Pilot operated 2 port solenoid valve (general purpose valve) 100 VAC 50/60Hz 110 VAC 60Hz 200 VAC 50/60Hz 220 VAC 60Hz 12 VDC 24 VDC 48 VDC 100 VDC
|
|
- Anis Wilkerson
- 5 years ago
- Views:
Transcription
1 D11/D1 Series (general purpose valve) D11/D1 Series NC (normally closed) type, NO (normally open) type Port size: Rc1/4 to Rc1 Diaphragm structure Refer to Ending 17 for more details. JIS symbol Common specifications D11: NC (normally closed) type Descriptions Standard specifications Working fluid ir, water, kerosene, oil (50 mm /s or less) OUT Working pressure differential range MPa 0.0 to 1.0 (Refer to max. working pressure differential on individual specifications.) Max. working pressure MPa IN Withstanding pressure (water) MPa Fluid temperature (Note 1) to 60 D1: NO (normally open) type mbient temperature 0 to 60 OUT eat proof class tmosphere Place free of corrosive gas and explosive gas Valve structure Pilot operated poppet, diaphragm structure IN Valve seat leakage (Note ) cm 3 /min. (NR) 0. or less (air) Mounting attitude Free (within working pressure differential range) ody/sealant ronze, nitrile rubber Note 1: No freezing Note : For D11 (NC (normally closed)), these values apply at pneumatic pressure 0.0 to 1.0 MPa, and for D1 (NO (normally open)), these apply at pneumatic pressure 0.0 to 0.5 MPa. Individual specifications Descriptions Min. working Max. working pressure diff. (MPa) pparent power (V) Power consumption (W) Port Orifice size pressure diff. ir Water, kerosene Oil (50 mm /s) Rated voltage olding Starting (mm) C DC (MPa) C DC C DC C DC 50z 60z 50z 60z 50/60z NC (normally closed) type D11 Rc1/ D11 Rc3/ * D1115 Rc1/ D110 Rc3/ D115 Rc NO (normally open) type D115 Rc1/ 15 D10 Rc3/ D15 Rc1 5 0 VC 50/60z 1 VC 60z 00 VC 50/60z 0 VC 60z 1 VDC 4 VDC 4 VDC 0 VDC *1: The types above apply up to the basic port size (Rc). Refer to ow to order for other combinations. *: Refer to DC column for maximum working pressure differential of coil with diode for D11. *3: Variation of rated voltage should be within %. *4: The values in ( ) in the power consumption DC column apply for the type with DIN terminal box. *5: The minimum working pressure differential for the port size (1/4) and (3/) is 0.05 MPa for fluoro rubber sealant / / / (.4) 15.5 (14) Mass (kg)
2 D11/D1 Series Optional specifications Sealant Coil (heat proof class) Fluid temperature (Note 1) mbient temperature Valve seat leakage (Note ) cm 3 /min. (NR) Note 1: No freezing Note : For D11 (NC (normally closed)), these values apply at pneumatic pressure 0.0 to 1.0 MPa, and for D1 (NO (normally open)), these apply at pneumatic pressure 0.0 to 0.5 MPa. Note 3: The range is 0 to 0 when using the square terminal box with light for the coil housing. Flow characteristics Fluoro rubber to 60 to 90 0 to 60 0 to 0 (Note 3) 0. or less (air) Port size Orifice (mm) NC (normally closed) type D11 Rc 1/ D11 Rc 3/ 0.19 D1115 Rc 1/ D110 Rc 3/4 0 D115 Rc 1 5 NO (normally open) type D115 Rc 1/ D10 Rc 3/4 0 D15 Rc 1 5 *1: Effective sectional area S and sonic conductance C are converted as S 5.0 x C. Flow characteristics C[dm 3 /(s bar)] b Cv flow factor S (mm ) N/ US/ F/ F/ FV FW/ F FL P/D PK/ DK For dry air Explosion proof V/ VL S/ SV NP/NP/ NVP C/ MX/ Other.P. systems PD/FD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order eneral purpose valve 47
3 D11/D1 Series ow to order D O 3 S C0V ctuation Port size E Coil housing Other options F Manual override (Locking) I Surge suppressor Mounting plate J Rated voltage Symbol Descriptions ctuation 1 NC (normally closed) type NO (normally open) type Port size N 1 / 4 3 / 1 / 3 / 4 1 C Type of screw C Type of screw Rc NPT D ody, sealant combination D ody, sealant ody Sealant Treat Remarks combination *1 O Nitrile rubber ir, water, kerosene, oil (up to 60 ) ronze * Fluoro rubber ir, kerosene, oil (up to 90 *1) *3 D Stainless Nitrile rubber ir, water, kerosene, oil (up to 60 ) E steel Fluoro rubber ir, kerosene, oil (up to 90 *1) Nitrile rubber ir, water, kerosene, oil (up to 60 ) ronze J Fluoro rubber ir, kerosene, oil (up to 90 *1) Oilprohibit L Stainless Nitrile rubber ir, water, kerosene, oil (up to 60 ) M steel Fluoro rubber ir, kerosene, oil (up to 90 *1) Std. Option D11 D1 Refer to page 36 in the introduction for details on the material combinations. E to J <Example 1 of model number> D11003C0V The combinations indicated with a Series : D11 ctuation : NC (normally closed) type Port size : Rc3/4 C Type of thread : Rc D ody, sealant combination : ody bronze, sealant nitrile rubber E Coil housing : Open frame lead wire F to : lank J Rated voltage :0 VC 50/60 z, 1 VC 60 z Refer to the following page for details on the coil housing, other options and voltage, etc. in the above table can be manufactured. <Example of model number> D115DCSC00V Series: D1 ctuation : NO (normally open) type Port size : Rc1/ C Type of thread : D ody, sealant combination : ody stainless steel, sealant nitrile rubber E Coil housing : rommet lead wire F Manual override (Locking) : Selected : lank I Surge suppressor : With surge suppressor J Rated voltage : 00 VC 50/60 z, 0 VC 60 z Note on model no. selection Note on (D) *1: (D): When selecting 4, 4K, 4. *: The stainless steel body is not available for () (port size) (1/4) or (3/). *3: The standard body material for the () (port size) (1/4) and (3/) is brass. 4
4 D11/D1 Series For (E) to (J), the combinations indicated with symbols can be manufactured. Note that if the (F) to (I) options are not required, no symbol is indicated. E Coil housing F Other options I J Rated voltage Cable gland Conduit Descriptions (Marine cable gland) (Conduit pipe) Descriptions 15a 15b 15c CTC 19 1 / 3 C E 3K 3 3P 3Q 4 4K 4 5 5K 5 5P 5Q C Std. Option Open frame lead wire rommet lead wire DIN terminal box (1/) DIN terminal box (Pg11) DIN terminal box + small light (Pg11) Open frame type Open frame type Open frame type (eat proof class ) (Diode integrated) Square terminal box (1/) Square terminal box + light (1/) Square terminal box (IP65 or equivalent) (1/) (1/) Square terminal box + light (IP65 or equivalent) Lead wire Square terminal box (1/) Square terminal box + light (1/) Lead wire Square terminal box Square terminal box + light Square terminal box (IP65 or equivalent) (1/) Square terminal box + light (IP65 or equivalent) (1/) Manual override (Locking) Mounting plate rommet lead wire 300 mm D E F D E F D E F Surge suppressor S S S S 0 VC, 00 VC, 1 VDC, 4 VDC, 4 VDC, 0 VDC 0 VC, 00 VC 0 VC, 00 VC, 1 VDC, 4 VDC, 4 VDC, 0 VDC 0 VC, 00 VC, 4 VDC 0 VC, 00 VC, 1 VDC, 4 VDC, 4 VDC, 0 VDC 0 VC, 00 VC, 4 VDC, 0 VDC 0 VC, 00 VC, 1 VDC, 4 VDC, 4 VDC, 0 VDC 0 VC, 00 VC, 4 VDC, 0 VDC 0 VC, 00 VC 0 VC, 00 VC Refer to the following precautions for (E) to (J). Conduit (CTC19) (1/) N/ US/ F/ F/ FV FW/ F FL P/D PK/ DK For dry air Explosion proof V/ VL S/ SV NP/NP/ NVP E DIN terminal box C/ MX/ K 3 4K 4 5K 5 3P 3Q 5P 5Q Open frame rommet lead wire 300 mm 4 (eat proof class ) 5 (Diode integrated) Open frame square terminal box 4K, 4 (eat proof class ) 5K, 5 (Diode integrated) Open frame square terminal box (IP65 or equivalent) 5P, 5Q (Diode integrated) Refer to page for coil selection. Note on model no. selection Note on (E) *4: 5, 5K, 5, 5P and 5Q are coils which convert C power to DC with a diode. *5: The DC power with DIN terminal box is not available for () (port size) (1/4) or (3/). *6: Port size (1/4) or (3/) cannot be mounted on the manual override ((F) ). Note on () to (I) *7: The mounting plate (() ) can be mounted only on the port size (1/4) and (3/). *: Select one among D, E, F, and for (). *9: The surge suppressor is an accessory for the lead wire coil. When using the coil with terminal box, the surge suppressor is mounted in the terminal box. *: Surge suppressor is incorporated in coil with diode and (E) 4 VDC coil as standard. *11: Tropic care treatment (rustproof coating) is available as a measure against rust. Note that the tropic care treatment is not available when the manual override option () is selected. Note on (J) *1: 0 VC coil is compatible with 0 VC 50/60 z,1 VC 60 z, and 00 VC coil is compatible with 00 VC 50/60 z, 0 VC 60 z. Note that (E) 5, 5K, 5, 5P, and 5Q coils are used only with 0 VC 50/60 z or 00 VC 50/60 z. *13: Consult with CKD about other than above voltage. *14: The lead wire is available in the standard 300 mm length, and 500 mm, 00 mm, 000 mm and 3000 mm lengths. Contact CKD for more information. 49 Other.P. systems PD/FD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order eneral purpose valve
5 D11/D1 Series Dimensions: D11 Series (Page 300) Open frame lead wire type D11/* Lead wire length 300 mm M5 Depth 1 CKD D11* Rc1/4 D11* Rc3/ *1: The dimensions are the same for the or NPT thread port size. Open frame lead wire type D1115/0/5* Lead wire length 300 mm 46 F CKD D E C D1115* D110* D115* C D E F Rc1/ Rc3/4 Rc1 *1: The dimensions are the same for the or NPT thread port size. 5
6 D11/D1 Series Optional dimensions: D11 Series (Page 300) rommet lead wire type D11 to 5* C J Lead wire length 300 mm K * Refer to open frame lead wire type dimensions on a left page for common dimensions. DIN terminal box D11 to 5* E L M (41) N N/ US/ F/ F/ FV FW/ F D11 to *C D1115 to 5*C J K Dimensions shown in ( ) are for the 1/. L M N D11/* C (50) 0.5 D1115 to 5* C (53.5) D1115 to 5* DC (54) FL P/D Open frame type + square terminal box D11 to 5* 3 K 4K 5 4 P Q N 61 Open frame type + conduit D11 to 5* Q PK/ DK For dry air Explosion proof V/ VL S/ SV NP/NP/ NVP 45 CTC19 (1/) C/ D11 to * D1115 to 5* P N 6 1 P 7 91 Dimensions shown in ( ) are for the 1/. Q D11 to 53(56) D1115 to 5 57(60) MX/ Other.P. systems PD/FD/ PJ CVE/ CVSE Manual override (locking) D1115/0/5*** Manual IN 61 OUT Mounting plate D11/*** CPE/ CPD Medical analysis Custom order eneral purpose valve OUT port Mounting plate: E0159 Port size 15 (1/) to 5 (1) mounting plate is not used. 53
7 D11/D1 Series Dimensions: D1 Series (Page 300) Open frame lead wire type D115/0/5* Lead wire length 300 mm 46 E F CKD D C *1: The dimensions are the same for the or NPT thread port size. C D D115* D10* D15* E F Rc1/ Rc3/4 Rc1 54
8 D11/D1 Series Optional dimensions: D1 Series (Page 300) rommet lead wire type D115/0/5* C Lead wire length 300 mm 3 * Refer to open frame lead wire type dimensions on a left page for common dimensions. DIN terminal box D115/0/5* E J K 39(41) N/ US/ F/ F/ FV FW/ F FL Dimensions shown in ( ) are for the 1/. Voltage C DC J K (53.5) (60) P/D Open frame type + square terminal box D115/0/5* 3 K 4K 5 4 P Q Open frame type + conduit D115 to 5* PK/ DK For dry air Explosion proof (60) V/ VL S/ SV NP/NP/ NVP C/ CTC19 (1/) Dimensions shown in ( ) are for the 1/. MX/ Other.P. systems PD/FD/ PJ CVE/ CVSE CPE/ CPD Manual override (locking) D115/0/5*** Medical analysis Custom order Manual (13) eneral purpose valve 55
9 D11/D1 Series Internal structure and main parts materials D11 Series IN OUT (Figure shows close on operating) No Parts name Core assembly Shading coil * Coil Plunger Plunger spring Valve spring Stuffing *3 Sealant Diaphragm assembly ody O ring Orifice plate *3 Material SUS405 or equivalent, SUS316L, SUS403*1 Cu (g when stainless steel body) SUS405 or equivalent CC407 (SCS13) NR (FKM) SUS303,, NR (SUS303,, FKM) CC407 (SCS13) *4 NR (FKM) Copper (silver when stainless steel body) ronze casting (stainless steel casting) Nitrile rubber (fluoro rubber or tetrafluoroethylene resin), nitrile rubber (stainless steel, fluoro rubber) ronze casting (stainless steel casting) Nitrile rubber (fluoro rubber or tetrafluoroethylene resin) Options are shown in ( ). *1: When the body and sealant material combination symbol is other than O or, the material is SUS405 or equivalent, SUS316L, SUS430. *: When using the DC coil or a coil with a diode, no shedding coil is used. *3: For port size (1/4) or (3/), stuffing and orifice plate are not available. *4: For port size (1/4) or (3/), the body material is C3771 (brass) as a standard. 50
10 D11/D1 Series Internal structure and main parts materials D1 Series N/ 1 US/ F/ F/ 3 FV 4 FW/ F FL 7 1 P/D IN OUT PK/ DK For dry air No Parts name Plunger/core assembly Shading coil Coil NO valve assembly Spring Valve spring Stuffing Sealant Diaphragm assembly ody O ring Orifice plate (Figure shows open on operating) Material SUS405 or equivalent, SUS316L, Cu (g when stainless steel body) POM/NR (SUS303, PF, FKM or PTFE) CC407 (SCS13) NR (FKM) SUS303,, NR (SUS303,, FKM) CC407 (SCS13) NR (FKM) Copper (silver when stainless steel body) cetyl resin, nitrile rubber (stainless steel, perfluoroalkoxy resin, fluoro rubber or tetrafluoroethylene resin). ronze casting (stainless steel casting) Nitrile rubber (fluoro rubber or tetrafluoroethylene resin), nitrile rubber (stainless steel, fluoro rubber) ronze casting (stainless steel casting) Nitrile rubber (fluoro rubber or tetrafluoroethylene resin) Explosion proof V/ VL S/ SV NP/NP/ NVP C/ MX/ Other.P. systems PD/FD/ PJ CVE/ CVSE CPE/ CPD Medical analysis Custom order Options are shown in ( ). eneral purpose valve 51
Pilot kick type 2 port solenoid valve : Normally closed,normally open GENERAL PURPOSE VALVE ADK11 ADK12 SERIES
K11 K1 Series Pilot kick type port solenoid valve : Normally closed,normally open NRL PURPS VLV K11 K1 SRIS iaphragm structure Port size : Rc1/, Rc3/, R1/, R3/, R1 JIS symbol K11(normally closed) UT K1(normally
More informationICO4S 2/2, 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled
ICO4S /, / or 5/ poppet valves > > Port size: /4... /4 (ISO G/NPT) or manifold version > > Reliable and long life, ideal for a one time installation > > Direct acting solenoid valve for the control of
More informationOperating pressure (bar) kv factor (m 3 /h) *3)
/ way poppet valves (stainless steel) electromagnetic actuated, directly controlled G /8, G /4 or /4 NPT Working from 0 bar up Assembled free of oil and grease Suited for fine vacuum down to,33 0 - mbar
More informationICO3S - 2/2, 3/2 or 5/2 poppet valves Electromagnetically actuated, direct solenoid operated
ICOS - /, / or / poppet valves > > Port size: /... / (ISO G / NPT) Namur or manifold > > Control of pneumatic or hydraulic operated equipment > > Direct acting solenoid valve > > High flow > > bar inlet
More informationFlow. Flow. N/en
/ poppet valves electromagnetic actuated, directly controlled G /4 or /4 NPT Working from 0 bar up Short switching times Suited for fine vacuum down to, 0 - mbar For a.c. solenoid systems with integrated
More information21023, 21025, 2/2 Direct solenoid actuated poppet valves
03, 05, / > > Port size: G/4, G/ > > Working from 0 bar up > > Suitable for mediumhigh vacuum down to.33 0 - mbar l/s > > Compact design > > Valves and solenoids are ATEX approved. Additional international
More informationDiscrete valve: Body porting 3, 5 port pilot operated valve 3KA1/4KA1/2/3/4 Series
Discrete vlve: ody porting, port pilot operted vlve K/4K/2//4 Series pplicle cylinder ore size: 20 to 60m CD DT VILLE. JIS symol Port vlve 2position NC type single P R Port vlve 2position NO type single
More information3/2 5/2 SERIES 362/562
Manual and Pilot Operated Spool Valves 6L Stainless Steel and Brass Bodies /4" to " NPT / / 6/6 Features Ideal for valve automation for the oil and gas market Reliable, robust design with high flow performance
More informationSeries 95000, 2/2 Direct solenoid actuated poppet valve
> Port size: /4 (ISO G or NPT), G/ > Working from 0 bar up > Short switching times > Suited for fine vacuum down to,33 x 0 - mbar > For a.c. solenoid systems with integrated rectifier (40... 60 Hz) > Variable
More informationDirect solenoid and solenoid pilot operated valves
Direct solenoid and solenoid pilot operated valves Series 59 Individual mounting Series inline 35 100 Ext. pilot port Accumulator EXH. Pilot valve Function plate From accumulator Pilot exhaust To accumulator
More informationDirect solenoid and solenoid pilot operated valves
Direct solenoid and solenoid pilot operated valves Series 55 Individual mounting Series inline 35 Sealed solenoid enclosure Manual operator 100 200 Ext. pilot port Ext. pilot Pilot filter Pilot exh. 55
More information95100, 2/2 (stainless steel) Direct solenoid actuated poppet valves
9500, / (stainless steel) > > Port size: G/8, G/4, /4 NPT > > Working from 0 bar up > > Assembled free of oil and grease > > Suited for fine vacuum down to,33 0 - mbar > > For a.c. solenoid systems with
More informationDirect solenoid and solenoid pilot operated valves
Direct solenoid and solenoid pilot operated valves Series 57 Individual mounting Series inline 35 To accumulator Sealed solenoid enclosure 100 200 Ext. pilot port Pilot valve Function plate From accumulator
More information98 Series Back Pressure. Valve Link. Features. Fisher Controls. August 1993 Bulletin 71.4:98
Series Back Pressure and Type Relief VL000 Valves FIELDVUE Valve Link Fisher Controls August Bulletin.: The Series (figure ) is used for back pressure or relief applications in liquid, gas, air, and steam
More informationOperating pressure (bar)
/ poppet valves electromagnetic actuated, directly controlled G /4, /4 NPT, G /, / NPT or flanged with NAMUR Interface Main application: single operated actuators for plants Valves for safety systems up
More informationElectromechanical pressure switches
Presentation Electromechanical pressure switches For control circuits, types ACW and ADW Presentation Pressure switches type ACW and ADW are switches for control circuits, with an adjustable differential.
More information21D Allfluid pressure switch, electromechanically actuated
D > > 0,... 0, bar (0,... psi), G/, / NPT > > High accuracy > > High number of switching cycles > > Microswitch approved by UL and CSA > > Fixed or adjustable hysteresis > > Shock and vibration tested
More information3/2 Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G1/2, 1/2 NPT or flanged with NAMUR interface
9805 / Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G/, / NPT or flanged with NMUR interface Main application: single operated process actuators TÜV-approval
More informationHow to Order. Manual override. : Non-locking push style. E: Push-turn locking lever style. Electrical entry
SY000/000/7000 Base Mounted Valve Single Unit 1 SY 2 40 Series SY000 SY000 7 SY7000 L How to Order A/B port size Symbol Post size Applicable series Without subplate Rc(PT) 1 8 01 SY000 With subplate Rc(PT)
More informationGB MIX COMUNICAZIONE - MI. Digital Electro-pneumatic Regulator ER Series
GB MIX COMUNICAZIONE MI Digital Electropneumatic Regulator Series N E W w w w. c a m o z z i. c o m Digital Electropneumatic Regulator Series Port G/ SPECIFICATIONS XXX SPECIFICATIONS XXX ITEM // X P X
More information6215L Inline & NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve
L Inline & NMUR series, / & / > Port size: / (ISO /NPT) or flanged with NMUR interface > Suited for outdoor use under critical environment conditions (see solenoid list) > Variable valve solenoid combination
More informationMaterial Seat seal. N/en
0 / poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR interface TÜV-approval based on IEC 6 8 Valves for safety systems up to SIL Standard NAMUR type - redundancy:
More informationDirect solenoid and solenoid pilot operated valves
Direct solenoid and solenoid pilot operated valves Series 1300 Individual mounting Series sub-base plug-in 35 100 Pilot air accumulator Internal pilot supply check valve Moisture and dust seal Manual operator
More informationStandardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.
Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG 9 1610 and 1700 Nl/min (1.636 and 1.728 Cv) Order code Series and function 1) Plug socket see page
More information80265 series, 3/2 Indirect solenoid actuated poppet valve
> > Port size: G/... G > > High flow rate > > Optionally air pilot operated > > High repeatability of switching time > > Variable valve solenoid combination Technical features Medium: Compressed air, filtered,
More informationAssembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug
Vibration Limit Switch Features Limit switch for liquids External function test with test magnet Onsite function check possible thanks to LED indication Large selection of process connections for hassle-free
More information3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface
9805 / Directional control valves Direct solenoid operated poppet valves Internal thread G /, / NPT or flanged with NAMUR interface Main application: single operated actuators for plants TÜV-approval based
More informationElectro-pneumatic control valves
Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E06620N
More informationsize size
BE/BE ISO 99/ Valves - Compliance with ISO 99/ international standards - Full range: - - - size - Two different internal commutation system: mixed and spool, appreciated for decades thanks to their maximum
More information/2 way indirect solenoid operated valves G 1/2, 1/2 NPT or flanged with NAMUR Interface
9805 / way indirect solenoid operated valves G /, / NPT or flanged with NMUR Interface Main application: single operated actuators for plants Valves for safety systems up to SIL (IE 6508) dd-on manual
More information24011 series, 3/2 Direct solenoid actuated poppet valve
0 series, / > Port size: / (ISO G or NPT), NAMUR Interface > Add-on manual override or inductive limit switches on request > Main application: Single and double acting actuators > TÜV-approval based on
More informationG 1/2 30,5 A Brass NBR 0,8 3,
4/2 way poppet valves electromagnetic actuated, directly controlled /4 & /2 Working from 0 bar up Suitable for vacuum range down.33 0-2 mbar l/s Protection class : IP 65, Ex em, Ex d TEX approved (see
More information26360, 80207, 3/2, 5/2 & 5/3 Indirect solenoid actuated spool valves
66, 87, /, 5/ & 5/ > > Port size: G/ & G/ > > Compact design > > Easily interchangeable solenoid > > tandard manual override > > ll valves available with Ex protected coils (TEX or other international
More informationISO*STAR (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves
*STR (SX, SXP) / & / > > Sub-base mounted, 99- s, or > > Specially coated glandless spool and sleeve for long trouble-free life > > Integral flow regulators available on and s for cylinder speed control
More informationSolenoid Valves PN16 for gas flow interception
s 7 684 INTELLIGAS Solenoid Valves PN16 for gas flow interception E... 2 way solenoid valves, threaded or flanged connections, brass or bronze body. 12V DC or 230V AC coil with manual reset. Normally Open
More informationV88 series Redundant valve manifold systems - Semi modular 2oo2 Availability
oo Availability > > Semi modular design - Maxseal valves > > Stainless steel visual indicators and exhaust guards as standard > > able terminations inside coil housing > > International approvals > > Stainless
More information97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve
9700 NAMUR series, / & / > > Port size: /4 (ISO G or NPT), NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve >
More informationISO STAR Solenoid & pilot actuated spool valves Sub-base 5/2 & 5/3, ISO #1... ISO #3
ISO STR Solenoid & pilot actuated spool valves Sub-base 5/2 & 5/3, ISO #... ISO #3 Specially coated glandless spool and sleeve for long life vailable with integral flow regulators on ISO # & #2 sizes ow
More information97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT
70 Inline 3/, / & /3 way spool valves electromagnetic actuated, indirectly controlled G/, / NPT, G/, / NPT Main application: single and double operated actuators TÜV-approval based on type examination
More informationDigital electropneumatic Positioner for the integrated mounting on process control valves
Digital electropneumatic Positioner for the integrated mounting on process control valves Type 8692 can be combined with Compact stainless steel design Graphic display with backlight Easy start-up Comprehensive
More informationMPreC - Pressure Relief Device Order specification sheet
- Pressure Relief Device Order specification sheet -Series LARGE MESSKO PRESSURE RELIEF DEVICE Complete the Order-N o by choosing the specific add-on s: e.g.: LMPRD 685-08-22-N01-00 Order-N o : Parameter
More information98025 NAMUR 3/2 poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface
9805 NMUR / poppet valves electromagnetic actuated, indirectly controlled G /, / NPT or flanged with NMUR Interface Main application: single operated actuators for plants Valves for safety systems up to
More informationElectric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 NPT
1/4 to 2 NPT Features Direct mount ISO5211 Full Port 316 stainless steel ball valve 1000 PSI working pressure at 100 F (38 C) Highly visual dome style valve position indicator Rugged aluminum Type 4X weatherproof
More informationV88 series Redundant valve manifold systems - Semi modular 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability
oo Safety, oo Availability and oo Safety and Availability > > Semi modular design - Maxseal valves > > Stainless steel visual indicators and exhaust guards as standard > > able terminations inside coil
More informationDigital electropneumatic Positioner for the integrated mounting on process control valves
Digital electropneumatic Positioner for the integrated mounting on process s Type 8694 can be combined with Digital smart positioner Automatic teach function Contact-free position sensor Compact stainless
More information8 Submersible Motors Standard
Applications These motors are built for dependable operation in vertical 8 diameter or larger water wells. Basic Features Double Flanged NEMA mounting design Stainless steel splined shaft StatorShield
More informationElectropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s
ElectroPneumatic Miniature Control Valves Order/Technical Support Tel: (800) 6773 / FAX: (800) 677386 / www.crouzetusa.com /47 Electropneumatic miniature control valves Mounting Connectors Minisolenoid
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G
More informationTotal Supplier of Pressure Switches
Total Supplier of Pressure Switches QEC25000 ISO 9001: 2015 Design and manufacturing of pressure switch Taking advantage of the aundant experiences, Taihei Boeki Co., Ltd. that specializes in manufacturing
More informationInductive Proximity Sensor
Inductive Proximity Sensor Miniature, Slim-styled Proximity Sensor Space-saving Sensor ideal for timing cam and dog detection. Four mounting holes provided: two each mounting from side or rear of the housing.
More informationV03, V04 and V05 Series
V03, V04 and V05 Series / and 3/ Poppet Valves Electrically Actuated G 1 8, G 1 4, CNOMO and Interface Extensive range of power and orifice size options Removable coil Manifold rail for 1 to 0 valves Operating
More informationPipe fittings and flanges, sockets for bayonet locks
Data Sheet 909750 (909725) Page 1/7 Pipe fittings and flanges, sockets for bayonet locks for temperatures up to 600 C for different fitting lengths simple installation and replacement pressure-tight sealing
More informationDigital electropneumatic Positioner for the integrated mounting on process control valves
Digital electropneumatic Positioner for the integd mounting on process control valves Type 8692 can be combined with Compact stainless steel design Graphic display with backlight Easy start-up by automatic
More informationSafety switches with separate actuator
4 Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD VF KEYD6 VF KEYD VF KEYD10 ACTUATORS CONTACT BLOCKS 6 snap action overlapped FR FX FK FW 0 1 4 NC NO+1NC
More informationRT2E Compact temperature switch Explosion proof
ompact temperature switch Explosion proof Main Features Excellent repeatability Dead band adjustment for regulation Fix dead band for control and alarm Light weight Explosion proof Hazardous areas 1, 2,
More informationWafer Type Butterfly Valve
Rev.B Wafer Type Butterfly Valve Type Summary Butterfly valve actuator type Actuator Type Description Rated Output Force Supply* Control/ Feedback Signal Running Time Weight kg TBV-50-X.V Proportional
More informationSpecifications 36 Series Valve (Lifting Solenoid)
Specifications 36 Series Valve (Lifting Solenoid) Operating Data Fluids: ir or Inert Gas Lubrication: Not Required. But if used, select a medium aniline point oil (between 180ºF to 210ºF). Safe Operating
More informationLimit Switch Connectors
CSM_LimitSwitch_Connector_DS_E Connectors (SC Series) Cabtire cables and flexible tubes with various diameters are used to connect machine tools and controllers with Limit Switches. To ensure the watertightness
More informationMaterial pressure (bar) (Cv (US) kv x 1,2 Seat
00 / poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 08, DIN V Valves for safety systems up to SIL Solenoid valve also
More informationM3P..G/A, M3P..F/A Modulating control valves (PN16) for chilled and hot water systems
MP..G/A, MP..F/A Modulating control valves (PN) for chilled and hot water systems Three-way or straight-through valves with magnetic actuators for modulating control of chilled and hot water systems. Short
More informationDigital electropneumatic Positioner for the integrated mounting on process control valves
Digital electropneumatic Positioner for the integrated mounting on process s Type 8694 can be combined with Automatic teach function Contact-free position sensor Compact stainless steel design AS-Interface
More informationSeries EVS7-6/7-8/7-10
onforming to ISO Standard Solenoid Valve (with M onnector) Series EVS7-6/7-8/7-0 (Size ) (Size ) (Size ) VK VZ VF VFR V VZS VFS VS VQ7 Large capacity Flow rate EVS7-6 (Size ) 00 l/min (NR) EVS7-8 (Size
More informationPneumatic Control Unit for the integrated mounting on process valves
Pneumatic Control Unit for the integrated mounting on process valves Type 890 can be combined with Compact design Pilot valve with high air flow rate Internal control air channel Optical position indicator
More informationSafety switches with manual mechanical delay and separate actuator
D Safety switches with manual mechanical delay and separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF VF KEYF VF KEYF7 VF KEYF ACTUATORS MECHANICAL DELAY C L L0 Short knob 0 sec. Short knob sec.
More informationSafety switches with separate actuator
A Safety switches with separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF VF KEYF ACTUATORS CONTACT BLOCKS 9 snap action overlapped FD FP FL FC 21 22 33 3 3NC 2NO+1NC 1NO+ CONDUIT
More informationControl Head for the integrated mounting on process valves
Control Head for the integrated mounting on process valves Type 8691 can be combined with Compact stainless steel design Integrated analogue valve position registration (Teach function) Coloured illuminated
More informationFlowtronic D 607 Series
Flowtronic D 607 Series Proportional Technology www.asco.com FLOW CONTROL: 607 SERIES FLOWTRONIC D Flowtronic D Flowtronic D is a digitally operated flow controller up to 70 SCFM (2000 Nl/min). The Flowtronic
More informationSafety switches for hinged doors
C Safety switches for hinged doors Selection diagram FR FM FX FZ FK 18 7 9 snap action overlapped CONTACT BLOCKS 21 NC 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled
More informationMechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems
Well Probe Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems The switch can be used to detect the water level within a well. When the water level in the
More informationPosition switches FD series
Position switches FD series Selection diagram 01 08 10 11 18 19 0 04 05 Ø 8 mm Ø 1,7 mm external rubber stainless steel stainless steel glass fibre rod gasket sphere sphere 31 51 5 57 35 56 41 4 adjustable
More informationSYSTEM CONNECTORS FOR W-CDMA
SYSTEM CONNECTORS COMPLINT WITH EIJ RC-5238 (CONNECTOR FOR IMT-2000 MOBILE PHONES) SYSTEM CONNECTORS FOR W-CDM Receptacle Signal 10 contacts with coaxial, with charging terminals ( type) Plug Signal 10
More information2/2 VALVES FOR WATER. Water 2 WAY VALVES. Actuation Body Function Specification Port
The Parker 2 way valves (1 way for inlet and 1 way for outlet) for water and neutral liquids are optimized constructions for liquids handling. The exclusive diaphragm design gives a superior flow rate
More informationINDUSTRIAL PNEUMATICS - valves
Ball valves Mini ball valve 6560 type Body material: Ball material: Ball seal: Spindle seal: Working temp.: Nickel-plated brass Chromium-plated brass PTFE NBR From -20 C up to +80 C General purpose valve
More informationTest 12 Connection Thread S12,65 x 1,5. Test Coupling with Piston Valve. Fast Coupling for. Advantages. Working Pressure. Media.
Test 12 Connection Tread S12,65 x 1,5 Introduction SKK12 Test Coupling wit Piston Valve Test Coupling SKK12 Internal Piston Vibration Safety O-ring Spring Sealing at Port Connection Port Connection Fast
More informationData is only for informational purpose. All specifications are subject to change without notice.
MV Data is only for informational purpose. All specifications are subject to change without notice. 1 First in knife gate 2018-12-19 solutions issue 24 Knife gate valve MV Stafsjö s knife gate valve MV
More informationHERION SERIES Indirect solenoid actuated spool valves
HERION SERIES Indirect solenoid actuated spool valves for single and double acting actuators with NAMUR interface /2, /2, /, NC/APB, G/, G/2 Valves for safety systems up to SIL (IEC 08) Crossover-free
More informationPin plunger D2JW-011 D2JW-011-MD. Short hinge lever D2JW-01K1A1 D2JW-01K1A1-MD. Hinge lever D2JW-01K11 D2JW-01K11-MD
Sealed Snap ction Switch DJW Immersion-Proof Subminiature Snap ction Switch Ultra-small and highly sealed Water-tight housing conforming to IEC IP67 Wide range of operating temperature from -40 to 85 C
More informationRT2Y Compact temperature switch intrinsic safety
ompact temperature switch intrinsic safety Main Features Excellent repeatability Fix dead band for control and alarm Resistant to accidental overtemperature Intrinsic safety Hazardous area 0, 1, 2 pplications
More informationLimit Switch Connectors
CSM_LimitSwitch DS_E s (SC Series) Cabtire cables and flexible tubes with various diameters are used to connect machine tools and controllers with Limit Switches. To ensure the watertightness of the edges
More informationERNG-X. Description. Applications. ERNG-X Specifications DERNG2108X012
ERNG-X DERNG2108X012 Description The ERNG-X is a steady state no bleed engineered system for accurate and reliable control of Natural Gas. The ERNG-X includes a pressure regulator, preconditioning filters,
More informationInsertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )
The flow meter is based on the thermal mass flow measurement and is ideal for measuring the flow of compressed air and gases in pipes from DN50 (2 ) to DN700 (28 ). With the, the consumption of compressed
More informationpanasonic.net/id/pidsx/global
73 PHOTO PHOTO Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1563~ guide... P.699~ General precautions... P.1566 MEASURE Simple &
More informationKOBOLD PDA Series Digital Pressure Transmitter
KOBOLD PDA Series Digital Pressure Transmitter PDA-153 Series User Instructions KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh, PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 www.koboldusa.com
More informationOperation mode. Output configuration. Relay DC SSR. Light-ON Dark-ON (switch selectable) Relay DC SSR. Relay DC SSR
Built-in Power Supply Photoelectric Sensor CSM DS_E_12_3 Model Contribute to Overall Cost Reduction erminal Block Models Easy to wire and adjust. For the most recent information on models that have been
More information3-PORT SEAT VALVES PN16 WITH EXTERNALLY THREADED CONNECTIONS STAZ-16, STBZ-16, STCZ-53 DATASHEET
-PORT SEAT VALVES PN WITH EXTERNALLY THREADED CONNECTIONS STAZ-, STBZ-, STCZ- DATASHEET In small or medium-sized heating, ventilating and air conditioning plants as a control or safety shutoff valve. For
More informationSUCTION FILTERS. PRESSURE (ISO :2002) Collapse, differential for the fi lter element (ISO 2941): 1 MPa (10 bar)
COMPONENTS SUCTION ILTERS SD MATERIALS Cover & housing: Anodized aluminium alloy or 6&6 only: Cover: anodized aluminium alloy Housing: steel ypass valve: Polyammide Seals: NR Nitrile (KM on request fl
More informationCompact Bellows Pumps
Compact Bellows Pumps Compact Bellows Metering Pumps were specifically designed for metering applications requiring low discharge pressures. Compact pumps have been successfully applied in photo, X-ray
More informationSeries 3730 Type Electropneumatic Positioner
Series 3730 Type 3730-0 Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves Set point Travel 4 to 20 ma 5.3 to 200 mm The positioner
More informationMODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)
Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source
More information97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT
705 Inline 3/, 5/ & 5/3 spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Valves for safety systems up to SIL (IEC 6508) Crossover-free
More informationISO*STAR - ATEX version (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves
*STR - TX version (SX, SXP) / & / > > Sub-base mounted, 99- s, or > > Specially coated glandless spool and sleeve for long trouble-free life > > Integral flow regulators available on and s for cylinder
More informationHead-separated Dual Display Digital Pressure Sensor DPC-L100 SERIES DPH-L100 SERIES. High-precision detection of fluid and air pressure
689 PHOTO PHOTO Dual Display Digital Pressure Sensor DPC-L100 SERIES SERIES General terms and conditions... F-17 Sensor selection guide... P.661~ Related Information Glossary of terms... P.1373~ General
More information26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.
66, 87 Inline / and 5/ directional control valves NG 6 and Operation: elektromagnetic Indirectly controlled soft seal spool valves Port size: G /4 and G / For single and double operated actuators Manual
More informationType i2p-100 Electro-Pneumatic Transducer
Product Bulletin i2p-100 Transducer Type i2p-100 Electro-Pneumatic Transducer The Type i2p-100 electro-pneumatic transducer, shown in figure 1, uses a patented converter module that converts a milliampere
More informationClamping Device, Series 2709
Electric Drives and Controls Hydralics Linear Motion and Assembly Technologies Pneumatics Service Clamping Device, Series 2709 Technical data Pneumatic Open mechanism Technical Data Type Power transmission
More informationThread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm
Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information
More informationSmall Circular Connector. JN1/JN2 Series. Cap
COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Small Circular Connector JN1/JN2 Series CONNECTOR MB-0054-10 June 2012 Angle Plug [JN1] [JN2] [JN1] [JN2] Straight Plug Cable Connecting Individual Plug
More informationLS 5000 series Vibration Level Switch for liquids
Vibration Level Switch for liquids Set-up without adjustment Integrated fault monitoring Unaffected by product variations in density, conductivity, dielectric constant or viscosity Insensitive to foam,
More informationPressure Switch CE40. Digital settings available via IR data communication without actually applying pressure to the unit
Pressure Switch CE0 NEW IR Communication type Pressure Switch Rev. Fluids/Gasses Utilizing Stainless Diaphragm Utilizes stainless steel diaphragm for use with a wide variety of pressure media Excellent
More information