Modular Contactors Modular Contactors 2 Day-Night-Reloading Contactors 3. Contactors and Overload Relays Contactors -AC Operated 4
|
|
- Jocelyn Bradford
- 5 years ago
- Views:
Transcription
1 Device page Modular Contactors Modular Contactors 2 Day-Night-Reloading Contactors 3 Contactors and Overload Relays Contactors -AC Operated 4 Contactors -DC Operated 5 Overload Relays 6, 7 Star Delta Starters 8 D.O.L. Starters 8 Manual Motor-Starters Manual Motor-Starters 9 Circuit Breakers 10, 11 Push Buttons Switches Main Switches NEW Net Changeover Switches 15 Cam Switches
2 Modular Contactors low noise, low coil power consumption 1-, 2-Pole 1 Module (17,5mm) Rated Power Rating Motor Type Current AC1 AC3 NO 400V 230V 400V 400V NC AC1 1~ 3~ 3~ Coil A kw kw kw V AC 20 4,6 - - R ,6 - - R ,6 - - R ,6 - - R ,6 - - R ,6 - - R ,6 - - R Pole 2 Modules (35mm) 1) 25 5, R , R , R , R , R , R ,7 - - R ,7 - - R , R , R Pole 3 Modules (52,5mm) 1) ,5 12,5 R ,5 12,5 R ,5 12,5 R ,5 12,5 R R R ,5 12,5 R ,5 12,5 R , R , R , R , R ,3 - - R ,3 - - R , R , R ) Sealable with Sealing Cover (see page 3) 2) Switching of lamps see Catalog D681..,page 7, 8 Technical datas see Catalog D681..,page 9 Dimensions see Catalog D681..,page 11 2
3 Accessories for Modular Contactors Auxiliary Contact Block Rated current Therm. AC15 Current 230V 400V I th A A A Type ½ module (8,8mm) RH11 3 for R25, R40 and R63, for low level switching Sealing cover Sealing cover for R25.. Sealing cover for R40.., R63.. P P Suppressor unit RC-unit RC-R x for R20.. to R63.. for 12V to 250V AC 1 module (17,5mm) Spacing piece ½ module (8,8mm) for R20.. to R63.. P Day- Night Reloading Contactors Compact Module, for separate tarif counters 2 modules (35mm) 400V I th A Type 25 R25-TN Switch positions: Day (Reloading, contact closed, remains in position Night, until the next occurs) Night (Basis operation) contact closed Contactor Module, for double tarif counters 1 module (17,5mm) 25 R25-TN Switch position: Day (Reloading, contact closed, remains in position Night, until the next occurs) Night (automatic operation, contact only at night closed) On (Permanently On) Off (permanently Off) Switch Module 1 module (17,5mm) 25 RH
4 Contactors -AC Operated (Coil V AC) Mini-Contactor Relays AC15 Rated additionally Type 230V Current aux. contacts NO I th max. NC A A Coil V AC HK.. K1-07D HK.. K1-07D HK.. K1-07D HK.. K1-07D Mini-Contactors Motor Rated additionally Type AC3 Current aux. contacts NO 400V I th max. NC kw A Coil V AC HKM.. K1-09D HKM.. K1-09D , HKM.. K1-12D , HKM.. K1-12D Contactors Motor Rated additionally Type AC3 Current aux. contacts NO 400V I th max. NC kw A Coil V AC HN.. K3-10A HN.. K3-10A , HN.. K3-14A , HN.. K3-14A , HN.. K3-18A , HN.. K3-18A HN.. K3-22A HN.. K3-22A HN..+2 HB.. K3-24A HN..+2 HB.. K3-32A , HN..+2 HB.. K3-40A HN..+2 HB.. K3-50A HN..+2 HB.. K3-62A HN..+2 HB.. K3-74A HN..+2 HB.. K3-90A HN..+2 HB.. K3-115A kW Accessories see page 6 4
5 Contactors -DC Operated (Coil V DC) Mini-Contactor Relays AC15 Rated additionally Type 230V Current aux. contacts NO I th max. NC A A Coil V DC HK.. K1-07D40= HK.. K1-07D22= Mini-Contactors Motor Rated additionally Type AC3 Current aux. contacts NO 400V I th max. NC kw A Coil V DC HKM.. K1-09D10= , HKM.. K1-12D10= Contactors Motor Rated additionally Type AC3 Current aux. contacts NO 400V I th max. NC kw A Coil V DC integrated suppressor unit Coil 3W HN.. KG3-10A , HN.. KG3-14A , HN.. KG3-18A HN.. KG3-22A integrated suppressor unit Coil 4W HN..+2 HB.. KG3-24A HN..+2 HB.. KG3-32A , HN..+2 HB.. KG3-40A HN..+2 HB.. K3-90A HN..+2 HB.. K3-115A Accessories see page 6 5
6 Accessories for Contactors Auxiliary Contact Blocks for Mini-Contactors contacts AC15 Type NO NC 230V I th for contactor A A K1-07D HK HK HK HK HK40 10 K1-09D HKM11 10 K1-12D HKM HKM HKM HKM31 10 Auxiliary Contact Blocks for Contactors K3 K to K HN10 10 KG to KG HN01 10 K to K HB11 10 KG to KG HB02 10 Suppressor Units for contactor Voltage range Execution Type K to K V AC/DC RC RC-K V AC/DC RC RC-K K to K V AC/DC Varistor K2-E V AC/DC Varistor K2-E K to K V AC/DC RC RC-K V AC/DC RC RC-K K85 to K V AC RC RC-AD22/ V AC RC RC-AD047/230 5 Overload Relays for Mini-Contactors Motor Setting Range Fuse acc. Type VPE AC3 coordination 400V am gl(gg) kw A A A "2" 0,12-0,18-0,5 U12/16E 0,18 K1 1 0,06 0,18-0,27-1,0 U12/16E 0,27 K1 1 0,09 0,27-0,4-2 U12/16E 0,4 K1 1 Hand Reset 0,12 0,4-0,6-2 U12/16E 0,6 K1 1 electric. insulated 0,18 0,6-0,9-4 U12/16E 0,9 K1 1 auxiliary contacts 0,25 0,8-1,2 2 4 U12/16E 1,2 K1 1 1NO + 1NC 0,37 1,2-1,8 2 6 U12/16E 1,8 K1 1 0,75 1,8-2, U12/16E 2,7 K1 1 1,5 2, U12/16E 4 K1 1 2, U12/16E 6 K U12/16E 9 K U12/16E 11 K1 1 5, U12/16E 14 K1 1 6
7 Overload Relays Overload Relays U12/16E.. Motor for Setting Range Fuse acc. Type AC3 Contactor coordination 400V am gl(gg) kw A A A "2" Typ K(G)3-10A.. 0,12-0,18-0,5 U12/16E 0,18 1 0,06 0,18-0,27-1,0 U12/16E 0,27 1 0,09 0,27-0,4-2 U12/16E 0,4 1 0,12 0,4-0,6-2 U12/16E 0,6 1 Hand Reset 0,18 0,6-0,9-4 U12/16E 0,9 1 0,25 0,8-1,2 2 4 U12/16E 1,2 1 0,37 1,2-1,8 2 6 U12/16E 1,8 1 0,75 1,8-2, U12/16E 2,7 1 1,5 2, U12/16E 4 1 2, U12/16E U12/16E U12/16E ,5 K(G)3-14A U12/16E ,5 K(G)3-18A U12/16E K(G)3-22A U12/16E 23 1 Overload Relays U3/32.. K(G)3-10A.. 0,12-0,18-0,5 U3/32 0,18 1 0,06 0,18-0,27-1,0 U3/32 0,27 1 0,09 0,27-0,4-2 U3/32 0,4 1 0,12 0,4-0,6-2 U3/32 0,6 1 0,18 0,6-0,9-4 U3/32 0,9 1 Hand- Automatik Reset 0,25 0,8-1,2 2 4 U3/32 1,2 1 sealable 0,37 1,2-1,8 2 6 U3/32 1,8 1 0,75 1,8-2, U3/32 2,7 1 1,5 2, U3/ , U3/ U3/ U3/ ,5 K(G)3-14A U3/ ,5 K(G)3-18A U3/ K(G)3-22A U3/ K(G)3-24A U3/ K(G)3-32A U3/ Overload Relays U3/42.., U3/ K3-24A U3/ K3-32A U3/ ,5 K3-40A U3/ K3-50A U3/ Hand- Automatik Reset 30 K3-62A U3/ K3-74A U3/
8 Motor-Starter Star-Delta Starter Motor AC3 Wired to accept Overload Relays Type 400V 400V YD-Setting Range = 0,58 x I n kw A Coil V AC 7,5 16 U3/32.. K3Y U3/32.. K3Y U3/42.. K3Y U3/42.. K3Y U3/74.. K3Y U3/74.. K3Y Main- and U85.. K3Y Control lines are wired U85.. K3Y Plastic Enclosure IP65, 280x200x125 mm for K3Y and K3Y K3Y26P-G3 1 D.O.L. Starter with Selector Switch, IP65 Motor AC3 additionally Wired to accept Type 400V attachable Overload Relay kw aux. contacts (order separate) Coil V AC 4 2pcs HN.. U12/16.. P1W pcs. HN.. U12/16.. P1W ,5 2pcs HN.. U12/16.. P1W ,5 2pcs HN.. U12/16.. P1W D.O.L. Starter with Start-Stop / Reset Push Button, IP65 4 2pcs HN.. U12/16.. P1T pcs HN.. U12/16.. P1T ,5 2pcs HN.. U12/16.. P1T ,5 2pcs HN.. U12/16.. P1T D.O.L. Starter for Swimming pools 7,5 2pcs HN.. U12/16.. P1W16P with selector switch and pneumatik switch, IP65 Pneumatic button and air pressure hose order separate Pneumatic Button P1LT 1 Air Pressure Hose P1LS-5 1 Length: 5m 8
9 Manual Motor Starters Auxiliary Contact Blocks Thermal Ratings Magnetic Short Circuit Overload release AC3 Short Circuit Breaking Setting Range 400V690V Trip Capacity at A kw kw A 3~400V Type 0,1-0,16 0,02 0,06 1,92 100kA MU25A-0,16 2 0,16-0,25 0,06 0,12 3,0 100kA MU25A-0,25 2 0,25-0,4 0,09 0,18 4,8 100kA MU25A-0,4 2 0,4-0,63 0,12 0,25 7,6 100kA MU25A-0,63 2 0,63-1 0,25 0,55 12,0 100kA MU25A ,6 0,55 1,1 19,2 100kA MU25A-1,6 2 1,6-2,5 1,1 1, kA MU25A-2,5 2 2,5-4 1, kA MU25A ,3 2,5 4 75,6 100kA MU25A-6,3 2 6, , kA MU25A , kA MU25A kA MU25A ,5 18, kA MU25A , kA MU25A-32 2 AC15/230V I th Mounting Type A A 1 5 snap-on MU25A-PA Pc. 3,5 6 side MU25A-PS11 10 max. 2 Release, mounting under the cover Execution Control voltage Type mounting under the cover Shunt release V 50Hz MU25A-A max. 1 pc. Under voltage release V 50Hz MU25A-U Enclosure with CEE-Plug Execution Description Type Moulded Enclosure Protection to IP55 MU25A-O55 1 Moulded Front plate Protection to IP55 MU25A-C55 1 for CEE-Plug 5-pole, Moulded Enclosure, Protection to IP54 MU25A-GC1 1 with built-in Phase reversing Busbar Connectors Execution Description Type Busbar for 2 units, length 99mm MU25A-D99 10 Busbar for 3 units, length 154mm MU25A-D Busbar for 4 units, length 208mm MU25A-D Busbar for 5 units, length 262mm MU25A-D Supply Block isolated, U i 690V, I u 63A MU25A-DB 10 Protection Cover for unused busbar terminals MU25A-BS 10 9
10 Circuit Breakers for Motor Control Circuit Breaker M4-32T-.. Rated Suitable Setting range Instantaneous Short Circuit Current I n for Thermal Short Circuit Breaking motors Overload Release Capacity at 3~400V Release 3~400V A kw 1) A A ka Type switch type - 0,10 0,16 2, ,16 M4-32T-0,16 1 0,06 0,16 0,25 3, ,25 M4-32T-0,25 1 0,09 0,25 0,4 5, ,4 M4-32T-0,4 1 0,12 0,40 0,63 8, ,63 M4-32T-0,63 1 0,25 0, M4-32T-1 1 0,55 1,0 1,6 20, ,6 M4-32T-1,6 1 0,75 1,6 2,5 32, ,5 M4-32T-2,5 1 1,5 2, M4-32T-4 1 2, M4-32T M4-32T M4-32T , M4-32T , M4-32T , M4-32T M4-32T M4-32T-32 1 Circuit Breaker M4-32R-.. rotary type - 0,10 0,16 2, ,16 M4-32R-0,16 1 0,06 0,16 0,25 3, ,25 M4-32R-0,25 1 0,09 0,25 0,4 5, ,4 M4-32R-0,4 1 0,12 0,4 0 0,63 8, ,63 M4-32R-0,63 1 0,25 0, M4-32R-1 1 0,55 1,0 1,6 20, ,6 M4-32R-1,6 1 0,75 1,6 2,5 32, ,5 M4-32R-2,5 1 1,5 2, M4-32R-4 1 2, M4-32R M4-32R M4-32R , M4-32R , M4-32R , M4-32R M4-32R M4-32R-32 1 Circuit Breaker M4-63R-.. rotary type M4-63R M4-63R , M4-63R M4-63R M4-63R-63 1 Circuit Breaker M4-100R-.. rotary type M4-100R M4-100R M4-100R M4-100R ) Approximate values of standard motors 10
11 Accessories for Circuit Breakers M4 contacts Rated current Type AC15 AC1 24V 240V 240V NO NC A A A Auxiliary Contact Block, transverse mounting max. 1Pc. per circuit breaker M4 HQ M4 HQ20 1 Auxiliary Contact Block, left hand side mounting, max. 1Pc. per circuit breaker M4 HS M4 HS M4 HS02 1 Signalling Switch, left hand side mounting, max. 1Pc. per circuit breaker M4 MA11 1 Undervoltage release, right hand side mounting, max. 1Pc. per circuit breaker Trips the circuit-breaker when the voltage is interrupted. Prevents the motor from beeing restarted when voltage is restored suitable for EMERGENCY STOP (VDE0113) 24V 50Hz, 28V 60Hz M4 U V 50Hz, 120V 60Hz M4 U V 50Hz, V 60Hz M4 U V 50Hz, 277V 60Hz M4 U V 50Hz, V 60Hz M4 U V 50Hz, V 60Hz M4 U415 1 Shunt release, right hand side mounting, max. 1Pc. per circuit breaker Trips the circuit-breaker when the release coil energized. 24V 50Hz, 28V 60Hz M4 A V 50Hz, 120V 60Hz M4 A V 50Hz, V 60Hz M4 A V 50Hz, 277V 60Hz M4 A V 50Hz, V 60Hz M4 A V 50Hz, V 60Hz M4 A415 1 Enclosure for circuit breaker M4 32R protection degree IP65 Plastic enclose with rotary operating mechanism black-grey lockable, with N- and PE-terminal space for 1 transverse and side aux. contact + release M4 32R PFH4 1 Enclose with rotary operating mechanism yellow - red, lockable with N- and PE-terminal space for 1 transverse and side aux. contact + release M4 32R PFHN4 1 11
12 Control Units, Ø 22,5 mm, IP67 alu chrome black Push Buttons red B3D RT markable green B3D GN blue B3D BL yellow B3D GE black B3D SW Push Buttons, maintained red B3DR RT markable green B3DR GN blue B3DR BL yellow B3DR GE black B3DR SW Push Buttons illuminated red B3DL RT markable green B3DL GN blue B3DL BL yellow B3DL GE white B3DL WS Push Buttons illuminated, maintained red B3DLR RT markable green B3DLR GN blue B3DLR BL yellow B3DLR GE white B3DLR WS Rotary Knob 1) maintained B3KN2 maintained B3KN3 spring return B3KN1 BC3D RT BC3D GN BC3D BL BC3D GE BC3D SW BC3DR RT BC3DR GN BC3DR BL BC3DR GE BC3DR SW BC3DL RT BC3DL GN BC3DL BL BC3DL GE BC3DL WS BC3DLR RT BC3DLR GN BC3DLR BL BC3DLR GE BC3DLR WS BC3KN2 BC3KN3 BC3KN1 BS3D RT 10 BS3D GN 10 BS3D BL 10 BS3D GE 10 BS3D SW 10 BS3DR RT 10 BS3DR GN 10 BS3DR BL 10 BS3DR GE 10 BS3DR SW 10 BS3DL RT 10 BS3DL GN 10 BS3DL BL 10 BS3DL GE 10 BS3DL WS 10 BS3DLR RT 10 BS3DLR GN 10 BS3DLR BL 10 BS3DLR GE 10 BS3DLR WS 10 BS3KN2 10 BS3KN3 10 BS3KN1 10 Key Operated Rotary Switch 1) maintained B3SAR 0 BC3SAR 0 BS3SAR 0 1 key removable in position 0 maintained B3SARR 0 BC3SARR 0 BS3SARR 0 1 spring return B3SATT 0 BC3SATT 0 BS3SATT 0 1 Double Push Buttons 1) grün / rot B3DT G/R with white indicator lamp, weiß / schwarz B3DT W/S lamp max. 1,9 W grün-i / rot-0 B3DT GI/R0 weiß-i /schwarz-0 B3DT WI/S0 1) protection degree IP65 BC3DT G/R BC3DT W/S BC3DT GI/R0 BC3DT WI/S0 BS3DT G/R 10 BS3DT W/S 10 BS3DT GI/R0 10 BS3DT WI/S0 10 EMERGENCY STOP Ø40mm release by turning BS3P34 RT-0 10 pull to release, according to EN418 BS3P44 RT 10 release by key, according to EN418 BS3P44S3 1 Yellow Disk Ø70 mm (markable) B Connector for panel width 0,5-4mm snap-on mounting B3S 10 Connector for panel width 1-6mm screw mounting B3M 10 Contact Blocks max. 690V~ 1 NC B3T NO B3T10 10 Lamp holder max. 415V~ Socket: BA9s B3F for all kind of lamps 12
13 Lens Caps, Lamps and Accessories colour Type Lens Caps markable red B3RF RT 10 green B3RF GN 10 blue B3RF BL 10 yellow B3RF GE 10 white B3RF WS 10 Lens Caps with Fresnell Lense red B3R RT 10 for high intensity green B3R GN 10 blue B3R BL 10 yellow B3R GE 10 white B3R WS 10 LED-Lamps, 10 years lifetime, Socket BA9S Lamp voltage for lens caps Power consumption Type 20-30V AC/DC red 0,4W B3-L24 RTB V AC/DC green 0,4W B3-L24 GNB V AC/DC blue 0,4W B3-L24 BLB V AC/DC yellow 0,4W B3-L24 GEB V AC/DC white 0,4W B3-L24 WSB V AC/DC red 0,9W B3-L230 RTB V AC/DC green 0,9W B3-L230 GNB V AC/DC blue 0,9W B3-L230 BLB V AC/DC yellow 0,9W B3-L230 GEB V AC/DC white 0,9W B3-L230 WSB 50 Glow-discharged Lamps V AC red yellow, white 0,3W B4-GL230K V AC green 0,3W B4-GL230G 100 Filament Lamps 24V AC/DC all 1,2W B4-G V AC/DC all 1,2W B4-G48 50 Monoblock Multi-LED Ø22,5mm, IP65 Power Lamp voltage colour consumption Type 20-30V AC/DC red 0,4W B3-MB24 RTB V AC/DC green 0,4W B3-MB24 GNB V AC/DC blue 0,4W B3-MB24 BLB V AC/DC yellow 0,4W B3-MB24 GEB V AC/DC white 0,4W B3-MB24 WSB V AC red 4W B3-MB230 RTB V AC green 4W B3-MB230 GNB V AC blue 4W B3-MB230 BLB V AC yellow 4W B3-MB230 GEB V AC white 4W B3-MB230 WSB 10 Accessories Type Specification Description Wrench for mounting of J actuators, monoblocks, lens caps B3.. and Cam Switches with single hole mounting Lamp Installer used to install or replace B lamps BA9S Hole Plug grey B3-DU GR 10 for unused fixing holes Ø22,5mm Sealing Cover Protection against coarse P contamination, petrol-resitant, ambient temperature 0 o o C 13
14 Assembled Stations, IP67 Knockout entries M20, up, left and right. Built-in contact blocks and lamp holders for base mounting (snapped into the rear shroud). Other combinations on request. Type Enclosure Enclosure - 1 unit BG1 1 Enclosure - 2 units BG2 1 Enclosure - 3 units BG3 1 Push Buttons and Pilot Lights in Enclosures ON push button, green BG10 GN 1 OFF push button, red BG10 RT 1 Pilot light green Pilot light red BG01 GN 1 BG01 RT 1 Key operated 0 - I BG10SAR 0 1 Lock Ronis R455 Key operated I II BG10SARR 0 1 Lock Ronis R455 2 push buttons OFF - ON BG I 2 push buttons Up - Down BG20PF 1 with symbols 3 push buttons Up Down BG30PF 1 with symbols 0 3 push buttons I II BG push buttons OFF - ON BG21 GN 1 with pilot light green EMERGENCY STOP button unlock by turning mushroom button Ø 40mm EMERGENCY STOP button according to EN418 unlock by pull EMERGENCY STOP button eaccording to EN418 unlock by key EMERGENCY STOP button unlock by turning mushroom button Ø 70mm Foot and Palm button grey mushroom button Ø 70mm BG10P BG10P BG10P44S BG10P34P-11 1 BG10P14P GR 1 14
15 Emergency - Stop - Main Switch, lockable AC21 AC23 Plate Type 690V 3x400V 3-pole, Panel mounting, 4-Hole mounting, IP65 20A 25A 32A 40A 63A 100A 7,5kW 64 LTS20 EHN4 A3 1 10kW 64 LTS25 EHN4 A3 1 12,5kW 64 LTS32 EHN4 A3 1 16kW 64 LTS40 EHN4 A3 1 22kW 64 LTS63 EHN4 A3 1 22kW 64 LTS80 EHN4 A3 1 30kW 64 LT80 EHN34 T kW 64 LT100 EHN34 T pole, Panel mounting, 4-Hole mounting, IP65 20A 25A 32A 40A 63A 100A 7,5kW 64 LTS20 EHN4 A4 1 10kW 64 LTS25 EHN4 A4 1 12,5kW 64 LTS32 EHN4 A4 1 16kW 64 LTS40 EHN4 A4 1 22kW 64 LTS63 EHN4 A4 1 22kW 64 LTS80 EHN4 A4 1 30kW 64 LT80 EHN34 T kW 64 LT100 EHN34 T pole, for Installation board, 60mm, IP40 20A 25A 32A 40A 63A 100A 7,5kW 52x45 LTS20 SMAHN1 A3 1 10kW 52x45 LTS25 SMAHN1 A3 1 12,5kW 52x45 LTS32 SMAHN1 A3 1 16kW 52x45 LTS40 SMAHN1 A3 1 22kW 52x45 LTS63 SMAHN1 A3 1 22kW 52x45 LTS80 SMAHN1 A3 1 30kW 70x45 LT80 SMAHN1 T kW 70x45 LT100 SMAHN1 T pole, for Installation board, 60mm, IP40 20A 25A 32A 40A 63A 100A 7,5kW 52x45 LTS20 SMAHN1 A4 1 10kW 52x45 LTS25 SMAHN1 A4 1 12,5kW 52x45 LTS32 SMAHN1 A4 1 16kW 52x45 LTS40 SMAHN1 A4 1 22kW 52x45 LTS63 SMAHN1 A4 1 22kW 52x45 LTS80 SMAHN1 A4 1 30kW 70x45 LT80 SMAHN1 T kW 70x45 LT100 SMAHN1 T400 1 Net Changeover Switches for emergency power systems AC21 690V AC23 Plate Type 3x400V 4-pole, for Installation board, 60mm, IP40 NEW Other designs on request 20A 25A 32A 40A 63A 7,5kW 97x45 LTS20 SMA U kW 97x45 LTS25 SMA U ,5kW 97x45 LTS32 SMA U kW 97x45 LTS40 SMA U kW 126x45 LTS63 SMA U kW 126x45 LTS80 SMA U
16 Emergency - Stop - Main Switch, lockable, IP65 AC21 AC23 Plate Type 690V 3x400V 3-pole, Base mounting with Door Clutch * 20A 25A 32A 40A 63A 7,5kW 64 LTS20 VZVHN4 A3 1 10kW 64 LTS25 VZVHN4 A3 1 12,5kW 64 LTS32 VZVHN4 A3 1 16kW 64 LTS40 VZVHN4 A3 1 22kW 64 LTS63 VZVHN4 A3 1 Single-Hole mounting, Ø 22,5 mm..vzv.. 22kW 64 LTS80 VZVHN4 A3 1 4-Hole mounting..v.., 30kW 64 LT80 VHN34 T A 37kW 64 LT100 VHN34 T pole, Base mounting with Door Clutch * 20A 25A 32A 40A 63A 7,5kW 64 LTS20 VZVHN4 A4 1 10kW 64 LTS25 VZVHN4 A4 1 12,5kW 64 LTS32 VZVHN4 A4 1 16kW 64 LTS40 VZVHN4 A4 1 22kW 64 LTS63 VZVHN4 A4 1 Single-Hole mounting, Ø 22,5 mm..vzv.. 22kW 64 LTS80 VZVHN4 A4 1 4-Hole mounting..v.. 30kW 64 LT80 VHN34 T A 37kW 64 LT100 VHN34 T400 1 Add-on Switching Pole, attachable to 3- and 4-pole LTS.. Switches Base mounting Type Panel Installation board for Switches: mounting Maintainance LTS20.., LTS25.., LTS32.., LTS40 yes no N40E 1 LTS63.., LTS80.. yes no N80E 1 LTS20.., LTS25.., LTS32.., LTS40 no yes N40V 1 LTS63.., LTS80.. no yes N80V 1 Auxiliary Contact Block 1NO + 1NC, attachable to LTS.. and LT.. Switches, compatible electronic signal LTS20 - LTS80 yes yes LH11 1 LT80..., LT yes no LTY-E11 1 LT80..., LT no yes LTY-V11 1 * Depth T / X (Deviations from the Standard dimensions have to be indicated by order, max. 380 mm) dimensions X dimensions T Standard dimensions (mm) Type X Type T / X LTS20 VZV LTS63 VZV (X) LTS25 VZV LTS80 VZV (X) LTS32 VZV LT80 V (T) LTS40 VZV LT100 V (T) 16
17 Main Switches, lockable, IP65 AC21 AC23 Plate Type 690V 3x400V 3-pole, Panel mounting, 4-Hole mounting 20A 25A 32A 40A 63A 100A 7,5kW 64 LTS20 EH4 A3 1 10kW 64 LTS25 EH4 A3 1 12,5kW 64 LTS32 EH4 A3 1 16kW 64 LTS40 EH4 A3 1 22kW 64 LTS63 EH4 A3 1 22kW 64 LTS80 EH4 A3 1 30kW 64 LT80 EH34 T kW 64 LT100 EH34 T pole, Panel mounting, 4-Hole mounting 20A 25A 32A 40A 63A 100A 7,5kW 64 LTS20 EH4 A4 1 10kW 64 LTS25 EH4 A4 1 12,5kW 64 LTS32 EH4 A4 1 16kW 64 LTS40 EH4 A4 1 22kW 64 LTS63 EH4 A4 1 22kW 64 LTS80 EH4 A4 1 30kW 64 LT80 EH34 T kW 64 LT100 EH34 T pole Maintainance and Safety Switch, in plastic enclosure, UV-protected, sealable, lockable, IP65 PE PE 20A 25A 32A 40A 63A 100A 7,5kW 64 LTS20 PFHN4 A3 1 10kW 64 LTS25 PFHN4 A3 1 12,5kW 64 LTS32 PFHN4 A3 1 16kW 64 LTS40 PFHN4 A3 1 22kW 64 LTS63 PFHN4 A3 1 22kW 64 LTS80 PFHN4 A3 1 30kW 64 LT80 PFHN34 T kW 64 LT100 PFHN34 T pole Maintainance and Safety Switch, in plastic enclosure, UV-protected, sealable, lockable, IP65 PE PE 20A 25A 32A 40A 63A 100A 7,5kW 64 LTS20 PFHN4 A4 1 10kW 64 LTS25 PFHN4 A4 1 12,5kW 64 LTS32 PFHN4 A4 1 16kW 64 LTS40 PFHN4 A4 1 22kW 64 LTS63 PFHN4 A4 1 22kW 64 LTS80 PFHN4 A4 1 30kW 64 LT80 PFHN34 T kW 64 LT100 PFHN34 T pole... on request 17
18 Cam Switches for Panel mounting, 4-Hole mounting, IP65 Pole AC21 Motor Plate Type I th 3x400V ON-OFF-Switches 1 20A - 48 M10H E A1+G A - 48 M20 E A1+G A - 48 M10H E A2+G A - 48 M20 E A2+G A 5,5kW 48 M10H E A3+G A 11kW 48 M20 E A3+G A 15kW 64 N33F E A3+G A 5,5kW 48 M10H E A4+G A 11kW 48 M20 E A4+G A 15kW 64 N33F E A4+G2 1 Changeover Switches with 0-Position 1 20A - 48 M10H E U1+G A - 48 M20 E U1+G A - 48 M10H E U2+G A - 48 M20 E U2+G A 5,5kW 48 M10H E U3+G A 11kW 48 M20 E U3+G A 15kW 64 N33F E U3+G2 1 Changeover Switches without 0-Position 1 20A - 48 M10H E W1+G A - 48 M20 E W1+G A - 48 M10H E W2+G A - 48 M20 E W2+G2 1 Reversing Switch 3 20A 5,5kW 48 M10H E WU3+G2 1 Voltmeter Selector Switch, 3 line voltages, 3 phase voltages 20A - 48 M10H E V1+G2 1 Ammeter Selector Switch 1 20A - 48 M10H E M31+G2 1 18
19 Cam Switches for Panel mounting, 4-Hole mounting, IP65 Pole AC21 Motor Plate Type I th 3x400V Start-Switch with spring return 1 20A - 48 M10H E SE+G2 1 Stop-Switch with spring return 1 20A - 48 M10H E SA+G2 1 Gang Switches 1-pole 1 20A - 48 M10H E GR11+G A - 48 M20 E GR11+G2 1 3 Step Switches without 0-Position 1 20A - 48 M10H E ST31+G A - 48 M20 E ST31+G2 1 4 Step Switches without 0-Position 1 20A - 48 M10H E ST41+G A - 48 M20 E ST41+G2 1 2 Step Switches with 0-Position 1 20A - 48 M10H E ST021+G A - 48 M20 E ST021+G2 1 3 Step Switches with 0-Position 1 20A - 48 M10H E ST031+G A - 48 M20 E ST031+G2 1 19
20 Cam Switches, Single Hole mounting Ø 22,5 mm, IP65 Pole AC21 Motor Plate Type I th 3x400V ON-OFF-Switches 1 20A - 48 M10H Z A1+G A - 48 M20 Z A1+G A - 48 M10H Z A2+G A - 48 M20 Z A2+G A 5,5kW 48 M10H Z A3+G A 11kW 48 M20 Z A3+G A 5,5kW 48 M10H Z A4+G A 11kW 48 M20 Z A4+G2 1 Changeover Switches with 0-Position 1 20A - 48 M10H Z U1+G A - 48 M20 Z U1+G A - 48 M10H Z U2+G A - 48 M20 Z U2+G A 5,5kW 48 M10H Z U3+G A 11kW 48 M20 Z U3+G2 1 Changeover Switches without 0-Position 1 20A - 48 M10H Z W1+G A - 48 M20 Z W1+G A - 48 M10H Z W2+G A - 48 M20 Z W2+G A 5,5kW 48 M10H Z W3+G A 11kW 48 M20 Z W3+G2 1 Reversing Switch 3 20A 5,5kW 48 M10H Z WU3+G2 1 Voltmeter Selector Switch, 3 line voltages, 3 phase voltages 20A - 48 M10H Z V1+G2 1 Ammeter Selector Switch 1 20A - 48 M10H Z M31+G2 1 20
21 Cam Switches, Single Hole mounting Ø 22,5 mm, IP65 Pole AC21 Motor Plate Type I th 3x400V Start-Switch with spring return 1 20A - 48 M10H Z SE+G2 1 Stop-Switch with spring return 1 20A - 48 M10H Z SA+G2 1 3 Step Switches without 0-Position 1 20A - 48 M10H Z ST31+G A - 48 M20 Z ST31+G2 1 4 Step Switches without 0-Position 1 20A - 48 M10H Z ST41+G A - 48 M20 Z ST41+G2 1 2 Step Switches with 0-Position 1 20A - 48 M10H Z ST021+G A - 48 M20 Z ST021+G2 1 3 Step Switches with 0-Position 1 20A - 48 M10H Z ST031+G A - 48 M20 Z ST031+G2 1 ON-OFF-Switches Key operated Lock Ronis R A - 48 M10H Z A1+SA A - 48 M20 Z A1+SA A - 48 M10H Z A2+SA A - 48 M20 Z A2+SA A 5,5kW 48 M10H Z A3+SA A 11kW 48 M20 Z A3+SA 1 21
22 Cam Switches for Installation boards, 60mm Pole AC21 Motor Plate Type I th 3x400V ON-OFF-Switches 1 20A - 52x45 M10H SMA A A - 52x45 M20 SMA A A - 52x45 M10H SMA A A - 52x45 M20 SMA A A 5,5kW 52x45 M10H SMA A A 11kW 52x45 M20 SMA A A 5,5kW 52x45 M10H SMA A A 11kW 52x45 M20 SMA A4 1 Changeover Switches with 0-Position 1 20A - 52x45 M10H SMA U A - 52x45 M10H SMA U A - 52x45 M20 SMA U A - 52x45 M10H SMA U3 1 Changeover Switches without 0-Position 1 20A - 52x45 M10H SMA W A - 52x45 M10H SMA W A - 52x45 M20 SMA W2 1 3 Step Switches without 0-Position 1 20A - 52x45 M10H SMA ST A - 52x45 M20 SMA ST Step Switches without 0-Position 1 20A - 52x45 M10H SMA ST A - 52x45 M20 SMA ST Step Switches with 0-Position 1 20A - 52x45 M10H SMA ST A - 52x45 M20 SMA ST Step Switches with 0-Position 1 20A - 52x45 M10H SMA ST A - 52x45 M20 SMA ST031 1 Voltmeter Selector Switch, 3 line voltages, 3 phase voltages 20A 52x45 M10H SMA V1 1 ON-OFF-Switches Key operated Lock Willenhal FT A - 52x45 M10H SMA A1+SA A - 52x45 M20 SMA A1+SA A - 52x45 M10H SMA A2+SA A - 52x45 M20 SMA A2+SA A 5,5kW 52x45 M10H SMA A3+SA A 11kW 52x45 M20 SMA A3+SA 1 22
23 Cam Switches, Plastic enclosured, IP40 (IP65 on request) Pole AC21 Motor Plate Type I th 3x400V ON-OFF-Switches 20A 1 20A - 48 M10 P A1+G A - 48 M10 P A2+G A 5,5kW 48 M10 P A3+G2 1 ON-OFF-Switches 32A PE 3 32A - 48 LTS32 PF A3 1 PE PE 4 32A - 48 LTS32 PF A4 1 PE Heating EMERGENCY STOP Switch, 2-pole with red Handle 2 20A - 48 M10 P A G3 1 Changeover Switches with 0-Position 1 20A - 48 M10 P U1+G A - 48 M10 P U2+G A - 64 N20 P U2+G A 5,5kW 48 M10 P U3+G A 11kW 64 N20 P U3+G2 1 Star-Delta-Switch 3 32A 15kW 64 N20 P SD+G2 1 Reversing Switch with reciprocally spring return 3 20A 5,5kW 48 M10 P WU3R2+G2 1 ON-OFF-Switches Key operated Lock Willenhal FT A - 48 M10 P A1+SA A - 64 N20 P A1+SA A - 48 M10 P A2+SA A - 64 N20 P A2+SA A 5,5kW 48 M10 P A3+SA A 11kW 64 N20 P A3+SA 1 23
24 Mini-Cam Switches, Single Hole mounting Ø16 and 22,5mm,, IP65 Pole AC21 Motor Plate Type I th 3x400V ON-OFF-Switches 1 10A - 30 M4H Z A A - 30 M4H Z A A - 30 M4H Z A3 1 Changeover Switches with 0-Position 1 10A - 30 M4H Z U A - 30 M4H Z U A - 30 M4H Z U3 1 Changeover Switches with 0-Position, plate HAND AUTO 1 10A - 30 M4H Z U A - 30 M4H Z U A - 30 M4H Z U Changeover Switches without 0-Position 1 10A - 30 M4H Z W A - 30 M4H Z W A - 30 M4H Z W3 1 Start-Switch with spring return 1 10A - 30 M4H Z SE 1 24
Low Voltage Control Gear
Low Voltage Control Gear Made in Short Form Catalogue D651E081 Technical catalogues under: www.benedict.at Contactors Motor-Starter Mini-Contactors Contactors Overload Relays Capacitor Switching Contactors
More informationIndex. Actuators and Lens Caps. Page. Overview 22mm 2. Push Buttons 3 EMERGENCY STOP Buttons 4 Key Operated Rotary Switches 4
Index Actuators and Lens Caps Page Overview 22mm 2 Push Buttons 3 EMERGENCY STOP Buttons 4 Key Operated Rotary Switches 4 Rotary Knobs and Swing Knobs 5 Illuminated Rotary Knobs and Swing Knobs 5 Illuminated
More informationProgram B3 318 Ø 22,5mm. Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320
Push Buttons Index Page Program B3 318 Ø 22,5mm Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320 Rotary Knobs and Swing Knobs 321 Illuminated Rotary Knobs and Swing Knobs 321
More informationPage. Program B3 2. Ø 22,5mm. Push Buttons 3 EMERGENCY STOP Buttons 4 Key Operated Rotary Switches 4
Push Buttons Page Program B3 2 Ø 22,5mm Push Buttons 3 EMERGENCY STOP Buttons 4 Key Operated Switches 4 Knobs and Knobs 5 Illuminated Knobs and Knobs 5 Illuminated Push Buttons 6 Double Push Buttons 6
More informationPush Buttons. Quality made in Austria
Push Buttons Quality made in Austria Page Ø 22,5mm Programm B3 2 Push Buttons 3 EMERGENCY STOP Buttons 4 Key Operated Switches 4 Knobs and Knobs 5 Illuminated Knobs and Knobs 5 Illuminated Push Buttons
More informationProgram B3 330 Ø 22,5mm. Push Buttons 331 EMERGENCY STOP Buttons 332 Key Operated Rotary Switches 333
Index Page Program B3 330 Ø 22,5mm Push Buttons 331 EMERGENCY STOP Buttons 332 Key Operated Rotary Switches 333 Rotary Knobs and Swing Knobs 333 Illuminated Rotary Knobs and Swing Knobs 334 Illuminated
More informationPush Buttons. Pushing the boundaries
Push Buttons Pushing the boundaries Page Program B3 2 Ø 22,5mm Push Buttons 3 EMERGENCY STOP Buttons 4 Key Operated Switches 4 Knobs and Swing Knobs 5 Illuminated Knobs and Swing Knobs 5 Illuminated Push
More informationGeneral Informations 2 Technical data 3 Basic designs 4-8
Contents Page General Informations 2 Technical data 3 Basic designs 4-8 Cam Switches On-Off switches, Changeover switches 9-12 Star-Delta switches 13-15 Multi speed switches 16-20 Control switches 21-23
More informationProgram B3 318 Ø 22,5mm. Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320
Push Buttons Index Page Program B3 318 Ø 22,5mm Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320 Rotary Knobs and Swing Knobs 321 Illuminated Rotary Knobs and Swing Knobs 321
More informationProgram B3 318 Ø 22,5mm. Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320
Push Buttons Index Page Program B3 318 Ø 22,5mm Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320 Rotary Knobs and Swing Knobs 321 Illuminated Rotary Knobs and Swing Knobs 321
More informationType12. Push Buttons Mounting hole Connectors Connectors Ø 22,5mm. with key way. without key way. page 4. page 10
cuators and Lens Caps 22mm IP67 (IP65), 12 Push Buttons Mounting hole Connectors Connectors Ø 22,5mm Lamp Holders page 3 with key way IP65 without key way page 5,6 EMERGENCY STOP Buttons ctuator insert
More informationMOTOR PROTECTION CIRCUIT BREAKERS
MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm
More informationIMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp
IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5
More informationsirius Switching. Protecting. Starting. SIRIUS Product Overview
sirius Switching. Protecting. Starting. SIRIUS Product Overview S00 Design Direct-on-line starting Reversing duty Assembly kit for busbar mounting 0 mm: RA9 -C 0 mm: RA9 -D Consisting of: wiring kit busbar
More informationApproved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.
Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit
More information3RV1 Circuit-Breakers
SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a
More informationApproved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.
Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit
More informationSwitches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors
6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or
More informationMini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks
Mini Contactors Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 24 Mini Contactors
More informationSwitch Disconnectors, Main and EMERGENCY-STOP Switches
General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)
More informationMotor protection circuit breakers
Wide adjustment range 0. to 00A IEC breaking capacity Icu 50kA (400V) up to 00A Suitable for isolation Comprehensive line of accessories Magnetic-only version Automatic trip indicators High reliability
More informationContactors and Contactor Assemblies
Contactor Industrial Controls Product Catalog 07 Section c o n t e n t s Section Overview / - /5 Product Overview /6 - /7 Contactors 3RT0, 3-pole to 95 /8 3RT0, 3-pole to 500 /9 3RT, 3-pole Vacuum to 500
More information3RA13, 3RA14 Contactor Assemblies
RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock
More informationIDE Load break switches for machine control Remotely trippable switch from 32 to 160 A
The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct
More informationJ7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1
Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload
More informationIEC Contactors. Auxiliary Contact Blocks GENERAL
IEC Contactors Auxiliary Contact Blocks GENERAL Description 3RH19 Auxiliary contact blocks The 3RH19 auxiliary contact blocks are available in 1, 2, 3 and 4-pole front mount versions and 2-pole side mount
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More informationContactors and Contactor Assemblies
RT contactors, size S00 The product range at a glance The new generation is a complete, modular system family, logically designed right down to the last detail, from the basic units to the accessories.
More informationIEC Power Control Contactors and Contactor Assemblies
IEC Power Control Contactors and Contactor ssemblies Contents Pages Contents Pages Section Overview......................... / - /5 Product Overview......................... /6 - /7 Contactors 3RT0 / 3RT0,
More information3RT, 3TB, 3TF Contactors for Switching Motors
RT, TB, TF Contactors for Switching Motors Overview RT contactors and coupling relays Size S00 with mountable accessories The SIRIUS generation of controls is a complete, modular system family, logically
More informationEnclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐. Non-Metallic Type 1/12K/IP66 Enclosure (KS7-C0C4R)
KWIKstarter/CX7 CX7 Non-Reversing Combination Controller, AC Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ Catalog Number ➍➏➑➒ ~ ~ ~ ~ 0.10 0.16 2.1 1 CX7-9-10- -AS0.16A-A10-PG
More informationMini contactors. K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. a.c. control contactors (1)
K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. c LC-K060ii a.c. control contactors () Standard power ratings Rated Type of Instantaneous Basic reference.
More informationProtection Equipment
Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data
More informationMOTOR & CIRCUIT PROTECTION
2 MOTOR & CIRCUIT PROTECTION Motor Protection Circuit Breakers p2-1 Motor Protection Relays p2-13 Thermistor Protection Relay p2-18 Fuse Holders p2-20 Miniature Circuit Breakers p2-23 Residual Current
More informationEnclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ (KS7-C0C4R) Discount Schedule F-1
KWIKstarter/CX7 CX7 Non-Reversing Combination Controller, AC Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ ~ ~ ~ ~ 0.10 0.16 2.1 1 CX7-9-10- -AS0.16A-A10-PG 551 Q4 ~
More informationIndicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green
22.5 mm 3.5 mm IP65 1 A 66 VAC Choose one component from each of the coloured sections to assemble a complete switch. For other options or further information please contact your local sales office. INDICATOR
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationMini Contactors & Overloads
108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationPush buttons and selectors
Accessories and spare parts 8 LM2T A130 8 LM2T A140 8 LM2T A185 8 LM2T AL... Order code Description Qty per Wt 8 LM2T A12❶ Coloured diffuser for 10 0.001 double touch buttons 8 LM2T A130 Threaded plug
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More informationPushbuttons, Switches and Pilot Devices
Technical information Command auxiliaries Rated insulation voltage Ui IEC97-5-1 V 600 Rated thermal current Ithe IEC97-5-1 A Rated operating current IEC97-5-1/EN6097-5-1 Category AC15 Ie 2 V A 6 00 V A
More informationSiemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.
3RA Fuseless Compact Starters Catalog News LV 1 N April 2008 SIRIUS www.siemens.com/lowvoltage 3RA Fuseless Compact Starters General data Overview 3RA fuseless compact starters and infeed system for 3RA
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationSiemens AG Highly flexible system-based switching, protecting and starting. SIRIUS Modular System. Answers for industry.
Siemens AG 00 Highly flexible system-based switching, protecting and starting. SIRIUS Modular System SIRIUS Answers for industry. Everything for the electrical cabinet: SIRIUS Modular System. Press Shop
More information1 - Control and signalling units
Contents 0 - Control and signalling units Selection guide..............................................page /2. Control and signalling units Ø 8 et 2 b LED pilot lights, type XVL A...................................
More informationM C. Ex d M-0... control, monitoring and signalling devices
Ex d M-0... control, monitoring and signalling devices M-0 M-0 series control, monitoring and signalling devices are installed as external accessories on Cortem 'Ex d' enclosures used in any industrial
More informationSentron 3VT circuit breakers Simply Smart: First choice for power distribution
s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case
More informationK1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm
Characteristics cam voltmeter switch - 3L and 3L-N - 60-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationTeSys contactors From 115 to 2750 A
Selection guide From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting, cos j rectification,
More informationControl Units Ex e in Stainless Steel LCS*.*
Features Assembly Stainless steel enclosures Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex de and Ex tb Up to 4 operators per control unit, base-mounted contact blocks Wide choice of operators,
More information05/029. RMQ Titan Standard Legend Plates, Insert Plates Go to: List
RMQ Titan Standard Legend Plates, Insert Plates 05/029 Standard legend plates 30 x 50 mm, round, Type 0 I M22S-ST-X88 216485 0 I M22S-ST-X89 218147 I 0 II M22S-ST-X93 216486 STOP M22S-ST-GB0 216494 START
More informationCat. No. 800B-EPA 800B-EPB 800B-EPC 800B-EPD. Cat. No. 800B-ALB4. Cat. No.
Bulletin B mm Push Buttons Product Overview/Specifications Bulletin B mm Push Buttons Designed to worldwide standards (UL, CSA, CE, and CCC) Durable materials Operators are made of corrosion-proof plastic
More informationSafety Systems Safety Integrated
3SE2 / SE3 Molded plastic /metal enclosure with separate actuator Application Safety interlock switches with separate actuator are used where the position of doors, covers or safety screens must be monitored
More informationSeries Panel Mounted Control Devices
E_Master2012.qxd:NEW_E_Master_temp.qxd 1/27/12 4:28 PM Page 1 Series Features: Suitable for hazardous and corrosive locations. Installation is easy and precise. Devices fit into a standard 30.5mm, 1.2"
More informationSystem-based switching, protecting, starting. SIRIUS Modular System. sirius
System-based switching, protecting, starting. Modular System. sirius Everything for the electrical cabinet: Modular System. Contents S00 structure S00 selection and ordering data: Circuit breakers, contactors,
More information3SU11 complete units 5
5 5.1 Product description The 3SU11 complete units are a modular range of devices for front plate mounting and rear cable connection. Complete units made up of an actuating or signaling element and contact
More informationExercise 1-4. Contactors and Control Relays EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION
Exercise 1-4 Contactors and Control Relays EXERCISE OBJECTIVE Identify the characteristics of control relays and contactors. DISCUSSION OUTLINE The Discussion of this exercise covers the following points:
More informationSystem-based switching, protecting, starting. SIRIUS Modular System. sirius
System-based switching, protecting, starting. Modular System. sirius Everything for the electrical cabinet: Modular System. Contents S00 structure S00 selection and ordering data: Circuit breakers, contactors,
More informationMODULES FOR SAFETY AND MONITORING
MODULES FOR SAFETY AND MONITORING Woertz AG Hofackerstrasse 47, P.O. Box 948, CH-43 Muttenz, Switzerland Tel. ++4 6 / 466 33 33, Fax ++4 6 / 46 96 06 http://www.woertz.ch Woertz-USA 5 Discovery Drive,
More informationContactors and Contactor Assemblies
SIRIUS Contactors and Contactor Assemblies Application WYE-delta starting can only be used either if the motor normally operates in a d (delta) connection or starts softly or if the load torque during
More information4XDOLW\ &RPPLWPHQW.
www.tier1automation.com Since 1984, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced
More information63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.
comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power
More information74 PS range Push-buttons, selectors and indicators Ø 22mm
74 PS range Push-buttons, selectors and indicators Ø 22mm Push-buttons, selectors, indicators and 22mm diameter pre-drilled technopolymer enclosures. Ideal for the creation of signalling and control units
More informationMotor Control Products Selection Guide
MKING MODERN LIVING POSSIBLE Motor Control Products Selection Guide Contactors, Relays, and Circuit Breakers www.danfoss.com/ia c o n t e n t s Minicontactors CI 5 Thermal Overload Relays TI 9C for Minicontactors
More informationK1D004ACH cam switch - 4-pole A - for Ø 22 mm
Characteristics cam switch - 4-pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing mode Cam
More informationpointofsale available at your local trade outlet
pointofsale available at your local trade outlet pointofsale products IP65 pushbuttons Ø22.5mm Contact rating @ 240V AC 10A Resistive (AC1), 6A (AC15) PB01C PB02C PB03C PB04C PB05C PB06C PB07C PB08C PB09C
More information16 Mm. Bulletin 800B 16 mm Push Buttons. Features. Operator Assembly Sequence. Push Button & Pilot Light Operators. Build a Catalog Number
16 Mm Bulletin 800B 16 mm Push Buttons Build a Catalog Number Features Designed to worldwide standards (UL, CSA, CE, and CCC) Durable materials Operators are made of corrosion-proof plastic to ensure long
More information194E FA 32 E P11 P11 6
Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable for padlocks) E-FA Painted Steel Enclosure
More information3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017
3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data
More informationPushbutton and selector switch series Quality touch!
Pushbutton and selector switch series Quality touch! For Info: sales@switchesunlimited.com www.switchesunlimited.com Phone: 00-1-07 Fax: 71-7-70 Pushbuttons and selector switches Ømm Quality touch! mm
More informationMiniature Circuit-Breaker IEC Series 8562
> 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationSolid State Remote Power Controller E /627
Solid State Remote Power Controller E--623/62 Description The E-T-A Solid State Remote Power Controllers E--623/62 are electronic control modules suitable for inductive loads such as electromagnetic valves
More informationThermal-Magnetic Circuit Breaker 2216-S
Thermal-Magnetic Circuit Breaker 226-S Description One and two pole thermal-magnetic circuit breaker in compact design with slide actuator, trip-free mechanism, various trip characteristics and optional
More informationSIGUARD Safety Systems Safety Integrated
SE 10 / SE. 00 / SE. 4 / SE. 5 Molded plastic / metal enclosure with separate actuator Application Safety interlock switches (limit switches) with separate actuator are used where the position of doors,
More informationAThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.
www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer
More informationLoad Disconnect Switches and Motor Switches
Load Disconnect Switches and Motor Switches 594 Load Disconnect Switches and Motor Switches Contents Load Disconnect Switches and Motor Switches Safety Switches made of Resin 10, 12/16, 16, 20, 25, 40,
More informationlow voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters
CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor
More informationMULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors
B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors
More informationLoad Feeders and Motor Starters for Use in the Control Cabinet
Load Feeders and Motor Starters for Use in the Control Cabinet Price groups 12W, 14O, 230, 241, 250, 260, 41B, 41D, 41E, 41L, 42C, 42D, 42F, 471, 4N1, 5K1, 5K2, 5N2, 764, 15, 16 /2 Introduction SIRIUS
More informationPushbutton Units and Indicator Lights
SIGNUM 3S3 Introduction Overview SIGNUM is a range of plastic and metal control devices for frontplate mounting and rear wire connection. SIGNUM is of modern industrial design with a very construction
More informationOVERLOAD RELAYS POWER & ACTUATION PROVEN. series
POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be
More informationK1D012ULH cam changeover switch - 2-pole A - screw mounting
Characteristics cam changeover switch - 2-pole - 90-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing
More informationResidual Current Devices drcm Digital
Digital Line voltage independent RCCB for fault or additional protection with additional digital features. System Monitoring: Preventive information / warning before the RCD trips in case of leakage currents.
More information22mm Non Illuminated Metal Operators
22mm 22mm Non Illuminated Metal Operators Altech Corp. can provide other push button and actuator options. If your requirement calls for a 22 mm operator which is not shown, please do not hesitate to call.
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG GERMANY This is to certify that representative samples of Motor Controllers, Magnetic (See following pages for additional
More informationMINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka)
MINIATURE CIRCUIT BREAKERS LPN UP TO 3 A (0 ka) For building, commercial and industrial installations up to 3 A 30/400 V a.c. and 0/440 V d.c. For protection of cables and conductors against overload and
More informationK1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm
Product data sheet Characteristics cam ammeter switch - 3 circuits - 90-12 A - for Ø 22 mm Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal
More informationMagnetically Actuated Safety Interlock Switches
Conforms to EN10, EN292, EN020-1 CSA and BG approved Actual Size Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic,
More informationK1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm
Characteristics body for BCD encoded output switch - 1 pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Sub-assembly
More informationControl relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO
Characteristics Environment Conforming to standards IEC/EN 0947-1, 0947-5-1, NF C 3-140, VDE 00 Approvals UL, CSA, DEMKO, NEMKO, SEMKO Vertical axis Horizontal axis Operating position 180 Without derating
More informationThermal-Magnetic Circuit Breaker 4220-T...
Thermal-Magnetic Circuit Breaker 40-T... Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 (5 ka), EN/IEC 60934 (6kA) and UL 077 (5 ka). With
More informationict contactors EN 61095, IEC 1095 Interference
ict contactors DB23399 DB669 DB06604 Country approval pictograms EN 6095, IEC 095 ict contactors are available in two versions: b Contactors without manually-operated b Contactors with manually-operated.
More informationExpansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157
PRODUCT DA TA SLC 150 110 Expansion Unit Catalog Nos. 1745-151, - 152, - 153, - 154, - 156, -E157 7 : The EXpdnSiQn Unit The SLC 150 expansion unit can be used with either the SLC 150 processor unit or
More informationSIMOCODE 3UF Motor Management and Control Devices
Technical specifications General data applicable to the basic units, current measuring modules, current/voltage measuring modules, expansion modules, decoupling module and operator panel Permissible ambient
More information1.4. Pushbuttons and Indicating Lights. Product Overview
Contents Product Overview Product Description The RMQ-6 pushbutton line offers a wide array of functional and attractively designed illuminated and non-illuminated pushbuttons, selector switches, emergency
More informationAccessory Kit for all Designs of Hand-held Pendant Station
Overview of accessories for hand-held pendant station kits Accessories for kit Suitable for all designs Hand-held pendant stations HBA/HBM Hand-held pendant stations HBL EMERGENCY- STOP device Pushbutton
More informationTeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters
Component parts for assembling reversing contactors for motor control or low speed - high speed starters For 3-pole motor reversing contactors using identical contactors 810373 Contactors with screw clamp
More informationLarge Frame IEC Contactors
Large Frame IEC Contactors Bulletin 100-E PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 1 Changing Applications for Contactors There are fewer and fewer traditional large motor starting
More information