration... 3 3. Engineering

More information

Symmetra PX. Symmetra PX 48kW Scalable from 16kW to 48kW. Modular, Scalable, High-Efficiency Power Protection for Data Centers

Symmetra PX. Symmetra PX 48kW Scalable from 16kW to 48kW. Modular, Scalable, High-Efficiency Power Protection for Data Centers Modular, Scalable, High-Efficiency Power Protection for Data Centers Symmetra PX 48kW Scalable from 16kW to 48kW > High Performance, Right-Sized 3-Phase Power Protection with Industry-Leading Efficiency,

More information

Prefabricated Data Center Solutions: Coming of Age

Prefabricated Data Center Solutions: Coming of Age Prefabricated Data Center Solutions: Coming of Age Steven Carlini - Global Data Center Marketing Director April 2014 Schneider Electric 1 Schneider Electric 2 Your ability to compete relies on the design,

More information

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY. INNOVATE DESIGN APPLY By A whole new cooling experience The Motivair ChilledDoor Rack Cooling System targets the critical cooling requirements of today s modern server rack designs. As technology continues

More information

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY. INNOVATE DESIGN APPLY By A whole new cooling experience The Motivair ChilledDoor Rack Cooling System targets the critical cooling requirements of today s modern server rack designs. As technology continues

More information

Data Center Design: Power, Cooling & Management

Data Center Design: Power, Cooling & Management Presents Data Center Design: Power, Cooling & Management The Legacy Data Center Large (oversized) UPS Systems Large Power Distribution Systems N, N+1 UPS topologies Large Free standing Static Switches

More information

Modular, scalable, high-efficiency power protection for data centers

Modular, scalable, high-efficiency power protection for data centers Scalable to 20 kw Modular, scalable, high-efficiency power protection for data centers The Symmetra TM PX 20 kw is a world-class, high-efficiency, ENERGY STAR qualified power protection system designed

More information

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

Increasing Data Center Efficiency by Using Improved High Density Power Distribution Increasing Data Center Efficiency by Using Improved High Density Power Distribution By Neil Rasmussen White Paper #128 Revision 1 Executive Summary A new approach to power distribution for high density

More information

DC Energy, Efficiency Challenges

DC Energy, Efficiency Challenges DC Energy, Efficiency Challenges Choosing a density strategy Implementing a high density environment Maximizing the efficiency benefit Anticipating the dynamic data center Key points on energy usage in

More information

University of Florida Data Center at Eastside Campus: Key Facts

University of Florida Data Center at Eastside Campus: Key Facts University of Florida Data Center at Eastside Campus: Key Facts Design: KlingStubbins Architectural Engineering, Philadelphia, PA Construction: Whiting-Turner; Baltimore, MD Commissioning: Hanson Professional

More information

Datacentre Milton Keynes Data sheet

Datacentre Milton Keynes Data sheet Datacentre Milton Keynes Data sheet Data sheet Datacentre Milton Keynes Find us With 10 datacentres, over 4,500 racks and a 10Gb resilient core network between our datacentre locations, Pulsant has the

More information

Schneider Electric Easy UPS 3S

Schneider Electric Easy UPS 3S Schneider Electric Easy UPS 3S Business continuity made easy 10 40 kva 380/400/415 V schneider-electric.com/ups Business continuity made easy The Schneider Electric Easy UPS 3S is an easy-to-install, easy-to-use,

More information

FACT SHEET: IBM NEW ZEALAND DATA CENTRE

FACT SHEET: IBM NEW ZEALAND DATA CENTRE FACT SHEET: IBM NEW ZEALAND DATA CENTRE IBM and the Data Centre IBM is the largest occupier of data centre space in the world and currently owns or occupies approximately one million square metres globally.

More information

Total Modular Data Centre Solutions

Total Modular Data Centre Solutions Sector Data Centre Total Modular Data Centre Solutions www.airedale.com BRITISH MANUFACTURER ENERGY EFFICIENCY CONTROLS SERVICE TRAINING 01 Standardised Modular Designs to fit your needs Our modular system

More information

Rittal Cooling Solutions A. Tropp

Rittal Cooling Solutions A. Tropp 1 Rittal Cooling Solutions Presented by Adam Tropp 2 Agenda Cooling Strategies Aisle Containment Chimney Solution Airstream Management Rittal Liquid Cooling Packages Data Monitoring 3 Cooling strategies.

More information

Data Center Design: Power, Cooling & Management

Data Center Design: Power, Cooling & Management Presents Data Center Design: Power, Cooling & Management The Legacy Data Center Large (oversized) UPS Systems Large Power Distribution Systems N, N+1, 2N, 2(N+1) UPS topologies Large Free standing

More information

Eaton Open Data Centre Solutions. Kari Koli

Eaton Open Data Centre Solutions. Kari Koli Eaton Open Data Centre Solutions Presenter: Stefan Coote Kari Koli 2008 Eaton Corporation. All rights reserved. Eaton Worldwide Founded in 1911 by J.O. Eaton World Headquarters in Cleveland, Ohio USA Customers

More information

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc Current Data Center Design James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc What is the biggest facility problem in your data center? 35% 30% 25% 20% 15% Series1 10% 5% 0% Excessive heat Insufficient

More information

brightsolid Data Hall 1 Keysource Technical Specifications

brightsolid Data Hall 1 Keysource Technical Specifications brightsolid Data Hall 1 Keysource Technical Specifications Page 1 Introduction A Data Centre is a highly controlled environment that provides IT to external organisations seeking to outsource their requirements

More information

Configurable power distribution

Configurable power distribution Configurable power distribution 60 150 kva The easy-to-deploy for data centers with custom requirements Configured to order, factoryassembled power distribution for IT equipment in any size data center

More information

Pros and Cons of Various DC Distribution Architectures

Pros and Cons of Various DC Distribution Architectures Pros and Cons of Various DC Distribution Architectures Source: Solar Powered Datacenter by Google Randy Malik Power Technology And Qualification IBM RTP Raleigh NC Rick Fishbune Power Technology And Qualification

More information

LANL High Performance Computing Facilities Operations. Rick Rivera and Farhad Banisadr. Facility Data Center Management

LANL High Performance Computing Facilities Operations. Rick Rivera and Farhad Banisadr. Facility Data Center Management Slide-1 LANL High Performance Computing Facilities Operations Rick Rivera and Farhad Banisadr Facility Data Center Management Division Slide-2 Outline Overview - LANL Computer Data Centers Power and Cooling

More information

Chiller Replacement and System Strategy. Colin Berry Account Manager

Chiller Replacement and System Strategy. Colin Berry Account Manager Chiller Replacement and System Strategy Colin Berry Account Manager Current Situation 4 Existing RTAA chillers All units 23 years old Limited service history One unit MUST be replaced immediately One unit

More information

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model Austin Data Center 6Sigma DC CFD Model Keith Ward Keith Ward Data Center Facilities Engineering and Logistics Design Austin Data Center Statistics - Space Original AT&T Designed and

More information

1.0 Executive Summary. 2.0 Available Features & Benefits

1.0 Executive Summary. 2.0 Available Features & Benefits Statement Of Work Energy Management Services Table of Contents 1.0 Executive Summary 2.0 Available Features & Benefits 3.0 Assessment Deliverables Selection 4.0 On Site Assessment Activities 5.0 Exclusions

More information

WIRELESS ENVIRONMENTAL MONITORS

WIRELESS ENVIRONMENTAL MONITORS Packet Powers compact wireless Environmental Monitors makes it easy and affordable to monitor all environmental conditions in your facility. From installation to monitoring in minutes 1 Place wireless

More information

Data Center Trends: How the Customer Drives Industry Advances and Design Development

Data Center Trends: How the Customer Drives Industry Advances and Design Development Bablu Kazi, PE MORRISON HERSHFIELD MISSION CRITICAL Data Center Trends: How the Customer Drives Industry Advances and Design Development What does the Customer Need? Scalability P U E Latest Technology

More information

SMARTMOD Intelligent, Integrated Infrastructure for the Data Center

SMARTMOD Intelligent, Integrated Infrastructure for the Data Center SMARTMOD Intelligent, Integrated Infrastructure for the Data Center SMARTMOD Deploy a High-Capacity, Efficient and Secure Infrastructure in Just Months Building a new data center in a short timeframe is

More information

Google s Green Data Centers: Network POP Case Study

Google s Green Data Centers: Network POP Case Study Google s Green Data Centers: Network POP Case Study Table of Contents Introduction... 2 Best practices: Measuring. performance, optimizing air flow,. and turning up the thermostat... 2...Best Practice

More information

Data Center Infrastructure Management (DCIM) By Jesse Zhuo

Data Center Infrastructure Management (DCIM) By Jesse Zhuo Data Center Infrastructure Management (DCIM) By Jesse Zhuo Agenda The Evolution of DCIM Users Perspectives Management Methodology by Delta DCIM The Evolution of DCIM What is DCIM DCIM is software for Data

More information

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101 Nick Gangemi Regional Sales Manager Data Aire Agenda Exactly what are we talking about ASHRAE TC 9.9 Design best practices

More information

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw IT COOLING CLOSE CONTROL AIR CONDITIONERS CHILLED WATER HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw 3 Versions available Single chilled water coil Double chilled water coil High temperature IT COOLING

More information

STATE DATA CENTER DRAFT PROPOSAL. STATE OF OREGON DATA CENTER 28 October 2016

STATE DATA CENTER DRAFT PROPOSAL. STATE OF OREGON DATA CENTER 28 October 2016 STATE DATA CENTER DRAFT PROPOSAL 1 PROJECT TEAM 2 SERA Architects, Inc George Hager Patrick Sullivan PAE Engineers Dave Williams Doug Nachtrieb Michael Yee JMB Consulting Group Jon Bayles MEETING GOALS

More information

Case Study Leicester City Council

Case Study Leicester City Council Data Centre Solutions...energy efficient by design Case Study Leicester City Council Leicester City Council Deploys New Sub 1.1 PUE3 Data Centre Infrastructure. Designed & Installed by Workspace Technology

More information

A Scalable, Reconfigurable, and Efficient High Density Data Center Power Distribution Architecture

A Scalable, Reconfigurable, and Efficient High Density Data Center Power Distribution Architecture A Scalable, Reconfigurable, and Efficient High Density Data Center Power Distribution White Paper 129 Revision 2 by Neil Rasmussen > Executive summary Significant improvements in efficiency, power density,

More information

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design. Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design. TelecityGroup Kvastvägen 25-29 128 62 Sköndal Stockholm Sweden Tel: +46 (0) 8 799 3800 se.info@telecity.com www.telecitygroup.se

More information

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres Product Brochure DENCO Close Control Units Row-DENCO High Density Cooling for Data Centres Data Centre Cooling Through a history in close control, we have developed a broad and deep understanding of how

More information

Switch to Perfection

Switch to Perfection Switch to Perfection Traditional Data Centre - Temperatures Ideal Air Temperature: 22 C Chilled Water: 7-9 C Heat Load per Rack: Up to 4,5 Chilling & Pump Set The challenge a thermal image Front View of

More information

SmartCabinet Intelligent, Integrated Containment for IT Infrastructure

SmartCabinet Intelligent, Integrated Containment for IT Infrastructure TM SmartCabinet Intelligent, Integrated Containment for IT Infrastructure WE ARE VERTIV Vertiv, formerly Emerson Network Power, designs, builds,and services mission critical technologies that enable vital

More information

Liebert DCW CATALOGUE

Liebert DCW CATALOGUE Liebert DCW CATALOGUE Chilled Water-Based High Density Cooling For The Data Center LIEBERT DCW Flexible Approaches For Energy Efficient Cooling Save up to 70% in cooling energy usage Data center managers

More information

Increasing Data Center Efficiency through Metering and Monitoring Power Usage

Increasing Data Center Efficiency through Metering and Monitoring Power Usage White Paper Intel Information Technology Computer Manufacturing Data Center Efficiency Increasing Data Center Efficiency through Metering and Monitoring Power Usage To increase data center energy efficiency

More information

Schneider Electric Easy UPS 3S

Schneider Electric Easy UPS 3S Schneider Electric Easy UPS 3S Business continuity made easy 10 40 kva 380/400/415 V schneider-electric.com/ups Schneider Electric Easy UPS 3S The Schneider Electric Easy UPS 3S is an easy-to-install,

More information

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

Variable Density, Closed-Loop, Water-Cooled Data Center Solution Variable Density, Closed-Loop, Water-Cooled Data Center Solution Overview Great Lakes Case & Cabinet Co., Inc. has worked with Naissus Thermal Management Solutions, of Toronto, Ontario to develop one of

More information

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary Datacenter Efficiency Trends Cary Roberts Tellme, a Microsoft Subsidiary Power Slashing Tools P3 Kill-A-WATT Measures min, max, and instantaneous voltage and current draw Calculates power (watts), kilowatt

More information

Galaxy VM. Three-phase power protection. Galaxy VM trusted partner for your business continuity

Galaxy VM. Three-phase power protection. Galaxy VM trusted partner for your business continuity Galaxy VM Three-phase power protection Galaxy VM trusted partner for your business continuity Highly efficient, easy-to-deploy, three-phase power protection that seamlessly integrates into the electrical,

More information

International 6SigmaDC User Conference CFD Modeling for Lab Energy Savings DCSTG Lab Temperature Setpoint Increase

International 6SigmaDC User Conference CFD Modeling for Lab Energy Savings DCSTG Lab Temperature Setpoint Increase International 6SigmaDC User Conference CFD Modeling for Lab Energy Savings DCSTG Lab Temperature Setpoint Increase Chris Noland cnoland@cisco.com Vipha Kanakakorn vkanakak@cisco.com 3/4/2010 Goal & Limitations

More information

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions Schneider Electric Cooling Portfolio Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions Data Center Cooling Agenda 1. How to size data center, server rooms, IDF rooms, etc in

More information

Engineered Energy Solutions An Overview. Controls, Automation and Energy Conservation

Engineered Energy Solutions An Overview. Controls, Automation and Energy Conservation Engineered Energy Solutions An Overview Controls, Automation and Energy Conservation Engineered Energy Solutions Independent Control System Integration and Engineering Firm specializing in the energy efficient

More information

Data Center Optimized Controls

Data Center Optimized Controls Data Center Optimized Controls Controls Agenda 30 min. Emerson Control Products icom (Dynamic Thermal Optimization) 20 min. Station Rotation Station 1: Controller Challenge Station 2: Wireless Demo 5 min.

More information

Calculating Total Power Requirements for Data Centers

Calculating Total Power Requirements for Data Centers Calculating Total Power Requirements for Data Centers White Paper 3 Revision 1 by Victor Avelar > Executive summary Part of data center planning and design is to align the power and cooling requirements

More information

1.0 Executive Summary

1.0 Executive Summary Statement of Work - 1 - Power and Cooling Assessment for Data Center Professional Services Service 1.0 Executive Summary Table of Contents 1.0 Executive Summary 2.0 Features & Benefits 3.0 Details of Service

More information

MSYS 4480 AC Systems Winter 2015

MSYS 4480 AC Systems Winter 2015 MSYS 4480 AC Systems Winter 2015 Module 12: DATA CENTERS By Satwinder Singh 14/05/2015 1 Data Centers Data Centers are specialized environments that safeguard your company's most valuable equipment and

More information

Introducing the Heat Wheel to the Data Center

Introducing the Heat Wheel to the Data Center Introducing the Heat Wheel to the Data Center Robert (Dr. Bob) Sullivan, Ph.D. Data Center Infrastructure Specialist KyotoCooling International Critical Facilities Round Table 1 A New Free Cooling Technique

More information

IT Air Conditioning Units

IT Air Conditioning Units IT Air Conditioning Units Modern Flexible Effective Energy Saving CoolTeg Plus and CoolTop overview CoolTeg Plus CW CoolTeg Plus DX CoolTeg Plus XC CoolTop Installation Between IT racks On top of IT rack

More information

Impact of Air Containment Systems

Impact of Air Containment Systems White Paper June 2012 WP-20 Impact of Air Containment Systems Reducing Energy Consumption Introduction: The Importance of Maintaining Data Center Cooling Energy Efficiency Data centers are mission-critical

More information