Bosch Institute Advanced Microscopy Facility Workshops Summer/Autumn 2016

Size: px
Start display at page:

Download "Bosch Institute Advanced Microscopy Facility Workshops Summer/Autumn 2016"

Transcription

1 Bosch Institute Advanced Microscopy Facility Workshops Summer/Autumn 2016 Presented by Dr Louise Cole and Dr Cathy Payne, Advanced Microscopy Facility, Bosch Institute, School of Medical Sciences, The University of Sydney.

2 Microscope Training If you are interested in learning how to use light and fluorescence microscopes, the Bosch Institute Advanced Microscopy Facility (AMF) can offer expert training and support on a range of light and fluorescence microscopes and other specialized imaging methods, including image analysis and processing methods. Summary of Summer/Autumn Workshops 2016 ZEISS AxioScan Slide-Scanning Microscope ZEISS transmitted light, fluorescence, ApoTome.2 and deconvolution Microscope Nuance multi-spectral imaging system Olympus MBF/Stereo Investigator TL Microscope Leica SPEII confocal Microscope ZEISS LSM 510 Meta confocal Microscope PALM Microbeam DuoFlex Combi Laser Microdissection Microscope Light-sheet/Ultramicroscope microscope Cannot find the training workshop you need? For a full list of microscopes, their specifications and related software available at the Bosch AMF please go to: sydney.edu.au/medicine/bosch/facilities/ advanced-microscopy. Training can be offered on one-on-one basis by arrangement with the Microscopy Officer. Cost: In most cases, training workshops are FREE to current registered users of the Bosch Institute Advanced Microscopy Facility. How to register as a user at the Bosch Institute Advanced Microscopy Facility? Current registration forms can be downloaded from the Bosch AMF website: sydney.edu.au/medicine/bosch/facilities/advanced-microscopy/user-support. Fees are listed on this form. If you require training and need to use a number of microscopes at the Bosch AMF, then registering to the AMF is costeffective. Since registration costs cover all access to microscopes and related software and both training and workshops fees. No additional hourly usage fees are charged. Please return completed forms to the Microscopy Officer. All AMF users must be trained by AMF staff on the equipment prior to use. Individual training and workshop fees for non-registered AMF users can be provided on request from the Microscopy Officer.

3 ZEISS AxioScan slide-scanning microscope This microscope has both bright-field and fluorescence imaging capabilities and can create virtual images of whole slides or defined regions of interest. It can hold up to 100 slides at one time and allows high through-put slide-scanning so that you can scan your slides overnight! In this workshop you will learn how to use this microscope independently. Tues Mar 8 th or Weds Mar 9 th am pm. Rm N127, Anderson Stuart Building, F13. Maximum attendees per session, 4. Zeiss transmitted light, fluorescence, ApoTome.2 and deconvolution microscopy workshop This microscope is our most popular wide-field fluorescence microscope. In this workshop you will learn how to set-up for transmitted light, wide-field fluorescence and deconvolution microscopy. Includes ZEN Blue software training. You will also learn how to use the ApoTome.2 for contrast enhancement. Mon Mar 14 th 2.00 pm pm or Thurs Mar 17 th 2.30 pm pm. Rm S443, Anderson Stuart Building, F13. Maximum attendees per session, 5. Nuance multi-spectral imaging system This multi-spectral imaging technology can acquire images at many wavelengths and can therefore better determine fluorophore or stain distribution. It can be used to separate spatially overlapping chromogens and remove autofluorescence from tissues. This microscope has both bright-field and fluorescence imaging capabilities. Mon Mar 21 st 2.00 pm pm. Rm E401, Anderson Stuart Building, F13. Max. attendees per session, 5. Olympus MBF/Stereo Investigator TL Microscope This microscope has a motorised xyz-stage and MBF Stereo Investigator software for design based Stereology, Image Analysis, and 2D Anatomical Mapping. In this workshop, you will learn how to use the Virtual Slice module that automatically creates a montage by collecting a series of contiguous images from a tissue specimen. This software aligns, stitches and blends images into a seamless montage. This microscope is quick and easy to use, is useful for routine bright-field imaging and enables fast navigation to any region of the slide. Thurs Mar 24 th 2.30 pm pm. Rm E401, Anderson Stuart Building, F13. Max. attendees per session, 5.

4 Leica SPEII confocal microscope workshop Upright microscope suitable for imaging fixed and slidemounted specimens. Short workshop on confocal imaging includes multi-colour and z-stack image acquisition. This workshop is popular with beginners to confocal microscopy. Tues Apr 5 th, Weds Apr 6 th or Thurs Apr 7 th am noon. Rm S443, Anderson Stuart Building, F13. Max. attendees per session, 5. ZEISS LSM 510 Meta confocal microscope workshop Short workshop on confocal imaging includes single-, multitrack and z-stack image acquisition. Inverted microscope supports imaging of slide-mounted specimens and single or multi-well culture dishes. This course and microscope is recommended for users with some previous knowledge of fluorescence and/or confocal microscopy. Tues Apr 12 th or Weds Apr 13 th am noon. Rm S443, Anderson Stuart Building, F13. Max. attendees per session, 5. PALM Microbeam DuoFlex Combi Laser Microdissection Microscope workshop Do you want to combine your microscopy with molecular biology tools? This workshop shows you how to laser microdissect selected areas of cells or tissue samples. Dissected samples are catapulted against gravity into collection caps, are contamination-free and ready for further downstream molecular analyses of RNA, DNA and/or protein. Tues Apr 26 th or Weds Apr 27 th am noon. Rm N135, Anderson Stuart Building, F13. Max. attendees per session, 6. Light-sheet microscopy workshop Learn how to use the LaVision BioTec Ultra-microscope II. This microscope generates six focused light sheets to excite samples from the side only and thereby reduce bleaching and photo-toxicity. The emitted fluorescence light is detected perpendicular to the illumination plane. Moving the sample through the light-sheet generates a 3D image stack. The open set-up allows the analysis of cleared samples in any clearing solution or in vivo data acquisition of samples in aqueous media. Perfect for imaging larger cleared samples quickly. Tues May 3 rd or Weds May 4 th am noon. Rm S448, Anderson Stuart Building, F13. Max. attendees per session, 6.

5

6 For workshop registration or any further information, please contact: Dr. Louise Cole Tel. No Dr. Cathy Payne Tel. No CRICOS 0026A

Bosch Institute Advanced Microscopy Facility Workshops Summer/Autumn 2017

Bosch Institute Advanced Microscopy Facility Workshops Summer/Autumn 2017 Bosch Institute Advanced Microscopy Facility Workshops Summer/Autumn 2017 Presented by Dr Louise Cole, Advanced Microscopy Facility, Bosch Institute, School of Medical Sciences, The University of Sydney.

More information

with an incubator for study of live

with an incubator for study of live Light microscopy Support medium is glass. Choose this route for confocal imaging. Do you want to quickly check your cells for green, red or blue fluorescence or using phase contrast? (If so, refer to microscope

More information

Technology Transition Workshop Jack Garner. Carl Zeiss PALM. Technology Transition Workshop

Technology Transition Workshop Jack Garner. Carl Zeiss PALM. Technology Transition Workshop Jack Garner Carl Zeiss PALM Laser Microdissection & Pressure Catapulting (LMPC) New horizons for microgenomics, proteomics and live cell micromanipulation Laser capture microscopy The technology Forensic

More information

COLOCALISATION. Alexia Ferrand. Imaging Core Facility Biozentrum Basel

COLOCALISATION. Alexia Ferrand. Imaging Core Facility Biozentrum Basel COLOCALISATION Alexia Ferrand Imaging Core Facility Biozentrum Basel OUTLINE Introduction How to best prepare your samples for colocalisation How to acquire the images for colocalisation How to analyse

More information

COLOCALISATION. Alexia Loynton-Ferrand. Imaging Core Facility Biozentrum Basel

COLOCALISATION. Alexia Loynton-Ferrand. Imaging Core Facility Biozentrum Basel COLOCALISATION Alexia Loynton-Ferrand Imaging Core Facility Biozentrum Basel OUTLINE Introduction How to best prepare your samples for colocalisation How to acquire the images for colocalisation How to

More information

Spinning Disk Protocol

Spinning Disk Protocol Spinning Disk Protocol 1) System Startup F Please note our sign-up policy You must inform the facility at least 24 hours beforehand if you can t come; otherwise, you will receive a charge for unused time

More information

Basic Users Guide for the LSM 510 Confocal Microscope

Basic Users Guide for the LSM 510 Confocal Microscope Basic Users Guide for the LSM 510 Confocal Microscope Ian Jones and Adam Westmacott Department of Biology & Biochemistry, University of Bath, Bath, UK Updated 01 October 2003 This guide describes the basic

More information

BioImaging facility update: from multi-photon in vivo imaging to highcontent high-throughput image-based screening. Alex Laude The BioImaging Unit

BioImaging facility update: from multi-photon in vivo imaging to highcontent high-throughput image-based screening. Alex Laude The BioImaging Unit BioImaging facility update: from multi-photon in vivo imaging to highcontent high-throughput image-based screening Alex Laude The BioImaging Unit Multi-dimensional, multi-modal imaging at the sub-cellular

More information

Technology and equipment at the Bioimaging Center

Technology and equipment at the Bioimaging Center Technology and equipment at the Bioimaging Center Light microscopy / Widefields Name Type Applications and equipment LEICA AF6000LX Nikon BioStation Timelaps imaging, CO2 and temperature controlled (14

More information

From Eye to Insight. Powerful Upright Microscope Solutions for Life Science and Clinical Applications

From Eye to Insight. Powerful Upright Microscope Solutions for Life Science and Clinical Applications From Eye to Insight Powerful Upright Microscope Solutions for Life Science and Clinical Applications Leica DM4 B Leica DM6 B Short training time, intuitive usage and high quality images are decisive criteria

More information

CFIM MICROSCOPY COURSE TIMETABLE PRINCIPLES OF MICROSCOPY MONDAY 6 TH OF JANUARY 2014 FRIDAY 10 TH OF JANUARY 2014

CFIM MICROSCOPY COURSE TIMETABLE PRINCIPLES OF MICROSCOPY MONDAY 6 TH OF JANUARY 2014 FRIDAY 10 TH OF JANUARY 2014 MICROSCOPY COURSE TIMETABLE PRINCIPLES OF MICROSCOPY MONDAY 6 TH OF JANUARY 2014 FRIDAY 10 TH OF JANUARY 2014 CONFOCAL AND FLUORESCENCE MICROSCOPY MONDAY 20 TH OF JANUARY 2014 FRIDAY 24 TH OF JANUARY 2014

More information

TissueFAXS SL Confocal high throughput configuration (actual appearance of the product may differ)

TissueFAXS SL Confocal high throughput configuration (actual appearance of the product may differ) TISSUEFAXS CONFOCAL TissueFAXS SL Confocal high throughput configuration (actual appearance of the product may differ) TissueFAXS Confocal provides a unique combination of digital slide scanning and laser

More information

ONBI Practical 7: Comparison of techniques

ONBI Practical 7: Comparison of techniques ONBI Practical 7: Comparison of techniques RM Parton 2014 Aims of practical 7: One of the most common issues confronting people new to microscopy is the confusing array of different techniques available.

More information

OIC. User Guide to Confocal Microscope: Zeiss LSM Pascal

OIC. User Guide to Confocal Microscope: Zeiss LSM Pascal User Guide to Confocal Microscope: Zeiss LSM Pascal This guide does not cover all the details in documentation that comes with the Zeiss micro-scope. Please do find time to go through the original documentation

More information

InVivo Analyzer Suite

InVivo Analyzer Suite InVivo Analyzer Suite Live Cell Imaging Software for Fast Acquisition and Complete Analysis The Complete Live Cell Imaging Solution Events happen fast in live cell experimentation. InVivo InVivo Analyzer

More information

Leica Microsystems Intelligent Structured Illumination Microscopy

Leica Microsystems Intelligent Structured Illumination Microscopy Widefield Mouse kidney section. Maximum projection of a stack containing 65 planes. Green: glomeruli and convoluted tubules (wheat germ agglutinin Alexa Fluor 488) Blue: Nuclei (DAPI). Structured Illumination

More information

New Olympus FV3000RS Laser Scanning Confocal System. Quotation Number V2

New Olympus FV3000RS Laser Scanning Confocal System. Quotation Number V2 New Olympus FV3000RS Laser Scanning Confocal System Quotation Number 00056013 V2 Quotation Date: 08/08/2018 Revised Date: 07/09/2018 Quotation number: 00056013 Quotation Expiry: 07/11/2018 Macquarie University

More information

BioTech 35: Immunofluorescence & Confocal Microscopy NIH Bldg. 162

BioTech 35: Immunofluorescence & Confocal Microscopy NIH Bldg. 162 NIH Bldg. 162 Tuesday 8:40am 8:45am Welcome Jithesh Veetil (FAES) 8:45am 10:00am Fundamentals of Fluorescence Microscopy Scott Olenych (Zeiss) 10:00am 10:10am 10:10am 11:30am Intro to Immunofluorescence,

More information

Lighthouse Core Facility Lighthouse Update

Lighthouse Core Facility Lighthouse Update Lighthouse Core Facility Lighthouse Update Marie Follo, Ph.D. Cell Sorters BD FACSAria III / BD FACSAria Fusion Sort speeds over 20,000 total events/sec. 4-way sorting Cell / well cloning (up to 96 wells)

More information

Manual ANGSTROM grid confocal microscope

Manual ANGSTROM grid confocal microscope Manual ANGSTROM grid confocal microscope Switching on the system 1) Start by switching on the different components of the microscope system. When using live cell imaging also start the temperature and

More information

Nikon T1-E microscope with A1 confocal and STORM super-resolution Zeiss LSM510/Meta confocal microscope.

Nikon T1-E microscope with A1 confocal and STORM super-resolution Zeiss LSM510/Meta confocal microscope. Nikon T1-E microscope with A1 confocal and STORM super-resolution. This system allows for the imaging of cells and tissues labeled with fluorescent probes using live or fixed specimens to obtain 3D images

More information

Principles of Light Microscopy

Principles of Light Microscopy Monday 8 August 2011 Principles of Light Microscopy 09:00 09:30 Introduction 09:30 10:15 The story of the microscope / 10:15 Coffee 10:30 12:45 Limitations of the eye. Resolution, contrast, magnification.

More information

LSM510 Confocal Microscope Standard Operation Protocol Basic Operation

LSM510 Confocal Microscope Standard Operation Protocol Basic Operation LSM510 Confocal Microscope Standard Operation Protocol Basic Operation Please make sure that the COMPRESSED AIR has been TURNED ON prior to the use of the equipment. Kindly inform the administrator if

More information

Olympus IX-70 Imaging Protocol

Olympus IX-70 Imaging Protocol Olympus IX-70 Imaging Protocol 1) System Startup F Please note our sign-up policy. You must inform the facility at least 24 hours beforehand if you can t come; otherwise, you will receive a charge for

More information

Confocal Application Notes April 2010

Confocal Application Notes April 2010 April 2010 Motorized Stage Applications Mark & Find Prepared by Louise Bertrand Applications and Technical Support Group, Leica Microsystems, Inc In this issue of Leica Confocal Application Notes, we describe

More information

Look Ahead to Get Ahead

Look Ahead to Get Ahead Microscopy from Carl Zeiss Archive 3D Deconvolution Z-stack 3D Deconvolution Look Ahead to Get Ahead Mark & Find Multichannel Timelapse Greater brilliance and resolution More convenient and precise than

More information

picoemerald Tunable Two-Color ps Light Source Microscopy & Spectroscopy CARS SRS

picoemerald Tunable Two-Color ps Light Source Microscopy & Spectroscopy CARS SRS picoemerald Tunable Two-Color ps Light Source Microscopy & Spectroscopy CARS SRS 1 picoemerald Two Colors in One Box Microscopy and Spectroscopy with a Tunable Two-Color Source CARS and SRS microscopy

More information

Olympus IX-70 Imaging Protocol

Olympus IX-70 Imaging Protocol Olympus IX-70 Imaging Protocol 1) System Startup Please note our sign-up policy. You must inform the facility at least 24 hours beforehand if you can t come; otherwise, you will receive a charge for unused

More information

1. Editorial. N 10 February Content

1. Editorial. N 10 February Content N 10 February 2012 Content 1. Editorial 2. In vivo micro CT Imaging Technology Available at CIF Epalinges 3. Zeiss LSM 700 Confocal Microscope at CIF Dorigny 4. New Powerful Image Processing Setups 5.

More information

ZEISS Smartproof 5 Your Integrated Widefield Confocal Microscope for Surface Analysis in Quality Assurance and Quality Control

ZEISS Smartproof 5 Your Integrated Widefield Confocal Microscope for Surface Analysis in Quality Assurance and Quality Control Product Information Version 1.0 ZEISS Smartproof 5 Your Integrated Widefield Confocal Microscope for Surface Analysis in Quality Assurance and Quality Control Dedicated Design. Guided Workflow. Trusted

More information

THE VERTICAL TURN. Leica TCS SP8 DLS Confocal and Digital LightSheet Microscope

THE VERTICAL TURN. Leica TCS SP8 DLS Confocal and Digital LightSheet Microscope THE VERTICAL TURN Leica TCS SP8 DLS Confocal and Digital LightSheet Microscope Color coded three-dimensional image of eye specific GFP expression (3P3 promoter) in Drosophila melanogaster. Specimen courtesy

More information

LIGHT SHEET MICROSCOPE. Alphα NEW GENERATION. Ground Breaking Technology For Selective Plane Illumination Microscopy

LIGHT SHEET MICROSCOPE. Alphα NEW GENERATION. Ground Breaking Technology For Selective Plane Illumination Microscopy LIGHT SHEET MICROSCOPE NEW GENERATION 3 Alphα Ground Breaking Technology For Selective Plane Illumination Microscopy Alphα 3 GET THE MOST OUT OF LIGHT SHEET IMAGING Optimal SPIM Architecture SHARP OPTICAL

More information

Renishaw invia Raman Microscope (April 2006)

Renishaw invia Raman Microscope (April 2006) Renishaw invia Raman Microscope (April 2006) I. Starting the System 1. The main system unit is ON all the time. 2. Switch on the Leica microscope and light source for reflective bright field (BF) imaging.

More information

EPFL SV PTBIOP BIOP COURSE 2015 OPTICAL SLICING METHODS

EPFL SV PTBIOP BIOP COURSE 2015 OPTICAL SLICING METHODS BIOP COURSE 2015 OPTICAL SLICING METHODS OPTICAL SLICING METHODS Scanning Methods Wide field Methods Point Scanning Deconvolution Line Scanning Multiple Beam Scanning Single Photon Multiple Photon Total

More information

MonoVista CRS+ Raman Microscopes

MonoVista CRS+ Raman Microscopes MonoVista CRS+ Benefits Deep UV to NIR wavelength range Up to 4 integrated multi-line lasers plus port for large external lasers Dual beam path for UV and VIS/NIR Motorized Laser selection Auto Alignment

More information

User s Guide to the LMD Laser Micro-dissection. System

User s Guide to the LMD Laser Micro-dissection. System User s Guide to the LMD-6000 Laser Micro-dissection System Page 1 Glen MacDonald October 31, 2018 Start-up Procedure for Leica LMD-6000. 1. Turn on mercury lamp by pressing the rocker switch; a. beige

More information

Presentation and analysis of multidimensional data sets

Presentation and analysis of multidimensional data sets Presentation and analysis of multidimensional data sets Overview 1. 3D data visualisation Multidimensional images Data pre-processing Visualisation methods Multidimensional images wavelength time 3D image

More information

From Eye to Insight. Leica DMC2900. Digital microscope camera for easy, efficient documentation and presentation in industry and research

From Eye to Insight. Leica DMC2900. Digital microscope camera for easy, efficient documentation and presentation in industry and research From Eye to Insight Leica DMC2900 Digital microscope camera for easy, efficient documentation and presentation in industry and research 3 High Speed Imaging Leica DMC2900 with USB 3.0 interface for highest

More information

Samples Carolina sample slides (pollen, algae, ). Clean off oil with lens paper then OpticPad around lens (metal not glass) when done.

Samples Carolina sample slides (pollen, algae, ). Clean off oil with lens paper then OpticPad around lens (metal not glass) when done. Bi/BE 227 Winter 2018 Assignment #1 Widefield and confocal laser scanning microscopy Schedule: Jan 3: Lecture Jan 3-12: Students get trained on how to use scopes, start on assignment Jan 3-17: Carrying

More information

Confocal vs. Deconvolution

Confocal vs. Deconvolution Confocal vs. Deconvolution Cesare Covino ALEMBIC Advanced Light and Electron Bio-Imaging Center Istituto Scientifico San Raffaele (Milano) www.hsr.it/research/alembic Fluorescence high contrast high sensibility

More information

Laser Capture Microdissection, Methods for Microgenomic Analysis. Location: FAES BioTech One Cloister Ct., Building 60, RM 60, Bethesda MD, 20814

Laser Capture Microdissection, Methods for Microgenomic Analysis. Location: FAES BioTech One Cloister Ct., Building 60, RM 60, Bethesda MD, 20814 Agenda Laser Capture Microdissection, s for Microgenomic Analysis Location: FAES BioTech One Cloister Ct., Building 60, RM 60, Bethesda MD, 20814 Monday Welcome and Introductions Introduction to Laser

More information

IMAGING PLATFORMS IN THE FACULTY OF MEDICINE. Guo Jing Lab Manager Faculty Core Facilty June

IMAGING PLATFORMS IN THE FACULTY OF MEDICINE. Guo Jing Lab Manager Faculty Core Facilty June IMAGING PLATFORMS IN THE FACULTY OF MEDICINE Guo Jing Lab Manager Faculty Core Facilty June 27 2011 http://www.med.hku.hk/corefac/ Mission Training and education Basic operation Advanced application Imaging

More information

Non-Descanned FLIM Systems for Olympus FV-1000 and FV-300 Multiphoton Microscopes

Non-Descanned FLIM Systems for Olympus FV-1000 and FV-300 Multiphoton Microscopes Non-Descanned FLIM Systems for Olympus FV-1000 and FV-300 Multiphoton Microscopes Abstract. Recently multiphoton versions of the Olympus FV 1000 and FV 300 laser scanning microscopes have become available.

More information

LSM 5 MP, LSM 510 and LSM 510 META Laser Scanning Microscopes

LSM 5 MP, LSM 510 and LSM 510 META Laser Scanning Microscopes LSM 5 MP, LSM 510 and LSM 510 META Laser Scanning Microscopes Brief Operating Manual Release 4.2 January 2007 Contents Page Starting the System...3 Setting the microscope...6 Configuring the beam path

More information

DSU Start-Up instructions

DSU Start-Up instructions DSU Start-Up instructions Always: - start with the 10x objective - properly center the stage around the current objective before changing to another objective - when done, leave the 10x objective in standby

More information

Zeiss Efficient Navigation (ZEN) Blue Edition Standard Operation Protocol

Zeiss Efficient Navigation (ZEN) Blue Edition Standard Operation Protocol Faculty Core Facility ZEN BLUE 2.3 SOP A-1 Zeiss Efficient Navigation (ZEN) Blue Edition Standard Operation Protocol Faculty Core Facility ZEN BLUE 2.3 SOP A-2 A. Content Overview. 3 Start up. 4 Display

More information

Zeiss Elyra Microscope Standard Operation Protocol Basic Operation

Zeiss Elyra Microscope Standard Operation Protocol Basic Operation Machine Startup Zeiss Elyra Microscope Standard Operation Protocol Basic Operation 1. Turn on the Incubator power to warm up the incubator for a couple of hours prior to sample acquisition as image could

More information

DeltaVision OMX SR super-resolution microscope. Super-resolution doesn t need to be complicated

DeltaVision OMX SR super-resolution microscope. Super-resolution doesn t need to be complicated DeltaVision OMX SR super-resolution microscope Super-resolution doesn t need to be complicated Live-cell super-resolution microscopy DeltaVision OMX SR is a compact super-resolution microscope system optimized

More information

1. Getting Started: Brief Step-By-Step Guide (PDF File)

1. Getting Started: Brief Step-By-Step Guide (PDF File) Page 1 of 5 1. Getting Started: Brief Step-By-Step Guide (PDF File) Leica SP2 confocal microscope is controlled via software LCS (Leica Confocal Software). The latest version is V2.5. Bellowing is a brief

More information

Mightex Simply Brighter. Polygon400 Multiwavelength Dynamic Spatial Illuminators (Part Numbers: DSI-x-xxxx-xxxx-xxx-xxx) PRODUCT DESCRIPTION FEATURES

Mightex Simply Brighter. Polygon400 Multiwavelength Dynamic Spatial Illuminators (Part Numbers: DSI-x-xxxx-xxxx-xxx-xxx) PRODUCT DESCRIPTION FEATURES FEATURES Programmable image patterns Up to 4,000 frames per second 416K pixel DLP panel Wide range of available wavelengths Support LEDs or arc lamps Diffraction-limited projection High-throughput Etenduepreserving

More information

Independent Resolution Test of

Independent Resolution Test of Independent Resolution Test of as conducted and published by Dr. Adam Puche, PhD University of Maryland June 2005 as presented by (formerly Thales Optem Inc.) www.qioptiqimaging.com Independent Resolution

More information

The Paper Project Guide to Confocal Imaging at Home & in the Classroom

The Paper Project Guide to Confocal Imaging at Home & in the Classroom The Paper Project Guide to Confocal Imaging at Home & in the Classroom http://lifesciences.asu.edu/paperproject The Paper Project Guide to Confocal Imaging at Home & in the Classroom CJ Kazilek & Dennis

More information

Zeiss Universal SIM. A structured illumination system based on a Zeiss Universal microscope stand. by Nidhogg

Zeiss Universal SIM. A structured illumination system based on a Zeiss Universal microscope stand. by Nidhogg Zeiss Universal SIM A structured illumination system based on a Zeiss Universal microscope stand. by Nidhogg Structured illumination Structured illumination applied to fluorescence microscopy is a super

More information

Microscopy Specs. Media refractive index

Microscopy Specs. Media refractive index Zeiss AxioImager A2 EC Plan-Neofluar (420320-9901-000000) EC Plan-Neofluar (420330-9901-000000) Plan-Apochromat (420640-9900-000000) Plan-Apochromat (420650-9901-000000) Plan-Apochromat Korr (420660-9970-000)

More information

Leica TCS SPE. Simply Sophisticated Your Personal Confocal

Leica TCS SPE. Simply Sophisticated Your Personal Confocal Leica TCS SPE Simply Sophisticated Your Personal Confocal 3 Leica TCS SPE Simply Sophisticated Many exciting discoveries begin with a confocal from Leica Microsystems. Here is one to start with the Leica

More information

AUTOFOCUS SENSORS & MICROSCOPY AUTOMATION IR LASER SCANNING CONFOCAL MICROSCOPE IRLC DEEP SEE. Now See Deeper than ever before

AUTOFOCUS SENSORS & MICROSCOPY AUTOMATION IR LASER SCANNING CONFOCAL MICROSCOPE IRLC DEEP SEE. Now See Deeper than ever before AUTOFOCUS SENSORS & MICROSCOPY AUTOMATION IR LASER SCANNING CONFOCAL MICROSCOPE IRLC DEEP SEE Now See Deeper than ever before Review and inspection of non visible subsurface defects Non visible and subsurface

More information

Using Virtual Slides in Medical Education with the Virtual Slice System. Jack Glaser, President MicroBrightField, Inc.

Using Virtual Slides in Medical Education with the Virtual Slice System. Jack Glaser, President MicroBrightField, Inc. Using Virtual Slides in Medical Education with the Virtual Slice System Jack Glaser, President MicroBrightField, Inc. Advantages of Virtual Slides Overview 0.08x Single section 0.63x Entire 2 x3 inch

More information

Zeiss LSM 510 Meta inverted confocal manual

Zeiss LSM 510 Meta inverted confocal manual Power Up Zeiss LSM 510 Meta inverted confocal manual *adapted from the Duke University Light Microscopy Core Facility manual 1. Turn on the mercury lamp (if required) and sign in the log book, recording

More information

Dragonfly. High Speed Confocal Imaging Platform

Dragonfly. High Speed Confocal Imaging Platform Dragonfly High Speed Confocal Imaging Platform The Dragonfly confocal enabled us to capture larger images at twice the resolution in the same time a conventional confocal would capture a regular 512 x

More information

SPECTRUM. The world s first fully automated Raman AFM. AFM - confocal Raman - SNOM - TERS AFM KPFM. Raman. AFM-Raman characterization of PS-PVAC

SPECTRUM. The world s first fully automated Raman AFM. AFM - confocal Raman - SNOM - TERS AFM KPFM. Raman. AFM-Raman characterization of PS-PVAC Raman KPFM AFM AFM-Raman characterization of PS-PVAC polymer blend film SPECTRUM The world s first fully automated Raman AFM AFM - confocal Raman - SNOM - TERS The first fully integrated & automated AFM

More information

Zeiss AxioImager.Z2 Fluorescence Protocol

Zeiss AxioImager.Z2 Fluorescence Protocol Zeiss AxioImager.Z2 Fluorescence Protocol 1) System Startup Please note put sign-up policy. You must inform the facility at least 24 hours beforehand if you can t come; otherwise, you will receive a charge

More information

All-In-One. digital inverted microscope. High-quality Imaging Has Never Been Easier. evos-ca.com

All-In-One. digital inverted microscope. High-quality Imaging Has Never Been Easier. evos-ca.com All-In-One digital inverted microscope High-quality Imaging Has Never Been Easier evos-ca.com Fluorescence Imaging Is Now Easier Than Ever ALL-IN-ONE, digital inverted fluorescence microscope The easiest

More information

Chemical Characterization of Diverse Pharmaceutical Samples by Confocal Raman Microscopy

Chemical Characterization of Diverse Pharmaceutical Samples by Confocal Raman Microscopy Whitepaper Chemical Characterization of Diverse Pharmaceutical Samples by Confocal Raman Microscopy WITec GmbH, Lise-Meitner-Str. 6, 89081 Ulm, Germany, www.witec.de Introduction The development and production

More information

Lightsheet Z.1. Light Sheet Fluorescence Microscopy by Carl Zeiss. Fabrice Schmitt, Sales Manager Carl ZEISS France

Lightsheet Z.1. Light Sheet Fluorescence Microscopy by Carl Zeiss. Fabrice Schmitt, Sales Manager Carl ZEISS France Lightsheet Z.1 Light Sheet Fluorescence Microscopy by Carl Zeiss Fabrice Schmitt, Sales Manager Carl ZEISS France 12.12.2012 Light Sheet Fluorescence Microscopy (LSFM) Principle The Principle of Light

More information

NDD FLIM Systems for Leica SP2 MP and SP5 MP Multiphoton Microscopes

NDD FLIM Systems for Leica SP2 MP and SP5 MP Multiphoton Microscopes NDD FLIM Systems for Leica SP2 MP and SP5 MP Multiphoton Microscopes bh FLIM systems for the confocal and the multiphoton versions of the Leica SP2 and SP5 microscopes are available since 2002 [4]. These

More information

Save Investments: Reliable microscopic results and expert consultancy. A comprehensive offering for bio- medical and industrial applications

Save Investments: Reliable microscopic results and expert consultancy. A comprehensive offering for bio- medical and industrial applications Hund Microscopy Save Investments: Reliable microscopic results and expert consultancy A comprehensive offering for bio- medical and industrial applications Helmut Hund GmbH Artur Herzog Str. 2 D 35580

More information

MAT 17C - DISCUSSION #4, Counting Proteins

MAT 17C - DISCUSSION #4, Counting Proteins MAT 17C - DISCUSSION #4, Counting Proteins Visualization of molecules inside a living cell is one of the most important tools of molecular biology in the 21 st century. In fact, it was the subject of the

More information

CVR Microscope Booking Instructions

CVR Microscope Booking Instructions CVR Microscope Booking Instructions 1. Register to book at http://iii-bookings.org/register.php 2. Email me (colin.loney@glasgow.ac.uk) to let me know which of the following instruments you wish to access.

More information

ZEISS Microscopy From micro to nano your partner for innovative microscopy solutions

ZEISS Microscopy From micro to nano your partner for innovative microscopy solutions ZEISS Microscopy From micro to nano your partner for innovative microscopy solutions Our product portfolio for the industry Spring promotion -16% discount on all microscopes and accessories for orders

More information

PInano 1x3 XYZ & XY Piezo Stage Systems

PInano 1x3 XYZ & XY Piezo Stage Systems New: Large Aperture for Slides, Petri Dishes, Heaters & Specimen Holders PInano 1x3 XYZ & XY Piezo Stage Systems Low-Profile, Low-Cost, Nanopositioning Systems for Super-Resolution Microscopy PInano series

More information

Product Information Version 2.0. ZEISS Shuttle & Find Bridge the Micro and Nano World in Materials Inspection and Analysis

Product Information Version 2.0. ZEISS Shuttle & Find Bridge the Micro and Nano World in Materials Inspection and Analysis Product Information Version 2.0 ZEISS Shuttle & Find Bridge the Micro and Nano World in Materials Inspection and Analysis Bridge the Micro and Nano World in Materials Inspection and Analysis Enhance Productivity

More information

SENSITIVITY DIFFERENTLY TO SEE THINGS THE SPEED AND. Opera Phenix High Content Screening System

SENSITIVITY DIFFERENTLY TO SEE THINGS THE SPEED AND. Opera Phenix High Content Screening System THE SPEED AND SENSITIVITY TO SEE THINGS DIFFERENTLY Opera Phenix High Content Screening System For research use only. Not for use in diagnostic procedures. HIGH CONTENT SCREENING WITHOUT THE COMPROMISE

More information

FY10 Policy for Use of the LSM510META Live-Cell Confocal Laser System

FY10 Policy for Use of the LSM510META Live-Cell Confocal Laser System FY10 Policy for Use of the LSM510META Live-Cell Confocal Laser System 1. Faculty, staff, postdoctoral fellows, and students who wish to use the Zeiss LSM510- META Live-Cell confocal laser system in the

More information

Introductory Guide to Light Microscopy - Biomedical Confocal Microscopy

Introductory Guide to Light Microscopy - Biomedical Confocal Microscopy Introductory Guide to Light Microscopy - Biomedical Confocal Microscopy 7 May 2007 Michael Hooker Microscopy Facility Michael Chua microscopy@unc.edu 843-3268 6007 Thurston Bowles Wendy Salmon wendy_salmon@med.unc.edu

More information

Leica LMD6500 Laser Microdissection Easy to Use, Fast, Precise, Versatile, Effective

Leica LMD6500 Laser Microdissection Easy to Use, Fast, Precise, Versatile, Effective Bob Fasulka Leica LMD6500 Laser Microdissection Easy to Use, Fast, Precise, Versatile, Effective Latest LM The Leica LMD6500 represents one of the latest laser microdissection technologies Molecular and

More information

Fast, reliable and automatic 3D alignment of confocal image stacks: Practical

Fast, reliable and automatic 3D alignment of confocal image stacks: Practical Fast, reliable and automatic 3D alignment of confocal image stacks: Practical Dept. of Infection Biology, Biozentrum, University of Basel mario@xuvtools.org 30.04.2010 Overview Motivation Existing Commercial

More information

Bulletin 80C01C01-01E

Bulletin 80C01C01-01E Bulletin 80C01C01-01E *1 *2 The CSU-X1 is the advanced model of our CSU-series, which are widely recognized as the most powerful tools for live cell imaging. Faster The world's fastest scanning speed (up

More information

FILE SCIENCE LABEL THE OF A MICROSCOPE OPERATION MANUAL

FILE SCIENCE LABEL THE OF A MICROSCOPE OPERATION MANUAL 10 February, 2018 FILE SCIENCE LABEL THE OF A MICROSCOPE OPERATION MANUAL Document Filetype: PDF 142.99 KB 0 FILE SCIENCE LABEL THE OF A MICROSCOPE OPERATION MANUAL Step by Step Guide to Fluorescence Microscopy

More information

Welcome to the 8 th MIC confocal microscopy course at the Dept. of Biomedicine, University of Bergen 31 st of January 3 rd of February 2012

Welcome to the 8 th MIC confocal microscopy course at the Dept. of Biomedicine, University of Bergen 31 st of January 3 rd of February 2012 Welcome to the 8 th MIC confocal microscopy course at the Dept. of Biomedicine, University of Bergen 31 st of January 3 rd of February 2012 The course focuses on the basic principles of confocal microscopy

More information

Transmitted light Illuminator VIS-LED, color temperature. Epifluorescence lamp module X-Cite 120PC Q (Excelitas

Transmitted light Illuminator VIS-LED, color temperature. Epifluorescence lamp module X-Cite 120PC Q (Excelitas ELYRA PS.1 Multi-functional fluorescence inverted widefield microscope enabling live-cell imaging, TIRF or HILO illuminion and two super-resolution techniques: structured illuminion microscopy (SIM) and

More information

INFINITY-CORRECTED TUBE LENSES

INFINITY-CORRECTED TUBE LENSES INFINITY-CORRECTED TUBE LENSES For use with Infinity-Corrected Objectives Available in Focal Lengths Used by Thorlabs, Nikon, Leica, Olympus, and Zeiss Designs for Widefield and Laser Scanning Applications

More information

Neuroscience Solutions. by leica microsystems

Neuroscience Solutions. by leica microsystems Neuroscience Solutions by leica microsystems neuroscience solutions from leica microsystems Working with Acute Slice Preparations The nervous system works as a tightly regulated, highly complex cellular

More information

DIAGRAM OF SIMPLE BINOCULAR MICROSCOPE E

DIAGRAM OF SIMPLE BINOCULAR MICROSCOPE E DIAGRAM OF SIMPLE BINOCULAR MICROSCOPE E Download Free PDF Full Version here! DIAGRAM OF SIMPLE BINOCULAR MICROSCOPE E PDF DOSBME 10CMRG 6 Diagram of simple binocular microscope e are a great way to achieve

More information

Leica TCS SPE. Spectacular Imaging! Technical Documentation

Leica TCS SPE. Spectacular Imaging! Technical Documentation Leica TCS SPE Spectacular Imaging! Technical Documentation Leica TCS SPE Spectacular Imaging Easy to Achieve A Reliable System Affordable Excellence The high resolution spectral confocal Leica TCS SPE

More information

Light Sheet Fluorescence Microscopy by Carl Zeiss. Chris Power 3D Imaging Specialist Dublin Workshop 25/11/2013

Light Sheet Fluorescence Microscopy by Carl Zeiss. Chris Power 3D Imaging Specialist Dublin Workshop 25/11/2013 Light Sheet Fluorescence Microscopy by Carl Zeiss Chris Power 3D Imaging Specialist Dublin Workshop 25/11/2013 Agenda 1. Requirements and challenges of live cell imaging 2. Light sheet fluorescence microscopy

More information

DiSPIM A Flexible Dual-View Light Sheet Microscope Platform

DiSPIM A Flexible Dual-View Light Sheet Microscope Platform DiSPIM A Flexible Dual-View Light Sheet Microscope Platform ASI s DiSPIM Team: John Zemek Gary Rondeau Jon Daniels President Technical Director DiSPIM Lead Engineer NIH Collaborators and Inventors: Hari

More information

Leica TCS SP5 X. X-citing Life The Only Confocal That Tunes Into Any Excitation

Leica TCS SP5 X. X-citing Life The Only Confocal That Tunes Into Any Excitation Leica TCS SP5 X X-citing Life The Only Confocal That Tunes Into Any Excitation Ready for any dye the future brings The only system that fully adapts to the sample Full freedom and flexibility in emission

More information

Investigator USERS GUIDE VERSION 10

Investigator USERS GUIDE VERSION 10 Stereo Investigator USERS GUIDE VERSION 10 Copyright, trademarks, and terms of use Information in this document, including URL and other Internet Web site references, is subject to change without notice.

More information

TN425: A study of fluorescence standards confirms that OptiGrid confocal images are suitable for quantitative microscopy

TN425: A study of fluorescence standards confirms that OptiGrid confocal images are suitable for quantitative microscopy TN425: A study of fluorescence standards confirms that OptiGrid confocal images are suitable for quantitative microscopy Introduction The OptiGrid converts the illumination system of a conventional wide

More information

Department of Chemistry

Department of Chemistry Department of Chemistry Guidelines for the Confocal Laser Scanning Microscopes The Department of Chemistry (CHEM) has two confocal laser scanning microscopes (confocal microscope) for imaging uses: 1.

More information

Cell Imaging Unit UIC Bárbara Fekete ZEISS AXIOIMAGER MICROSCOPE MANUAL

Cell Imaging Unit UIC Bárbara Fekete ZEISS AXIOIMAGER MICROSCOPE MANUAL Cell Imaging Unit UIC Bárbara Fekete ZEISS AXIOIMAGER MICROSCOPE MANUAL 1 TABLE OF CONTENTS ANATOMY OF THE ZEISS AXIOIMAGE MICROSCOPE 3 INITIALISATION PROCEDURE 4 LEFT SIDE OF MICROSCOPE (DETAILED VIEW)

More information

Obtaining Cell-Specific Analysis with the Laser Scapel. Is Lean Right for My Lab? May. No 6. Cell-Specific Analysis...page 1

Obtaining Cell-Specific Analysis with the Laser Scapel. Is Lean Right for My Lab? May. No 6. Cell-Specific Analysis...page 1 May 2008 No 6 Obtaining Cell-Specific Analysis with the Laser Scapel By Christoph Horlemann Marketing Life Science Research Leica Microsystems, Inc. Life Science Division The origin and course of many

More information

Diskovery. Multi-modal Imaging System

Diskovery. Multi-modal Imaging System Diskovery Multi-modal Imaging System Diskovery DISKOVERY SYSTEM CONFIGURATOR Diskover More Different tools are required to answer different questions. Now you can answer more questions about a sample during

More information

Quantitative Image Analysis and 3-D Digital Reconstruction of Aortic Valve Leaflet

Quantitative Image Analysis and 3-D Digital Reconstruction of Aortic Valve Leaflet Quantitative Image Analysis and 3-D Digital Reconstruction of Aortic Valve Leaflet Chi Zheng 1 Mentors: John A. Stella 2 and Michael S. Sacks, Ph. D. 2 1 Bioengineering and Bioinformatics Summer Institute,

More information

Leica LMD6 Leica LMD7

Leica LMD6 Leica LMD7 Leica LMD6 Leica LMD7 Laser Microdissection Systems Dissection perfection Index 2 Leica Laser Microdissection Systems Laser Microdissection (LMD) is a technology for precision sample preparation. In many

More information

Lecture 02 Microscopy, Staining, Classification (Ch3)

Lecture 02 Microscopy, Staining, Classification (Ch3) Lecture 02 Microscopy, Staining, Classification (Ch3) Topics Methods of Culturing Microorganisms Microscope (History, Types, Definitions) Staining (Gram s) Dichotomous keys Micro for Health Sciences 1

More information

Release Notes ZEN 2.3 SP1

Release Notes ZEN 2.3 SP1 Release Notes ZEN 2.3 SP1 Carl Zeiss Microscopy GmbH Carl-Zeiss-Promenade 10 07745 Jena, Germany microscopy@zeiss.com www.zeiss.com/microscopy Carl Zeiss Microscopy GmbH Königsallee 9-21 37081 Göttingen

More information

Pathobin Product Catalogue 2018

Pathobin Product Catalogue 2018 Pathobin Product Catalogue 2018 Download a purchase order form www.pathobin.com Pathobin 3D System... 3 Pathobin C-mount Camera... 5 Pathobin Mosaic software... 7 PathobinTools software... 9 2 Pathobin

More information

Dorigny resources MICROSCOPES - BIOPHORE. Confocal Microscope Zeiss LSM 700

Dorigny resources MICROSCOPES - BIOPHORE. Confocal Microscope Zeiss LSM 700 Dorigny resources Contributed by Yannick KREMPP Friday, 13 July 2007 Last Updated Monday, 30 October 2017 MICROSCOPES - BIOPHORE Confocal Microscope Zeiss LSM 700 This Zeiss LSM700 confocal is mounted

More information

SlicePlatform Fixed Platform System

SlicePlatform Fixed Platform System Experts in Electrophysiology & Imaging SlicePlatform Fixed Platform System Rock solid stability Mounting equipment www.scientifica.uk.com/sliceplatform 2 SlicePlatforms for upright microscopes Scientifica

More information