APPENDIX B.7B TRANSFORMATION APPROACH AND METHODOLOGY. for COUNTY ATTACHMENT K

Size: px
Start display at page:

Download "APPENDIX B.7B TRANSFORMATION APPROACH AND METHODOLOGY. for COUNTY ATTACHMENT K"

Transcription

1 APPENDIX B.7B TRANSFORMATION APPROACH AND METHODOLOGY fr COUNTY Ats Cunty f Orange MSA fr IT Services Page 1 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

2 Cntents 1.0 Overview Objective Apprach and Methdlgy Schedule Peple Transfrmatin Team Transfrmatin Gvernance Mdel Develp Cmmunicatins Plan Staffing Plan Stakehlders Cunty f Orange Vendr Prcess Phases Waves Site Surveys Transfrmatin and Pst Transfrmatin Supprt fr L & J Agencies Operatinal Readiness Supplemental Management Plans Cmmunicatins Management Plan Risk Management Plan Change Management Plan Tls Prgram Prtal Technlgy Data Netwrk Transfrmatin Netwrk Infrastructure Overview Netwrk Devices and Security Firewall Transfrmatin Datacenter LAN Infrastructure Cre Sites Infrastructure Class 1 On-Net Ats Cunty f Orange MSA fr IT Services Page 2 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

3 5.2.5 Class 1 Sites - Off-Net Class 2 Sites - Off-Net and Cunty Fiber Sites Class 3 Sites Wide Area Netwrk Circuits Vice Netwrk Transfrmatin Overview Hsted VOIP envirnment Hardware/Hsting envirnment Hsted VOIP envirnment - VOIP Mdules/Sftware Sftphne Deplyment Calling Seven Digit Dialing Vic Vice Cnferencing Cmputer Telephny Integratin Recrding Devices Cnferencing Phnes Current VOIP System Integratin L & JA Cnverged Netwrk Overview Sites Public Defender Overview Public Defender Vic Slutin Organizatinal Change Appendix Ats Cunty f Orange MSA fr IT Services Page 3 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

4 1.0 Overview 1.1 Objective Transfrmatin is where the Vendr mves the Cunty frm its legacy data and vice netwrks int a cnverged netwrk utilizing Vice ver Internet Prtcl (VIP). Cmplete all Transfrmatin milestnes by mutually agreed-n dates. This bjective will be measured by the delivery f the defined artifacts in Amendment 1 milestne six (6) by submissin & apprval f Quality Review Frm (QRF) fr a given subset f cmpleted sites in the Transfrmatin Prject. Minimize impact and risk t Cunty f Orange business peratins, IT departments and user cmmunity. Cntinue a slid relatinship between Cunty f Orange and Vendr accunt team. The TMO Client Satisfactin Survey will measure the success f this bjective. Slidify the lng-term strategic relatinship; fstering a strng cmmitment tward the cmmn gals 1.2 Apprach and Methdlgy Vendr will incrprate a disciplined prject management apprach and methdlgy utilizing Micrsft Prject t create the necessary prject artifacts. Vendr will utilize the results created during the Transitin Prject t drive transfrmatin Data Netwrk Vendr will transfrm the Cunty legacy data netwrk infrastructure t a cnverged vice/data infrastructure utilizing Cisc netwrk equipment, technlgy and netwrk prtcls required t supprt the deplyment f Cnverged Netwrk and VIP services fr Cunty End Users. Transfrmatin includes the installatin f a new telecmmunicatins netwrk and hardware t supprt a cnverged set f services. Vendr will deply the data netwrk in a phased apprach. This begins with implementing the 10 cre sites creating the backbne fr the entire netwrk. Once the initial phase is cmplete and the cre backbne is established additinal in-scpe sites will be added in a phased apprach. Prject Lifecycle fr Netwrk Services Transfrmatin Vendr emplys a standard system develpment & implementatin apprach t each defined discipline within the Transfrmatin. The fllwing prvides a general descriptin f the apprach applied t each area f this Transfrmatin: Analysis and Design: Develp and finalize netwrk architecture design Develp and finalize security architecture design Develp and cllabrate with Cunty f Orange n transfrmatin schedule Develp and cllabrate with Cunty f Orange n transfrmatin apprach plan Develp and cllabrate with Cunty f Orange n transfrmatin acceptance criteria Ats Cunty f Orange MSA fr IT Services Page 4 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

5 Jint reviews f design dcument, apprach plan and schedule fr sign-ff by Cunty f Orange Cnstruct: Develp cutver implementatin plans n a rlling phase apprach Initiate prcurement fr Netwrk Cre and Phase 0 site cutvers Initiate prcurement f security devices Validate training requirements fr supprt persnnel Develp cmmunicatin plans Develp test and quality assurance plans Implement: Vendr installs netwrk cre infrastructure Vendr rlls ut test site(s) Site migratin t Cisc netwrk systems Site migratin t Surcefire IDS/IPS mnitring system Site migratins t remaining security tls, as apprpriate Address prcess imprvement and risk mitigatin n an nging basis Vendr will implement industry best practice fr implementatin using Vendr and Custmer agreed upn strategy fr minimizing impact risk, utages and Security issues fr the netwrk rllut Analysis and Design Discvery - Vendr will identify current envirnment infrmatin and btain knwledge f existing prcesses fr Cunty f Orange services supprt. This will be accmplished thrugh assignments f Transfrmatin team members and knwledge transfer sessins. Obtain system/wrkflw Inputs-Vendr will btain input frm Cunty f Orange business wrkflw, plicy and prcedures, incident management, and change management and reprting. Identify in-scpe systems Identify in-scpe security systems and agencies t be mnitred Identify ticket escalatin prcedures Identify security incident escalatin prcedures Verify maintenance cntracts exist fr supprted systems Identify list f systems t be mnitred Identify list f systems t be mnitred by security prducts Review Cunty f Orange reprting requirements Identify inventry fr each site Cnstruct Establish and dcument main pints f cntact fr Cunty f Orange Develpment - Vendr will build and implement the necessary hardware, sftware and business wrkflw prcesses necessary t supprt the defined requirements Prcurement Initiate prcurement f hardware, sftware, r services required t cmplete the deliverable Ats Cunty f Orange MSA fr IT Services Page 5 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

6 Testing and Quality Assurance - This includes develpment f test plans, cnfiguratin test, user acceptance test, and G/N G decisin Dcument all netwrk devices at each Cunty lcatin Define and dcument each vendr s ticketing prcedures Define and dcument security incident handling prcedures Dcument hurs f peratin fr each supprted site Cmpleted letter f agency fr Cunty f Orange telecm vendrs Define wh will prvide reprts, hw they will be prvided, when they will be prvided Prvide data engineering with IP addresses t be mnitred Obtain devices t be mnitred by security tls Cnfirm back-up schedules Develp plan fr necessary cre infrastructure t be installed in the Orange Cunty Data Center (OCDC) and Building 12 Develp plan fr migratin f sites t new cre infrastructure Develp plan fr migratin f sites t new security tls Develp rll-back plans Review data with Cunty f Orange in supprt f establishing budget cst allcatins Generate and maintain knwledge dcuments and make these available t the Cunty f Orange upn request fr the duratin f the Transfrmatin prject. Create cmprehensive vendr list Dcument in-flight prjects, deliverables, and assciated due dates Develp cmmunicatin plan with the Cunty Implement Fllwing a G decisin based n successful testing and apprval, and with the cncurrence f Cunty IT, the implemented slutin is put int prductin. During pst implementatin, a defined burn-in perid will extend fr an agreed upn duratin where all activities assciated with the implemented slutin are clsely mnitred and issues r incidents are addressed by the Transfrmatin team. Once this burn-in perid is ver, VIP migratins are cleared t ccur. Verify Vendr netwrk engineers can access the Cunty f Orange netwrk systems Verify Vendr Security Operatins Center (SOC) engineers can access security tls Order netwrk hardware Build required netwrk cmpnents in OCDC and Building 12 Execute training prgram Migrate sites t new infrastructure Migrate sites t IDS/IPS and security tls, as apprpriate Migrate legacy security tls t new envirnment Install new security tls in new envirnment Execute site test plan t verify migratin Execute security test plan t verify migratins Verify Netwrk Tls are mnitring all future state equipment Verify Security Tls are mnitring future state equipment, as apprpriate Validate required Design, As-built(s) and Training dcumentatin is cmplete and dcumented in the QRF fr the site Validate vendr specific in-scpe back-ups are wrking Clse Ats Cunty f Orange MSA fr IT Services Page 6 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

7 Obtain custmer cncurrence that deliverables have been met Execute the site decmmissining prcedure, including the de-install and decmmissin f legacy phne equipment and the inventry f legacy phne equipment Obtain Agency and Cunty I.T. apprval t clse prject Cmplete administrative prject clse activities Obtain Accunt Team Sign-Off Obtain Client Sign-Off Vice Netwrk Vendr will deply three instances f the HCS envirnment in the Vendr s Dallas and Pittsburgh data centers. These platfrms will prvide bth physical and gegraphic redundancy. Vendr will perfrm VIP site deplyments using a wave apprach that fllws the data netwrk cnnectivity and netwrk equipment transfrmatin. During each wave, Vendr will be cnfiguring the Hsted Cisc HCS platfrms t supprt the IP-based vice services. Vendr will als be remtely staging and cnfiguring new vice equipment and prviding nsite installatin and cnfiguratin f new IP-phnes fr all users. Implementatin will cnsist f building the new clusters, data cllectin f the Nrtel systems, building these remte lcatins and phnes in the new clusters, and migrating the remte site t the new cluster. Implementatin will als cnsist f creating a new Vice Service queue, testing n-call prcedures, verifying remte cnnectivity t the supprted hardware, defining escalatin prcedures, and Change/Prblem Management administratin. Prject Lifecycle fr Vice Services Transfrmatin Vendr emplys a standard system develpment & implementatin apprach t each defined discipline within the Transfrmatin. The fllwing prvides a general descriptin f the apprach applied t each area f this Transfrmatin: Analysis and Design: Develp and finalize the VIP architecture design Develp and cllabrate with Cunty f Orange n transfrmatin schedule Develp and cllabrate with Cunty f Orange n transfrmatin apprach plan Develp and cllabrate with Cunty f Orange n transfrmatin acceptance criteria Jint reviews f design dcument, apprach plan and schedule fr sign-ff by Cunty f Orange Cnstruct: Develp cutver implementatin plans n a rlling wave apprach Initiate prcurement fr VIP Cre and Wave 0 site cutvers Validate end user training requirements and develp training material and prcesses Validate training requirements fr supprt persnnel Develp cmmunicatin plans Develp test and quality assurance plans Develp rll-back plans Ats Cunty f Orange MSA fr IT Services Page 7 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

8 Implement: Vendr will bserve industry best practice fr implementatin using Vendr and Custmer agreed upn strategy fr minimizing impact risk and utages fr the VIP rllut. Vendr installs VIP cre infrastructure Vendr rlls ut test site(s), tailrs prcess fr Cunty f Orange culture PBX and end user migratin t Cisc VIP systems Address prcess imprvement and risk mitigatin n an nging basis Vendr will make available n-site end user training and training dcumentatin (including training slideware n SharePint and leave behind material ) as well as specialized training fr executives, executive assistants and ACD agents Analysis and Design Discvery - Vendr will identify current envirnment infrmatin and btain knwledge f existing prcesses fr Cunty f Orange services supprt. This will be accmplished thrugh assignments f Transfrmatin team members and knwledge transfer sessins. Obtain system/wrkflw Inputs-Vendr will btain input frm Cunty f Orange business wrkflw, plicy and prcedures, incident management, and change management, reprting and IMAC. Identify in-scpe vice services and vice systems cnnected t the legacy PBX, including vic , call recrding, ACDs, IVRs, PA systems, security alarms and any ther vice equipment Identify ticket escalatin prcedures Verify maintenance cntracts exist fr supprted systems Identify list f systems t be mnitred Review Cunty f Orange vice reprting requirements Identify inventry fr each site Cnstruct Establish and dcument main pints f cntact fr Cunty f Orange Develpment - Vendr will build and implement the necessary hardware, sftware and business wrkflw prcesses necessary t supprt the defined requirements Prcurement Initiate prcurement f hardware, sftware, r services required t cmplete the deliverable Training Determine training requirements based n the existing knwledge base and the slutin t be implemented Develp training prgram and material Testing and Quality Assurance - This includes develpment f test plans, cnfiguratin test, user acceptance test, and G/N G decisin Dcument phne mdel, user, phne number per site fr every phne Dcument vic bxes and users per site Dcument Aut Attendant applicatins and scripts Dcument vice gateway dial-peers, vice resurces, and SRST fr each vice gateway Dcument analg gateway mdel, user, phne number per site fr every phne Ats Cunty f Orange MSA fr IT Services Page 8 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

9 Define and dcument each vendr s ticketing prcedures Dcument hurs f peratin fr each supprted site Cmpleted letter f agency fr Cunty f Orange telecm vendrs Define wh will prvide reprts, hw they will be prvided, when they will be prvided Prvide data engineering with IP addresses t be mnitred Cnfirm back-up schedules Develp plan fr installing clusters int Dallas and Pittsburgh data centers Develp plan fr necessary cre infrastructure t be installed in the Orange Cunty Data Center (OCDC) and Building 12 Develp plan fr migratin f sites t new clusters Review data with Cunty f Orange in supprt f establishing budget cst allcatins Generate and maintain knwledge dcuments and make these available t the Cunty f Orange upn request fr the duratin f the Transfrmatin prject. (VOIP rack diagrams, user training guides and Call Center guides) Review data with Cunty in supprt f establishing budget cst allcatins Create cmprehensive vendr list Dcument in-flight prjects, deliverables, and assciated due dates Gather NORTEL ACD requirements fr UCCX Develp Day 2 Rles and Respnsibilities with L&JA Develp cmmunicatin plan and pst-hyper care supprt with SAIC Implement Fllwing a G decisin based n successful testing and apprval, and with the cnsensus f the Agency and Cunty I.T., the implemented slutin is put int prductin. Verify Vendr vice engineers can access the Cunty f Orange vice systems Order vice hardware Build new clusters in Pittsburgh and Dallas data centers Build required telephny cmpnents in OCDC and Building 12 Baseline and build the sites in CUCM Imprt the phnes, gateways, and users int CUCM Imprt the users int Unity Cnnectin Build ACDs n new UCCX cluster Execute training prgram Migrate sites t new clusters Execute site test plan t verify migratin During pst implementatin, a defined Critical Care r Hypercare perid will extend fr an agreed upn duratin where all activities assciated with the implemented slutin are clsely mnitred and issues r incidents are addressed by the Transfrmatin team. Once this critical care perid is ver, incident management will be addressed by the defined peratinal supprt rganizatin. Verify Netwrk Tls are mnitring all future state equipment Validate required Design, As-built(s) and Training dcumentatin is cmplete Validate back-ups are wrking Clse Obtain Agency and Cunty I.T. cncurrence that deliverables have been met Obtain Agency and Cunty I.T. apprval t clse prject Ats Cunty f Orange MSA fr IT Services Page 9 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

10 Cmplete administrative prject clse activities, including cmpletin f QRF dcumentatin Fllw the prcedure fr decmmissining and inventry f legacy equipment Obtain Accunt Team Sign-Off Obtain Client Sign-Off Law and Justice Envirnments Vendr will deply hardware and sftware t meet the physical separatin requirements fr the Law and Justice agencies Public Defender Fr Public Defender sites, Vendr will physically separate their netwrks frm ther Cunty vice and data traffic. Public Defenders Unity (vice mail) will be built in the Orange Cunty Data Center (OCDC)/Public Defender HQ. Public Defender has chsen t utilize the vice encryptin capability fr all f its lcatins. 1.3 Schedule Transfrmatin Deliverables and Milestnes Please refer t the fllwing tw artefacts t btain this infrmatin: 1. Appendix B 1A - Transitin Plan 2. Appendix B-8B t Attachment B - Transfrmatin Deliverables and Milestne Lists Prgram Dependencies, Assumptins, Cnstraints and Risks Dependencies Cunty f Orange facility flr plans AD Read Permissins fr Single Sign On VIP and Administrative Assistant prgramming In Scpe Ancillary Infrmatin e.g. Call Recrding, Call Center, External Paging Cunty f Orange Facility readiness including Pwer, Space and Cling (changed t Cunty) In Scpe ACD Call Center Access t existing t PBX infrmatin Prting DID frm ATT t Subcntractr Site cntacts and access t all Cunty f Orange facilities t be transfrmed Vendr equipment prcurement New circuit prvisining New circuit prvisining int facility (Subcntractr) Cunty f Orange Facility readiness including Pwer, Space and Cling Cunty Dependencies Perfrm DID Assignments if necessary Cunty resurces fr requirements determinatin/validatin Cunty resurces fr building access and escrt duties Cunty resurces available fr timely apprvals f: site scpe sign-ffs legal agreements Ats Cunty f Orange MSA fr IT Services Page 10 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

11 Assumptins frmal apprvals-t-prceed Define prcess gverning hw we prcess ut-f-cycle/scpe requests frm Cunty Ensure Cunty f Orange Facility readiness including Pwer, Space and Cling Prvide Site cntacts and access t all Cunty f Orange facilities t be transfrmed Prvide Cunty f Orange facility flr plans Prvide AD Read Permissins fr Single Sign On Prvide VIP and Administrative Assistant prgramming details Vendr will be able t rely n Cunty f Orange emplyees t prvide access/crdinatin n flr plans, hurs, peratins and cntacts A 3rd party vendr wh has been vetted and apprved by OC I.T. will be used t prvide hands-n supprt where we can t use lcal Vendr staff SMS will be used fr all change/prblem management Vendr will als use the Cunty designated Service Desk (SAIC) Vendr will have access t Cunty f Orange facilities where Transfrmatin Prject wrk is being cnducted Cnstraints The data netwrk must be in place befre mnitring tls can be installed and tested The data netwrk must be in place in the data site befre the VIP clusters can be built The data netwrk must be in place fr remte management Cunty and Agency engagement and cmmunicatins cnstraints will be clearly defined by the Cunty Risks Lack f Cunty resurces fr building access and escrt duties culd cause delays Lack f prperly vetted and backgrund-checked Ats resurces culd cause delays Lack f Cunty resurces available fr timely apprvals f sign ffs and t prvide flr plans culd cause delays Lack f Cunty f Orange Facility readiness including Pwer, Space and Cling culd cause delays Issues with AT&T and Subcntractr DID Prting numbers Issues with access t existing PBX data 2.0 Peple 2.1 Transfrmatin Team Vendr will establish a Transfrmatin Team cnsisting f bth dedicated and leveraged resurces t implement the cnverged netwrk. Vendr Rle Prgram Executive Greg Mitchell Respnsibilities Prvides executive supprt fr transfrmatin gals and bjectives; Ats Cunty f Orange MSA fr IT Services Page 11 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

12 Reslves escalated issues Manages executive relatinships with the Cunty. Transfrmatin Manager Jhn Crckett SUL - Netwrk James Duley SUL Vice Keith Snyder SUL - Security Wes Kanamri Service Delivery Manager Ukesh Chand Respnsible fr Netwrk Transitin and Transfrmatin f utsurcing services including all transitin and transfrmatin deliverables, prject plan executin, status reprting and prgress; cmmunicatin with the Cunty stakehlders. Respnsible fr delivery executin fr the Data Netwrk Management Services and Cnverged Netwrk Management Services as Service Areas defined in Schedule 2A. This individual shall be a management interface and escalatin pint f cntact fr all matters relating t these Service Areas r subservice areas. Respnsible fr delivery executin fr the Vice Cmmunicatins Services and Cnverged Vice Management Services as Service Areas defined in Schedule 2A. This individual shall be a management interface and escalatin pint f cntact fr all matters relating t these Service Areas r subservice areas Respnsible fr delivery executin fr the Security Services, as Service Areas defined in Schedule 2A. This individual shall be a management interface and escalatin pint f cntact fr all matters relating t this Service Area. Oversees delivery f day-t-day peratinal. Manages develpment and implementatin f the prblem/incident, change, request, asset, and prcurement management interface prcesses; defines and implements perfrmance management prcedures, including definitin, develpment, and implementatin f peratinal and SLR reprting Manages develpment and delivery f cntent fr the management prtin f the plicies and prcedures manual; prvides QA functin fr all sectins f the manual; crdinates the Cunty s review and sign-ff n the manual; Manages the definitin, develpment, and implementatin f inflight prjects. 1. VIP Transfrmatin Manager Respnsible fr implementing the Vice ver IP Netwrk. Ats Cunty f Orange MSA fr IT Services Page 12 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

13 Michael Durk Netwrk Transfrmatin Manager Respnsible fr implementing the Data Netwrk. Garth Lwther 2.2 Transfrmatin Gvernance Mdel Vendr will train all Transfrmatin staff n the gvernance structure fr decisin making defined during Transitin. Vendr will assign select Transfrmatin staff t the apprpriate gvernance cmmittees including rles and respnsibilities specific t gvernance. 2.3 Develp Cmmunicatins Plan Vendr will implement the Transfrmatin specific elements f the cmmunicatin plan. The details f the plans will be dcumented under Appendix B.5 Cmmunicatin Plan. 2.4 Staffing Plan Vendr has identified key candidates fr psitins and will cmplete the fulfillment f Transfrmatin staff, including the Subcntractrs listed under Attachment I Subcntractrs. Our n-barding mdel requires backgrund investigatins fr certain key psitins and cnfrm t Cunty requirements. Vendr has included time in the prject t cmplete the fllwing required screenings: Backgrund check Drug testing Criminal backgrund screening In additin t these screenings, Vendr will carefully screen each candidate fr cmpetency and cultural fit within ur rganizatin and Cunty envirnment. Once the n-barding prcess fr the emplyee is cmplete, Vendr will engage in the fllwing majr transitin activities: Cmpletin f knwledge transfer- The knwledge transfer prcess will prvide a transitin f knwledge required t supprt the transfrmatin envirnments. Detailed knwledge transfer plan is prvided under Appendix B.6 Knwledge Transfer plan. Training staff n Vendr tls and prcesses 2.5 Stakehlders Cunty f Orange Name Charlie Eckstrm Rb Newtn Rle Interim CIO Transfrmatin Prgram Directr Ats Cunty f Orange MSA fr IT Services Page 13 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

14 KC Restenberg Gerge Marcs Vendr Brad Rich Greg Mitchell James Duley Keith Snyder Wes Kanamri Name Name Rle Operatins Directr Transfrmatin Prgram Manager Rle Executive Spnsr Accunt Executive Netwrk Service Unit Leader Vice Service Unit Leader Security Service Unit Leader 3.0 Prcess 3.1 Overview Vendr will adhere t all prcesses and prcedures develped during Transitin and develp additinal prcesses and prcedures where required during Transfrmatin. The Transfrmatin prcess is brken int phases and waves; Phases are data implementatins and Waves are vice implementatins. All Phases and Waves integrate with ITIL prcesses develped during Transitin. The data phase is a predecessr t the assciated vice wave. Vendr selected sites fr each phase based n their relatinship t the cre backbne. Sites in each wave are based n their relatinship t the assciated data phase. 3.2 Phases The data netwrk transfrmatin fr in-scpe sites will ccur in fur phases: 1. Phase 0 cre sites (backbne) 2. Phase 1 large sites and satellite sites 3. Phase 2 medium sites and satellite sites 4. Phase 3 remaining Class 3 sites Vendr selected sites fr each phase based n their relatinship t the cre backbne. 3.3 Waves The vice netwrk transfrmatin fr in-scpe sites will ccur in fur waves: 1. Wave 0 cre sites 2. Wave 1 large sites and satellite sites 3. Wave 2 medium sites and satellite sites 4. Wave 3 remaining Class 3 sites Sites in each wave are based n their relatinship t the assciated data phase. 3.4 Site Surveys Ats Cunty f Orange MSA fr IT Services Page 14 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

15 Vendr will perfrm Site Surveys 45 business days (r 74 calendar days) befre site migratins ccur. Site surveys include nsite visits, cabling build-uts if required, physical rack space assessments, and pwer requirement evaluatins. Site survey results and requirements will be shared with the Cunty within 3 days after the site survey allwing sufficient time fr building preparatin wrk t be perfrmed. Other preparatin tasks t be perfrmed during site surveys include site user lists (DID s, Names, phne mdels), call ruting patterns, phne and analg cunts. 3.5 Transfrmatin and Pst Transfrmatin Supprt fr L & J Agencies Upn cmpletin f Transitin, Vendr will prvide mnitring and netwrk management fr Cunty Enterprise WAN segments up t the L&J legacy netwrk pint f demark. Vendr will prcure, cnfigure, prvisin the circuits and install the in-scpe WAN and Vice equipment. Vendr will manage the transfrmed Cunty Enterprise WAN up t where it interfaces with L&J Agency netwrks. Fr the LAN equipment within each L&J Agency, Vendr will install, cnfigure, test and turnver the cnverged netwrk t L&J IT staff. The IT rganizatins within each L&J-designated Agency will be respnsible fr supprting their LAN and Vice steady-state infrastructures after transfrmatin. Vendr will maintain and supprt Cunty Enterprise ff-premise vice cmpnents fr L&J Agencies (excluding existing VIP systems f the Public Defender). L&J will crdinate with Vendr NOC fr the reslutin f any incidents r utages that invlve the Cunty s cnverged netwrk infrastructure. Vendr will prvide netwrk engineering supprt fr the L&J Agencies n a time-and-materials basis after Transfrmatin is cmpleted. 3.6 Operatinal Readiness Vendr will perfrm Operatinal Readiness t ensure peratins staff is prepared t accept the cnverged netwrk. 3.7 Supplemental Management Plans Fllwing is a summary descriptin f supplemental management plans that will be utilized, created and delivered by the Transfrmatin management team t manage prgram deliverables Cmmunicatins Management Plan The Cmmunicatins Management Plan defines the fllwing areas: Prgram structure including prgram gvernance, rganizatin and rles and respnsibilities Prgram cmmunicatins schedule Prgram cntacts Issue and actin management prcess Escalatin management prcess Risk Management Plan The Risk Management Plan defines the fllwing areas: Risk definitin Risk tracking tl Ats Cunty f Orange MSA fr IT Services Page 15 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

16 Page 16 f 37 ATTACHMENT K

17 Page 17 f 37 ATTACHMENT K

18 Page 18 f 37 ATTACHMENT K

19 required at each site within the required IDF and MDF wiring clsets. All cables will be tested and certified t meet specificatins and labeled accrding t Cunty standards. As part f Transfrmatin, Vendr will perfrm all hardware prcurement and nsite installatins, fiber build-uts fr diverse access int Cunty facilities, netwrk equipment staging and cnfiguratin, installatin f new netwrk cables and assciated wiring equipment, circuit prvisining and installatin, and will perfrm netwrk engineering and prductin testing at the OCDC. Dependencies, Assumptins, Cnstraints and Risks Dependencies Delivery f equipment per schedule Accurate inventry f all supprted systems Accurate infrmatin detailing the current Cunty netwrk (E2) Physical access t netwrk infrastructure in rder t cmplete the site surveys Security tls are dependent n cre netwrk functining and have internet cnnectivity The data netwrk must be in place and an agency migrated t the new netwrk befre mnitring can be tested Cunty agencies and SAIC prvide testers during migratin int new netwrk Cunty apprval f security services architecture in new netwrk n a timely manner Hrizntal cabling installatin Assumptins New Cre Netwrk up and available per schedule Delivery f vendr hardware is available and delivered n time Cunty Agencies and SAIC are available t migrate Security services t new netwrk Cunty will apprve security services architecture in a time manner Vendr persnnel and their sub-cntractrs will have access t all Cunty facilities Cnstraints New IDS/IPS and ther heuristic baselines will have t be determined each time a new agency is brught nt the Vendr netwrk Cunty Freeze calendar restricting timeframes t migrate security services t new netwrk Limited Cunty resurces t perfrm site surveys with Vendr Variable levels f detail and accuracy prvided by Cunty agencies Risks Mnitring tls will nt be available if the data netwrk is nt established by the required due date if hardware nt delivered n time The Vendr data netwrk is nt ready in the prpsed timeframe and/r internet cnnectivity cannt be established Cabling/infrastructure is nt ready in the prpsed timeframe, which delays migratin f legacy tls and installatin f new tls Vendr hardware nt delivered per schedule Cunty Agencies and SAIC are nt available t migrate security services t new netwrk Incmplete dcumentatin Cunty des nt apprve Security Services architecture in new netwrk Time needed t transfrm cabling infrastructure exceeds apprved schedule Additinal pwer requirements and the time t install new pwer Limited space fr equipment cnfiguratin/burn-in prir t installatin Inadequate envirnmental cntrls in IDF/MDF lcatins Ats Cunty f Orange MSA fr IT Services Page 19 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

20 Access t building fr build-uts t supprt Subcntractr infrastructure 5.2 Netwrk Infrastructure Overview Vendr will prvide a cmplete refresh t transfrm the Cunty s in-scpe WAN/LAN infrastructure. The slutin is built n Cisc ruting and switching equipment. All new equipment will be cvered under maintenance cntracts and nsite service will be prvided t ensure SLRs are met. Additinally, Vendr will prvide a pl f n-site spares within the Cunty. Vendr will cnnect sites with Subcntractr Metr Ethernet circuits where available. Sites that are nt cnnected thru Metr Ethernet access and are ff-net will either be cnnected with Cunty fiber r Subcntractr fiber access back t the data center. These sites will be cnfigured with dual Cisc ASR1002ruters that have redundant 1 GB interface mdules t supprt the Cunty requirements. Fr sites that have Cunty fiber segments, Vendr will prvisin a single circuit int the site and leverage the cunty fiber fr the redundant cnnectin required t meet SLA requirements. Dependencies, Assumptins, Cnstraints and Risks Dependencies Prper circuit prvisining with Subcntractr Warehuse lcatin t stre n-site equipment Assumptins TW Telecm Circuits will be delivered per schedule Availability f Cunty Fiber Cnstraints Limited ability fr Cunty Fiber t wrk as redundant netwrk cnnectivity N Cunty Fiber frm the OCDC t the Civic Center area t prvide adequate redundancy Risks Bandwidth prvisined thrugh Subcntractr Metr Ethernet may be ver r under subscribed Off-net sites circuit installatin culd be delayed Netwrk Devices and Security Vendr will cnfigure additinal firewall and security capabilities int the new Cisc ruters and switches that will be installed at each f the Class 1, 2 and 3 facilities. This equipment will allw firewall functinality and functins, such as VLANs, data/vice traffic segmentatin, VRFs and VPN tunneling t be available at remte facilities and eliminate the need fr a physical device t be lcated at the OCDC fr each agency. This will reduce the need fr extensive firewall administratin and large numbers f Access Cntrl Lists (ACLs), and reduce labr and supprt requirements. The Vendr implementatin team will wrk clsely with the Scpe 1 vendr and Cunty t ensure all security needs are cnsidered and mitigated during Transfrmatin. As each lcatin is transfrmed t its future state, Vendr will ensure all Vendr Scpe 2 managed devices and mnitring are integrated int the SEIM. Additinally, all prcesses and prcedures defined in Transitin will be applied. Ats Cunty f Orange MSA fr IT Services Page 20 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

21 The Vendr will prvide cntrls and measures t cntrl access, prtect against intrusin, malware, vulnerabilities, and data lss, blcking and filtering, encryptin, and plicy cmpliance. These netwrk and security tls will be installed lcally within the data center and prvide the supprt fr the legacy and transfrmed infrastructures. Additinally, all prcesses and prcedures defined in Transitin will be applied Firewall Transfrmatin Vendr will replace the current in-scpe firewall appliances with new Cisc ASA 5585 firewalls. These firewalls allw the creatin f virtual firewalls in each appliance that can be cnfigured fr individual Cunty agency segmentatin and security requirements. The virtual firewall envirnment addresses spfing, denial f service (DS) attacks, SNMP queries, ICMP attacks, and malicius traffic assciated with NIMDA-type viruses and illegal IP address spaces. Vendr will install tw sets f Cisc 5585s within the Orange Cunty Data Center (OCDC). These firewalls will be cnfigured with dual redundant access and failver as part f the data center LAN infrastructure and will mnitr all data traffic cming int r leaving the data center frm the Cunty and Agencies. The firewall replacement apprach cnsists f nine steps (fr added details- please see MS Prject Plan fr Transfrmatin): 1. Requirements analysis 2. Detailed design 3. Define critical practices 4. Establish netwrk mnitring 5. Cnfiguratin and build 6. Test 7. Migrate 8. Prvide peratin readiness and dcumentatin 9. Turn-ver t peratins Datacenter LAN Infrastructure The Vendr slutin utilizes a three-tier architecture fr the Orange Cunty Data Center LAN infrastructure t prvide all ruting/switching and security requirements fr the Cunty. Vendr will transfrm the current OCDC Brcade switching/ruting infrastructure and the existing internet/extranet infrastructures t supprt the future data/vice, IP telephny, netwrk Metr-Ethernet and MPLS cnnectivity and cnvergence requirements. Vendr will replace the legacy Brcade ruting /switching equipment at the data center and remte firewall appliances within the agencies with a three-tiered Cisc LAN infrastructure at the OCDC. This infrastructure cmprises a Cre Netwrk Layer that prvides switching/ruting functinality and switched native LAN Metr Ethernet cnnectivity fr Class 1 and Class 2 sites n the Time Warner carrier netwrk. Class 3 sites will be cnnected thru MPLS circuits and access int the Subcntractr carrier netwrk. The Distributin supprt Layer-2 agency 1GB fiber cnnectivity t the OCDC, internet/extranet segmentatin, Layer 3 ruting / switching, data/vice traffic tagging and ruting, and LAN Switch cnnectivity. The bundary Ats Cunty f Orange MSA fr IT Services Page 21 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

22 layer will supprt netwrk cnnectivity fr 1GB high-end servers, data center users, IP phnes, Internet/extranet appliances and netwrk management and mnitring tls. Tw ASR 1002 Ruters will be installed as Internet access ruters. These ruters will run BGP prtcl and handle lad balancing f internet traffic. The cre backbne f the netwrk will cnsist f ASR1004 ruters with 8GB diverse cnnectivity t the Time Warner Telecm carrier netwrk. These ruters will handle the cre ruting/switching requirements n the Subcntractr carrier netwrk between the Metr Ethernet and MPLS netwrks. A pair f Cisc Nexus 7010 Layer 3 switches will handle the cre ruting/switching requirements within the data center and the segmentatin f the LAN infrastructure thru VDCs which prvide redundant instances and interfaces. Cisc 5596 Switches will supprt all Layer-2 cnnectivity fr Cunty and Agency lcatins that utilize Cunty fiber access: Fur interfaces in each chassis will be cnnected t Subcntractr Metr Ethernet backbne netwrk (tw fr MPLS site cnnectivity and tw fr Cre Ring cnnectivity) Eight interfaces will be cnfigured between the tw Nexus 7010s t supprt lad balancing and redundancy Fur interfaces are cnfigured t supprt the ASA5585 Firewalls Eight interfaces t supprt the 5596 Distributin Switches (Side A) Eight interfaces t supprt the 5596 Distributin Switches (Side B) The remaining six 10 GB interfaces will be used t supprt cnnectivity f the Bundary Cisc 3850 switches that prvide the user cnnectivity and access int the data center The distributin layer f the data center LAN infrastructure will cnsist f tw redundant Cisc Nexus 5596 Layer 2 switches. The 1GB interfaces n the Cisc 5596 switches will be used t supprt Layer-2 and cunty fiber cnnectivity fr agency sites int the data center. In additin, these switches will prvide cnnectivity fr 22 Nexus 2248s internal switches and fur Cisc ASA 5585s firewall appliances within the data center LAN Infrastructure. This cnfiguratin f the Nexus 2248s will prvide fr GB switch prts fr LAN switch cnnectivity int the cre LAN Infrastructure. The ASA 5585s firewalls have been cnfigured as tw redundant pair f devices with diverse paths within the data center. The tw redundant pairs f Cisc ASA5585s will supprt Internal and External firewall requirements and rules. These appliances allw fr access cntrl between Agencies and access cntrl t the servers themselves n an agency-independent basis. The ASA5585s have the ability f cntexts, which are multiple firewall plicies n a single device. This allws firewall plicies t meet individual Agency requirements withut affecting ther plicies. This cnfiguratin supprts the requirements requested fr agency segmentatin and separatin f traffic. The bundary layer f the LAN infrastructure will be cnfigured with 12 Cisc Catalyst 3850X switches and six Cisc Catalyst 3850X-10GB switches. These switches will supprt user and device cnnectivity within the data center and can be cnfigured t supprt VLAN segmentatin fr individual data center LANs r IP phnes. Vendr netwrk engineers will wrk with the Cunty t cnfigure the lgical and physical segmentatin fr each agency. The Law and Justice agencies will have physical netwrk separatin f all data and vice traffic as required. Vendr will cnfigure a separate LAN segment within the OCDC t handle the cnnectivity requirements f the netwrk management, security and mnitring tls. These netwrk and security tls will be installed lcally within the data center and prvide the supprt fr the legacy and transfrmed infrastructures Cre Sites Infrastructure Class 1 On-Net Ats Cunty f Orange MSA fr IT Services Page 22 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

23 Fr Class 1 Sites, On-Net is defined as lcatins where Subcntractr has r will prvide their fiber directly int facilities. Current bundary ruters at the remte Cunty and Agency Headquarters lcatins will be refreshed with tw different equipment cnfiguratins depending n the WAN access the site requires int the cre netwrk. Sites that are netwrk cnnected n-net directly t the Subcntractr Metr Ethernet netwrk thru fiber access will be cnfigured with dual Cisc ASR1004 ruters with redundant 10GB interface mdules. All netwrk prcessing and switching functins will be handled within the Cre f the netwrk. The distributin layer will handle the server cnnectivity and prcessing functins, as well as supprting fiber access and remte sites cnnectivity in additin t supprting the security requirements fr segmentatin between agencies and access cntrl. The bundary layer will be cnfigured t supprt all user accesses (such as well as Internet, intranet, extranet, VPN and IP telephny) Class 1 Sites - Off-Net Fr Class 1 Sites Off-Net is defined as lcatins where Subcntractr utilizes a 3 rd party lcal exchange carriers (AT&T) fr entrance facilities (last mile access int facilities). Vendr will prvide new Cisc netwrking equipment fr all Class 1 sites. The sites will be cnfigured with dual Cisc ASR1002 ruters t supprt WAN cnnectivity back t the OCDC. The existing LAN edge switches that supprt user cnnectivity will be replaced with new Cisc switches with the designated IOS and interfaces capable f supprting Pwer ver Ethernet (PE) technlgy in additin t MPLS and the required netwrk prtcls fr data tagging, encryptin, VLANs and vice/data traffic segmentatin. Vendr will als be respnsible fr the installatin f Cisc 4507 LAN switches and Cisc 3850 switches with 1GB interface cards Class 2 Sites - Off-Net and Cunty Fiber Sites Fr Class 2 Sites Off-Net is defined as lcatins where Subcntractr use utilize a 3 rd party lcal exchange carriers (AT&T) fr entrance facilities (last mile access int facilities). These lcatins will be cnfigured and transfrmed with a single Cisc ASR1002 ruter. Each ruter will have dual netwrk circuits either thrugh existing Cunty fiber cnnectivity r Subcntractr MPLS circuits. The existing LAN switches at Class 2 sites will be replaced with new Cisc 4507 and Cisc 3850 LAN switches that will supprt netwrk requirements fr netwrk segmentatin and VLANs, and prvide 1 GB prts fr new IP phnes at each facility Class 3 Sites The Phase 3 transfrmatin will include the replacement f WAN ruters and LAN edge switches at each site. Sites will be cnnected t the Subcntractr netwrk thrugh MPLS clud-based technlgy and have been cnfigured with the required equipment and prtcls t supprt cnnectivity, encryptin, segmentatin and data/vice traffic priritizatin and remte management. Fr the WAN cnnectivity, Vendr will install Cisc 2951 vice-enabled ruters. Each ruter is designed t supprt IP-VPN MPLS access frm 1.45mbps-10mbps. All current LAN Edge switches at the Class 3 sites will be replaced with new Cisc switches capable f supprting PE, VLAN segmentatin and MPLS prtcls. Vendr will replace the existing LAN switches with Cisc 3850 switches at the larger Class 3 sites and Cisc 2960s LAN switches at the smaller sites Wide Area Netwrk Circuits Ats Cunty f Orange MSA fr IT Services Page 23 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

24 Vendr Netwrk Tplgy Overview The netwrk tplgy is architected t supprt data/vice cnvergence. This service delivery infrastructure is based n Cisc ruting, switching and IP-based unified cmmunicatins technlgy, which enables migratin frm legacy-based vice cmmunicatins. The tw circuit types delivered by Subcntractr are Metr-Ethernet and MPLS within a single carrier netwrk. Vendr will leverage existing Cunty fiber and fiber switching equipment where available t supprt cnverged netwrk cnnectivity requirements at large Cunty and Agency lcatins. Additinally, netwrk firewalls and security functinality have been included t prvide the necessary physical and lgical segmentatin f traffic and access fr Law & Justice agencies and peratins. Vendr will have respnsibility fr all new Subcntractr Metr Ethernet, Vice and MPLS Circuits, Fiber Switches and fiber build-ut csts fr new entrance facilities t supprt the diversity/redundancy requirements and service level metrics. As sites are migrated nt the new data netwrk frm Subcntractr, Vendr will wrk with the Cunty t establish a decmmissining prcess fr the existing AT&T circuits in place. AT&T circuits will nt be pulled r damaged withut Cunty apprval Class 1 Sites - On-Net and OCDC LAN/Security WAN The cre Class 1 facilities will be cnnected thrugh diverse 10 GB circuits t the Time Warner Metr Ethernet backbne. Vendr will install dual-ring cnnectivity and diverse path access fr the cnnectins int the data center and ther cre Class 1 facilities. This cnfiguratin will prvide redundancy and failver in case f a fiber cut r circuit utage. Vendr will build ut fiber circuits and lcal access int Class 1 On-Net facilities designated t be prvisined with Subcntractr 10GB circuits Class 1 Sites - Off-Net WAN Vendr will replace the current carrier circuits at these sites with Time Warner Metr Ethernet circuits at equivalent bandwidth t supprt availability and redundancy. Fr these sites Subcntractr des nt have entrance facilities built int the building. These lcatins will require the use f a Subcntractr 3 rd party carrier fr the lcal exchange access (AT&T) Class 2 Sites - Off-Net and Cunty Fiber Vendr will leverage the Cunty fiber cnnectivity where available at these sites fr ne f the required netwrk circuits int each facility. Vendr will replace the current carrier circuits at these sites with Time Warner Metr Ethernet circuits at equivalent bandwidth t supprt availability and redundancy. These circuits will prvide a diverse path ptin, either cnnectivity thrugh the Metr Ethernet netwrk r thrugh the MPLS netwrk in case f a circuit utage r fiber cut Class 3 Sites Class 3 sites will be re-engineered with a new Time Warner MPLS IP-VPN circuit that prvides cnnectivity int the Subcntractr MPLS netwrk. Vendr will cnfigure sites with T1 r NxT1 Metr Ethernet circuits, depending n the size f the site and the number f users at each lcatin. Vendr will implement SRST as part f managed vice services t prvide phne access thrugh the PSTN in the case f a WAN circuit utage. Ats Cunty f Orange MSA fr IT Services Page 24 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

25 5.2.9 LAN Cabling Upgrade all nn-standard cabling Vendr will upgrade all nn-standard cabling t the Cunty CAT6 standard, including patch cables that run between the LAN wall-jack and phne. Existing cables will be remved t prvide necessary access fr new cabling int raceways and cnduits within designated facilities. In raceways and/r cnduits where previusly existing cables are encuntered, Vendr will remve at least ne previusly existing cable frm that same raceway r cnduit fr each new cable Vendr installs. Vendr will certify, dress and label all cabling, patch panels and jacks t meet established Cunty standards within MDF and IDF lcatins, including terminatin f preexisting cabling fund t be nt yet terminated. Vendr has included 19,000 LAN cables fr replacement and upgrade t the Cunty CAT6 standard. Fewer LAN cables may be required nce infrmatin btained during site surveys is reviewed and Vendr will fllw the agreed upn change cntrl prcess t reduce any segments belw the 19,000 cables prpsed. On a prspective basis, beginning June 1, 2016, the Vendr agrees t prvide, as-built flr plans, under the same peratinal prcedures in place prir t June 1, 2016, but with the Vendr s additin f the representatin f thse cables that are certified by the Vendr under the terms f PCR # Existing LAN Cabling Certificatin Cunty has requested that, in certain circumstances, Vendr certify and supprt existing cable envirnments instead f upgrading t r installing new CAT6 per the Transfrmatin Design Specificatin. CAT5e and existing CAT6 cable are satisfactry t supprt the Gigabit Ethernet and Pwer ver Ethernet standards that will be utilized at the Cunty with the current Scpe 2 cnverged netwrk fferings prvided by Vendr, hwever, Vendr agrees t prvide nly CAT6 cable in prviding Services t the Cunty s LAN envirnments. Further, certain circumstances r cnditins may make it impractical t re-cable a building, e.g., the Cunty may have a shrt term lease and it wuld be t cstly t re-cable fr such a shrt duratin, r it may nt be practical t run new CAT6 cable in an envirnment because f asbests r ther hazardus r limiting factrs. The use f existing cabling is in cmpliance with the Cunty Standards Scpe f wrk: Re-certify f a maximum amunt f 7,000 existing cables s they can be attached t the Vendr cnverged data netwrk during the Transfrmatin Prject. A new Change Order will be required if this number is exceeded. Apprval frm the Cunty will be prvided using the Cabling Statement f Wrk (i.e. the cabling statement that accmpanies all transfrmatins) prir t the wrk being perfrmed. Certify that cables will pass the 1 GB certificatin tests (perfrmance) required t be supprted n the Cnverged netwrk. This certificatin prcess includes an end-tend test with utput that can be prvided upn request. See Appendix A fr the detailed specificatin tested when using the testing equipment. Nte: If the cable des nt pass this re-certificatin it will be required t be replaced with a new cable as part f the 19,000 until which time all the 19,000 cables have been deplyed. Once depleted, the new cable will be charged using 3.1 Fee Sheet, Netwrk Ats Cunty f Orange MSA fr IT Services Page 25 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

26 ADD Services Rate, Additinal LAN Cable Installatin & Additinal LAN Cable Installatin (Material) Unit Rates Cnditins: 1. Existing cables certified by Vendr will nt cunt twards the 19,000 cable resurce units included in the Transfrmatin Prject. 2. Netwrk Availability and Netwrk Perfrmance Service Level Requirements have n applicability t the re-certified LAN cables. 3. Incident Reslutin and Respnse Service Level Requirements, as articulated in the standard prblem reslutin respnsibilities defined in the Master Service Agreement, remain in effect. 4. Existing Cat6 cables can nly be used frm the user panel in clset t the ffice, cubical and cmmn area. 5. Repair r replacement f cable, patch panels, jacks r inserts is nt included in the initial scpe f wrk required t re-certify the cable. 6. Includes a patch cable at the time the end-pint is transfrmed t the cnverged netwrk Onging Supprt (Pst Transfrmatin): 1. Cable failure f re-certified cables determined by due diligence t be caused by nn-interrupted use within the facility will be Repaired/Replaced by Vendr at n additinal cst. 2. Cable failure determined t be caused by mis-use r natural causes (furniture mves, pest damage, fire) will nt be cvered after re-certificatin ccurs. If required, a separate wrk rder will be pened and price will be negtiated with the Cunty prir t the wrk being perfrmed. 3. Cable failure determined t be caused by Vendr r ne f its subcntractrs will be Vendr s respnsibility t repair/replace at n additinal cst. 4. Nrmal and custmary replacement f cable cmpnents such as biskets, face plates and cable cnnectrs nt determined t be caused by misuse r natural causes (furniture mves, pest damage, fire) will be repaired/replaced by Vendr at n additinal cst. 5. Onging Supprt utlined abve is applicable frm the date f certificatin t the end f the term f the Agreement (March 16, 2019). This excludes the extensin f the Term fr up t tw (2) additinal successive perids f nt mre than ne (1) year each Certificatin Tests Vendr will perfrm the fllwing tests using the testing instrument. Each re-certified statin cable will be tested fr the fllwing pursuant t the field test specificatins defined in ANSI/TIA- 568-C.2 Cmmercial Balanced Twisted-Pair Telecmmunicatins Cabling and Cmpnents Standard : a. Wire Map Ats Cunty f Orange MSA fr IT Services Page 26 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

27 b. Length c. Insertin Lss d. NEXT Lss e. PS NEXT Lss f. ACR-F Lss g. PS ACR-F Lss h. Return Lss i. Prpagatin Delay j. Delay Skew The Cunty is fully respnsible fr funding the cable hardware and installatin f LAN cabling needed by the Cunty in excess f the 19,000 cables referenced abve. Vendr's charges t the Cunty fr this additinal cabling ver and abve the 19,000 cable threshld shall be prvided and charged t the Cunty under Pass-Thrugh Fees as described in Sectin (Pass-Thrugh Fees) f Schedule 3 (Fees) Cunty Prvided Fiber Optic Cabling Vendr will test the Cunty s fiber. Fiber must meet r exceed the minimum transmissin specificatins as defined in ANSIITIAIEIA-568-C.3.Vendr will ntify the Cunty if any existing Cunty fiber des nt pass certificatin and will present the Cunty with an ptin t reslve the issue Once certified, the Cunty's fiber will be: 1. supprted by Vendr as is ther Vendr supprted fiber in the envirnment, 2. subject t Service Level Requirements, measurements and Fee Reductins Onging Supprt (Pst Transfrmatin): 1. failure f certified fiber, determined by due diligence t be caused by nn-interrupted use within the facility, will be repaired/replaced by Vender. 2. Fiber failure determined t be caused by misuse r natural causes (furniture mves, pest damage, fire) will nt be cvered after certificatin ccurs. If required, a separate wrk rder will be pened and price will be negtiated with the Cunty prir t the wrk being perfrmed. 3. Fiber failure determined t be caused by Vendr r ne f its Subcntractrs will be Vendr's respnsibility t repair/replace. 4. Failure f fiber determined t be caused by smething utside f Vendr s cntrl is Cunty s respnsibility t repair/replace. 5. Onging Supprt utlined abve is applicable frm the date f certificatin t the end f the term f the cntract (March 17, 2019). This excludes the extensin f the Term fr up t tw (2) additinal successive perids f nt mre than ne (1) year each. Ats Cunty f Orange MSA fr IT Services Page 27 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

28 6. Ats agrees t pay fr Fiber that is useable but the wrng type (Mde) f fiber fr the slutin. 7. Cunty agrees t pay fr any fiber that is nt useable. This includes the repair and certificatin f the fiber Furniture Mves Out f Scpe fr Vendr - The fllwing are examples f items that are ut f scpe fr furniture mves: 1) Any mve r cnditin that presents a human health hazard, such as standing water, expsed r unsafe pwer lines, the presence f asbests r ther materials that are knwn t cause harm, and the presence f hazardus materials (such as bi-txins, sharps, and medical waste ). 2) Any furniture that requires disassembly, tls, r special equipment. 3) HIPPA cabinets/strage r bjects where special handling is required 4) Furniture weighing mre than 100 punds. 5) Attached fixtures r furniture such as cabinets, desks with earthquake bracing brackets, mdular furniture requiring a technician t disassemble r re-assemble. 6) Fragile items f a highly delicate nature i.e. MDF furniture, labratry equipment 7) Items f high value, such as wrks f art, sculptures, etc.. 8) Precisin equipment that requires an installer t place the equipment r level the equipment. 9) Bkshelves, stacks f bxes, and ther strage cntainers. 10) Furniture r items that are difficult t access r blcked by bstacles, such as pillars, permanent fixtures, r refrigeratrs The fllwing tasks are prvided by Vendr, cnsidered ancillary, inherent r necessary cmpnents f certain Services, including cabling installatins and/r remvals. Mvement f: 1) Furniture under 100 punds that can be easily mved. 2) One-piece desks nt secured t walls r the flr. 3) Small electrnic devices, such as wrkstatins, mnitrs, and wrkgrup printers. 4) Office waste baskets nt cntaining hazardus materials. 5) Small filing cabinets that are nt excessively heavy Vendr Respnsibilities: Vendr will prvide recmmendatins fr furniture mves during each site survey, cabling survey, and pwer walkthrugh (as applicable). Ats Cunty f Orange MSA fr IT Services Page 28 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

29 Vendr will request fr all cabling vendrs t use care when mving furniture at all Cunty Agency facilities and cautin will be taken t nt damage any furniture r ther items at sites. In many cases, furniture mves may nt be necessary when the wrk area can be accessed withut mving the furniture in questin (such as crawling under a desk r wrking arund a printer). Upn cmpletin f wrk in an area, Vendr is instructing cabling vendrs t make best effrt t return the area t the riginal state prir t mving the furniture (excluding the wrk that was being perfrmed, such as remval f a rack r replacement f a faceplate). Cunty/Agency Respnsibilities: The Cunty and Agencies will alert Vendrs f any furniture r items that shuld nt be tuched/mved (sensitive equipment, high-dllar items, HIPAA dcuments) as well as any knwn r pssible hazards r dangers. Prir t knwn plans that may include furniture mves by the Vendr, the Cunty will cmmunicate t Agencies and their users t clear furniture surfaces f persnal effects. Prvide reasnable cnsideratin in granting apprpriate perfrmance relief when Vendr encunters circumstances (described herein as "Out f Scpe" fr furniture mves) that delay Vendr's effrts. Cunty will hire mvers as necessary t cmply with the parameters 5.3 Vice Netwrk Transfrmatin Overview Vice Transfrmatin will ccur in waves as described abut in sectin 3.3. Vendr will deply three instances f the HCS envirnment in the Vendr s Dallas and Pittsburgh data centers. These platfrms will be ge-redundant. Vendr will deply three pair f Cisc Cubes within the OCDC t terminate the SIP Trunking t the Cunty. The Cubes will be cnfigured in a redundant cnfiguratin t supprt the 2,500 cncurrent calls thrughut the cunty. Vendr will perfrm VIP site deplyments in a phased apprach that fllws the data netwrk cnnectivity and netwrk equipment transfrmatin. During each Phase, Vendr will be cnfiguring the Hsted Cisc HCS platfrms t supprt the IP-based vice services. Vendr will als be remtely staging and cnfiguring new vice equipment and prviding nsite installatin and cnfiguratin f new IP-phnes fr all users. Vendr will prvide enhance supprt during pst-site migratin perids (varies by site size perid ranges frm 4 t 48 hurs). SIP trunking will be used t supprt all Inbund/utbund dialing t the Cunty netwrk and lcal circuits. PRIs and 1MBs at remte sites will supprt survivability and E911 functins in the case f a netwrk failure. All class 1, 2 and 3 sites will deply Survivable Remte Site Telephny (SRST). Vendr will exprt data frm the current PBX where technically feasible and prvide this data t the Cunty Site POC. The Cunty Site POC will crdinate with the Site rganizatins t validate the data s accuracy befre site specific cnverged cnfiguratins are created. Vendr will deply a seven-digit dial plan acrss the cunty. Ats Cunty f Orange MSA fr IT Services Page 29 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

30 Dependencies, Assumptins, Cnstraints and Risks Dependencies Delivery f the data netwrk Vendr delivery f Hardware Rles and respnsibilities will be established between Vendr and all third party vendrs Vendr must have an accurate inventry f all supprted systems. Dependent n AT&T t pull PBX data AT&T and Subcntractr DID Prting Dependent n Cunty fr access t all cunty lcatins fr Vendr and Vendr s vendrs Dependent n Cunty fr ff-hurs access t all cunty lcatins fr Vendr s and Vendr vendrs Dependent n Cunty fr all DID assignments during Site Requirements Determinatin Access t existing t PBX infrmatin VIP and Administrative Assistant prgramming In Scpe ancillary Infrmatin e.g. Call Recrding, Call Center, External Paging In Scpe ACD Call Center Assumptins Vendr will be able t rely n lcal Cunty f Orange emplyees t prvide access/crdinatin supprt Vendr persnnel and their sub-cntractrs wh have been prperly vetted and where required have had successful backgrund checks will have access t all the Cunty facilities where they are perfrming wrk Vendr will have access t the PBX s t pull data A 3rd party vendr vetted and apprved by OC IT will be used t prvide hands-n supprt where we can t use lcal Vendr staff Cnstraints The data netwrk must be in place befre mnitring tls can be installed and tested The data netwrk must be able t supprt VIP The lcal Cunty f Orange spaces must be ready frm a facilities perspective Pwer, Space, Cling The data netwrk must be in place fr remte management Risks Mnitring tls will nt be available if the data netwrk is nt established by the required due date Incmplete inventry f in scpe telephne systems Incmplete dcumentatin Hardware nt delivered n time Netwrk nt ready t supprt POE/VIP Cabling/infrastructure nt ready t supprt VIP Issues with AT&T and Subcntractr DID Prting numbers Issues with access t existing PBX data Ats Cunty f Orange MSA fr IT Services Page 30 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

31 5.3.2 Hsted VOIP envirnment Hardware/Hsting envirnment Vendr will prvide a cmbinatin f shared and dedicated cmpnents t deliver the slutin t the Cunty. Vendr will use a Shared Clud Server infrastructure t deliver the cre server cmpnents fr the slutin. The Cunty s PBX applicatins will reside n dedicated blades within the Clud Infrastructure t meet the requirements. Shared Cmpnents Shared Clud Server infrastructure t deliver the cre server cmpnents fr the slutin All ITSM Tls and PBX mnitring tls Dedicated Cmpnents Server Blades that cntain the applicatins fr the PBX Cntact Center Express Premium Servers that supprt the ACD and IVR Emergency Respnder Servers that supprt the E911 Slutin Three separate pairs f Sessin Brder Cntrllers (Cubes) that reside in Califrnia Dedicated Netwrk cnnecting the Dallas and Pittsburgh Data Centers t the Cunty MPLS Netwrk CPE devices such as Phnes, Analg devices, Vice Gateways Vendr will implement gegraphically redundant Call Manager servers in Dallas, TX and Pittsburgh, PA. Vendr will implement a dedicated SIP trunking slutin that is designed with redundant SIP Cubes in tw lcatins in tw separate Cunty facilities within Califrnia. Vendr will implement a Call Prcessing and Vic slutin that can scale t 20,000 users n the Cunty system and 5,000 users n the L&J slutin withut additinal hardware. Vendr will implement a separate redundant Vic slutin that resides in Orange Cunty fr the Public Defender envirnment. Ats Cunty f Orange MSA fr IT Services Page 31 f 37 Exhibit 10 App B7B Transfrmatin Apprach and Methdlgy Plan.dcx

Overview of Data Furnisher Batch Processing

Overview of Data Furnisher Batch Processing Overview f Data Furnisher Batch Prcessing Nvember 2018 Page 1 f 9 Table f Cntents 1. Purpse... 3 2. Overview... 3 3. Batch Interface Implementatin Variatins... 4 4. Batch Interface Implementatin Stages...

More information

HP Server Virtualization Solution Planning & Design

HP Server Virtualization Solution Planning & Design Cnsulting & Integratin Infrastructure Services HP Server Virtualizatin Slutin Planning & Design Service descriptin Hewlett-Packard Cnsulting & Integratin Infrastructure Cnsulting Packaged Services (HP

More information

Wide Area Network (WAN)

Wide Area Network (WAN) Office f Infrmatin Technlgy Services Service Level Agreement Wide Area Netwrk (WAN) January 16, 2014 v2.2 Service Descriptin Wide Area Netwrk (WAN) Service Descriptin The Wide Area Netwrk (WAN) service

More information

Service Description: Advanced Services Fixed Price

Service Description: Advanced Services Fixed Price Page 1 f 6 Service Descriptin: Advanced Services Fixed Price Cisc WLAN Advise and Implement Services Fixed (ASF-CORE-WLAN) This dcument describes Advanced Services Fixed Price: Cisc WLAN Advise and Implement

More information

Aloha Offshore SDLC Process

Aloha Offshore SDLC Process Alha Sftware Develpment Life Cycle Alha Offshre SDLC Prcess Alha Technlgy fllws a sftware develpment methdlgy that is derived frm Micrsft Slutins Framewrk and Ratinal Unified Prcess (RUP). Our prcess methdlgy

More information

McGill University Firewall Sharing Services Service Description and Service Level Agreement. Prepared by Network and Communications Services

McGill University Firewall Sharing Services Service Description and Service Level Agreement. Prepared by Network and Communications Services McGill University Firewall Sharing Services Service Descriptin and Service Level Agreement Prepared by Netwrk and Cmmunicatins Services Revisin Histry Versin Date Summary f changes Apprved by 1.0 February

More information

Statement of Work (SOW) IT activities associated with the Acne Sales Office Relocation Project

Statement of Work (SOW) IT activities associated with the Acne Sales Office Relocation Project SOW fr New Data Center Prject Statement f Wrk (SOW) IT activities assciated with the Acne Sales Office Relcatin Prject Draft as f February 15 th, 2012 Descriptin: Relcate the Acne Sales Office peratin

More information

NCTA-Certified Cloud Technologist (NCT) Exam NCT-110

NCTA-Certified Cloud Technologist (NCT) Exam NCT-110 NCTA-Certified Clud Technlgist (NCT) Exam NCT-110 Exam Infrmatin Candidate Eligibility: The NCTA-Certified Clud Technlgist (NCT) exam requires n applicatin fee, supprting dcumentatin, nr ther eligibility

More information

ERS IT Portfolio Report

ERS IT Portfolio Report Administratin and Operatins Cmmittee ERS IT Prtfli Reprt July 15 th, 2014 1 Agenda Infrmatin Technlgy Prjects Summary Applicatin Stats What s Next IT Prtfli 2 Infrmatin Technlgy Prjects Summary Remte Office

More information

Rapid Implementation Package

Rapid Implementation Package Implementatin Package Implementatin 1 Purpse The purpse f this dcument is t detail thse services BuildingPint NrthEast ( BPNE ) will prvide as part f the Prlg Rapid Implementatin Package. This package

More information

Developing Microsoft SharePoint Server 2013 Core Solutions

Developing Microsoft SharePoint Server 2013 Core Solutions Develping Micrsft SharePint Server 2013 Cre Slutins Develping Micrsft SharePint Server 2013 Cre Slutins Curse Cde: 20488 Certificatin Exam: 70-488 Duratin: 5 Days Certificatin Track: N/A Frmat: Classrm

More information

VMware AirWatch Certificate Authentication for Cisco IPSec VPN

VMware AirWatch Certificate Authentication for Cisco IPSec VPN VMware AirWatch Certificate Authenticatin fr Cisc IPSec VPN Fr VMware AirWatch Have dcumentatin feedback? Submit a Dcumentatin Feedback supprt ticket using the Supprt Wizard n supprt.air-watch.cm. This

More information

ITIL 2011 Service Offerings and Agreements (SOA)

ITIL 2011 Service Offerings and Agreements (SOA) IT SERVICE MANAGEMENT ITIL 2011 Service Offerings and Agreements (SOA) CERTIFICATE: DURATION: COURSE DELIVERY: LANGUAGE: ITIL 2011 Service Offerings and Agreements (SOA) 5 Days Classrm, Live Virtual Classrm

More information

Update: Users are updated when their information changes (examples: Job Title or Department). o

Update: Users are updated when their information changes (examples: Job Title or Department). o Learn Basic User Integratin Batch File Prcessing The Learn Basic User Integratin is designed t manage the rganizatinal changes cmpanies are challenged with n a daily basis. Withut a basic type f integratin,

More information

Licensing the Core Client Access License (CAL) Suite and Enterprise CAL Suite

Licensing the Core Client Access License (CAL) Suite and Enterprise CAL Suite Vlume Licensing brief Licensing the Cre Client Access License (CAL) Suite and Enterprise CAL Suite Table f Cntents This brief applies t all Micrsft Vlume Licensing prgrams. Summary... 1 What s New in this

More information

CAMPBELL COUNTY GILLETTE, WYOMING

CAMPBELL COUNTY GILLETTE, WYOMING CAMPBELL COUNTY GILLETTE, WYOMING System Supprt Analyst I System Supprt Analyst II Senir System Supprt Analyst Class specificatins are intended t present a descriptive list f the range f duties perfrmed

More information

Service Level Agreement

Service Level Agreement Service Level Agreement Infrastructure Supprt Service This Infrastructure Supprt Service Level Agreement ( SLA ) is incrprated int the Qute executed by TekLinks and Custmer fr Infrastructure Supprt Services

More information

INFORMATION TECHNOLOGY SERVICES NIST COMPLIANCE AT FSU - CONTROLLED UNCLASSIFIED INFORMATION

INFORMATION TECHNOLOGY SERVICES NIST COMPLIANCE AT FSU - CONTROLLED UNCLASSIFIED INFORMATION NIST 800-171 COMPLIANCE AT FSU - CONTROLLED UNCLASSIFIED INFORMATION WHAT IS NIST 800-171 COMPLIANCE AND WHY DO WE HAVE TO DO IT? Any Cntrlled Unclassified Infrmatin (CUI) residing in nnfederal infrmatin

More information

Service Level Agreement

Service Level Agreement Service Level Agreement Infrastructure Supprt Service This Infrastructure Supprt Service Level Agreement ( SLA ) is incrprated int the Qute executed by TekLinks and Custmer fr Infrastructure Supprt Services

More information

CCNA Voice ICOMM: (4 Day Course)

CCNA Voice ICOMM: (4 Day Course) CCNA Vice 640-461 ICOMM: (4 Day Curse) The CCNA Vice certificatin cnfirms that yu have the required skill set fr specialised jb rles in vice technlgies such as vice technlgies administratr, vice engineer,

More information

Point-to-Point Encryption (P2PE)

Point-to-Point Encryption (P2PE) Payment Card Industry (PCI) Pint-t-Pint Encryptin (P2PE) Template fr P2PE Applicatin Reprt n Validatin (Applicatin P-ROV) Applicatin P-ROV Template Fr Applicatins used with PCI P2PE Hardware/Hardware Standard

More information

Patch Management Policy

Patch Management Policy Patch Management Plicy (Versin 1) Dcument Cntrl Infrmatin: Date: 21/5/18 Master Tracking Name Patch Management Plicy Master Tracking Reference Owning Service / Department Exeter IT Issue: 1 Apprvals: Authrs:

More information

BMC Remedyforce Integration with Remote Support

BMC Remedyforce Integration with Remote Support BMC Remedyfrce Integratin with Remte Supprt 2003-2018 BeyndTrust, Inc. All Rights Reserved. BEYONDTRUST, its lg, and JUMP are trademarks f BeyndTrust, Inc. Other trademarks are the prperty f their respective

More information

Service Description: Cisco Preemptive Service

Service Description: Cisco Preemptive Service Page 1 f 6 Service Descriptin: Cisc Preemptive Service This dcument describes the Cisc Preemptive Service fr fllwing technlgies: - Brderless/NGN - Cllabratin - DC clud and VXI - SP Vide - Mbility Related

More information

Admin Report Kit for Exchange Server

Admin Report Kit for Exchange Server Admin Reprt Kit fr Exchange Server Reprting tl fr Micrsft Exchange Server Prduct Overview Admin Reprt Kit fr Exchange Server (ARKES) is an Exchange Server Management and Reprting slutin that addresses

More information

Quick Setup Guide. Aastra MX-ONE V.4.0 Integration with Microsoft OCS 2007 R2. Doc. Nr. ASE/MXO/PLM/ 0123/EN Rev.A

Quick Setup Guide. Aastra MX-ONE V.4.0 Integration with Microsoft OCS 2007 R2. Doc. Nr. ASE/MXO/PLM/ 0123/EN Rev.A Aastra MX-ONE V.4.0 Integratin with Micrsft OCS 2007 R2 Quick Setup Guide Aastra Telecm Sweden AB SE-126 37 Hägersten, Sweden Dc. Nr. ASE/MXO/PLM/ 0123/EN Rev.A www.aastra.cm Cntents 1 Intrductin 3 1.1

More information

Software Usage Policy Template

Software Usage Policy Template Sftware Usage Plicy Template This template is t accmpany the article: The Sftware Usage Plicy - An Indispensible Part f Yu SAM Tlbx The full article can be fund here: http://www.itassetmanagement.net/tag/plicy-template/

More information

CA CMDB Connector for z/os

CA CMDB Connector for z/os PRODUCT SHEET: CA CMDB CONNECTOR FOR Z/OS CA CMDB Cnnectr fr z/os CA CMDB Cnnectr fr z/os discvers mainframe cnfiguratin items (CIs) and enables ppulatin f that infrmatin int the CA CMDB repsitry. Designed

More information

CLIENT. Corporation. Hosting Services. August 24, Marc Gray Flywire Technology CLIENT. 104 West Candler St Winder, GA

CLIENT. Corporation. Hosting Services. August 24, Marc Gray Flywire Technology CLIENT. 104 West Candler St Winder, GA CLIENT Crpratin Hsting Services August 24, 2011 PRESENTED TO: PRESENTED BY: Marc Gray Flywire Technlgy CLIENT 104 West Candler St Winder, GA 30680 770-771-5299 Marc@ flywiretechnlgy.cm TABLE OF CONTENTS

More information

E-Lock Policy Manager White Paper

E-Lock Policy Manager White Paper White Paper Table f Cntents 1 INTRODUCTION... 3 2 ABOUT THE POLICY MANAGER... 3 3 HOW E-LOCK POLICY MANAGER WORKS... 3 4 WHAT CAN I DO WITH THE POLICY MANAGER?... 4 4.1 THINGS YOU CONTROL IN SIGNING...

More information

InForm On Demand Enterprise Services Description

InForm On Demand Enterprise Services Description InFrm On Demand Enterprise Services Descriptin Versin 7.5 Effective Date: 14-December-2017 This is the InFrm On Demand Enterprise Services Descriptin ( Schedule ) t Yur Study Order fr Oracle InFrm On Demand

More information

Request for Proposals (RFP) Bid Reference RFP 2016/DAF/ICT/001 UN CITY ICT BASIC SUPPORT AND OUTSOURCING SERVICES. Annex 1: Terms of Reference

Request for Proposals (RFP) Bid Reference RFP 2016/DAF/ICT/001 UN CITY ICT BASIC SUPPORT AND OUTSOURCING SERVICES. Annex 1: Terms of Reference Request fr Prpsals (RFP) Bid Reference RFP 2016/DAF/ICT/001 UN CITY ICT BASIC SUPPORT AND OUTSOURCING SERVICES Annex 1: Terms f Reference 1 UN CITY ICT BASIC SUPPORT AND OUTSOURCING SERVICES Annex 1 Terms

More information

BMC Remedyforce Integration with Bomgar Remote Support

BMC Remedyforce Integration with Bomgar Remote Support BMC Remedyfrce Integratin with Bmgar Remte Supprt 2017 Bmgar Crpratin. All rights reserved wrldwide. BOMGAR and the BOMGAR lg are trademarks f Bmgar Crpratin; ther trademarks shwn are the prperty f their

More information

Introduction to Mindjet on-premise

Introduction to Mindjet on-premise Intrductin t Mindjet n-premise Mindjet Crpratin Tll Free: 877-Mindjet 1160 Battery Street East San Francisc CA 94111 USA Phne: 415-229-4200 Fax: 415-229-4201 www.mindjet.cm 2012 Mindjet. All Rights Reserved

More information

CNS-222-1I: NetScaler for Apps and Desktops

CNS-222-1I: NetScaler for Apps and Desktops CNS-222-1I: NetScaler fr Apps and Desktps Overview Designed fr students with little r n previus NetScaler, NetScaler Gateway r Unified Gateway experience, this curse is best suited fr individuals wh will

More information

InForm On Demand Single Trial Services Description

InForm On Demand Single Trial Services Description InFrm On Demand Single Trial Services Descriptin Versin 7.5 Effective Date: 14-December-2017 This is the Services Descriptin fr Oracle InFrm On Demand Single Trial ( Schedule ) t Yur Study Order fr Oracle

More information

Date: October User guide. Integration through ONVIF driver. Partner Self-test. Prepared By: Devices & Integrations Team, Milestone Systems

Date: October User guide. Integration through ONVIF driver. Partner Self-test. Prepared By: Devices & Integrations Team, Milestone Systems Date: Octber 2018 User guide Integratin thrugh ONVIF driver. Prepared By: Devices & Integratins Team, Milestne Systems 2 Welcme t the User Guide fr Online Test Tl The aim f this dcument is t prvide guidance

More information

Milestone Solution Partner IT Infrastructure Components Certification Summary

Milestone Solution Partner IT Infrastructure Components Certification Summary Milestne Slutin Partner IT Infrastructure Cmpnents Certificatin Summary Prmise Technlgies VESS R2600 Strage Slutin 08-27-2014 Table f Cntents Intrductin... 3 Certified Prducts... 3 Test Prcess... 3 Tplgy...

More information

App Orchestration 2.6

App Orchestration 2.6 App Orchestratin 2.6 Terminlgy in App Orchestratin 2.6 Last Updated: July 8, 2015 Page 1 Terminlgy Cntents Elements f App Orchestratin... 3 Dmains... 3 Multi-Datacenter Deplyments... 4 Delivery Sites...

More information

BME Smart-Colo. Smart-Colo is a solution optimized for the colocation of trading applications, built and managed by BME.

BME Smart-Colo. Smart-Colo is a solution optimized for the colocation of trading applications, built and managed by BME. BME Smart-Cl 1. Intrductin The aim f this dcument is t describe the BME Smart-Cl service fr accessing BME Cash, BME Derivative markets and market data feeds. Smart-Cl service prvides at the BME Data Center

More information

CCNA 1 Chapter 1 v5.03 Exam Answers 2016

CCNA 1 Chapter 1 v5.03 Exam Answers 2016 CCNA 1 Chapter 1 v5.03 Exam Answers 2016 1. A cmpany is cntemplating whether t use a client/server r a peer-t-peer netwrk. What are three characteristics f a peer-t-peer netwrk? (Chse three.) better security

More information

Child Care Services Association Request for Proposal Durham PreK Website

Child Care Services Association Request for Proposal Durham PreK Website Child Care Services Assciatin Request fr Prpsal Durham PreK Website Prject Summary Child Care Services Assciatin (CCSA) (Agency) is seeking prpsals frm a firm r individual designer/develper (Vendr) t develp

More information

TPP: Date: October, 2012 Product: ShoreTel PathSolutions System version: ShoreTel 13.x

TPP: Date: October, 2012 Product: ShoreTel PathSolutions System version: ShoreTel 13.x I n n v a t i n N e t w r k A p p N t e TPP: 10320 Date: Octber, 2012 Prduct: ShreTel PathSlutins System versin: ShreTel 13.x Abstract PathSlutins sftware can find the rt-cause f vice quality prblems in

More information

UPGRADING TO DISCOVERY 2005

UPGRADING TO DISCOVERY 2005 Centennial Discvery 2005 Why Shuld I Upgrade? Discvery 2005 is the culminatin f ver 18 mnths wrth f research and develpment and represents a substantial leap frward in audit and decisin-supprt technlgy.

More information

IHIS Research Access Request Guidelines

IHIS Research Access Request Guidelines Eservices: https://sumc.service-nw.cm/ 1. FOR NEWLY HIRED EMPLOYEES: Use On-barding Services & On-Barding Guide Frm Please Nte the fields required fr Research IHIS access are the same as thse utlined in

More information

CCNA 1 Chapter v5.1 Answers 100%

CCNA 1 Chapter v5.1 Answers 100% CCNA 1 Chapter 11 2016 v5.1 Answers 100% 1. A newly hired netwrk technician is given the task f rdering new hardware fr a small business with a large grwth frecast. Which primary factr shuld the technician

More information

HPE LoadRunner Best Practices Series. LoadRunner Upgrade Best Practices

HPE LoadRunner Best Practices Series. LoadRunner Upgrade Best Practices HPE LadRunner Best Practices Series LadRunner 12.50 Upgrade Best Practices Dcument publicatin date: Nvember 2015 Cntents 1. Intrductin... 3 Overview... 3 Audience... 3 2. Preparatin... 3 Backup assets...

More information

CLOUD & DATACENTER MONITORING WITH SYSTEM CENTER OPERATIONS MANAGER. Course 10964B; Duration: 5 Days; Instructor-led

CLOUD & DATACENTER MONITORING WITH SYSTEM CENTER OPERATIONS MANAGER. Course 10964B; Duration: 5 Days; Instructor-led CENTER OF KNOWLEDGE, PATH TO SUCCESS Website: www.inf-trek.cm CLOUD & DATACENTER MONITORING WITH SYSTEM CENTER OPERATIONS MANAGER Curse 10964B; Duratin: 5 Days; Instructr-led WHAT YOU WILL LEARN This curse

More information

Implementing a Data Warehouse with Microsoft SQL Server

Implementing a Data Warehouse with Microsoft SQL Server Implementing a Data Warehuse with Micrsft SQL Server Implementing a Data Warehuse with Micrsft SQL Server Curse Cde: 20463 Certificatin Exam: 70-463 Duratin: 5 Days Certificatin Track: MCSA: SQL Server

More information

NSE 8 Certification. Exam Description for FortiGate 5.2 and higher

NSE 8 Certification. Exam Description for FortiGate 5.2 and higher NSE 8 Certificatin Exam Descriptin fr FrtiGate 5.2 and higher NSE 8 Certificatin Exam Descriptin fr FrtiGate 5.2 and higher Last Updated: 12 June 2017 Frtinet, FrtiGate, and FrtiGuard are registered trademarks

More information

DELL EMC PERSONALIZED SUPPORT SERVICES

DELL EMC PERSONALIZED SUPPORT SERVICES DELL EMC PERSONALIZED SUPPORT SERVICES Optimize yur Dell EMC investment based n yur unique requirements ESSENTIALS Dell EMC Persnalized Supprt Services: Custmize and enhance yur Dell EMC Custmer Service

More information

Customer Upgrade Checklist

Customer Upgrade Checklist Custmer Upgrade Checklist Getting Ready fr Yur Sabre Prfiles Upgrade Kicking Off the Prject Create a prfiles prject team within yur agency. Cnsider including peple wh can represent bth the business and

More information

E. G. S. Pillay Engineering College, Nagapattinam Computer Science and Engineering

E. G. S. Pillay Engineering College, Nagapattinam Computer Science and Engineering IT2042 - Infrmatin Security 1-1 E. G. S. Pillay Engineering Cllege, Nagapattinam Cmputer Science and Engineering Elective II IT 2042 INFORMATION SECURITY VIII Sem CSE QUESTION BANK - UNIT-IV 1) What is

More information

SafeDispatch SDR Gateway for MOTOROLA TETRA

SafeDispatch SDR Gateway for MOTOROLA TETRA SafeDispatch SDR Gateway fr MOTOROLA TETRA SafeMbile ffers a wrld f wireless applicatins that help rganizatins better manage their mbile assets, fleet and persnnel. Fr mre infrmatin, see www.safembile.cm.

More information

Cisco EPN Manager Network Administration

Cisco EPN Manager Network Administration Training Data Sheet Cisc EPN Manager Netwrk Administratin Cisc EPN Manager Netwrk Administratin is an instructr-led and lab-based curse in which yu learn t mnitr, cnfigure, and prvisin netwrk devices by

More information

UNSW Technology Policy:

UNSW Technology Policy: UNSW Technlgy Plicy: UNSW Plicy Respnsible Officer Cntact Officer Apprving Authrity UNSW Data Netwrk Cnnectin Plicy Chief Infrmatin Officer Manager Infrastructure Services Supprt UNSW IT Services Ph: x

More information

Utilities Global Business* Service Descriptions and Metrics

Utilities Global Business* Service Descriptions and Metrics Utilities Glbal Business* Service Descriptins and Metrics January 30, 2017 *Nte: The Service Descriptins fr Oracle Dataraker Clud Services can be fund in a separate dcument at www.racle.cm/cntracts. Oracle

More information

Overview. Recommended pre-requisite courses: Key Skills. : CNS-220-1I: Citrix NetScaler Traffic Management

Overview. Recommended pre-requisite courses: Key Skills. : CNS-220-1I: Citrix NetScaler Traffic Management Mdule Title Duratin : CNS-220-1I: Citrix NetScaler Traffic Management : 5 days Overview Designed fr students with little r n previus NetScaler experience, this curse is best suited fr individuals wh will

More information

IMPORTING INFOSPHERE DATA ARCHITECT MODELS INFORMATION SERVER V8.7

IMPORTING INFOSPHERE DATA ARCHITECT MODELS INFORMATION SERVER V8.7 IMPORTING INFOSPHERE DATA ARCHITECT MODELS INFORMATION SERVER V8.7 Prepared by: March Haber, march@il.ibm.cm Last Updated: January, 2012 IBM MetaData Wrkbench Enablement Series Table f Cntents: Table f

More information

CNS-220-1I: Citrix NetScaler Essentials and Traffic Management

CNS-220-1I: Citrix NetScaler Essentials and Traffic Management CNS-220-1I: Citrix NetScaler Essentials and Traffic Management Overview Designed fr students with little r n previus NetScaler experience, this curse is best suited fr individuals wh will be deplying r

More information

Oracle Health Sciences. InForm Trial Capacity Cloud Service Service Descriptions and Metrics

Oracle Health Sciences. InForm Trial Capacity Cloud Service Service Descriptions and Metrics Oracle Health Sciences InFrm Trial Capacity Clud Service Service Descriptins and Metrics June 29, 2018 Table f Cntents Metric Definitins... 2 Custmer... 2 Glssary... 2 Trial... 2 InFrm Trial Capacity Services

More information

55114: Planning, Deploying and Managing Microsoft Project Server 2010 Duration: 3 Days Method: Instructor-Led

55114: Planning, Deploying and Managing Microsoft Project Server 2010 Duration: 3 Days Method: Instructor-Led 55114: Planning, Deplying and Managing Micrsft Prject Server 2010 Duratin: 3 Days Methd: Instructr-Led Curse Descriptin The gal f this three-day instructr-led curse is t prvide students with the knwledge

More information

Cyber Security Supply Chain Risk Management Plans

Cyber Security Supply Chain Risk Management Plans ERO Enterprise-Endrsed Implementatin Guidance. Endrsement fr this implementatin guidance is based n the language f draft 2 f the CIP-013-1 Reliability Standard dated April 2017. Any changes t the standard

More information

Cisco EPN Manager Operations

Cisco EPN Manager Operations Training Data Sheet Cisc EPN Manager Operatins Cisc EPN Manager Operatins is an instructr-led and lab-based curse in which yu learn t perfrm basic EPN Manager netwrk peratins functins. The Cisc Evlved

More information

ITD Information Security October 19, 2015

ITD Information Security October 19, 2015 ITD Infrmatin Security Octber 19, 2015 Cntents Intrductin... 3 Synpsis... 3 ITD Security Team... 3 Cunty Emplyees... 3 Malware Prtectin... 4 Physical Security... 4 Data... 4 Internet... 4 Micrsft Office

More information

Performance and Scalability Benchmark: Siebel CRM Release 7.7 Industry Applications on HP Integrity Server and Microsoft SQL Server 2005

Performance and Scalability Benchmark: Siebel CRM Release 7.7 Industry Applications on HP Integrity Server and Microsoft SQL Server 2005 Perfrmance and Scalability Benchmark: Siebel CRM Release 7.7 Industry Applicatins n HP Integrity Server and Micrsft SQL Server 2005 An Oracle White Paper Released Octber 2005 Perfrmance and Scalability

More information

Performance and Scalability Benchmark: Siebel CRM Release 7.7 Industry Applications on HP ProLiant Server and Microsoft SQL Server 2005

Performance and Scalability Benchmark: Siebel CRM Release 7.7 Industry Applications on HP ProLiant Server and Microsoft SQL Server 2005 Perfrmance and Scalability Benchmark: Siebel CRM Release 7.7 Industry Applicatins n HP PrLiant Server and Micrsft SQL Server 2005 An Oracle White Paper Released Octber 2005 Perfrmance and Scalability Benchmark:

More information

The Customer Journey to SD-WAN Functional, Technical, and Economic Considerations Part 2: SD-WAN: Is It Right for Your Network?

The Customer Journey to SD-WAN Functional, Technical, and Economic Considerations Part 2: SD-WAN: Is It Right for Your Network? The Custmer Jurney t SD-WAN Functinal, Technical, and Ecnmic Cnsideratins Part 2: SD-WAN: Is It Right fr Yur Netwrk? Technlgy Jel Stradling, Research Directr jel.stradling@glbaldata.cm Spnsred by Published:

More information

Request for Proposal Technology Services Maintenance and Support

Request for Proposal Technology Services Maintenance and Support Request fr Prpsal Technlgy Services Maintenance and Supprt Maintenance and Supprt July 19, 2014 Celerity Tenacia Charter Schl is seeking an IT cnsulting firm t manage Maintenance f ur Netwrk Systems beginning

More information

Additional License Authorizations

Additional License Authorizations Additinal License Authrizatins Fr HPE CMS SIM Management sftware prducts Prducts and suites cvered PRODUCTS E-LTU OR E-MEDIA AVAILABLE * NON-PRODUCTION USE OPTION HPE Dynamic SIM Prvisining Yes Yes HPE

More information

Basic Technology Fee. Page 1

Basic Technology Fee. Page 1 Basic Technlgy Fee Cntents Basic Tech Fee Overview... 1 BTF Calculatin... 1 BTF Distributin... 1 Basic BTF Cverage... 1 Services Outside BTF Cverage/Additinal Charges... 1 Specifics Items Cvered by the

More information

Disaster Recovery. Practical Applications. Eric LaFollette. Director of Information Resources Lake County Clerk of Courts

Disaster Recovery. Practical Applications. Eric LaFollette. Director of Information Resources Lake County Clerk of Courts Disaster Recvery Practical Applicatins Eric LaFllette Directr f Infrmatin Resurces Lake Cunty Clerk f Curts Presentatin Outline Imprtance f a plan Disaster Recvery Scenaris Disaster Recvery Basics Lake

More information

DELL EMC VxRAIL vcenter SERVER PLANNING GUIDE

DELL EMC VxRAIL vcenter SERVER PLANNING GUIDE WHITE PAPER - DELL EMC VxRAIL vcenter SERVER PLANNING GUIDE ABSTRACT This planning guide discusses guidance fr the varius vcenter Server deplyment ptins supprted n VxRail Appliances. Nvember 2017 TABLE

More information

Dynamic Storage (ECS)

Dynamic Storage (ECS) User Guide Dynamic Strage (ECS) Swisscm (Schweiz) AG 1 / 10 Cntent 1 Abut Dynamic Strage... 3 2 Virtual drive, the EMC CIFS-ECS Tl... 4 3 Amazn S3 Brwer... 6 4 Strage Gateway Appliance... 9 5 Amazn S3

More information

Service Description Safecom Secure Mail Relay Version 3.5

Service Description Safecom Secure Mail Relay Version 3.5 Service Descriptin Safecm Secure Mail Relay Versin 3.5 2006 Telecm NZ Ltd Cmmercial in Cnfidence CONTENTS 1 INTRODUCTION... 3 2 SERVICE DEFINITION... 3 2.1 SERVICE OVERVIEW... 3 2.2 SERVICE FEATURES...

More information

(CNS-220) Citrix NetScaler Essentials and Traffic Management

(CNS-220) Citrix NetScaler Essentials and Traffic Management (CNS-220) Citrix NetScaler Essentials and Traffic Management Overview Designed fr students with little r n previus NetScaler experience, this curse is best suited fr individuals wh will be deplying r managing

More information

OpenScape Business V2

OpenScape Business V2 OpenScape Business V2 Tutrial VIP Interfaces Versin 2.0 Definitins HwT An OpenScape Business HwT describes the cnfiguratin f an OpenScape Business feature within the OpenScape Business administratin. It

More information

General Service Responsibilities

General Service Responsibilities Page 1 f 1 Service Descriptin: Cisc Security Optimizatin Service This dcument describes Cisc Security Optimizatin Service. Related Dcuments: This dcument shuld be read in cnjunctin with the fllwing dcuments

More information

Extended Traceability Report for Enterprise Architect

Extended Traceability Report for Enterprise Architect Extended Traceability Reprt User Guide Extended Traceability Reprt fr Enterprise Architect Extended Traceability Reprt fr Enterprise Architect... 1 Disclaimer... 2 Dependencies... 2 Overview... 2 Limitatins

More information

CCNA course contents:

CCNA course contents: CCNA curse cntents: Prerequisites: The knwledge and skills that yu must have befre attending this curse are as fllws: Basic cmputer literacy Windws navigatin skills Basic Internet usage skills Fundamental

More information

BlackBerry Server Installation and Upgrade Service

BlackBerry Server Installation and Upgrade Service Server and Upgrade Service Prgram Descriptin ( Install and Upgrade Service Prgram Descriptin ) NOTE: This dcument includes all attached Annexes, is prvided fr infrmatinal purpses nly, and des nt cnstitute

More information

Your New Service Request Process: Technical Support Reference Guide for Cisco Customer Journey Platform

Your New Service Request Process: Technical Support Reference Guide for Cisco Customer Journey Platform Supprt Guide Yur New Service Request Prcess: Technical Supprt Reference Guide fr Cisc Custmer Jurney Platfrm September 2018 2018 Cisc and/r its affiliates. All rights reserved. This dcument is Cisc Public

More information

Info Tech Update Contract Management Conference March 29, 2017

Info Tech Update Contract Management Conference March 29, 2017 Inf Tech Update Cntract Management Cnference March 29, 2017 Ward Zerbe, Accunt Manager Inf Tech, Inc. 2015 Inf Tech, Inc Crprate prfile In business since 1977 Develp, maintain, implement and supprt cnstructin

More information

Parallels Operations Automation 5.3

Parallels Operations Automation 5.3 Prduct Update Parallels Operatins Autmatin 5.3 What s New Learn mre at http://www.parallels.cm/spp Nvember 2011 Table f Cntents Intrductin... 1 Tp New Features... 1 Tp Imprvements... 2 SaaS Imprvements...

More information

Oracle Health Sciences. InForm Direct Cloud Service Service Descriptions and Metrics

Oracle Health Sciences. InForm Direct Cloud Service Service Descriptions and Metrics Oracle Health Sciences InFrm Clud Service Service Descriptins and Metrics December 14, 2017 Table f Cntents Metric Definitins... 2 Patient... 2 Site... 2 Trial... 2 Service Descriptins fr Clud Services...

More information

Cisco EPN Manager Network Administration - Optical

Cisco EPN Manager Network Administration - Optical Training Data Sheet Cisc EPN Manager Netwrk Administratin - Optical Cisc EPN Manager Netwrk Administratin - Optical is an instructr-led and labbased curse in which yu learn t mnitr, cnfigure, and prvisin

More information

Networks: Communicating and Sharing Resources. Chapter 7: Networks: Communicating and Sharing Resources

Networks: Communicating and Sharing Resources. Chapter 7: Networks: Communicating and Sharing Resources Netwrks: Cmmunicating and Sharing Resurces Chapter 7: Netwrks: Cmmunicating and Sharing Resurces 1 Netwrks: Cmmunicating and Sharing Resurces 2 Objectives Understand basic netwrking cncepts. Distinguish

More information

How to Guide. DocAve Extender for MOSS 2007 and SPS Installing DocAve Extender and Configuring a Basic SharePoint to Cloud Extension

How to Guide. DocAve Extender for MOSS 2007 and SPS Installing DocAve Extender and Configuring a Basic SharePoint to Cloud Extension Hw t Guide DcAve Extender fr MOSS 2007 and SPS 2010 Installing DcAve Extender and Cnfiguring a Basic SharePint t Clud Extensin This dcument is intended fr anyne wishing t familiarize themselves with the

More information

Group Policy Manager Quick start Guide

Group Policy Manager Quick start Guide Grup Plicy Manager Quick start Guide Sftware versin 4.0.0.0 General Infrmatin: inf@cinsystems.cm Online Supprt: supprt@cinsystems.cm Cpyright CinSystems Inc., All Rights Reserved Page 1 CinSystems Inc.

More information

OATS Registration and User Entitlement Guide

OATS Registration and User Entitlement Guide OATS Registratin and User Entitlement Guide The OATS Registratin and Entitlement Guide prvides the fllwing infrmatin: OATS Registratin The prcess and dcumentatin required fr a firm r Service Prvider t

More information

Contingency Planning Template

Contingency Planning Template Cntingency Planning Template Prject Name: U.S. Department f Husing and Urban Develpment Octber, 2010 Cntigency Planning Template (V1.0) Ntes t the Authr [This dcument is a template f a Security Apprach

More information

Customer Information. Agilent 2100 Bioanalyzer System Startup Service G2949CA - Checklist

Customer Information. Agilent 2100 Bioanalyzer System Startup Service G2949CA - Checklist This checklist is used t prvide guidance and clarificatin n aspects f the auxillary Startup Service (G2949CA) including Security Pack Installatin and Familiarizatin f yur Agilent 2100 Bianalyzer System

More information

*LTE Speeds vary for reasons like location, distance from base stations, terrain, user numbers,

*LTE Speeds vary for reasons like location, distance from base stations, terrain, user numbers, FAQ: SmartBradband Wireless Uncapped All Hurs & Business Hurs 1. What is SmartBradband Wireless All Hurs & Business Hurs? The SmartBradband Wireless All Hurs & Business Hurs service is a wireless bradband

More information

CSC IT practix Recommendations

CSC IT practix Recommendations CSC IT practix Recmmendatins CSC Healthcare 17 th June 2015 Versin 3.1 www.csc.cm/glbalhealthcare Cntents 1 Imprtant infrmatin 3 2 IT Specificatins 4 2.1 Wrkstatins... 4 2.2 Minimum Server with 1-5 wrkstatins

More information

Performance of usage of MindSphere depends on the bandwidth of your internet connection.

Performance of usage of MindSphere depends on the bandwidth of your internet connection. MindSphere MindAccess User Data Sheet MindAccess User prvides yu with an Accunt in rder t access the MindSphere Platfrm. This allws yu t cnfigure Assets and Users, access Applicatins and stre data. Such

More information

Max 8/16 and T1/E1 Gateway, Version FAQs

Max 8/16 and T1/E1 Gateway, Version FAQs Frequently Asked Questins Max 8/16 and T1/E1 Gateway, Versin 1.5.10 FAQs The FAQs have been categrized int the fllwing tpics: Calling Calling Cmpatibility Cnfiguratin Faxing Functinality Glssary Q. When

More information

IT Essentials (ITE v6.0) Chapter 8 Exam Answers 100% 2016

IT Essentials (ITE v6.0) Chapter 8 Exam Answers 100% 2016 IT Essentials (ITE v6.0) Chapter 8 Exam Answers 100% 2016 1. A user ntices that the data transfer rate fr the gigabit NIC in the user cmputer is much slwer than expected. What is a pssible cause fr the

More information

Service Description: Cisco Optimization Service for Network Function Virtualization and Virtual Managed Services

Service Description: Cisco Optimization Service for Network Function Virtualization and Virtual Managed Services Page 1 f 1 Service Descriptin: Cisc Optimizatin Service fr Netwrk Functin Virtualizatin and Virtual Managed Services This dcument describes Cisc Optimizatin Service fr Netwrk Functin Virtualizatin (NFV).

More information

TPCH Data Sharing Policies and Procedures

TPCH Data Sharing Policies and Procedures TPCH Data Sharing Plicies and Prcedures Intrductin: The TPCH Data Sharing Plicies and Prcedures were created based n the CC apprved Pima Cunty: HMIS Data Sharing Plan apprved by TPCH bard n February 24,

More information

CaseWare Working Papers. Data Store user guide

CaseWare Working Papers. Data Store user guide CaseWare Wrking Papers Data Stre user guide Index 1. What is a Data Stre?... 3 1.1. When using a Data Stre, the fllwing features are available:... 3 1.1.1.1. Integratin with Windws Active Directry... 3

More information