1 PRIMERGY BX630 S2 Scalable Server-Blade Service Supplement Edition December 2007

2 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by to Certified documentation according to DIN EN ISO 9001:2000 To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001:2000. cognitas. Gesellschaft für Technik-Dokumentation mbh Copyright and Trademarks Copyright 2007 Fujitsu Siemens Computers GmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers.

3 Contents 1 Preface Documentation Overview Notational Conventions Procedure Important Notes Notes on Safety Environmental protection Replacement Routines Preparation Replacing the control panel board Replacing processors Diagnosis and Maintenance Server Blade Diagnostic LEDs Recovering the Server Blade BIOS Spare Parts and Add-On Modules Abbreviations Index BX630 S2 Service Supplement

4

5 1 Preface The PRIMERGY BX630 2 Scalable Server Blade is an AMD-based server blade that can be operated in the PRIMERGY BX600 S2 basic unit. It can also be operated in slots 1-3 and 5-9 of the BX600 S2 basic unit. The PRIMERGY BX630 2 Scalable Server Blade can be installed as a dual-socket server blade or in a multi-blade configuration as a quad-socket server blade. 1.1 Documentation Overview Concept and target groups This Service Supplement supplements the information contained in the Operating Manual. V ATTENTION! The activities described in this manual may only be performed by specialist personnel with technical training. I The installation and removal of the hot-plug components is described in the Operating Manual supplied with the server. Service DVD A service DVD is available for service partners of Fujitsu Siemens Computers. This DVD contains the following manuals in PDF format: the Safety manual the Ergonomics manual the Operating Manual for PRIMERGY BX630 2 the Options Guide for PRIMERGY BX630 2 the documentation for the server blade models available for the PRIMERGY BX600 S2/S3 basic unit I These PDF files can also be downloaded from the Internet free of charge: At you will find an overview page showing the online documentation available on the Internet. You can go to the PRIMERGY Server documentation by clicking on industry standard servers. BX630 S2 Service Supplement 5

6 Documentation Overview Preface Information/Activity Manual Features and technical data of the server blade Operating Manual Installation and initial operation, such as: Connections to the basic unit Operation Configuring the server blade Firmware update (server blade BIOS and BMC) Installing the server blade in the basic unit BIOS setup Troubleshooting Installing/removing hot-plug components: Hard disk modules Extensions and conversions Installing memory modules Adding processors Installing an optional I/O module Replacing the battery Upgrading to a quad-socket server blade Replacement routines Replacing the control panel Exchanging the processor Diagnostics Diagnostic LEDs BIOS recovery Spare parts list Detailed safety information Table 1: Overview of the BX630 2 server blade documentation Options Guide Service Supplement Safety manual 6 Service Supplement BX630 S2

7 Preface Notational Conventions 1.2 Notational Conventions The following notational conventions are used in this manual: quotation marks V CAUTION! I indicate names of chapters and terms that need to be emphasized. indicates an activity that must be performed. indicates that, if you ignore the information given at this point, your health, the correct functioning of your system or the security of your data may be at risk. indicates supplementary information, remarks and tips. Table 2: Notational conventions BX630 S2 Service Supplement 7

8

9 2 Procedure V ATTENTION! The activities described in this manual should only be performed by engineers, service personnel or technical specialists. First of all please familiarize yourself with the safety instructions in the chapter Important Notes on page 11ff. Make sure that all the manuals you need (see service DVD) are available, printing out the PDF files if necessary. You will definitely need the operating manuals of the server blade and of your BX600 S2 or BX600 S3 basic unit. Shut down the server blade correctly, switch it off and remove it from the basic unit as described in the chapter Replacement Routines on page 17f. Replace the defective component as described in the relevant chapter. Close the server blade. Start the server blade. 1 If necessary, configure the operating system as required. 1 1 See Operating Manual. BX630 S2 Service Supplement 9

10

11 3 Important Notes This chapter provides safety instructions which you must observe when handling your system. 3.1 Notes on Safety I The following safety instructions can also be found in the manual entitled Safety. This device complies with the relevant safety regulations for IT equipment, including electronic office machines for use in an office environment. If you have any questions, contact your sales outlet or the Fujitsu Siemens Computers customer service center. V ATTENTION! The activities described in this manual should only be performed by engineers, service personnel or technical specialists. Equipment repairs should only be performed by qualified staff! Any failure to observe the guidelines in this manual could endanger the user (through electric shock, fire hazards) or damage the equipment. Please note that any unauthorized opening of the device will result in the invalidation of the warranty and exclusion from all liability. Before setting up V ATTENTION! During installation and before operating the device, observe the instructions on environmental conditions for your device (see Operating Manual). If the device is brought in from a cold environment, condensation may form both inside and on the outside of the machine. Before operating the device, wait until it is absolutely dry and has reached approximately the same temperature as the installation site. Any failure to observe the guidelines in this manual could damage the equipment. BX630 S2 Service Supplement 11

12 Notes on Safety Important Notes V ATTENTION! Transport the device only in its original packaging or in packaging which protects it from knocks and jolts. Installation and operation V ATTENTION! Read the notes on installation and operation in the Operating Manual of the PRIMERGY BX600 S2 or BX600 S3 basic unit. When installing the server blade in the basic unit, beware of the energy hazard at the midplane conctacts. A short-circuit on these contacts may damage the system. Data cables must be adequately shielded to avoid interference. For the LAN wiring, the requirements according to standards EN and EN /2 apply. The minimum requirement is the use of a protected LAN line of category 5 for 10/100 Mbps Ethernet, and/or of category 5e for Gigabit Ethernet. The requirements of the specification ISO/IEC must also be taken into account. Route the cables in such a way that they do not form a potential hazard (tripping) and cannot be damaged. When connecting the device, refer to the relevant notes in the Operating Manual. Do not connect or disconnect any data transmission cables during a thunderstorm (lightning hazard). Be careful to ensure that no objects (e.g. jewelry, paper clips etc.) or liquids get inside the device (electric shock, short circuit). In emergencies (e.g. damaged casing, elements, or cables, penetration of liquids or foreign bodies), switch off the device immediately, unplug it from the grounded power outlet, and contact your customer service centre. Proper operation of the device (in accordance with IEC60950/EN 60950) is only ensured if the casing is completely assembled and the rear covers for the installation openings are in place (electric shock, cooling, fire protection, interference suppression). 12 Service Supplement BX630 S2

13 Important Notes Notes on Safety V ATTENTION! Install only system extensions that satisfy the requirements and rules governing safety, electromagnetic compatibility, and telecommunications terminal equipment. If you install other extensions, you may damage the system or violate these safety regulations. Information on which system extensions are suitable can be obtained from the customer service center or your sales outlet. The components marked with a warning label (e.g. lightning symbol) may only be opened, removed, or exchanged by authorized, qualified personnel, with the exception of the hot-plug/hot-swap components. If you cause a defect on the device by installing or exchanging system extensions, the warranty will be invalidated. You may only set the resolutions and refresh rates specified in the operating manual for your monitor. Otherwise, you may damage the monitor. If you are in any doubt, contact your sales outlet or customer service center. Batteries V ATTENTION! Incorrect replacement of batteries can lead to risk of explosion. The batteries must be replaced with an identical battery or with a battery type recommended by the manufacturer. Do not throw batteries into the trash can. Please dispose of them in accordance with local regulations for special refuse. When replacing the lithium battery in the relevant components, always follow the instructions in this manual. All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). The marking also contains the chemical symbol of the heavy metal that classifies the battery as a pollutant: Cd Cadmium Hg Mercury Pb Lead BX630 S2 Service Supplement 13

14 Electrostatic-Sensitive Devices Important Notes Modules with electrostatic-sensitive devices Modules with electrostatic-sensitive devices are identified by the following sticker: Figure 1: ESD label When handling modules with ESDs, it is essential that you observe the following guidelines: You must always discharge static build-up, e.g. by touching a grounded object, before working with such components. Any devices or tools that are used must be free of electrostatic charge. Always hold components with ESDs at the edges. Do not touch any connectors or conduction paths on an ESD. Wear a suitable grounding cable that connects you to the external chassis of the basic unit. Place all the components on a pad which is free of electrostatic charge. I For a detailed description of how to handle ESD components, see the relevant European and international standards (EN , ANSI/ESD S20.20). 14 Service Supplement BX630 S2

15 Important Notes Electrostatic-Sensitive Devices 3.2 Environmental protection Environmentally-friendly product design and development This product has been designed in accordance with the Fujitsu Siemens Computers standard for environmentally friendly product design and development. This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account. This saves resources and thus reduces the harm done to the environment. Energy-saving information Devices that do not need to be constantly switched on should be switched off until they are needed as well as during long breaks and after completion of work. Packaging information Do not throw away the packaging. You may need it later for transporting the system. If possible, the equipment should only be transported in its original packaging. Information on handling consumables Please dispose of printer consumables and batteries in accordance with the applicable national regulations. In accordance with EU directives, batteries must not be disposed of with unsorted domestic waste. They can be returned free of charge to the manufacturer, dealer or an authorized agent for recycling or disposal. All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). They are also marked with the chemical symbol for the heavy metal that causes them to be categorized as containing pollutants: Cd Cadmium Hg Mercury Pb Lead Labels on plastic casing parts Please avoid sticking your own labels on plastic parts wherever possible, since this makes it difficult to recycle them. BX630 S2 Service Supplement 15

16 Electrostatic-Sensitive Devices Important Notes Returns, recycling and disposal The device must not be disposed of with domestic waste. This device is labeled in compliance with European directive 2002/96/EC on waste electrical and electronic equipment (WEEE). This directive sets the framework for returning and recycling used equipment and is valid across the EU. When returning your used device, please use the return and collection systems available to you. Further information can be found at Details regarding the return and recycling of devices and consumables within Europe can also be found in the Returning used devices manual, via your local Fujitsu Siemens Computers branch or from our recycling center in Paderborn: Fujitsu Siemens Computers Recycling Center D Paderborn Tel Fax Service Supplement BX630 S2

17 4 Replacement Routines V ATTENTION! When working with systems and boards, make sure you observe the safety information in the chapter Important Notes on page 11ff. 4.1 Preparation If you want to replace components which are not hot-pluggable, you must remove the server blade from the basic unit and open it. Exit all applications and shut down the server blade correctly. Press the On/Off button on the server blade control panel. BX630 S2 Service Supplement 17

18 Preparation Replacement Routines Removing the server blade from the basic unit 2 1 Press the two touch points (1) to unlock the handles. Open out the two handles (2) simultaneously to disengage the server blade. 1 2 Figure 2: Disengaging the server blade 18 Service Supplement BX630 S2

19 Replacement Routines Preparation Pull the server blade out of the basic unit. Figure 3: Removing the server blade from the basic unit BX630 S2 Service Supplement 19

20 Preparation Replacement Routines Removing the housing cover Figure 4: Removing the housing cover Undo the two knurled screws (1). Push the housing cover as far as possible in the direction of the arrow (2). Take off the housing cover. The server blade components are now freely accessible. 20 Service Supplement BX630 S2

21 Replacement Routines Replacing the control panel board 4.2 Replacing the control panel board The electronic elements of the control and connection panel of the server blade are located on a board that is connected to the system board of the server blade via a foil cable. Figure 5: Control panel board with connection cable Requirements The server blade has been removed from the basic unit The cover of the server blade has been removed V ATTENTION! Make sure you observe the safety notes in the chapter Important Notes on page 11ff. BX630 S2 Service Supplement 21

22 Replacing the control panel board Replacement Routines Removing the control panel board 2 1 Figure 6: Pulling off the foil cable Undo the fastening screws (1) on the control panel board. Loosen the clamping bracket (2) and disconnect the cable of the control panel board from the system board. Figure 7: Unfastening the control panel board Remove the control panel board with the connection cable from the server blade housing. Installing the control panel board To install the control panel board follow the above procedure in reverse. 22 Service Supplement BX630 S2

23 Replacement Routines Replacing processors 4.3 Replacing processors You can install one or two AMD Opteron MP processors in the basic module of the server blade, see Spare Parts and Add-On Modules on page 38. V ATTENTION! Always use processors of the same type. All processors must have the same frequency and cache size. For multi-processor mode use a suitable multi-processor operating system. Never touch the processor core. The thermal paste must be intact for mounting the processor. Never install a processor without a heat sink! The processor is likely to overheat, which may cause damage to the processor and the system board. Requirements The server blade has been removed The cover of the server blade has been removed BX630 S2 Service Supplement 23

24 Replacing processors Replacement Routines Removing the heat sink Figure 8: Removing the dummy heat sink Undo the three screws which fasten the heat sink and remove it. Installing a processor I The BX630 2 server blades may have two different processor sockets, see figure 9: Foxconn processor socket Figure 9: Processor socket variants Tyco processor socket 24 Service Supplement BX630 S2

25 Replacement Routines Replacing processors The following section describes how to install a processor in the Foxconn processor socket. Differences in handling a Tyco processor socket are indicated in the relevant steps. 2 1 Figure 10: Processor socket variant 1: Opening the socket Remove the protective cover by lifting it at the edge (1). Release the locking lever (2) by first pressing it down and then swiveling it up as far as it will go. BX630 S2 Service Supplement 25

26 Replacing processors Replacement Routines Figure 11: Processor socket variant 1: Opening the locking frame Swivel the locking lever of the processor socket upward. V CAUTION! Ensure that all processor socket pins are straight. If there are damaged pins the entire server blade must be replaced. Remove the processor from its protective wrapper. 26 Service Supplement BX630 S2

27 Replacement Routines Replacing processors A Figure 12: Inserting the processor (Foxconn socket) Position the new processor above the socket, and press it carefully into the socket. V CAUTION! The processor can only be installed in one direction. Make sure that the recesses on the processor (A) are aligned with the corresponding positioning elements (lugs) on the socket. I The Tyco processor socket only has positioning elements on one side, see (A) in figure 13. Figure 13: Processor socket variant 2: Inserting the processor A BX630 S2 Service Supplement 27

28 Replacing processors Replacement Routines 1 Figure 14: Locking the processor (Foxconn socket) Fold the locking frame of the processor socket down. Swivel the locking lever of the socket down. Lock the locking lever by pressing it under the bracket (1) on the processor socket. 28 Service Supplement BX630 S2

29 Replacement Routines Replacing processors V CAUTION! When locking the Tyco processor socket, make sure that the small clips on the locking frame (A) slide under the corresponding brackets on the outer socket frame, see figure 15. A Figure 15: Locking the processor (Tyco processor socket) BX630 S2 Service Supplement 29

30 Replacing processors Replacement Routines Installing the heat sink Please observe the following warning notices when installing a used heat sink. V CAUTION! Before mounting the heat sink, check that the heat sink compound is intact. If it is not, you must do the following before reinstalling the heat sink: Remove any remnants of the heat sink compound from the bottom of the heat sink and clean the top of the processor. Use a lint-free Isopropyl alcohol wipe (e.g. CleanTex TexPad 801, available from specialist dealers). Apply a new film of heat sink compound to the bottom of the heat sink. To install a new heat sink, proceed as described below. Figure 16: Preparing the heat sink Remove the yellow tape from the underside of the heat sink, and then remove the transparent cover protecting the thermal paste. 30 Service Supplement BX630 S2

31 Replacement Routines Replacing processors Figure 17: Fastening the heat sink Place the heat sink on the processor and fix it with the three supplied screws. Fasten the screws in the order shown in the figure. BX630 S2 Service Supplement 31

32

33 5 Diagnosis and Maintenance 5.1 Server Blade Diagnostic LEDs Diagnostic LEDs help to locate defective components in the server blade DIMM 1 DIMM 2 DIMM 3 DIMM 4 Battery CPU 1 DIMM 5 DIMM 6 DIMM 7 DIMM 8 D 1 2 Optional I/O Daughter Board CPU 2 Figure 18: Diagnostic LEDs Press the diagnostics button (D) to locate a defective component via its glowing diagnostics LED. The meaning of the LEDs is explained in table 3. BX630 S2 Service Supplement 33

34 Server Blade Diagnostic LEDs Diagnosis and Maintenance LED/ Meaning Button D Diagnostic button 1 CPU 2 error 2 I/O daughter card error 3 CPU 1 error 4 SDRAM module 1-4 error 5 SDRAM module 5-8 error 6 CMOS battery error Table 3: Meaning of the diagnostic LEDs 34 Service Supplement BX630 S2

35 Diagnosis and Maintenance Recovering the Server Blade BIOS 5.2 Recovering the Server Blade BIOS This section describes how to recover the BIOS of a server blade in the event of an error. V ATTENTION! This procedure must only be used in the event of an error. Requirements The basic unit is connected to the mains. The server blade has been switched off. An external floppy disk drive is present. Creating a BIOS flash floppy disk Extract the BIOS update ZIP archive file on a PC hard disk. I The data for creating the BIOS flash floppy disk is contained in the software pool Insert an empty DOS boot disk into the floppy disk drive. Copy the files containg in the ZIP archive to the DOS boot disk to create a BIOS flash diskette. Recovering the server blade BIOS Connect the monitor, keyboard and mouse to the KVM connector on the rear of the blade server chassis, see Operating Manual. Remove the server blade from the blade server chassis (see page 17) and open it. BX630 S2 Service Supplement 35

36 Recovering the Server Blade BIOS Diagnosis and Maintenance A SW5 CPU 1 CPU 2 Figure 19: Position of the user DIP switches (A) on the system board Set switch 4 of the DIP switches (A) on the system board to ON. Close the cover of the server blade and reinstall it in the blade server chassis, see page 17. Insert the BIOS flash floppy disk in a USB floppy disk drive and connect the floppy disk drive to the USB port of the server blade using the USB breakout cable, see Operating Manual. Press the KVM button on the control panel of the server blade (see Operating Manual) to switch the keyboard, mouse and the monitor of the KVM blade to the server blade. Switch on the server blade, see Operating Manual. 36 Service Supplement BX630 S2

37 Diagnosis and Maintenance Recovering the Server Blade BIOS After a short beep, the BIOS is uploaded. The status of the flash process is displayed on the KVM console. After the flash is completed, instructions are displayed for the following procedure: Switch off the server blade. Remove the server blade and open it. Set switch 4 of the user DIP switches on the system board to OFF. Close the server blade and reinstall it. Now you can put the server blade back into operation. BX630 S2 Service Supplement 37

38 Spare Parts and Add-On Modules Diagnosis and Maintenance 5.3 Spare Parts and Add-On Modules The following spare parts and add-on modules are available for the PRIMERGY BX630 2 server blade: Description Mat. No. 1 Part No. Server Blades BX630 S2 server blade (master module) S26361-K1131-V900 BX630 S2 server blade (slave module) S26361-K1131-V901 Prozessors CPU Opteron QC DP 1.7 GHz O HE V26808-B8198-V10 CPU Opteron QC DP 1.9 GHz O V26808-B8204-V10 CPU Opteron QC DP 1.9 GHz O HE V26808-B8203-V10 CPU Opteron QC DP 1.9 GHz O HE V26808-B8198-V12 CPU Opteron QC DP 2.1 GHz O V26808-B8199-V10 CPU Opteron QC DP 2.5 GHz O SE V26808-B8197-V11 CPU Opteron QC MP 1.9 GHz O V26808-B8206-V10 CPU Opteron QC MP 1.9 GHz O HE V26808-B8205-V10 CPU Opteron QC MP 1.9 GHz O HE V26808-B8194-V10 CPU Opteron QC MP 2.2 GHz O V26808-B8195-V10 CPU Opteron QC MP 2.5 GHz O SE V26808-B8193-V11 CPU Opteron DC DP 1.8 GHz O V26808-B8040-V10 CPU Opteron DC DP 2.0 GHz O V26808-B8040-V11 CPU Opteron DC DP 2.2 GHz O V26808-B8040-V12 CPU Opteron DC DP 2.4 GHz O V26808-B8040-V13 CPU Opteron DC DP 2.6 GHz O V26808-B8040-V14 CPU Opteron DC DP 2.8 GHz O V26808-B8040-V15 CPU Opteron DC DP 3.0 GHz O V26808-B8040-V16 CPU Heatsink HEATSINK PASSIV V26898-B880-V1 Table 4: Spare parts and add-on modules 38 Service Supplement BX630 S2

39 Diagnosis and Maintenance Spare Parts and Add-On Modules Description Mat. No. 1 Part No. Memory modules MEM 1GB 2X512MB DDR2-667 PC RG ECC S26361-F3449-L511 MEM 2GB 2X1GB DDR2-667 PC RG ECC S26361-F3449-L512 MEM 4GB 2X2GB DDR2-667 PC RG D ECC S26361-F3449-L513 MEM 8GB 2X4GB DDR2-667 PC RG D ECC S26361-F3449-L514 HDD modules HDD SAS 36GB 10K HOT PLUG 2.5" S26361-F3208-L136 HDD SAS 36GB 15K 3GB/S HOT PLUG 2.5" S26361-F3208-L536 HDD SAS 73GB 10K HOT PLUG 2.5" S26361-F3208-L173 HDD SAS 73GB 15K 3GB/S HOT PLUG 2.5" S26361-F3208-L573 HDD SAS 146GB 10K 3GB/S HOT PLUG 2.5" S26361-F3208-L114 DUMMY 2,5" KPL SNP:A3C I/O modules (daughter cards) FC MODULE 2X4GBIT/S BX600-FC42E S26361-F3306-L601 GBE LAN I/O MODULE (PCIE) S26361-F3451-L1 BX630 S2 boards BX630 SERVER BLADE (Server-Blade including ID label, without CPUs and memory modules) S26361-D2537-A11-2- R791 FRONTPANEL KIT W / CABLE SNP:A3C Table 4: Spare parts and add-on modules 1 Material number from ErsinXP database I Current information about BX630 2 spare parts and add-on modules is also provided by the FSC extranet service site ( From there you can also download the interactive PRIMERGY BX6xx Illustrated Spares Catalogue. Click Illustrated Spares Catalogue under the rubric PRIMERGY to open the spares portal. BX630 S2 Service Supplement 39

40

41 Abbreviations ASR&R Automatic Server Reconfiguration and Restart BIOS CD COM CPU Basic Input-Output System Compact Disk Communication Central Processing Unit DBMS Database Management System DDR Double Data Rate (RAM) DIMM Dual Inline Memory Module DVD ECC EDC EMC ESD Digital Versatile Disk Error Correcting Code Error Detection Code Electromagnetic Compatibility Electrostatic Discharge BX630 S2 Service Supplement 41

42 Abbreviations FC GAM HDD HU I/O ID IDE IP LAN LCD LED MGA MRL NIC Fibre Channel Global Array Manager Hard Disk Drive Height Unit Input/Output Identification Integrated Drive Electronics Internet Protocol Local Area Network Liquid Crystal Display Light-Emitting Diode MEG-Array Manually Retention Latch Network Interface Card 42 Service Supplement BX630 S2

43 Abbreviations NMI PCI PDA Non Maskable Interrupt Peripheral Component Interconnect Prefailure Detection and Analyzing POST Power On Self Test PSU RAID ROM SAN SAS SATA SCA SCSI SCU SFP Power Supply Unit Redundant Arrays of Independent Disks Read-Only Memory Storage Area Network Serial Attached SCSI Serial Advanced Technology Attachment Single Connector Attachment Small Computer System Interface Server Configuration Utility Small Form Factor Pluggable BX630 S2 Service Supplement 43

44 Abbreviations USB VGA VPD WOL Universal Serial Bus Video Graphics Adapter Vital Product Data Wakeup on LAN 44 Service Supplement BX630 S2

45 Index A add-on module 38 B BIOS recover 35 C consumables 15 control panel board 21 remove 22?? replace 21 D diagnostic LEDs 33 disposal, devices 16 documentation 5 recycling devices 16 return of devices 16 S saving energy 15 server blade open 20 remove from basic unit 18 service DVD 5 spare parts 38 T target group 5 E electrostatic-sensitive devices 14 environmental protection 15 ESD (modules with electrostaticsensitive devices) 14 L labels 15 legend 7 lithium battery 13 N notational conventions 7 notes on safety 11 P packaging 15 processors install 23 install/remove 23 R recovery BIOS 35 BX630 S2 Service Supplement 45

46

47 Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Computers. This new subsidiary of Fujitsu has been renamed Fujitsu Technology Solutions. This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed. Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions. Contact and support addresses will now be offered by Fujitsu Technology Solutions and have the The Internet pages of Fujitsu Technology Solutions are available at and the user documentation at Copyright Fujitsu Technology Solutions, 2009 Hinweise zum vorliegenden Dokument Zum 1. April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen. Diese neue Tochtergesellschaft von Fujitsu trägt seitdem den Namen Fujitsu Technology Solutions. Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion. Bitte beachten Sie, dass alle Firmenbezüge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions übergegangen sind. Kontakt- und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Die Internetseiten von Fujitsu Technology Solutions finden Sie unter und unter finden Sie die Benutzerdokumentation. Copyright Fujitsu Technology Solutions, 2009

PRIMERGY BX630 Scalable Server Blade

PRIMERGY BX630 Scalable Server Blade PRIMERGY PRIMERGY BX630 Scalable Server Blade Service Supplement Redakteur Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-??? Fax:

More information

The activities described in these upgrade instructions may only be performed by engineers or maintenance/technical staff.

The activities described in these upgrade instructions may only be performed by engineers or maintenance/technical staff. Introduction The upgrade instructions show how to remove the standard power supply and replace it with a hotplug power supply. The following steps only apply to the PRIMERGY 400 and 00 tower servers.!

More information

PRIMERGY BX920 S1 Server-Blade. Service Supplement

PRIMERGY BX920 S1 Server-Blade. Service Supplement PRIMERGY BX920 S1 Server-Blade Service Supplement Edition April 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

PRIMERGY S40-DF Capacity Extension

PRIMERGY S40-DF Capacity Extension Server PRIMERGY S40-DF Capacity Extension Xenia Fierley Siemens Nixdorf Informationssysteme AG ICP CS PS QM 3 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 636-47896 Fax: 0 700 /

More information

PRIMERGY BX630 S2 Scalable Server Blade. Options Guide

PRIMERGY BX630 S2 Scalable Server Blade. Options Guide PRIMERGY BX630 S2 Scalable Server Blade Options Guide Edition October 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback

More information

FibreCAT TXF Backup Subsystem. Service Supplement

FibreCAT TXF Backup Subsystem. Service Supplement FibreCAT TXF Backup Subsystem Service Supplement Edition October 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

chipdisk for RemoteView

chipdisk for RemoteView PRIMERGY chipdisk for RemoteView Xenia Fierley Siemens Nixdorf Informationssysteme AG Primergy 81730 Munich e-mail: Internet:DOCetc@mchp.siemens.de Tel.: (089) 636-47896 Fax: (++ 49) 89 6 36-4 87 17 U41102-J-Z156-1-74

More information

PRIMERGY BX620 S3 2-way Server Blade

PRIMERGY BX620 S3 2-way Server Blade PRIMERGY PRIMERGY BX620 S3 2-way Server Blade Options Guide Walter Dick Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (0 52 51)14888-12 Fax:

More information

PRIMERGY BX620 S6 Server Blade

PRIMERGY BX620 S6 Server Blade Service Supplement - English PRIMERGY BX620 S6 Server Blade Service Supplement September 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

PRIMERGY SX650 Storage Blade. Operating Manual

PRIMERGY SX650 Storage Blade. Operating Manual PRIMERGY SX650 Storage Blade Operating Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

PRIMERGY TX200 S3 Server

PRIMERGY TX200 S3 Server PRIMERGY PRIMERGY TX200 S3 Server Service Supplement Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: (++49) 700

More information

PRIMERGY Econel 200 S2 Server

PRIMERGY Econel 200 S2 Server PRIMERGY PRIMERGY Econel 200 S2 Server Options Guide Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-155 Fax: (++49) 700

More information

PRIMERGY Econel 100 Server System

PRIMERGY Econel 100 Server System PRIMERGY PRIMERGY Econel 100 Server System Service Supplement Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (0 89) 61 001-155 Fax:

More information

This symbol is followed by supplementary information, remarks and tips.

This symbol is followed by supplementary information, remarks and tips. Introduction This Technical Manual describes the system boards of the PRIMERGY 870 server systems, which can be equipped with up to four Intel Xeon processors. You may find further information in the description

More information

PRIMERGY TX150 S5 Server

PRIMERGY TX150 S5 Server PRIMERGY PRIMERGY TX150 S5 Server Service Supplement Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: (++49) 700

More information

PRIMERGY RX200 S3 Server. Options Guide

PRIMERGY RX200 S3 Server. Options Guide PRIMERGY RX200 S3 Server Options Guide Edition August 2006 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY TX120 S2 Server. Service Supplement

PRIMERGY TX120 S2 Server. Service Supplement PRIMERGY TX120 S2 Server Service Supplement Edition July 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved

Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved Fujitsu Siemens Computers GmbH DRV (BS2000/OSD) Version 3.1A November 2005 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved Release Notice DRV V3.1A 1 General 2 1.1

More information

PRIMERGY Econel 100 Server System

PRIMERGY Econel 100 Server System PRIMERGY PRIMERGY Econel 100 Server System Options Guide Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (0 89) 61 001-155 Fax: (++49)

More information

PRIMERGY RX100 S3 Server System

PRIMERGY RX100 S3 Server System PRIMERGY PRIMERGY RX100 S3 Server System Options Guide Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: (++49)

More information

FUJITSU SIEMENS COMPUTERS. Release Notice PCMX (LINUX-S390) V6.0A. Table of Contents

FUJITSU SIEMENS COMPUTERS. Release Notice PCMX (LINUX-S390) V6.0A. Table of Contents FUJITSU SIEMENS COMPUTERS Release Notice PCMX (LINUX-S390) V6.0A Table of Contents 1 General 1.1 Documentation 2 Notes on product use 2.1 Software/hardware configuration 2.1.1 Operating system 2.2 Resource

More information

WebTransactions V7.1. Supplement

WebTransactions V7.1. Supplement WebTransactions V7.1 Supplement Edition: December 2006 This manual describes the new functions in WebTransactions V7.1. It is intended to supplement the WebTransactions V7.0 manuals. Comments Suggestions

More information

R E L E A S E N O T I C E C O S M O S T O O L S V A. (c) Fujitsu Siemens Computers GmbH 2001

R E L E A S E N O T I C E C O S M O S T O O L S V A. (c) Fujitsu Siemens Computers GmbH 2001 R E L E A S E N O T I C E C O S M O S T O O L S V 1 4. 0 A (c) Fujitsu Siemens Computers GmbH 2001 Word and Excel are registered trademarks of Microsoft Postscript is a registered trademark of Adobe Contents

More information

PRIMERGY 670 Converting Guide

PRIMERGY 670 Converting Guide PRIMERGY 670 Converting Guide Server Systems A26361-K531-Z101-1-7419 Edition March 1999 Copyright and Trademarks Intel and Pentium are registered trademarks of Intel Corporation, USA. NetWare and Novell

More information

Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved

Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved Fujitsu Siemens Computers GmbH SM2-TOOLS (BS2000/OSD) Version 7.5A Juli 2006 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved Release Notice SM2-TOOLS V7.5A 1 General

More information

PRIMERGY RX300 S2 Server System

PRIMERGY RX300 S2 Server System PRIMERGY PRIMERGY RX300 S2 Server System Monika Spanjaart Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001160 Fax: (++49) 700 / 372 00000

More information

Copyright (C) Fujitsu Siemens Computers GmbH 2008 All rights reserved

Copyright (C) Fujitsu Siemens Computers GmbH 2008 All rights reserved Fujitsu Siemens Computers GmbH XHCS-SYS (BS2000/OSD) Version 2.0A June 2008 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2008 All rights reserved Release Notice XHCS-SYS V2.0A 1 General

More information

PRIMERGY RX600 S4 Server. Service Supplement

PRIMERGY RX600 S4 Server. Service Supplement PRIMERGY RX600 S4 Server Service Supplement Edition December 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

PRIMERGY RX300 S4. Options Guide

PRIMERGY RX300 S4. Options Guide PRIMERGY RX300 S4 Options Guide Edition June 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our

More information

PRIMERGY TX600 S3 Server

PRIMERGY TX600 S3 Server PRIMERGY PRIMERGY TX600 S3 Server Options Guide Joachim Pichol Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (05251) 14888-18 Fax: (++49) 700

More information

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options CHAPTER 4 Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options This chapter provides instructions for installing, replacing, and removing various hardware options in your Cisco ADE

More information

PRIMERGY RX600 S3 Server

PRIMERGY RX600 S3 Server PRIMERGY PRIMERGY RX600 S3 Server Options Guide Joachim Pichol Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (05251) 148 88-18 Fax: 0 700 / 372

More information

Copyright (C) Fujitsu Siemens Computers GmbH 2004 All rights reserved

Copyright (C) Fujitsu Siemens Computers GmbH 2004 All rights reserved Fujitsu Siemens Computers GmbH A I D Version 3.1 November 2004 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2004 All rights reserved Release Notice AID V3.1 1 General....................

More information

PRIMERGY RX600 S3 SAS Server

PRIMERGY RX600 S3 SAS Server PRIMERGY PRIMERGY RX600 S3 SAS Server Options Guide Joachim Pichol Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (05251) 148 88-18 Fax: 0 700

More information

System Board D2619 for RX/TX300 S5. Technical Manual

System Board D2619 for RX/TX300 S5. Technical Manual System Board D2619 for RX/TX300 S5 Technical Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

System Board D2785 for TX120 S2. Technical Manual

System Board D2785 for TX120 S2. Technical Manual System Board D2785 for TX120 S2 Technical Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

System board D2004 for RX100 S3

System board D2004 for RX100 S3 PRIMERGY System board D2004 for RX100 S3 Technical manual Däschlein Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-155 Fax: (++49) 700

More information

PRIMERGY BX630 S2 Scalable Server Blade. Operating Manual

PRIMERGY BX630 S2 Scalable Server Blade. Operating Manual PRIMERGY BX630 S2 Scalable Server Blade Operating Manual Edition October 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback

More information

Produktfamilie PRIMERGY RX200 S2

Produktfamilie PRIMERGY RX200 S2 Produktfamilie PRIMERGY RX200 S2 D1790 Setup Utility Hans-Joachim Kneba Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: 05251/8-14865 Fax: (++49)

More information

System Board D2559 for TX150 S6. Technical Manual

System Board D2559 for TX150 S6. Technical Manual System Board D2559 for TX150 S6 Technical Manual Edition November 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

Fujitsu Siemens Computers. internet Value Edition. Version 1.0B. July Release Notice

Fujitsu Siemens Computers. internet Value Edition. Version 1.0B. July Release Notice Fujitsu Siemens Computers internet Value Edition Version 1.0B July 2002 Release Notice Copyright (C) Fujitsu Siemens Computers 2002 All rights reserved Release Notice internet Value Edition V1.0B 1 General.....................

More information

PRIMERGY TX150 S6 Server. Options Guide

PRIMERGY TX150 S6 Server. Options Guide PRIMERGY TX150 S6 Server Options Guide Edition June 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

Streamer DAT160 Half-Height 80GB/160GB, USB 2.0

Streamer DAT160 Half-Height 80GB/160GB, USB 2.0 User Guide English Streamer DAT160 Half-Height 80GB/160GB, USB 2.0 Streamer DAT160 Half-Height 80GB/160GB, USB 2.0 User Guide Edition November 2008 Comments Suggestions Corrections The User Documentation

More information

STREAMER VXA /320 GB

STREAMER VXA /320 GB Operating Manual English STREAMER VXA-320 160/320 GB Are there...... any technical problems or other questions you need clarified? Please contact our Help Desk (see warranty card). The latest information

More information

HP ProLiant MicroServer

HP ProLiant MicroServer HP ProLiant MicroServer Installation Sheet Part Number 615715-004 Panel door components Item Component 1 16 screws for HDD installation 2 4 screws for ODD installation 3 Screw driver Rear panel components

More information

PRIMERGY BX600 S2 Basic Unit. Operating Manual

PRIMERGY BX600 S2 Basic Unit. Operating Manual PRIMERGY BX600 S2 Basic Unit Operating Manual Edition March 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

Using Egenera Virtualized Boot Services

Using Egenera Virtualized Boot Services Using Egenera Virtualized Boot Services For BladeFrame BF400 S2 and BladeFrame BF200 Document Number 432-SB0045 September 2008 EVBS1.0_BF_1 Copyright Copyright 2008 Egenera, Inc. All rights reserved. This

More information

PRIMERGY BX922 S2 Server Blade

PRIMERGY BX922 S2 Server Blade Options Guide - us PRIMERGY BX922 S2 Server Blade Options Guide Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

System board D2020 for Econel 200

System board D2020 for Econel 200 Produktfamilie System board D2020 for Econel 200 Technical manual Redakteur Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-??? Fax: (++49)

More information

PRIMERGY BX600 10GbE LAN I/O Module (PCIe)

PRIMERGY BX600 10GbE LAN I/O Module (PCIe) Reference Guide PRIMERGY BX600 10GbE LAN I/O Module (PCIe) Microsoft Windows Server 2003 iscsiselect Reference Guide English PRIMERGY BX600 10GbE LAN I/O Module (PCIe) Microsoft Windows Server 2003 iscsiselect

More information

PRIMERGY RX300 S5. Service Supplement

PRIMERGY RX300 S5. Service Supplement PRIMERGY RX300 S5 Service Supplement Edition June 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

Copyright (C) Fujitsu Siemens Computers GmbH 2005 *3 All rights reserved *3

Copyright (C) Fujitsu Siemens Computers GmbH 2005 *3 All rights reserved *3 Fujitsu Siemens Computers GmbH CRTE (BS2000/OSD) Version 2.4C *4 October 2005 *4 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2005 *3 All rights reserved *3 Release Notice CRTE V2.4C 1 General.....................

More information

PRIMERGY Econel 200 S2 Server. Operating manual

PRIMERGY Econel 200 S2 Server. Operating manual PRIMERGY Econel 200 S2 Server Operating manual Edition March 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

Produktfamilie PRIMERGY RX800 S2

Produktfamilie PRIMERGY RX800 S2 Produktfamilie PRIMERGY RX800 S2 Options Guide Gottfried Staubach Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: 05251 14888-19 Fax: (++49) 700

More information

PRIMERGY TX150 S5 Server

PRIMERGY TX150 S5 Server PRIMERGY PRIMERGY TX150 S5 Server Options Guide Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: 0 700 / 372 00000 TX150

More information

User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC)

User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC) User Guide - English FUJITSU Software ServerView Suite Local Service Panels Local Service Concept (LSC) Last Edition August 2017 Comments Suggestions Corrections The User Documentation Department would

More information

PRIMERGY BX620 S2 2-way Server Blade

PRIMERGY BX620 S2 2-way Server Blade PRIMERGY PRIMERGY BX620 S2 2-way Server Blade Operating Manual Walter Dick Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (05251)8-14854 Fax:

More information

PRIMERGY TX120 Server. Operating Manual

PRIMERGY TX120 Server. Operating Manual PRIMERGY TX120 Server Operating Manual Edition July 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY TX300 S3 Server

PRIMERGY TX300 S3 Server PRIMERGY PRIMERGY TX300 S3 Server Options Guide Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: (++49) 700 /

More information

HP ProLiant DL165 G7 Server

HP ProLiant DL165 G7 Server HP ProLiant DL165 G7 Server Installation Instructions Part Number 601464-003 Identifying server components Front panel components Figure 1 Front Panel Components / 4 3.5 LFF HDD Item Description 1 Thumbscrews

More information

After completing this chapter, you will meet these objectives:

After completing this chapter, you will meet these objectives: 3.0 Introduction Assembling computers is a large part of a technician's job. As a technician, you will need to work in a logical, methodical manner when working with computer components. As with any learned

More information

PRIMERGY TX300 S4. Options Guide

PRIMERGY TX300 S4. Options Guide PRIMERGY TX300 S4 Options Guide Edition April 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our

More information

Modular RAID Controllers

Modular RAID Controllers User Guide - English Modular RAID Controllers "RAID 0/1 SAS based on LSI MegaRAID" "RAID 5/6 SAS based on LSI MegaRAID" "RAID Ctrl SAS 6G 0/1 (D2607)" "RAID Ctrl SAS 6G 5/6 512MB (D2616)" "PY SAS RAID

More information

PRIMERGY TX200 S3 Server. Operating Manual

PRIMERGY TX200 S3 Server. Operating Manual PRIMERGY TX200 S3 Server Operating Manual Edition June 2006 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY SX940 S1 Storage Blade

PRIMERGY SX940 S1 Storage Blade Operating manual - English PRIMERGY SX940 S1 Storage Blade Operating manual Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

PRIMERGY Econel 230R S1 Server. Operating manual

PRIMERGY Econel 230R S1 Server. Operating manual PRIMERGY Econel 230R S1 Server Operating manual Edition May 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x

Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x Last Updated: December 4, 2014 Use these instructions to replace the RAID battery backup unit (BBU)

More information

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter Industrial PC IPC191V2 General Operating, Maintenance and Installation Manual Hardware Platform Protocol Converter D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 78 Internet: http://www.ipcomm.de

More information

Industrial PC IPC191C2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

Industrial PC IPC191C2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter Industrial PC IPC191C2 General Operating, Maintenance and Installation Manual Hardware Platform Protocol Converter D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 74 Internet: http://www.ipcomm.de

More information

PRIMERGY RX300 S3 Server. Options Guide

PRIMERGY RX300 S3 Server. Options Guide PRIMERGY RX300 S3 Server Options Guide Edition June 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

Dell Inspiron XPS and Inspiron 9100 Service Manual

Dell Inspiron XPS and Inspiron 9100 Service Manual Dell Inspiron XPS and Inspiron 9100 Service Manual Dell Inspiron XPS and Inspiron 9100 Service Manual Before You Begin Memory Module, Mini PCI Card, and Devices System Components Subwoofer Bluetooth Card

More information

Release Information for FlexFrame V4.0A10 for SAP

Release Information for FlexFrame V4.0A10 for SAP Release Information for FlexFrame V4.0A10 for SAP Copyright 2008 Fujitsu Siemens Computers Table of Contents General... 1 Ordering... 1 Delivery... 1 Documentation... 2 Software Extensions / New Functionality...

More information

PRIMERGY RX200 Server System

PRIMERGY RX200 Server System PRIMERGY PRIMERGY RX200 Server System Operating Manual Xenia Fierley Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001--157 Fax: (++49) 700

More information

Emanate Master 1.3. Readme. Edition June 2000

Emanate Master 1.3. Readme. Edition June 2000 Solaris Emanate Master 1.3 Readme Redakteur Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 636-00000 Fax: (++49) 700 / 372 00001 Bestellnummer

More information

PRIMERGY TX120 S2 Server. Operating manual

PRIMERGY TX120 S2 Server. Operating manual PRIMERGY TX120 S2 Server Operating manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY RX200 S5. Operating Manual

PRIMERGY RX200 S5. Operating Manual PRIMERGY RX200 S5 Operating Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY RX100 S6 Server. Service Supplement

PRIMERGY RX100 S6 Server. Service Supplement PRIMERGY RX100 S6 Server Service Supplement Edition january 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

PRIMERGY TX300 S3 Server. Operating Manual

PRIMERGY TX300 S3 Server. Operating Manual PRIMERGY TX300 S3 Server Operating Manual Edition July 2006 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY SX910 S1 Storage Blade

PRIMERGY SX910 S1 Storage Blade Operating Manual - English PRIMERGY SX910 S1 Storage Blade Operating Manual Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

PRIMERGY RX600 S5 Server

PRIMERGY RX600 S5 Server Service Supplement - English PRIMERGY RX600 S5 Server Service Supplement June 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

System Board D2671 for RX200 S4. Technical Manual

System Board D2671 for RX200 S4. Technical Manual System Board D2671 for RX200 S4 Technical Manual Edition December 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

PRIMERGY CX400 S1 Server Enclosure

PRIMERGY CX400 S1 Server Enclosure Upgrade and Maintenance Manual - English PRIMERGY CX400 S1 Server Enclosure Upgrade and Maintenance Manual Edition December 2012 Comments Suggestions Corrections The User Documentation Department would

More information

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved.

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved. apple Service Source Xserve RAID 17 March 2003 2003 Apple Computer, Inc. All rights reserved. apple Service Source Basics Xserve RAID 2003 Apple Computer, Inc. All rights reserved. Overview Xserve RAID

More information

XPS 15 2-in-1. Service Manual. Computer Model: XPS Regulatory Model: P73F Regulatory Type: P73F001

XPS 15 2-in-1. Service Manual. Computer Model: XPS Regulatory Model: P73F Regulatory Type: P73F001 XPS 15 2-in-1 Service Manual Computer Model: XPS 15-9575 Regulatory Model: P73F Regulatory Type: P73F001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better

More information

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Order Number:

More information

PRIMERGY TX300 S4 Server. Options Guide

PRIMERGY TX300 S4 Server. Options Guide PRIMERGY TX300 S4 Server Options Guide Edition December 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY TX150 S5 Server. Operating Manual

PRIMERGY TX150 S5 Server. Operating Manual PRIMERGY TX150 S5 Server Operating Manual Edition august 2006 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY Econel 40. Operating manual. Introduction. Important notes. Preparing for use. Operation. Troubleshooting and tips.

PRIMERGY Econel 40. Operating manual. Introduction. Important notes. Preparing for use. Operation. Troubleshooting and tips. Introduction Important notes PRIMERGY Econel 40 Preparing for use Operation Operating manual Troubleshooting and tips System expansions Technical data Index April 2004 edition Microsoft, MS, MS-DOS, Windows,

More information

PRIMERGY TX300 Server System

PRIMERGY TX300 Server System PRIMERGY PRIMERGY TX300 Server System Operating Manual Xenia Fierley Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001157 Fax: 0 700 / 372

More information

PAN Manager Feature Summary

PAN Manager Feature Summary PAN Manager Feature Summary For BladeFrame BF400 S2 and BladeFrame BF200 Document Number 430-SB0073 August 2008 PM5.2_BF Copyright Copyright 2008 Egenera, Inc. All rights reserved. This document, and the

More information

Intel NUC Kit DN2820FYKH User Guide. Intel NUC Kit DN2820FYKH User Guide

Intel NUC Kit DN2820FYKH User Guide. Intel NUC Kit DN2820FYKH User Guide Intel NUC Kit DN2820FYKH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers and with the safety

More information

Rocsecure NE52 NAS System

Rocsecure NE52 NAS System Rocsecure NE52 NAS System Revision 1.0 Table of Contents Preface... 3 Before You Begin... 4 Safety Guidelines... 4 Packaging, Shipment and Delivery... 4 Chapter 1 Introduction... 5 1.1 Key Features...

More information

The MTC Autoloader FibreCAT TX24 - Use with OSD/XC at SX Servers -

The MTC Autoloader FibreCAT TX24 - Use with OSD/XC at SX Servers - The MTC Autoloader FibreCAT TX24 - Use with OSD/XC at SX Servers - Readme File Contents 1 Introduction...2 2 Characteristics...4 2.1 General Characteristics...4 2.2 Release with OSD/XC...4 2.3 Hardware,

More information

LAN Manager/X V2.2. (SINIX) SNMP Service. System Administator's Guide

LAN Manager/X V2.2. (SINIX) SNMP Service. System Administator's Guide LAN Manager/X V2.2 (SINIX) SNMP Service System Administator's Guide Is there anything you want to tell us about this manual? Please send us your comments, quoting the order number of the manual. Siemens

More information

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved.

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved. apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May 2004 2003 Apple Computer, Inc. All rights reserved. apple Service Source Basics Xserve RAID 2003 Apple Computer, Inc.

More information

PRIMERGY TX200 S4 Server. Operating manual

PRIMERGY TX200 S4 Server. Operating manual PRIMERGY TX200 S4 Server Operating manual Edition December 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

Intel NUC Kit NUC5i3MYHE & NUC5i5MYHE User Guide. Intel NUC Kit NUC5i3MYHE Intel NUC Kit NUC5i5MYHE User Guide

Intel NUC Kit NUC5i3MYHE & NUC5i5MYHE User Guide. Intel NUC Kit NUC5i3MYHE Intel NUC Kit NUC5i5MYHE User Guide Intel NUC Kit NUC5i3MYHE Intel NUC Kit NUC5i5MYHE User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers

More information

Intel NUC Kit D54250WYKH & D34010WYKH User Guide. Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide

Intel NUC Kit D54250WYKH & D34010WYKH User Guide. Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers

More information

G-MAX TM. ATX Series User s Manual

G-MAX TM. ATX Series User s Manual Copyright Notice Copyright 2001 Gigabyte Technology. All Rights Reserved. No part of this documentation, including but not limited to the products and software described in it, may be reproduced, transmitted,

More information

Intel NUC Kit NUC7i7BNH, NUC7i5BNH & NUC7i3BNH User Guide. Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide

Intel NUC Kit NUC7i7BNH, NUC7i5BNH & NUC7i3BNH User Guide. Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated

More information