Selection and Ordering data. Selection and Ordering data

Size: px
Start display at page:

Download "Selection and Ordering data. Selection and Ordering data"

Transcription

1 Pointek CLS3, threaded version 7 M L Note: To select Standard or Digital CLS3 (with PROFIUS P), see final place holder under. Probe version (Threaded lengths include process thread.) Standard version, rod 35 mm (3.78 ) X Extended rod, length 5 mm (9.69 ) Extended rod, length 75 mm (29.53 ) Extended rod, length mm (39.37 ) C - Extended rod, factory adjusted length 25 to D 999 mm (9.8 to 39.3 ) - Extended cable, length 3 mm (8. ), 2 ) - Extended cable, length 6 mm (236.2 ), 2 ) - Extended cable, factory adjusted length to 2 C 4999 mm (39.4 to 96.8 ) ) - Extended cable, factory adjusted length 5 to 2 D 9999 mm (96.9 to ) ) - Extended cable, factory adjusted length 2 E to 4999 mm (393.7 to 59.5 ) ) - Extended cable, factory adjusted length 5 2 F to 9999 mm (59.6 to ) ) - Extended cable, factory adjusted length 2 2 G to 25 mm (787.4 to ) ) - Extended PF cable, length 3 mm (8. ), 3 ) and 2) - Extended PF cable, length 6 mm (236.2 ), 3 ) and 2) - Extended PF cable, length to 4999 mm 3 C (39.4 to 96.8 ) ) and 2) - Extended PF cable, length 5 to 9999 mm 3 D (96.9 to ) ) and 2) - Extended PF cable, length to 4999 mm 3 E (393.7 to 59.5 ) ) and 2) - Extended PF cable, length 5 to 9999 mm 3 F (59.6 to ) ) and 2) - Extended PF cable, length 2 to 25 mm 3 G ) and 2) (787.4 to ) Note: Verify that shield length selected in 7 and 8 is appropriate for the version selected. ¾ NPT [(Taper), NSI/SME.2.] 3) " NPT [(Taper), NSI/SME.2.] 3) ½ NPT [(Taper), NSI/SME.2.] C R ¾ [(SPT), EN 226/PT (JIS-T), JIS 23] 3) D R " [(SPT), EN 226/PT (JIS-T), JIS 23] 3) E R ½ [(SPT), EN 226/PT (JIS-T), JIS 23] F ¼ NPT [(Taper), NSI/SME.2.] K G ¾ [(SPP), EN ISO 228-/PF (JIS-P), L JIS 22] 3) G " [(SPP), EN ISO 228-/PF (JIS-P), M JIS 22] 3) G ½ [(SPP), EN ISO 228-/PF (JIS-P), N JIS 22] Pointek CLS3, threaded version 7 M L pprovals CS/FM Class II and III Div., Groups E, F, G T4 4) 2 CS/FM Class I Div., Groups,, C, D T4 4) 3 TEX II /2 D T C 4) 4 TEX II /2 G EEx d [ia] IIC T6 to T 4) 5 CS/FM Class II and III, Div, Groups E, F, G 6 T4 or T6; 5) TEX II /2D 2D T C 6) 7 E, F, G T4 or T6; TEX II G D /2D EEx ia IIC T6 to 5) and 6) T4 T C 8 E, F, G T4; TEX II /2GD EEx d [ia] IIC T6 to T T C 6) Not required Required 4) Enclosure (see also option ) luminum epoxy coated 2 x ½ NPT via adapter, cable inlet, IP65 2 x M2x.5 cable inlet, IP x ½ NPT via adapter, cable inlet, IP x M2x.5 cable inlet, IP68 4 dditional options Standard version 2 to 25 V C/DC, solid-state and relay output output and PROFIUS P 7) Please add -Z to and specify Order Total insertion length: enter the total insertion length Y Stainless steel tag [69 x 38 mm (2.7 x.5")]: Measuring-point number/identification (max. 2 charac- ters); specify in plain text Electrical connection/cable inlet: PROFIUS connector M26) and 8) Optional enclosure lid: Lid with glass window 4 instead of closed lid without window 9) cceptance test certificate: Manufacturer's test C certificate M to DIN 5535, Part 8 and ISO 9 Inspection Certificate Type 3. per EN 24 C2 SIL/IEC658 Declaration of Conformity [SIL 2 C2 (overspill)] 4) Extended ctive Shield (Y2) (standard length is 25 mm, not including threaded process connection length) ) ctive Shield length (Y2): 25 mm (min. insertion 7 length: rod, 475 mm, cable, mm) ctive Shield length (Y2): 4 mm (min. insertion 8 length: rod, 625 mm, cable, mm)

2 Pointek CLS3, threaded version 7 M L See page 5/4 ccessories See page 5/4 ) vailable with process connection C, F, J only 2) Do not select PF cable version if process temperature exceeds +2 C (+392 F). 3) vailable with Probe versions X, to D only 4) vailable with electronics option only 5) arrier required for Intrinsically Safe protection 6) vailable with electronics option only 7) n M2 PROFIUS connector can be selected separately with wildcard option. 8) vailable with enclosure option 2 only 9) Version with electronics option has a standard closed lid without window ) See dimension drawings on page 5/44 for further explanation of Y2.

3 Pointek CLS3, welded flange Note: To select Standard or Digital CLS3 (with PROFIUS P), see final place holder under. Probe version (length from flange face) Standard version, rod 35 mm (3.78 ) Extended rod, length 5 mm (9.69 ) Extended rod, length 75 mm (29.53 ) Extended rod, length mm (39.37 ) - Extended rod, length 25 to 999 mm (9.8 to 39.3 ) - Extended cable, length 3 mm (8. ), - Extended cable, length 6 mm (236.2 ), - Extended cable, length to 4999 mm (39.4 to 96.8 ) - Extended cable, length 5 to 9999 mm (96.9 to ) - Extended cable, length to 4999 mm (393.7 to 59.5 ) - Extended cable, length 5 to 9999 mm (59.6 to ) - Extended cable, length 2 to 25 mm (787.4 to ) - Extended PF cable, length 3 mm (8. ), ) - Extended PF cable, length 6 mm (236.2 ), ) 7 M L X C - Extended PF cable, length to 4999 mm (39.4 to 96.8 ) ) 3 C - Extended PF cable, length 5 to 9999 mm (96.9 to ) ) 3 D - Extended PF cable, length to 4999 mm (393.7 to 59.5 ) ) 3 E - Extended PF cable, length 5 to 9999 mm (59.6 to ) ) 3 F - Extended PF cable, length 2 to 25 mm (787.4 to ) ) 3 G Welded flange, 36L stainless steel, raised face " SME, 5 lb 2) " SME, 3 lb 2) 2 " SME, 6 lb 2) and 3) 3 ½" SME, 5 lb ½" SME, 3 lb 2 ½" SME, 6 lb 3) 3 2" SME, 5 lb C 2" SME, 3 lb C2 2" SME, 6 lb 3) C3 3" SME, 5 lb D 3" SME, 3 lb 3) D2 3" SME, 6 lb 3) D3 4" SME, 5 lb 3) E 4" SME, 3 lb 3) E2 4" SME, 6 lb 3) E3 D C 2 D 2 E 2 F 2 G 3 3 Pointek CLS3, welded flange 7 M L Welded flange, 36L stainless steel, Type flat faced DN 25, PN 6 2) J4 DN 25, PN 4 2) J6 DN 4, PN 6 K4 DN 4, PN 4 K6 DN 5, PN 6 L4 DN 5, PN 4 L6 DN 8, PN 6 M4 DN 8, PN 4 3) M6 DN, PN 6 3) N4 DN, PN 4 3) N6 (Note: Flange bolting patterns and facings dimensionally correspond to the applicable SME 6.5 or EN 92- standard.) pprovals CS/FM Class II and III Div., Groups E, F, G T4 4) 2 CS/FM Class I Div., Groups,, C, D T4 4) 3 TEX II /2 D T C 4) 4 TEX II /2 G EEx d [ia] IIC T6 to T 4) 5 CS/FM Class II and III, Div, Groups E, F, G T4 or 6 T6; 5) TEX II /2D 2D T C 6) 7 E, F, G T4 or T6; TEX II G D /2D EEx ia IIC T6 to 5) and 6) T4 T C 8 E, F, G T4; TEX II /2GD EEx d [ia] IIC T6 to T T C 6) Not required Required 4) dditional options Standard version Enclosure (see also option ) luminum epoxy coated 2 x ½ NPT via adapter, cable inlet, IP65 2 x M2x.5 cable inlet, IP65 2 x ½ NPT via adapter, cable inlet, IP68 2 x M2x.5 cable inlet, IP68 2 to 25 V C/DC, solid-state and relay output output and PROFIUS P 7) Please add -Z to and specify Order Total insertion length: enter the total insertion length Stainless steel tag [69 x 38 mm (2.7 x.5")]: Measuring-point number/identification (max. 2 characters); specify in plain text Electrical connection/cable inlet: PROFIUS connector M2 6) and 8) Optional enclosure lid: Lid with glass window instead of closed lid without window 9) cceptance test certificate: Manufacturer's test certificate M to DIN 5535, Part 8 and ISO 9 Inspection Certificate Type 3. per EN 24 SIL/IEC658 Declaration of Conformity [SIL 2 (overspill)] 4) Extended ctive Shield (Y2) (standard length is 5 mm) ) ctive Shield length (Y2): 23 mm (min. insertion length: rod, 475 mm, cable, mm) ctive Shield length (Y2): 38 mm (min. insertion length: rod, 625 mm, cable, mm) Y 4 C C2 C2 7 8 C D

4 Pointek CLS3, welded flange 7 M L See page 5/4 ccessories See page 5/4 ) Do not select PF cable version if process temperature exceeds +2 C (+392 F). 2) vailable with Probe versions X, to D only 3) Custom shipping methods required. Contact factory for more details. 4) vailable with electronics option only 5) arrier required for Intrinsically Safe protection 6) vailable with electronics option only 7) n M2 PROFIUS connector can be selected separately with wildcard option. 8) vailable with enclosure option only 9) Version with electronics option has a standard closed lid without window ) See dimension drawings on page 5/45 for further explanation of Y2.

5 Pointek CLS3, high temperature, threaded 7 M L Note: To select Standard or Digital CLS3 (with PROFIUS P), see final place holder under. Version (Threaded lengths include process thread.) Standard version, rod 35 mm (3.78 ) Extended rod, length 5 mm (9.69 ) Extended rod, length 75 mm (29.53 ) Extended rod, length mm (39.37 ) Extended rod, customer specified length (min. 25 mm (9.8 ) length, max. 999 mm (39.3 ) length) dd order code Y and plain text: "Insertion length...mm" Note: Verify that shield length selected in 7 or 8 is appropriate for the version selected. X C D 36L stainless steel ¾" NPT [(Taper), NSI/SME.2.] " NPT [(Taper), NSI/SME.2.] ½" NPT [(Taper), NSI/SME.2.] C R ¾" [(SPT), EN 226/PT (JIS-T), JIS 23] R " [(SPT), EN 226/PT (JIS-T), JIS 23] R ½" [(SPT), EN 226/PT (JIS-T), JIS 23] ¼" NPT [(Taper), NSI/SME.2.] K G ¾" [(SPP), EN ISO 228-/PF (JIS-P), JIS 22] G " [(SPP), EN ISO 228-/PF (JIS-P), JIS 22] G ½" [(SPP), EN ISO 228-/PF (JIS-P), JIS 22] pprovals CS/FM Class II and III Div., Groups E, F, G T4 ) 2 CS/FM Class I Div., Groups,, C, D T4 ) 3 TEX II /2 D T C ) 4 TEX II /2 G EEx d [ia] IIC T6 to T ) 5 CS/FM Class II and III, Div, Groups E, F, G T4 or T6; 2) TEX II /2D 2D T C 3) 6 E, F, G T4 or T6; TEX II G D /2D EEx ia IIC T6 to T4 T C2) and 3) E, F, G T4; TEX II /2GD EEx d [ia] IIC T6 to T T C 3) Not required Required ) Enclosure (see also option ) luminum epoxy coated 2 x ½ NPT via adapter, cable inlet, IP65 2 x M2x.5 cable inlet, IP65 2 x ½ NPT via adapter, cable inlet, IP x M2x.5 cable inlet, IP68 3 dditional options D E F L M N 7 8 Pointek CLS3, high temperature, threaded 7 M L to 25 V C/DC, solid-state and relay output output and PROFIUS P 4) Please add -Z to and specify Order Total insertion length: enter the total insertion length Stainless steel tag [69 x 38 mm (2.7 x.5")]: Measuring-point number/identification (max. 2 characters); specify in plain text Electrical connection/cable inlet: PROFIUS connector M23) and 5) Optional enclosure lid: Lid with glass window instead of closed lid without window 6) cceptance test certificate: Manufacturer's test certificate M to DIN 5535, Part 8 and ISO 9 Inspection Certificate Type 3. per EN 24 SIL/IEC658 Declaration of Conformity [SIL 2 (overspill)] ) Extended ctive Shield (Y2) [standard length is 25 mm (4.92 ), not including threaded process connection length] 7) ctive Shield length (Y2): 25 mm (9.84 ), [min. insertion length: rod 475 mm (8.7 ), cable mm (39.37 )] ctive Shield length (Y2): 4 mm (5.75 ). [min. insertion length: rod 625 mm (24.6 ), cable mm (39.37 )] Y 4 C C2 C2 7 8 See page 5/4 ccessories See page 5/4 ) vailable with electronics option only 2) arrier required for Intrinsically Safe protection 3) vailable with electronics option only 4) n M2 PROFIUS connector can be selected separately with wildcard option. 5) vailable with enclosure option only 6) Version with electronics option has a standard closed lid without window 7) See dimension drawings on page 5/44 for further explanation of Y2.

6 Pointek CLS3, high temperature, welded 7 M L flange Note: To select Standard or Digital CLS3 (with PROFIUS P), see final place holder under. Version (length from flange face) Standard version, rod 35 mm (3.78 ) X Extended rod, length 5 mm (9.69 ) Extended rod, length 75 mm (29.53 ) Extended rod, length mm (39.37 ) C Extended rod, customer specified length [min. D 25 mm (9.8 ) length, max. 999 mm (39.3 )length] dd order code Y and plain text: "Insertion length...mm" Note: Verify that shield length selected in 7 and 8 is appropriate for the version selected. Welded flange, 36L stainless steel, raised face " SME, 5 lb " SME, 3 lb 2 " SME, 6 lb ) 3 ½" SME, 5 lb ½" SME, 3 lb 2 ½" SME, 6 lb ) 3 2" SME, 5 lb C 2" SME, 3 lb C2 2" SME, 6 lb ) C3 3" SME, 5 lb D 3" SME, 3 lb ) D2 3" SME, 6 lb ) D3 4" SME, 5 lb ) E 4" SME, 3 lb ) E2 4" SME, 6 lb ) E3 Welded flange, 36L stainless steel, Type flat faced DN 25, PN 6 J4 DN 25, PN 4 J6 DN 4, PN 6 K4 DN 4, PN 4 K6 DN 5, PN 6 L4 DN 5, PN 4 L6 DN 8, PN 6 M4 DN 8, PN 4 ) M6 DN, PN 6 ) N4 DN, PN 4 ) N6 (Note: Flange bolting patterns and facings dimensionally correspond to the applicable SME 6.5 or EN 92- standard.) pprovals CS/FM Class II and III Div., Groups E, F, G T4 2) 2 CS/FM Class I Div., Groups,, C, D T4 2) 3 TEX II /2 D T C 2) 4 TEX II /2 G EEx d [ia] IIC T6 to T 2) 5 CS/FM Class II and III, Div, Groups E, F, G T4 or 6 T6; 3) TEX II /2D 2D T C 4) 7 E, F, G T4 or T6; TEX II G D /2D EEx ia IIC T6 to T4 T C3) and 4) 8 E, F, G T4; TEX II /2GD EEx d [ia] IIC T6 to T T C 4) Pointek CLS3, high temperature, welded 7 M L flange Not required Required 2) dditional options Enclosure (see also option ) luminum epoxy coated 2 x ½ NPT via adapter, cable inlet, IP65 2 x M2x.5 cable inlet, IP65 2 x ½ NPT via adapter, cable inlet, IP68 C 2 x M2x.5 cable inlet, IP68 D 2 to 25 V C/DC, solid-state and relay output output and PROFIUS P 5) Please add -Z to and specify Order Total insertion length: enter the total insertion length Y Stainless steel tag [69 x 38 mm (2.7 x.5")]: Measuring-point number/identification (max. 2 charac- ters); specify in plain text Electrical connection/cable inlet: PROFIUS connector M24) and 6) Optional enclosure lid: Lid with glass window 4 instead of closed lid without window 7) cceptance test certificate: Manufacturer's test C certificate M to DIN 5535, Part 8 and ISO 9 Inspection Certificate Type 3. per EN 24 C2 SIL/IEC658 Declaration of Conformity [SIL 2 C2 (overspill)] 2) Extended ctive Shield (Y2) [standard length is 5 mm (4.3 )] 8) ctive Shield length (Y2): 23 mm (9.6 ) [min. 7 insertion length: rod 475 mm (8.7 ), cable mm (39.37 )] ctive Shield length (Y2): 38 mm (4.96 ) [min. 8 insertion length: rod 625 mm (24.6 ), cable mm (39.37 )] See page 5/4 ccessories See page 5/4 ) Custom shipping methods required. Contact factory for more details. 2) vailable with electronics option only 3) arrier required for Intrinsically Safe protection 4) vailable with electronics option only 5) n M2 PROFIUS connector can be selected separately with wildcard option (). 6) vailable with enclosure option only 7) Version with electronics option has a standard closed lid without window 8) See dimension drawings on page 5/45 for further explanation of Y2.

7 English 7ML998-5CK4 German 7ML998-5CK34 French 7ML998-5CK4 Quick Start manual, multi-language C) 7ML998-5QF8 Note: Due to TEX regulations, one Quick Start manual is included with every product. ccessories ½ NPT cable gland, nickel plated brass, fits cable F) 7ML83-J diameter 6 to 2 mm (.24 to.47 ) -4 to + C (-4 to +22 F), IP68 (General Purpose) ½ NPT cable gland, brass, TEX II 2GD EEx d IIC F) 7ML83-J and EEx e II, fits cable diameter 6.5 to 4 mm (.26 to.55 ), -6 to +3 C (-76 to +266 F), IP68 (Explosion Proof) M2x.5 cable gland, P polyamide, TEX II 2G EEx e II, fits cable diameter 7 to 2 mm (.28 to.47 ), -2 to +7 C (-4 to +58 F), IP68 (General Purpose) F) 7ML83-JC M2x.5 cable gland, brass, TEX II 2GD EEx d IIC F) 7ML83-JD and EEx e II, fits cable diameter.5 to 5.9 mm (.4 to.63 ), under armour cable diameter 6. to.5 mm (.24 to.45 ), -6 to +3 C (-76 to +266 F), IP68 (Explosion Proof) One metallic cable gland M2x.5, -4 to +8 C (-4 to +76 F) F) 7ML93-P One metallic cable gland M2x.5, -4 to +8 C F) (-4 to +76 F) with integrated shield connection 7ML93-Q (available for PROFIUS P) lind threaded flanges are available. Please contact nacc.smpi@siemens.com with a completed application data sheet found on page 5/8. Spare parts Test magnet (digital version) 7ML83-JE mplifier/power supply, standard version C) 7ML83-DJ mplifier/power supply, digital version 7ML83-JF LCD display (digital version) 7ML83-JK C) Subject to export regulations L: N, ECCN: ER99 F) Subject to export regulations L: 9I999, ECCN: N

Level instruments. Point level measurement - Capacitance switches. Pointek CLS300 5/31

Level instruments. Point level measurement - Capacitance switches. Pointek CLS300 5/31 Level instruments Overview The unique modular design of the provides a wide range of configurations, process connections, extensions and approvals to meet the temperature and pressure requirements of specific

More information

Level instruments. Point level measurement - Capacitance switches. Pointek CLS200 5/15. Overview. Configuration

Level instruments. Point level measurement - Capacitance switches. Pointek CLS200 5/15. Overview. Configuration Level instruments Overview Configuration is a versatile inverse frequency shift capacitance level slurries, foam and interfaces. The digital version (with PROFIBUS PA) includes a display and provides additional

More information

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR560. 5/2 Siemens FI Overview.

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR560. 5/2 Siemens FI Overview. Overview onfiguration 2-wire, 78 GHz FMW radar level transmitter for continuous monitoring of solids in silos to a range of 100 m (329 ft). enefits rugged stainless steel design for industrial applications

More information

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min. Overview Configuration Mounting on a nozzle Min. clearance: 10 (0.4) Installation min. 1 000 (39) is a 2-wire 2 GHz pulse radar level transmitter for continuous monitoring of solids in storage vessels

More information

Continuous level measurement Radar transmitters

Continuous level measurement Radar transmitters Overview Configuration Mounting on a nozzle Min. clearance: 10 (0.4) Installation min. 1 000 (39) is a 2-wire 2 GHz pulse radar level transmitter for continuous monitoring of solids in storage vessels

More information

Continuous level measurement Ultrasonic transducers

Continuous level measurement Ultrasonic transducers Siemens G 2012 Level Measurement Overview Echomax XPS/XCT transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing

More information

SITRANS F flowmeters SITRANS F US. Flowmeter SONO 3300/FUS060 4/177. Technical specifications. Overview

SITRANS F flowmeters SITRANS F US. Flowmeter SONO 3300/FUS060 4/177. Technical specifications. Overview Overview The combination of sensor SONO 3300 sensor and FUS060 transmitter is ideal for applications within the general industry. Measurements are independent of liquid temperature, density, pressure and

More information

ECHOMAX XPS-10 ULTRASONIC TRANSDUCER

ECHOMAX XPS-10 ULTRASONIC TRANSDUCER Datasheet ECHOMX XPS-10 ULTRSONIC TRNSDUCER Supplied by.com Call us on + (0)118 916 920 Email info@27able.com Overview transducers use ultrasonic technology to measure level in a wide range of liquids

More information

Continuous level measurement Ultrasonic transducers

Continuous level measurement Ultrasonic transducers Siemens G 2012 Level measurement Overview EchoMax XPS/XCT transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing

More information

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level Measurement Continuous level measurement - Ultrasonic transmitters Overview Configuration is a short-range integrated ultrasonic level transmitter. It is intrinsically safe (ATEX, CSA, FM, IECEx, NEPSI), 2 wire, to 20 ma loop powered, ideal for liquids, slurries, and

More information

Level limit switch Series RF 3000 Selection list. Overview 2

Level limit switch Series RF 3000 Selection list. Overview 2 Table of content Overview 2 Page Applications 4 ------------------------------------------------------------------------------------------------------------- RF 3100 6 Standard version -------------------------------------------------------------------------------------------------------------

More information

Configuration. Installation

Configuration. Installation Overview SITRANS LR20 measures superbly in small vessels and in tanks/vessels up to 10 m (32 ft) on materials with dk > 3. Key Applications: liquid bulk storage tanks, process vessels with agitators, vaporous

More information

Siemens AG Continuous level measurement Radar transmitters. Configuration. Installation

Siemens AG Continuous level measurement Radar transmitters. Configuration. Installation Siemens AG 201 Overview Configuration Installation SITRANS LR250 is a 2-wire, 25 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on araday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

Continuous level measurement Ultrasonic transducers

Continuous level measurement Ultrasonic transducers Siemens G 2013 Overview transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing effect reduces blanking distance

More information

3/2 Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G1/2, 1/2 NPT or flanged with NAMUR interface

3/2 Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G1/2, 1/2 NPT or flanged with NAMUR interface 9805 / Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G/, / NPT or flanged with NMUR interface Main application: single operated process actuators TÜV-approval

More information

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level Measurement Continuous level measurement - Ultrasonic transmitters Overview Configuration is a short-range integrated ultrasonic level transmitter. This general purpose, 2-wire, to 20 ma loop powered transmitter is ideal for liquids, slurries, and bulk materials in open

More information

Level Measurement Continuous level measurement - Ultrasonic transducers

Level Measurement Continuous level measurement - Ultrasonic transducers Overview transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing effect reduces blanking distance Optional foam

More information

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI Overview The MAG 6000 I/6000 I Ex de is a microprocessorbased transmitter with a buildin alphanumeric display in several languages. The transmitters evaluate the signals from the associated electromagnetic

More information

/2 way indirect solenoid operated valves G 1/2, 1/2 NPT or flanged with NAMUR Interface

/2 way indirect solenoid operated valves G 1/2, 1/2 NPT or flanged with NAMUR Interface 9805 / way indirect solenoid operated valves G /, / NPT or flanged with NMUR Interface Main application: single operated actuators for plants Valves for safety systems up to SIL (IE 6508) dd-on manual

More information

98025 NAMUR 3/2 poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface

98025 NAMUR 3/2 poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface 9805 NMUR / poppet valves electromagnetic actuated, indirectly controlled G /, / NPT or flanged with NMUR Interface Main application: single operated actuators for plants Valves for safety systems up to

More information

Spare Parts for RM71 SmartLine Guided Radar Level Meter

Spare Parts for RM71 SmartLine Guided Radar Level Meter Spare Parts f RM71 SmartLine Guided Radar Level Meter XM71 All but 2mm F 2mm probe style see MSG 36-RM-16-06 (XM72) 36-RM-16U-05 Page 1 of 8 Model Selection Guide Supply the iginal instrument model code

More information

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug Vibration Limit Switch Features Limit switch for liquids External function test with test magnet Onsite function check possible thanks to LED indication Large selection of process connections for hassle-free

More information

Continuous level measurement Radar transmitters

Continuous level measurement Radar transmitters Overview Configuration Installation Note: Beam angle is the width of the cone where the energy density is half of the peak energy density Emission The peak energy density cone is directly in front of and

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M low sensor MAG P Overview Mode of operation The flow measuring principle is based on araday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage

More information

SITRANS F flowmeters SITRANS F US. SITRANS FUS1010 Standard clamp-on. 4/270 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. SITRANS FUS1010 Standard clamp-on. 4/270 Siemens FI Overview SITRNS F flowmeters Siemens G 2009 Overview SITRNS FUS1010 is the most versatile clamp-on ultrasonic flow display computer available today. It can operate in either Wide- Beam Transit-Time or Reflexor

More information

SITRANS F flowmeters SITRANS F US. SITRANS FUH1010 Oil clamp-on. 4/294 Siemens FI

SITRANS F flowmeters SITRANS F US. SITRANS FUH1010 Oil clamp-on. 4/294 Siemens FI SITRNS F flowmeters Siemens G 2009 Overview Standard volume (net) or mass flowmeters ( standard volume / mass ) Exceptional repeatability is maintained, independent of changes in temperature, density or

More information

Series 3730 Electropneumatic Positioner Type

Series 3730 Electropneumatic Positioner Type Series 3730 Electropneumatic Positioner Type 3730-0 Application Single-acting or double-acting positioner for attachment to pneumatic control valves Reference variable Travels 4 to 20 ma 5.3 to 200 mm

More information

PROFIBUS-PA Positioner Type 3785

PROFIBUS-PA Positioner Type 3785 PROFIBUS-PA Positioner Type 3785 Application Single-acting or double-acting PROFIBUS-PA positioner for attachment to pneumatic control valves. Rated travel from 7.5 to 120 mm Opening angle up to 120 Smart,

More information

Temperature Measurement SITRANS TS300

Temperature Measurement SITRANS TS300 Siemens AG 018 For food, pharmaceuticals and biotechnology modular design Dimensional drawings Cable gland M1x1.5 for cable Ø 3... 6.5 (0.1... 0.6) Ø 60 (.36) Ø d = N + H 1 Ø 50.5 (1.99) U X H 1 N H Ø

More information

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface 9805 / Directional control valves Direct solenoid operated poppet valves Internal thread G /, / NPT or flanged with NAMUR interface Main application: single operated actuators for plants TÜV-approval based

More information

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT 70 Inline 3/, / & /3 way spool valves electromagnetic actuated, indirectly controlled G/, / NPT, G/, / NPT Main application: single and double operated actuators TÜV-approval based on type examination

More information

26360, 80207, 3/2, 5/2 & 5/3 Indirect solenoid actuated spool valves

26360, 80207, 3/2, 5/2 & 5/3 Indirect solenoid actuated spool valves 66, 87, /, 5/ & 5/ > > Port size: G/ & G/ > > Compact design > > Easily interchangeable solenoid > > tandard manual override > > ll valves available with Ex protected coils (TEX or other international

More information

Level Measurement. Continuous level measurement Ultrasonic controller. SITRANS LUT400 series 5/337. Overview

Level Measurement. Continuous level measurement Ultrasonic controller. SITRANS LUT400 series 5/337. Overview Overview The Siemens controllers are compact, single point, long-range ultrasonic controllers for continuous level measurement of liquids, slurries, and solids, and high accuracy monitoring of open channel

More information

Magnetic float switch For vertical installation Model FLS

Magnetic float switch For vertical installation Model FLS Level measurement Magnetic float switch For vertical installation Model FLS WIKA data sheet LM 30.01 for further approvals see page 3 Applications Level measurement for almost all liquid media Pump and

More information

RT2Y Compact temperature switch intrinsic safety

RT2Y Compact temperature switch intrinsic safety ompact temperature switch intrinsic safety Main Features Excellent repeatability Fix dead band for control and alarm Resistant to accidental overtemperature Intrinsic safety Hazardous area 0, 1, 2 pplications

More information

Humidity limits % RH; freezing of condensed water not allowed in reference pressure channels.

Humidity limits % RH; freezing of condensed water not allowed in reference pressure channels. SATRON VDtL differential pressure transmitter belongs to V-transmitter family. The series V transmitters have both analog and smart properties. SATRON VDtL is used for 1.4 kpa...3 MPa ranges. It is a 2-wire

More information

Level Measurement. Continuous level measurement Ultrasonic controllers. SITRANS LUT400 series 5/337. Overview

Level Measurement. Continuous level measurement Ultrasonic controllers. SITRANS LUT400 series 5/337. Overview Overview The Siemens controllers are compact, single point, long-range ultrasonic controllers for continuous level or volume measurement of liquids, slurries, and solids, and high accuracy monitoring of

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730-0 Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves Set point Travel 4 to 20 ma 5.3 to 200 mm The positioner

More information

SITRANS L Level instruments

SITRANS L Level instruments Overview Technical specifications Mode of Operation Measuring principle Ultrasonic level measurement Measuring range 0.3 to 1 m (1 to 0 ft), transducer dependent Measuring points 1 or 2 Input Analog 0

More information

Siemens AG Level Measurement

Siemens AG Level Measurement Level Measurement /2 Product Overview Point level measurement /7 Capacitance switches /10 Pointek CLS100 /16 Pointek CLS200 Standard /25 Pointek CLS200 Digital /3 Pointek CLS200 - Standard and Digital

More information

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7 90 NAMUR /, / and / directional valves Actuation: electromagnetic Indirectly controlled soft seal spool valves Port size: G /, / NPT, G /, / NPT NAMUR-interface For single and double operated actuators

More information

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2. e X L i n k exlink 7-pole / 6-pole + PE for Zone 1 and Zone 21 Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2. The exlink 7

More information

Roxar SandLog High Accuracy Sand/Erosion Monitoring

Roxar SandLog High Accuracy Sand/Erosion Monitoring FA-T201-C Product Data Sheet 01.12.2016 High Accuracy Sand/Erosion Monitoring The effective management of sand is important for the integrity of oil and gas assets and for optimizing production. Together

More information

PROFIBUS Junctions, Connectors, Accessories

PROFIBUS Junctions, Connectors, Accessories Data heet PROFIU Junctions, Connectors, ccessories PROFIU P Junctions Connectors ccessories PROFIU DP Junctions Connectors ccessories PROFIU DP/P ccessories P R O F I PROCE FIELD U U PROFIU Junctions,

More information

Electropneumatic Positioner Type and Type with HART communication

Electropneumatic Positioner Type and Type with HART communication Electropneumatic Positioner Type 3730-2 and Type 3730-3 with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-adjusting, automatic

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview Benefits It is compact and light, fitting neatly into dense piping arrangements Easy maintenance because modules can be exchanged rapidly Effective separation of measurement from plant vibration

More information

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT 705 Inline 3/, 5/ & 5/3 spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Valves for safety systems up to SIL (IEC 6508) Crossover-free

More information

BSP & HOSE Fittings M5, 1/8... 1

BSP & HOSE Fittings M5, 1/8... 1 SP & HOS Fittings M5, 1/8... 1 Very compact units asy tube insertion for rapid assembly of pneumatic circuits Positive tube anchorage All taper threads pre-coated with non-ptf based sealant Straight Adaptors

More information

Technical features. N/en

Technical features. N/en /, 5/ & 5/ spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT or flanged with NAMUR interface For single and double operated actuators Exhaust air recirculation at way

More information

HERION SERIES Indirect solenoid actuated spool valves

HERION SERIES Indirect solenoid actuated spool valves HERION SERIES Indirect solenoid actuated spool valves for single and double acting actuators with NAMUR interface /2, /2, /, NC/APB, G/, G/2 Valves for safety systems up to SIL (IEC 08) Crossover-free

More information

General Specifications

General Specifications General Specifications Model RAGH Rotameter This type of Rotameter is designed for measurement of liquids and gases. The conical glass metering tube has a free rotating float. The mounting position is

More information

Operating pressure (bar)

Operating pressure (bar) / poppet valves electromagnetic actuated, directly controlled G /4, /4 NPT, G /, / NPT or flanged with NAMUR Interface Main application: single operated actuators for plants Valves for safety systems up

More information

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters For operation in up to Zone 0 / 20 Features Measures humidity and temperature, outputs also dew point, mixing ratio, absolute humidity

More information

Roxar CorrLog High Accuracy Corrosion Monitoring

Roxar CorrLog High Accuracy Corrosion Monitoring FA-T200-C Product Data Sheet 01.12.2016 High Accuracy Corrosion Monitoring Fast and reliable corrosion monitoring is a key for efficient corrosion management and control. In-line corrosion monitoring provides

More information

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUG1010 (Gas) 4/336 Siemens FI Overview

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUG1010 (Gas) 4/336 Siemens FI Overview Siemens G 2010 Overview pplication SITRNS FUG1010 is ideal for most natural and process gas industry applications, including: Checkmetering llocation Flow survey verification Lost and unaccounted for (LUF)

More information

Technical features. 12/ f. N/en

Technical features. 12/ f. N/en /, / & / way spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT or flanged with NAMUR interface Main application: single and double operated actuators TÜV-approval based

More information

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application. DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential

More information

Capacitance level switches LS 210 LS 220

Capacitance level switches LS 210 LS 220 KROHNE 03/2001 7.02374.31.00 GR/PRINTO Capacitance level switches Compact switches for liquids, solids, slurry, foam and interface; outstanding performance for a low price Easy to install, no moving parts,

More information

Assembly. max Example: 2-wire connection IH More connection types see section electrical connections. Auxiliary voltage.

Assembly. max Example: 2-wire connection IH More connection types see section electrical connections. Auxiliary voltage. Guided Level Radar Features Measurement independent of density, temperature, and dust Measurement also possible with foam on the surface Simple, menu-guided on-site operation with four-line plain text

More information

5 Fieldbus Technology

5 Fieldbus Technology 5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically

More information

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2-16; P=87 PSI Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a clear,

More information

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA Patented quality product (Immersion sensor patent no. DE 10 2012 017 500.0) Calibratable temperature measuring transducer THERMASGARD with eight switchable measuring ranges, continuous linear output, enclosure

More information

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter DMP Nominal pressure

More information

Standard enclosure for Remote I/O Series 8150

Standard enclosure for Remote I/O Series 8150 > Stainless steel enclosure for installation in Zone 1 > Standard versions - available in max. 3 weeks > Prepared for the installation of IS1+ Remote I/O > For up to 112 analog or 224 digital signals >

More information

RT2E Compact temperature switch Explosion proof

RT2E Compact temperature switch Explosion proof ompact temperature switch Explosion proof Main Features Excellent repeatability Dead band adjustment for regulation Fix dead band for control and alarm Light weight Explosion proof Hazardous areas 1, 2,

More information

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0. LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:

More information

6215L Inline & NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

6215L Inline & NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve L Inline & NMUR series, / & / > Port size: / (ISO /NPT) or flanged with NMUR interface > Suited for outdoor use under critical environment conditions (see solenoid list) > Variable valve solenoid combination

More information

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication Series 3730 Electropneumatic Positioner Type 3730-4 with PROFIBUS-PA communication Application Positioner for attachment to pneumatic control valves Travels 3.6 to 200 mm Opening angle 24 to 100 Smart,

More information

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Float Switches with Permanent Magnet For Vertical Installation Model RSM Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring

More information

RHM160. Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications. Features. Applications. Benefits

RHM160. Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications. Features. Applications. Benefits RHM160 Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications Features Standard Pressure ratings up to 50bar (725 psi) Temperature ratings from -196 to 120 C (-320 to 248 F) Mass flow

More information

Pipe fittings and flanges, sockets for bayonet locks

Pipe fittings and flanges, sockets for bayonet locks Data Sheet 909750 (909725) Page 1/7 Pipe fittings and flanges, sockets for bayonet locks for temperatures up to 600 C for different fitting lengths simple installation and replacement pressure-tight sealing

More information

Rosemount 1595 Conditioning Orifice Plate

Rosemount 1595 Conditioning Orifice Plate Rosemount 1595 Conditioning Orifice Plate Ordering information Rosemount 1595 Conditioning Orifice combines a flow conditioner with an orifice plate into a highly accurate primary element. Requires only

More information

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2. 66, 87 Inline / and 5/ directional control valves NG 6 and Operation: elektromagnetic Indirectly controlled soft seal spool valves Port size: G /4 and G / For single and double operated actuators Manual

More information

Assembly. Connection FEL 52 (E5) 3-wire DC connection (example) FEL 52 (E5) 0.5 A U V DC V DC

Assembly. Connection FEL 52 (E5) 3-wire DC connection (example) FEL 52 (E5) 0.5 A U V DC V DC Vibration Limit Switch Features Assembly Level limit switch for liquids Large selection of process connections: universal use Wide variety of electronic modules (e. g., relay, thyristor signal output):

More information

Level measurement. Continuous level measurement Ultrasonic controllers. SITRANS LUT400 series. 4/146 Siemens FI Overview

Level measurement. Continuous level measurement Ultrasonic controllers. SITRANS LUT400 series. 4/146 Siemens FI Overview Level measurement SITRNS LUT00 series Siemens G 2013 Overview pplication The SITRNS LUT00 comes in three different models, depending on the application, level of performance and functionality required:

More information

Threaded thermocouple Miniature design Model TC10-D

Threaded thermocouple Miniature design Model TC10-D Temperature Threaded thermocouple Miniature design Model TC10-D WIKA data sheet TE 65.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion technology

More information

15 and 16 Series BSP and hose fittings

15 and 16 Series BSP and hose fittings SP and hose fittings > > Port size: M5, 1/8... 1 > > xtensive range of shapes and sizes including manifolds > > High temperature and pressure copper sealing washers supplied with ISO threads Technical

More information

NIVOSWITCH VIBRATING FORK LEVEL SWITCHES

NIVOSWITCH VIBRATING FORK LEVEL SWITCHES For liquids and solids NIVOSWITCH VIBRATING FORK LEVEL SWITCHES OUR PROFESSION IS YOUR LEVEL LEVEL SWITCHES O U R P R O F E S S I O N I S NIVOSWITCH VIBRATING FORK LEVEL SWITCHES MAIN FEATURES and mini

More information

Cable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof

Cable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof 757 Series Blanking Plugs 737 Series Adaptors and Reducers BVE Series Plastic Blanking Plugs & Sealing Washers Compliance Data: 757 Series Blanking Plugs: ATEX IECEx CE Ex d IIC or Ex e II Ex td A21 IP

More information

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration

More information

97105 NAMUR, 3/2, 5/2 & 5/3 Indirect electromagnetic actuated spool valves

97105 NAMUR, 3/2, 5/2 & 5/3 Indirect electromagnetic actuated spool valves 970 NAMUR, /, / & / > > Port size: / or / ISO G/NPT > > Main application: single and double operated actuators > > TÜV-approval based on type examination DIN EN, DIN 9 and IEC 08 > > Valves for safety

More information

SITRANS L Level instruments

SITRANS L Level instruments Siemens AG 2007 SITRANS L Level instruments Overview of probe configurations is available, including rod and cable versions. Key Applications: liquids, slurries, bulk solids, relatively high pressure and

More information

26360, NAMUR. Technical data

26360, NAMUR. Technical data 66, 87 NAMUR /-, /- and / directional control valves Operation: elektromagnetic Indirectly controlled soft seal spool valves Port size: G/ NAMUR-Interface For single and double operated actuators Manual

More information

Threaded resistance thermometer Miniature design Model TR10-D

Threaded resistance thermometer Miniature design Model TR10-D Temperature Threaded resistance thermometer Miniature design Model TR10-D WIKA data sheet TE 60.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion

More information

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module) Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source

More information

SITRANS F flowmeters SITRANS F US

SITRANS F flowmeters SITRANS F US SITRANS F flowmeters Siemens AG 2008 Overview Application SITRANS FUG1010 is ideal for most natural and process gas industry applications, including: Checkmetering Allocation Flow survey verification Lost

More information

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration

More information

Material pressure (bar) (Cv (US) kv x 1,2 Seat

Material pressure (bar) (Cv (US) kv x 1,2 Seat 00 / poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 08, DIN V Valves for safety systems up to SIL Solenoid valve also

More information

21D Allfluid pressure switch, electromechanically actuated

21D Allfluid pressure switch, electromechanically actuated D > > 0,... 0, bar (0,... psi), G/, / NPT > > High accuracy > > High number of switching cycles > > Microswitch approved by UL and CSA > > Fixed or adjustable hysteresis > > Shock and vibration tested

More information

Variable Area Flowmeter DATASHEET

Variable Area Flowmeter DATASHEET Variable Area Flowmeter DATASHEET JUNHO 0 Data sheet DS/A6/6EN Rev. I Models A600 & A600 Purgemaster SNAP-IN Small Flowmeter Long-term reliable performance flowmeters with low cost-of-ownership High strength

More information

G 1/2 30,5 A Brass NBR 0,8 3,

G 1/2 30,5 A Brass NBR 0,8 3, 4/2 way poppet valves electromagnetic actuated, directly controlled /4 & /2 Working from 0 bar up Suitable for vacuum range down.33 0-2 mbar l/s Protection class : IP 65, Ex em, Ex d TEX approved (see

More information

Level Measurement Continuous level measurement - Ultrasonic controllers

Level Measurement Continuous level measurement - Ultrasonic controllers Continuous level measurement Ultrasonic controllers Overview is a versatile short to mediumrange ultrasonic single and multivessel level monitor/controller for virtually any application in a wide range

More information

Level Measurement. Continuous level measurement - Ultrasonic controllers. SITRANS LU01 and LU02. 5/156 Siemens FI Overview.

Level Measurement. Continuous level measurement - Ultrasonic controllers. SITRANS LU01 and LU02. 5/156 Siemens FI Overview. SITRANS LU and LU Siemens AG Overview Overview The SITRANS LU is an ultrasonic long-range level controller for liquids and solids in a single vessel up to 6 m ( ft). Handheld programmer shown is an accessory

More information

8125 Series Terminal Boxes

8125 Series Terminal Boxes 8 Series Terminal oxes TERMINTION Ready-Term 8 Terminal oxes Features: Pre-onfigured with terminals mounted Materials: Stainless Steel or arbon Steel Six enclosure sizes with different depths For power

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series Description Page Introduction to Cable Glands 399 EEXe Series 400-401 Polyamide Cable Glands for Unarmored Cable Increased Safety EEXe Series Ex e Certified Ex I Application Entry Thread Seal A2F, E1FX/E2FX,

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730- Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and

More information

Operating pressure (bar) kv factor (m 3 /h) *3)

Operating pressure (bar) kv factor (m 3 /h) *3) / way poppet valves (stainless steel) electromagnetic actuated, directly controlled G /8, G /4 or /4 NPT Working from 0 bar up Assembled free of oil and grease Suited for fine vacuum down to,33 0 - mbar

More information

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights HygroFlex & HygroClip-EX HygroFlex series may be used together with the intrinsically safe HygroClip-EX probes. The relative humidity and temperature can be displayed and output as analog signals. Calculated

More information