Manual: Distribution Substation Manual (DSM) Section 1: Customer Supply Arrangements
|
|
- Maurice Robinson
- 5 years ago
- Views:
Transcription
1 Manual: Distribution Substation Manual (DSM) Section 1: Customer Supply Arrangements Standard Number: HPC-5DA
2 Document Control Author Name: Viswa Easwaran Position: Standards Engineer Document Owner (May also be the Process Owner) Name: Justin Murphy Position: Manager Asset & Works Approved By * Name: Justin Murphy Position: Manager Asset & Works Date Created/Last Updated July 2013 Review Frequency ** 3 yearly Next Review Date ** July 2016 * Shall be the Process Owner and is the person assigned authority and responsibility for managing the whole process, end-to-end, which may extend across more than one division and/or functions, in order to deliver agreed business results. ** Frequency period is dependent upon circumstances maximum is 5 years from last issue, review, or revision whichever is the latest. If left blank, the default shall be 1 year unless otherwise specified. Revision Control Revision Date Description 0 12/07/2013 Original Issue Manager Assets & Works Manager Engineering Services STAKEHOLDERS The following positions shall be consulted if an update or review is required: Manager Engineering Systems Planning DM# Page 2 of 21 Print Date 15/07/2013
3 TABLE OF CONTENTS 1 PURPOSE SCOPE CONTENTS Index of Drawings REFERENCE DOCUMENT REVISION INFORMATION... 6 DM# Page 3 of 21 Print Date 15/07/2013
4 1 PURPOSE This Standard specifies the connection arrangements that shall be used to meet the electricity requirements of customers supplied at either low voltage (LV) (up to 4000 kva) or alternatively at medium voltage (MV). Connection arrangements, options for achieving higher than normal levels of reliability, together with the required high and low voltage electrical protection devices are included. This Standard supersedes the Western Power Document (record DMS# ] previously in use by Horizon Power since disaggregation. 2 SCOPE This Standard covers the following arrangements: Low voltage connection arrangements to be used for customer electricity supply up to 4000 kva, including the maximum consumers mains sizes and electrical protection devices that shall be used; Medium voltage connection arrangements to be used for customer electricity supply at medium voltage supply; District, Sole use and Customer Owned Substation arrangements, required to provide for the customers present and future load requirements; Arrangements available to provide higher levels of reliability to meet customers required supply reliability requirements. DM# Page 4 of 21 Print Date 15/07/2013
5 3 CONTENTS 3.1 Index of Drawings Drawing Number Drawing Title DSM-1-01 Legend DSM-1-02 Transformer & LV Feeder Ground Mounted Fusing District Substations DSM-1-03 DSM-1-04 DSM-1-05 DSM-1-06 Transformer & LV Feeder Overhead Fusing Isolation Transformer Overhead and RMU Fusing Discrete LV Load Below 315 A Customer s MSB Non Contiguous Customer Supplied From Shared LV Street Circuit Discrete LV Load Up To 315 A Customer s MSB Non Contiguous Customer Supplied From Dedicated LV Street Circuit Discrete LV Load Up To 1310 A Customer s MSB Contiguous Customer Supplied From Dedicated LV Circuit Discrete LV Load Up To 2000 A Customer s MSB Contiguous Customer Supplied From Dedicated LV Circuit Sole Use Substations DSM-1-07 Discrete LV Load Up To 1310 A DSM-1-08 DSM-1-09 Customer s MSB Contiguous Customer Supplied From Dedicated Transformer Discrete LV Load Up To 2625 A Customer s MSB Contiguous Customer Supplied From Dedicated Transformers Discrete LV Load Up To 5250 A Customer s MSB Contiguous Customer Supplied From Dedicated Transformers Customer Owned Substations DSM-1-10 Customer MV Metering Ground Mounted Overhead and Outdoor Ground Mounted Outdoor and Indoor DM# Page 5 of 21 Print Date 15/07/2013
6 4 REFERENCE DOCUMENT The following Reference Documents have been used to prepare this Standard: Doc Ref. Document Title Record No DM# Distribution Substation Manual - Section 1 Customer Substation Arrangements (Superseded) Publisher Horizon Power Western Australian Distribution Connections Manual Regional Power & Electricity Networks Corporation 5 REVISION INFORMATION (Informative) Horizon Power has endeavoured to provide standards of the highest quality and would appreciate notification if any errors are found or even queries raised. Each Standard makes use of its own comment sheet which is maintained throughout the life of the standard, which lists all comments made by stakeholders regarding the standard. A comment sheet found in DM: can be used to record any errors or queries found in or pertaining to this standard, which can then be addressed whenever the standard gets reviewed. Date Rev No. Notes 0 12/07/2013 Original Issue DM# Page 6 of 21 Print Date 15/07/2013
7 DM# Page 7 of 21 Print Date 15/07/2013
8 DM# Page 8 of 21 Print Date 15/07/2013
9 DM# Page 9 of 21 Print Date 15/07/2013
10 DM# Page 10 of 21 Print Date 15/07/2013
11 DM# Page 11 of 21 Print Date 15/07/2013
12 DM# Page 12 of 21 Print Date 15/07/2013
13 DM# Page 13 of 21 Print Date 15/07/2013
14 DM# Page 14 of 21 Print Date 15/07/2013
15 DM# Page 15 of 21 Print Date 15/07/2013
16 DM# Page 16 of 21 Print Date 15/07/2013
17 DM# Page 17 of 21 Print Date 15/07/2013
18 DM# Page 18 of 21 Print Date 15/07/2013
19 DM# Page 19 of 21 Print Date 15/07/2013
20 DM# Page 20 of 21 Print Date 15/07/2013
21 . DM# Page 21 of 21 Print Date 15/07/2013
Manual: Distribution Substation Manual (DSM) Section 4: Equipment Installation Guide
Manual: Distribution Substation Manual (DSM) Section 4: Equipment Installation Guide Standard Number: HPC-5DA-07-0004-2012 Document Control Author Name: Viswa Easwaran Position: Standards Engineer Document
More informationManual: Distribution Substation Manual (DSM) Section 5: Substation Fire Protection Requirements
Manual: Distribution Substation Manual (DSM) Section 5: Substation Fire Protection Requirements Standard Number: HPC-5DA-07-0005- Document Control Author Name: Viswa Easwaran Position: Standards Engineer
More informationDistribution Substation Manual (DSM) Section 6: Miscellaneous
Distribution Substation Manual (DSM) Section 6: Miscellaneous Standard Number: HPC-5DA-07-0006-2012 Document Control Author Name: Viswa Easwaran Position: Standards Engineer Document Owner Name: Justin
More informationHPC-9DJ
Guideline General Application of Switching Devices on Distribution Networks Standard Number: HPC-2AA-07-0001-2012 Document Control Author Name: Anthony Seneviratne Position: Senior Standards Engineer Document
More informationNetwork Asset Design Standard HV SUBSTATION FEEDER EXIT CIRCUITS ISOLATION POLICY
Network Asset Design Standard HV SUBSTATION FEEDER EXIT CIRCUITS ISOLATION POLICY Original Issue: September 2007 Prepared by: Lee Chan & Rob Rogerson This Revision: 0 October 2007 Date For Next Review:
More informationDistribution Substation Manual (DSM) Section 8 Distribution Automation
(DSM) Section 8 Distribution Automation July 2010 Document release information Client Project name Western Power Distribution Substation Manual Document number 8 Document title Revision status Distribution
More informationRecording and Reporting of High Voltage and Low Voltage Switching
1 SCOPE This document details the procedures to be adopted prior to, during, and on completion of Switching operations, and details the manner in which HV and LV Switching shall be recorded in order to
More informationEDS MW AND MVAR TRANSDUCER CONNECTION
Document Number: EDS 05-5001 Network(s): Summary: ENINEERIN DESIN STANDARD EDS 05-5001 MW AND MVAR TRANSDUCER CONNECTION EPN, LPN, SPN This standard details the convention to be used when wiring MW and
More informationPeace Region Petroleum Show Complete Site Map. May, Floor plan is intended for the sole use of our Clients and is subject to change.
70 70 705 707 709 7 7 75 77 79 7 7 08 06 0 0 0 0 0 0 09 8 0 06 0 0 0 00 WO 008 006 00 0 8 6 0 08 06 9 7 5 9 7 5 09 8 0 07 05 6 09 07 05 0 0 009 007 005 00 00 07 0 8 6 0 08 06 9 7 5 9 7 5 09 8 6 6 07 0
More informationPOWER GRID AUTOMATION. Pág.. n. RMU Automation
POWER GRID AUTOMATION RMU Automation Distribution Network Non-Controlled Secondary Distribution Systems Distribution Network RMU Automation - Levels RMU Automation - RTU / FRTU SMART CONTROLLER Monitoring
More informationECS LUCY GEMINI 3 CONFIGURATION PROCEDURE
Document Number: ECS 05-9541 Network(s): Summary: ENGINEERING CONSTRUCTION STANDARD ECS 05-9541 LUCY GEMINI 3 CONFIGURATION PROCEDURE EPN, LPN, SPN This document details the configuration procedure for
More informationSuperseding REVISED SHEET NO. 34D-8 REVISED SHEET NO. 34D-8 Effective May 27, 2010 Effective December 3, 2011
Superseding REVISED SHEET NO. 34D-8 REVISED SHEET NO. 34D-8 2. Initial Technical Review a. The following flowchart provides, for illustrative purposes, the major steps in the Initial Technical Review process:
More informationEBB PILOT FOR THE LIVE CONNECTION OF UNMETERED EQUIPMENT TO OVERHEAD LINES
Network(s): Summary: ENGINEERING BULLETIN EBB 08-0061 PILOT FOR THE LIVE CONNECTION OF UNMETERED EQUIPMENT TO OVERHEAD LINES EPN, SPN This bulletin provides a framework for the pilot scheme for unmetered
More informationOur Power & Control line of Business offers solutions that safely distribute power to your home or business. Our product range includes Low/Medium
Our Power & Control line of Business offers solutions that safely distribute power to your home or business. Our product range includes Low/Medium Voltage Panels and Enclosures designed and built with
More informationPackage Substation. The efficient solution for your electrical distribution network
Package Substation The efficient solution for your electrical distribution network Why Prefabricated Substations? Biosco, safe and effective substations Safety: A fully tested electrical equipment > Much
More informationNetwork Configuration Document Selection for New Substations Framework
Network Configuration Document Selection for New Substations Current version: 20/06/2018 EXTERNAL USE Page 1 of 14 Table of contents 1. Introduction... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 References...
More informationQuotation Accuracy Scheme FOR SMALL CONNECTIONS. How to Challenge the Accuracy of your Quotation
Quotation Accuracy Scheme FOR SMALL CONNECTIONS How to Challenge the Accuracy of your Quotation Contents 1. General Information... 3 2. Scope... 3 3. How to check the accuracy of your Quotation... 4 4.
More informationSOUTHERN COMPANY DISTRIBUTION INTERCONNECTION POLICY
SOUTHERN COMPANY DISTRIBUTION INTERCONNECTION POLICY Inverter Based Generators 25 kw and This document contains the interconnection requirements for inverter based generators, 25 kw and smaller, that operate
More informationDESIGN PRACTICE NOTE NEGATIVE BUSBAR SHUNTS
Approval Amendment Record Approval Date Version Description 27/05/2013 1 Initial issue under MTM. PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION Page 1 of 6 Table of Contents
More informationDocument C0. Use for:
Date: July 27, 2015 Document C0 Use for: Connection of Electric Generation that will operate with an Open Transition (Category 1) between the Ameren System and the Generator or operate with a Synchronized
More informationDocument Owner: Name: Phil Langlois Department: Lead Electrical Engineer
MAINTENANCE STANDARDS SPECIFICATION TITLE Power System Study Procedure VALE # Ontario Operations MPROC-50003 VALE # October 14, 2016 PAGE 1/14 Rev 3 Training Code (not applicable) Document Owner: Name:
More informationThird Generation System of the Future
Third Generation System of the Future Reza Ghafurian Consolidated Edison Company of New York 1 Company Overview Electric, gas, and steam regulated utility Supplying New York City and Westchester County
More informationEDS LV CUSTOMER UNMETERED SUPPLIES
Document Number: EDS 08-2102 Network(s): Summary: ENGINEERING DESIGN STANDARD EDS 08-2102 LV CUSTOMER UNMETERED SUPPLIES EPN, LPN, SPN This standard details the requirements for unmetered single-phase
More informationECP SECONDARY SUBSTATION COMMISSIONING PROCEDURE
Document Number: ECP 11-0501 Network(s): Summary: ENGINEERING COMMISSIONING PROCEDURE ECP 11-0501 SECONDARY SUBSTATION COMMISSIONING PROCEDURE EPN, LPN, SPN This procedure details the end-to-end process
More informationMemorandum. This memorandum requires Board action. EXECUTIVE SUMMARY
California Independent System Operator Corporation Memorandum To: ISO Board of Governors From: Keith Casey, Vice President, Market & Infrastructure Development Date: May 21, 2014 Re: Decision on interconnection
More informationEngineering Recommendation G87 Issue
PRODUCED BY THE OPERATIONS DIRECTORATE OF ENERGY NETWORKS ASSOCIATION Engineering Recommendation G87 Issue 2-2015 Guidelines for the Provision of Low Voltage Connections to Multiple Occupancy Buildings
More informationDemonstration of the UPGRID project urban network of the future
Demonstration of the UPGRID project urban network of the future SŁAWOMIR NOSKE, DOMINIK FALKOWSKI ENERGA-OPERATOR SA e-mail: {slawomir.noske/dominik.falkowski}@energa.pl 1. Introduction Sustainable development,
More informationKEDS DSO Development Plan. George Karagutoff, KEDS CEO Prishtina, Kosovo 20 March, 2018
KEDS DSO Development Plan George Karagutoff, KEDS CEO Prishtina, Kosovo 20 March, 2018 1 INVESTMENTS AT A GLANCE KEDS begun its operations after the successful unbundling of Distribution and Supply business
More information1.0 Executive Summary
Statement of Work - 1 - Power and Cooling Assessment for Data Center Professional Services Service 1.0 Executive Summary Table of Contents 1.0 Executive Summary 2.0 Features & Benefits 3.0 Details of Service
More informationSapphire Wind Farm 330/33kV Substation
Signature projects: Projects: Project Edison AusNet Sapphire Wind Farm 330/33kV Substation TransGrid Zinfra constructed 330/33kV substation and transmission line as part of the cut in works for the Sapphire
More informationIn data sheets and application notes which still contain NXP or Philips Semiconductors references, use the references to Nexperia, as shown below.
Important notice Dear Customer, On 7 February 2017 the former NXP Standard Product business became a new company with the tradename Nexperia. Nexperia is an industry leading supplier of Discrete, Logic
More informationMn/DOT CADD DATA Standards General Information
Mn/DOT CADD DATA Standards General Information PREFACE The scope of this web-site is to document and standardize the Minnesota Department of Transportation s CADD (computer aided drafting and design file
More informationABB Digital medium-voltage switchgear
NAMIBIA AMEU/AEDU MARCH 2018 ABB Digital medium-voltage switchgear Barry Addinall UniGear Digital Contents 1. Digital switchgear 2. Complexity of Distribution networks 3. New technologies using digital
More informationLow forward voltage Ultra small SMD plastic package Low capacitance Flat leads: excellent coplanarity and improved thermal behavior.
Rev. 01 14 September 2004 Product data sheet 1. Product profile 1.1 General description Planar Schottky barrier triple diode with an integrated guard ring for stress protection. Three electrically isolated
More informationSolar Combiner Enclosure
Installation Instructions Solar Combiner Enclosure Catalog Numbers 1000-SB006, 1000-SB012 Topic Page Description 1 Important Safety Instructions 3 Nameplate Data 4 Planning for Installation 4 Install the
More informationENGINEERING AND SERVICES FIRM THAT SPECIALIZES IN HYDROELECTRIC POWER AND CONTROL SYSTEM DESIGN, OUR TEAM OF PROFESSIONALS HAVE WORKED TOGETHER
smallhydro PRIME ENGINEERING LIMITED IS AN ELECTRICAL ENGINEERING AND SERVICES FIRM THAT SPECIALIZES IN HYDROELECTRIC POWER AND CONTROL SYSTEM DESIGN, IMPLEMENTATION AND MAINTENANCE. OUR TEAM OF PROFESSIONALS
More informationStandard Development Timeline
Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective. Description of Current Draft
More informationFault and outage management
WEBINAR, SEPTEMBER 2017 Distribution Automation for electrical grids Fault and outage management Alain Aurus, Theodoros Oikonomou, Yasmine Vögele Introduction Facility Management Use the detach button
More informationDistribution Management System Open++ Opera v.3.3. User Manual
Distribution Management System Open++ Opera v.3.3 User Manual 1MRS 751464-MUM Issued: 31.12.1999 Version: D/29.8.2003 Program Revision: 3.3D We reserve the right to change data without prior notice. User
More informationName: Denis Deschamps Position: Maintenance Business Process Specialist Department: Base Metals
MPROC-2008 207-08-07 of 8 Training Code (If applicable): Document Owner: Name: Denis Deschamps Position: Maintenance Business Process Specialist Department: Base Metals Table of Contents.0 PURPOSE... 2
More informationLow forward voltage Ultra small SMD plastic package Low capacitance Flat leads: excellent coplanarity and improved thermal behavior
Rev. 02 15 January 2010 Product data sheet 1. Product profile 1.1 General description Planar Schottky barrier triple diode with an integrated guard ring for stress protection. Three electrically isolated
More informationAlberta Reliability Standard Cyber Security Incident Reporting and Response Planning CIP-008-AB-5
A. Introduction Consultation Draft April 5, 2016 1. Title: 2. Number: 3. Purpose: To mitigate the risk to the reliable operation of the bulk electric system as the result of a cyber security incident by
More informationSensitive and Selective Ground-Fault Protection in Ungrounded MV Networks Using the DPU-2000R with the Directional-Sensitive-Earth Fault Feature
ABB Application Note Substation Automation and Protection Division DPU2000R AN-80D-01 Sensitive and Selective Ground-Fault Protection in Ungrounded MV Networks Using the DPU-2000R with the Directional-Sensitive-Earth
More informationVHF variable capacitance double diode. Electronic tuning in FM radio applications.
Rev. 03 1 July 2004 Product data sheet 1. Product profile 1.1 General description The is a variable capacitance double diode with a common cathode, fabricated in planar technology and encapsulated in the
More informationSECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 26 28 16 (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Individually Mounted Switches and Circuit Breakers Used for the following: a. Service
More informationSeries 8000 RF Signal Switch Solution
RF Signal Switch Solution Operation Manual Operation Manual, Part Number 07508000 006, Rev. B, Oct 7, 2014 All technical data and specifications in this publication are subject to change without prior
More informationB-1-1. Janet L. Fraser Director, Regulatory Affairs Phone: Fax:
B-- Janet L. Fraser Director, Regulatory Affairs Phone: 0-- Fax: 0-- E-mail: janet.fraser@bctc.com October 00 Ms. Erica Hamilton Commission Secretary British Columbia Utilities Commission 00 Howe Street,
More informationRef No: N Date: December 29, Lighting Products No. 49. Call us today! Effective Date: December 31, Apply Before December 9, 2007
Ref No: N06-084 Date: December 29, 2006 Lighting Products No. 49 Effective Date: December 31, 2008 Call us today! We can help you stay on top of changes that will affect your Certification! 1-866-797-4272
More informationGoddard Procedures and Guidelines
Goddard Procedures and Guidelines DIRECTIVE NO.: GPG 1410.1 APPROVED BY Signature: Original Signed by NAME: A. V. Diaz TITLE: Director Responsible Office: 230/Logistics Management Division Title: DIRECTIVES
More informationIntelliTeam II Automatic Restoration System
No system is too complex to automate with... IntelliTeam II Automatic Restoration System Introduced in 1997, the IntelliTeam Automatic Restoration System was the first product of its kind. Using peer-to-peer
More informationMF1 MOA4 S50. Contactless Chip Card Module Specification. This document gives specifications for the product MF1 MOA4 S50.
Rev. 3.2 19 December 2006 Product data sheet 083032 PUBLIC 1. General description 1.1 Addendum This document gives specifications for the product. The is the integrated circuit MF1 ICS50 in the package
More informationElectric Sample Form No Agreement for Unmetered Low Wattage Equipment Connected to Customer-Owned Street Light Facilities
Pacific Gas and Electric Company San Francisco, California U 39 Revised Cal. P.U.C. Sheet No. 32135-E Cancelling Revised Cal. P.U.C. Sheet No. 27053-E Electric Sample Form No. 79-1048 Agreement for Unmetered
More informationPRC Coordination of Protection Systems for Performance During Faults
PRC-027-1 Coordination of Protection Systems for Performance During Faults A. Introduction 1. Title: Coordination of Protection Systems for Performance During Faults 2. Number: PRC-027-1 3. Purpose: To
More informationAWS D16.2M/D16.2:2007 An American National Standard. Guide for Components of Robotic and Automatic Arc Welding Installations
An American National Standard Guide for Components of Robotic and Automatic Arc Welding Installations An American National Standard Approved by the American National Standards Institute August 25, 2006
More informationBalancing and Settlement Code BSC PROCEDURE
Balancing and Settlement Code BSC PROCEDURE Registration of Transmission System Boundary Points, Grid Supply Points, GSP Groups and Distribution Systems Connection Points BSCP25 Version 8.0 Date: 29 June
More informationMARKET PROCESS DESIGN. MPD 10 - Market Process for Re-Energisation
MARKET PROCESS DESIGN MPD 10 - Market Process for Re-Energisation TABLE OF CONTENTS 1 INTRODUCTION... 3 1.1 SCOPE... 3 1.2 HISTORY OF CHANGES... 3 2 PROCESS MAP... 5 2.1 PROCESS DESCRIPTION... 8 3 SUPPLEMENTARY
More informationMARKET PROCESS DESIGN. MPD New Distribution Connected Participant Generator
MARKET PROCESS DESIGN MPD 07 1.2 New Distribution Connected Participant TABLE OF CONTENTS TABLE OF CONTENTS... 2 1. INTRODUCTION... 3 1.1 SCOPE... 3 1.2 HISTORY OF CHANGES... 3 2. PROCESS MAP... 6 2.1
More informationStandard Development Timeline
Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective. Description of Current Draft
More informationFuel and Odometer Report Catalog
Fuel and Odometer Report Catalog Fuel and Odometer Report Catalog 1 Introduction... 4 Terminology... 5 Reports Detail Listing Report... 7 Summary Listing Report... 9 MPG Report... 11 Latest Odometer Report...
More informationResidential 1-Line Multifamily Instructions. User s Manual APPROVED. Copyright 2016 Durand & Associates. Page 1
Residential 1-Line 2017 Multifamily Instructions APPROVED User s Manual Copyright 2016 Durand & Associates Page 1 Using Residential 1-Line 2017 with Excel Excel 1997-2003 This product was designed with
More informationSubstation Workshop. 7 th February 2018
Substation Workshop 7 th February 2018 1 Agenda Welcome and Introductions Antony White Substation Design Overview Andy Moore Question & Answer Session Break 1500kVA Transformers James Devriendt & Andy
More information(Above 100km Distance) (Streetlight Pole) (Above 100km Distance) (Streetlight Pole)
Part 9 Miscellaneous Drawing Register Number Description M1-1 SSN Network Device with LV Aerial Supply (ABC) Arrangement M1-2 SSN Network Device with LV Aerial Supply Arrangement M1-3 SSN Network Device
More informationLevel 2, 3 and 4 Interconnection Application for Certified, Inverter Based Generating Facilities Not Greater than 2MW
Level 2, 3 and 4 Interconnection Application for Certified, Inverter Based Generating Facilities Not Greater than 2MW The Customer Generator applicant ("Applicant") hereby makes application to the T &
More informationEDS SCADA NUMBERING SYSTEM
Document Number: EDS 05-9007 Network(s): Summary: EPN, LPN, SPN ENGINEERING DESIGN STANDARD EDS 05-9007 SCADA NUMBERING SYSTEM This standard describes the system for numbering SCADA wiring within switchgear
More informationNational Load Despatch Centre Power System Operation Corporation
Module on Procedure for Data Collection National Load Despatch Centre Power System Operation Corporation Background Algorithms/ Processes AC Load flow and transmission losses Slack bus determination- Average
More informationIt is acceptable to place all required information in the main element (such as G4010) and delete the sub-elements provided in this template.
6. ENGINEERING SYSTEMS REQUIREMENTS G40 SITE ELECTRICAL UTILITIES SYSTEMS REQUIREMENTS SITE ELECTRICAL UTILITIES TEMPLATE 02/18 Instructions for using this template: There are template files for each UNIFORMAT
More informationCOOPER POWER SERIES. Fusing Equipment Catalog Data CA132064EN. Effective February 2018 Supersedes January 2014 (240-50)
Fusing Equipment Catalog Data CA132064EN Supersedes January 2014 (240-50) COOPER POWER SERIES Table of contents Attention....3 Eaton is in the process of updating part numbers and technical data due to
More informationOC IEEE IAS/PES Meeting February 21, 2013
San Diego International Airport: Building For The Future, Through Underground Distribution Automation and SCADA OC IEEE IAS/PES Meeting February 21, 2013 1 Presenter: Randy Denton, PE Under Ground Utility
More informationSuperseding SHEET NO. 34C-51 REVISED SHEET NO. 34C-51 Effective May 27, 2010 Effective December 3, 2011
Superseding SHEET NO. 34C-51 REVISED SHEET NO. 34C-51 INTERCONNECTION APPLICATION FOR ALL BUT UL1741 CERTIFIED INVERTER BASED SYSTEMS LESS THAN 10 KW In addition to the information provided below, a complete
More informationBlock I/O Cat. No IOBA and -IOBB User Manual
User Manual Because of the variety of uses for this product and because of the differences between solid state products and electromechanical products, those responsible for applying and using this product
More informationMESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM
Engineering Specification Electrical Networks TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V Version: 1 Issued: March 2014 Owner: Electrical Networks Asset
More informationJussi Ahola, ABB Oy A self healing power system for the accurate fault location and zone concept T&D Smart Grids Europe 2012
Jussi Ahola, ABB Oy A self healing power system for the accurate fault location and zone concept T&D Smart Grids Europe 2012 October 16, 2012 Slide 1 Introduction Why self-healing? Needs to improvements
More informationMARKET PROCEDURE: METER DATA SUBMISSIONS
MARKET PROCEDURE: METER DATA SUBMISSIONS PREPARED BY: Market Operations (WA) DOCUMENT REF: VERSION: 3.0 EFFECTIVE DATE: 30 November 2015 STATUS: FINAL Approved for distribution and use by: APPROVED BY:
More informationEDS LONDON 33KV DISTRIBUTION NETWORK DESIGN AND CUSTOMER SUPPLIES
Network(s): Summary: ENGINEERING DESIGN STANDARD EDS 08-0150 LONDON 33KV DISTRIBUTION NETWORK DESIGN AND CUSTOMER SUPPLIES LPN This standard provides guidelines for the development of the 33kV distribution
More information1510 MOTOR CONTROLLERS
SECTION 262913- MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of contract, including general and supplementary conditions and Division 1 specification section,
More informationDisturbance Monitoring and
PRC-002-2 R1 Notification Disturbance Monitoring and Reporting Requirements Compliance Spring Workshop May 10, 2017 Objectives This presentation will discuss: Requirement R1 Part 1.2 notifications Definition
More informationEDS KV, GRID AND PRIMARY SYSTEM PROTECTION AND CONTROL SCHEMES
Network(s): Summary: ENGINEERING DESIGN STANDARD EDS 05-0001 132KV, GRID AND PRIMARY SYSTEM PROTECTION AND CONTROL SCHEMES EPN, LPN, SPN This engineering design standard describes the requirements for
More informationStarter and Circuit Breaker Application with PowerFlex 7000
Application Technique Starter and Circuit Breaker Application with PowerFlex 7000 Bulletins 7000A, 7000, 7000L Topic Page General Precautions 2 Document Scope 2 Purpose 3 Drive Associated MV Starters and
More informationMARKET PROCESS DESIGN. MPD 05 - Market Process for New NQH Metered Connection
MARKET PROCESS DESIGN MPD 05 - Market Process for New NQH Metered Connection TABLE OF CONTENTS 1. INTRODUCTION... 3 1.1 SCOPE... 3 1.2 HISTORY OF CHANGES... 3 2. PROCESS MAP... 5 2.1 PROCESS DESCRIPTION...
More informationIn data sheets and application notes which still contain NXP or Philips Semiconductors references, use the references to Nexperia, as shown below.
Important notice Dear Customer, On 7 February 2017 the former NXP Standard Product business became a new company with the tradename Nexperia. Nexperia is an industry leading supplier of Discrete, Logic
More informationBID. Electronically Submitting a Building Permit Application Using COJ s Building Inspection Division s Electronic Permitting and Plan Review System
COJ s Building Inspection Division Electronically Submitting a Building Permit Using COJ s Building Inspection Division s Electronic Permitting and Plan Review System Updated 1/5/2015 CONTENTS Status Definitions
More informationXXXX. Bear Creek Hydro Generation Project. Interconnection Facilities Study
XXXX Bear Creek Hydro Generation Project Interconnection Facilities Study Report No. SPA 2005-33 August 2005 System Planning (Lower Mainland & Vancouver Island) British Columbia Transmission Corporation
More informationSIEMENS 8DJH 11/22 kv Ring Main Units
POWER AUTOMATION TECHNOLOGIES SIEMENS 8DJH 11/22 kv Ring Main Units Overview of Outdoor and Indoor solutions 01 02 Transformer Kiosk Indoor on Base Absorber Class A 03 07 Outdoor Class A Outdoor Class
More informationQueens/Brooklyn Lot Info Users Guide TWO WAYS TO REACH LOT INFO FROM STRATUS: 1. Search Stratus Public Records, then click Lot Info button
Queens/Brooklyn Lot Info Users Guide TWO WAYS TO REACH LOT INFO FROM STRATUS: 1. Search Stratus Public Records, then click Lot Info button 2. Click on Lot Info link on Public Records search menu page Both
More informationIn data sheets and application notes which still contain NXP or Philips Semiconductors references, use the references to Nexperia, as shown below.
Important notice Dear Customer, On 7 February 2017 the former NXP Standard Product business became a new company with the tradename Nexperia. Nexperia is an industry leading supplier of Discrete, Logic
More informationIn data sheets and application notes which still contain NXP or Philips Semiconductors references, use the references to Nexperia, as shown below.
Important notice Dear Customer, On 7 February 2017 the former NXP Standard Product business became a new company with the tradename Nexperia. Nexperia is an industry leading supplier of Discrete, Logic
More informationPRTR5V0U2X. 1. Product profile. Ultra low capacitance double rail-to-rail ESD protection diode in SOT143B. 1.1 General description. 1.
in SOT143B Rev. 01 22 September 2005 Product data sheet 1. Product profile 1.1 General description Ultra low capacitance double rail-to-rail ElectroStatic Discharge (ESD) protection diode in a small SOT143B
More informationEngineering Document Control
Division / Business Unit: Function: Document Type: Enterprise Services All Disciplines Procedure Engineering Document Control Applicability ARTC Network Wide SMS Publication Requirement Internal / External
More informationSource-Transfer Application Guide
S&C Model 6802 Automatic Switch Control Source-Transfer Application Guide Table of Contents Section Page Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this
More informationStandard Version: 2 Released: 15/12/2016
1. Foreword This standard forms part of Energex s safe system of work and outlines key roles, responsibilities and procedures for all persons switching or working on the isolated Energex Low Voltage (LV)
More informationTrendmaster* Galvanic Isolator
162459-01 Trendmaster* Galvanic Isolator Product Datasheet Bently Nevada* Asset Condition Monitoring Description The Trendmaster Galvanic Isolator enables the Trendmaster system to connect to intrinsically
More informationIn data sheets and application notes which still contain NXP or Philips Semiconductors references, use the references to Nexperia, as shown below.
Important notice Dear Customer, On 7 February 2017 the former NXP Standard Product business became a new company with the tradename Nexperia. Nexperia is an industry leading supplier of Discrete, Logic
More informationSiemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A
Switch Disconnectors Introduction Overview All key product features at a glance Compliant with IEC/EN 60439-1, IEC/EN 6094-3 Voltage levels up to 690 V AC Rated operational current from 160 A to 2000 A
More information1.0 Executive Summary. 2.0 Features and Benefits
Table of Contents 1.0 EXECUTIVE SUMMARY 2.0 FEATURES AND BENEFITS 3.0 DETAILS OF SERVICE 4.0 Deliverable 5.0 Exclusions 6.0 SCOPE OF RESPONSIBILITY 7.0 PROJECT WORK DETAILS 8.0 ORDERING INFORMATION 9.0
More informationSOUTH TEXAS ELECTRIC COOPERATIVE, INC.
SOUTH TEXAS ELECTRIC COOPERATIVE, INC. P.O. Box 119 Nursery, Texas 77976 (361) 575-6491 Fax (361) 576-1433 Transmission Interconnection Requirements Table of Contents I. Introduction II. Interconnection
More informationPMEG1030EH; PMEG1030EJ
Rev. 04 15 January 2010 Product data sheet 1. Product profile 1.1 General description Planar Maximum Efficiency General Application (MEGA) Schottky barrier rectifiers with an integrated guard ring for
More informationADVANCED. Protection Co-ordination. H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E
ADVANCED Protection Co-ordination H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E www.ictd.ae ictd@ictd.ae Course Introduction: Distribution Networks are designed to serve loads in a
More informationCAPABILITY STATEMENT. A full list of our services.
CAPABILITY STATEMENT A full list of our services. About Us MVLV Power Solutions Pty Ltd is a privately owned Western Australian based company, specialising in the Design and Manufacture of Electrical Switchboards
More informationTitle System Substation Commissioning Tests. Reference Number PCP 07 - (RIC Standard: EP SP)
Discipline Engineering Standard - NSW Category Electrical Title s Reference Number PCP 07 - (RIC Standard: EP 99 00 00 02 SP) Document Control Status Date Prepared Reviewed Endorsed Approved Mar 05 Standards
More informationDRAFT. Cyber Security Communications between Control Centers. March May Technical Rationale and Justification for Reliability Standard CIP-012-1
DRAFT Cyber Security Communications between Control Centers Technical Rationale and Justification for Reliability Standard CIP-012-1 March May 2018 NERC Report Title Report Date I Table of Contents Preface...
More information