Please refer to the above Request for Proposal (RFP) document in your possession and be advised of the following:
|
|
- Marlene King
- 5 years ago
- Views:
Transcription
1 Lou Pagano Director Purchasing and Materials Management Division City Hall, 18 th Floor, West Tower 100 Queen Street West Toronto, Ontario M5H 2N2 Victor Tryl, Manager Professional Services November 23, 2011 posted in pdf (15 pages) ADDENDUM NO. 2 Request for Proposal No FOR: Professional Engineering Services associated with the PLC Platform Migration & Upgrades in Water Treatment & Supply facilities. CLOSING: 12:00 NOON (LOCAL TIME), December 12, (Revised) Please refer to the above Request for Proposal (RFP) document in your possession and be advised of the following: I. CHANGE A2-1 Closing has been extended from November 28, 2011until 12:00 Noon (Local Time), December 12, 2011 II. QUESTIONS & RESPONSES A2-2 Question 1 How many SCADA servers and how many iclients are installed and must be updated? Response There are 40 Servers and approximately 50 iclients. SCADA Architecture drawings for all facilities are attached for reference. A2-3 Question 2 Section item b (ii) refers to 'micro PLC's'. What are these, and how many micro PLC's are part of this project? Response Please see attached spreadsheet for descriptions and device quantities. A2-4 Question 3 Appendix E includes the new PLC's part of the Milliken PS and Reservoir expansion, but new PLC's for the Dufferin Reservoir expansion are missing? Response A layout sketch of the PLC's installed under the Dufferin Reservior expansion has been attached for reference. 1 of 15
2 Note: Another addendum will be issued in the next few days to answer the balance of the questions asked up to the closing date of questions which was November 22, Should you have any questions regarding this addendum contact Kay Humphrey at or by Please attach this addendum to your RFP document and be governed accordingly. Proponents must acknowledge receipt of all addenda in their Proposal in the space provided on the Proposal Submission Form as per Appendix B, Section 4 - Addenda of the RFP document. All other aspects of the RFP remain the same. Victor Tryl, P. Eng. Manager Professional Services 2 of 15
3 FACILITIES SCADA ARCHITECTURE DRAWINGS 3 of 15
4 R.L. CLARK (FCL) SCADA ARCHITECTURE DRAWING 4 of 15
5 5 of 15
6 F.C. HARRIS (FHA) SCADA ARCHITECTURE DRAWING 6 of 15
7 7 of 15
8 F.J. HORGAN (FHO) SCADA ARCHITECTURE DRAWING 8 of 15
9 9 of 15
10 ISLAND WTP (FIS) SCADA ARCHITECTURE DRAWING 10 of 15
11 11 of 15
12 WATER SUPPLY (WTR) SCADA ARCHITECTURE DRAWING 12 of 15
13 Water LOU DI GIRONIMO GENERAL MANAGER, TORONTO WATER TORONTO WATER OPERATIONAL SUPPORT ALEX MARICH DIRECTOR, OPERATIONAL SUPPORT WATER SUPPLY SCADA NETWORK ARCHITECTURE NETWORK ARCHITECTURE WATER SUPPLY 0 OCT 2011 UPDATED AS IT IS No. DATE REVISIONS INITIAL SIGNED JIM HARNUM DIRECTOR, WATER TREATMENT AND SUPPLY DESIGN: SCALE: DATE: DRAFTING: N.T.S. CHECK: DRAWING NUMBER: 13 of 15
14 DUFFERIN RESERVOIR WTR-RDF-RPU-0001 / RPU-0002 CURRENT RPU MODULE LAYOUT (RPU-0001) Rack 0 IC693CHS391 SLOT 01 SLOT 02 SLOT 03 SLOT 04 SLOT 05 SLOT 06 SLOT 07 SLOT 08 SLOT 09 SLOT 10 POWER SUPPLY IC693PWR330 CPU IC693CPU364 COMM ITERFACE IC693CMM311 DO MODULE IC693MDL940 AI MODULE IC693ALG223 EXPANSION RX3I RPU MODULE LAYOUT Rack 0 IC695CHS012 SLOT 00 SLOT 01 SLOT 02 SLOT 03 SLOT 04 SLOT 05 SLOT 06 SLOT 07 SLOT 08 SLOT 09 SLOT 10 SLOT 11 POWER SUPPLY IC695PSA040 CPU IC695CPE305 DO MODULE IC693MDL940 AI MODULE IC693ALG223 EXPANSION Notes: 1. Communication interface module with OIT (IC693CMM311) to be removed. Use serial port on the new CPU for the communication with OIT. Connect and make program changes accordingly. CURRENT RPU MODULE LAYOUT (RPU-0002) Rack 0 IC693CHS391 SLOT 01 SLOT 02 SLOT 03 SLOT 04 SLOT 05 SLOT 06 SLOT 07 SLOT 08 SLOT 09 SLOT 10 POWER SUPPLY IC693PWR331 CPU IC693CPU374 COMM ITERFACE IC693CMM311 DO MODULE IC693MDL940 AI MODULE IC693ALG223 EXPANSION RX3I RPU MODULE LAYOUT Rack 0 IC695CHS012 SLOT 00 SLOT 01 SLOT 02 SLOT 03 SLOT 04 SLOT 05 SLOT 06 SLOT 07 SLOT 08 SLOT 09 SLOT 10 SLOT 11 POWER SUPPLY IC695PSA040 CPU IC695CPE305 DO MODULE IC693MDL940 AI MODULE IC693ALG223 EXPANSION Notes: 1. Communication interface module with OIT (IC693CMM311) to be removed. Use serial port on the new CPU for the communication with OIT. Connect and make program changes accordingly. Page 1 of 1 14 of 15
15 WATER TREATMENT PLANTS MICRO PLC LIST Plant RPU Number Manufactur Model Description Location e FCL FCL-BW-RPU-0001 Koyo Direct Logic 06 Backwash Tank Level Selector FCL-SPC-RPU-1221 FCL FCL-FLT-RPU-0001 Koyo Direct Logic 06 Filter Water Flow Summator FCL-SPC-RPU-1521 FCL FCL-ALM-RPU-0001 Koyo Direct Logic 06 Standby Alum Pump FCL-SPC-RPU-1721 FCL FCL-FLO-RPU-0001 Koyo Direct Logic 06 Coagulated Water Flow Summator FCL-SPC-RPU-1724 FCL FCL-TRW-RPU-0001 Koyo Direct Logic 06 Treated Water Flow Summator FCL-TRW-CP-0002 FCL FCL-RW-RPU-0001 Koyo Direct Logic 06 Raw Water Flow Summator FCL-SPC-RPU-1823 FIS FIS-FLT-RPU-0001 Koyo Direct Logic 06 Filter Water Flow Summator FIS-SPC-RPU-1223 FHA FHA-RW-RPU-0001 Koyo Direct Logic 06 Raw Water Flow Summator FHA-SPC-RPU-1221 FHA FHA-FLT-RPU-0001 Koyo Direct Logic 06 Filtered Water Flow Summator Control Room CBP FHA FHA-ALM-RPU-0001 Koyo Direct Logic 06 East or West RW Flow Signal Selector for Alum Pump #1 FHA-ALM-CP-0101 (Pump #0101 Panel) FHA FHA-ALM-RPU-0002 Koyo Direct Logic 06 East or West RW Flow Signal Selector for Alum Pump #2 FHA-ALM-CP-0201 (Pump #0201 Panel) FHA FHA-ALM-RPU-0003 Koyo Direct Logic 06 East or West RW Flow Signal Selector for Alum Pump #3 FHA-ALM-CP-0301 (Pump #0301 Panel) FHA FHA-TRW-RPU-0001 Koyo Direct Logic 06 Treated Water Flow Summator FHA-SPC-RPU-1224 FHO FHO-FLT-RPU-0001 Koyo Direct Logic 06 Filtered Water Flow Summator FHO-SPC-RPU-1721 FHO FHO-ALM-RPU-0001 Koyo Direct Logic 06 Standby Alum Pump Signal Selector FHO-ALM-CP-0501 (Pump #0501 Panel) FHO FHO-PCL-RPU-0001 Koyo Direct Logic 06 Standby PACL Pump Signal Selector FHO-PCL-CP-0701 (Pump #0701 Panel) FHO FHO-POL-RPU-0001 Koyo Direct Logic 06 Standby Polimer Pump Signal Selector FHO-POL-CP-0701 (Pump #0701 Panel) FHO FHO-SPC-RPU-0001 Koyo Direct Logic 06 Raw Water and Treated Water Flow Summators Control Room CBP 15 of 15
OOTORONTO Michael Pacholok, Chief Purchasing Officer
OOTORONTO Michael Pacholok, Chief Purchasing Officer Purchasing and Materials Management Division City Hall, 18 111 Floor, West Tower 100 Queen Street West Toronto, Ontario M5H 2N2 Elena Caruso Manager
More information*REQUIRED* 169 Main Street 700 Plaza Middlesex Middletown, CT T: F:
ADDENDUM COVER & RECEIPT CONFIRMATION SHEET 169 Main Street 700 Plaza Middlesex Middletown, CT 06457 T: 860-343-8297 F: 860-343-9504 www.wright-pierce.com DATE: 9/6/16 ADDENDUM CONSISTS OF (Including this
More informationStandard PACSystems 18-slot Wall (Rear) Mount. 15 Single Width, 8 Double Width (plus one for power supply) RX7i CPU and I/O, VME modules
PACSystems RX7i Programmable Controllers Racks PACSystems RX7i Racks set the pace for the latest PLC technology. They are built to support the high-power PACSystems power supplies along with the latest
More informationPURCHASING DEPARTMENT
PURCHASING DEPARTMENT The bid listed below has had addenda issued. Documents are available over the Internet at http://www.bid.ci.norwalk.ct.us. Adobe Acrobat reader is required to view this document.
More informationCity of Toledo WTP SCADA System Upgrade 2015
City of Toledo WTP SCADA System Upgrade 2015 Dmytryka Jacobs Engineers, Inc. Selected to provide the required services for the WTP SCADA Upgrade Project Local Consulting Engineering Firm (Toledo Cleveland)
More informationPLC 23 DUAL MEDIA FILTERS 5 AND 6 SCADA SYSTEM OPERATION MANUAL. Revision 1.0 April 18, 2006
PLC 23 DUAL MEDIA FILTERS 5 AND 6 SCADA SYSTEM OPERATION MANUAL Revision 1.0 April 18, 2006 PLC 23 DUAL MEDIA FILTERS 5 AND 6 SCADA SYSTEM OPERATION MANUAL Revision 1.0 April 18, 2006 Table of Contents
More informationMinutes - Standing Policy Committee on Finance - April 9, 2015 REPORTS
Minutes - Standing Policy Committee on Finance - April 9, 2015 REPORTS Item No. 4 Water Supervisory Control and Data Acquisition (SCADA) Upgrade Financial Status Report No. 1 for the Period from November
More informationREPORT TO COUNCIL City of Sacramento
REPORT TO COUNCIL City of Sacramento 915 I Street, Sacramento, CA 95814-2604 www. CityofSacramento.org 14 Consent November 10, 2009 Honorable Mayor and Members of the City Council Agreement: Supervisory
More informationPresentation Overview
Upgrading Wilmette s SCADA System How to Keep Your Plant Up and Running during a Major Control System Overhaul Presented at T-CON 2013 Wednesday June 5, 2013 Ray S. Ames Jr., Senior Project Manager, Stanley
More informationTender Number: 4638 Date Created : April 3, 2017 Contact Person: John Brennan Telephone: (902)
Tender Number: 4638 Date Created : April 3, 2017 Contact Person: John Brennan Telephone: (902) 368-5138 Email jebrennan@gov.pe.ca Procurement Services Request for Quotation (RFQ) Tender Source: PROCUREMENT
More informationRaising the standard Upgrading the Series 90-30
Raising the standard Upgrading the Series 90-30 October 2015 Imagination at work Series 90-30 - the most versatile controller in history 2 CPU 311/313/323 CPU 33x/34x/35x/36x Backplane CPU 5 and 10 slot
More informationChecklist for Setting up QuickPanel View MODBUS Connection to a MODBUS Capable GE Fanuc Device with Native Drivers
Checklist for Setting up QuickPanel View MODBUS Connection to a MODBUS Capable GE Fanuc Device with Native Drivers Introduction: This document is a brief introduction to the configuration of the QuickPanel
More informationVersaMax Nano and Micro Controllers
VersaMax Nano and Micro Controllers Don t let size fool you. Although they re easy on valuable panel space, the VersaMax Nano and Micro PLCs are big on features. For high-volume applications where cost
More informationCity Hall,18 th Floor, West Tower 100 Queen Street West Toronto, Ontario M5H 2N2 NOTICE OF INTENDED PROCUREMENT
Michael Pacholok, Chief Purchasing Officer Purchasing and Materials Management Division City Hall,18 th Floor, West Tower 100 Queen Street West Toronto, Ontario M5H 2N2 Joanne Kehoe, Manager Construction
More informationSCADA System Failure Impact Study at Lorne Park and Lakeview WTPs
SCADA System Failure Impact Study at Lorne Park and Lakeview WTPs OWWA Conference 2014 May 5 th London, ON Shawn Xiong - Cole Engineering Jeff Hennings, Jason Little, Claudio Cuffolo - Region of Peel Dale
More informationVendor Name: (A copy must be attached to the Addenda Acknowledgement Form)
#18512 RFP PUBLIC SAFETY VHF RADIO COMMUNICATIONS SYSTEMS ADDENDUM #1 Return to: Dawson County Purchasing Department 25 Justice Way, Suite 2223 Dawsonville, GA 30534 Bid Closing Date: November 26, 2012
More informationThis Datasheet is for the IC693PWR332. High Capacity Power Supply, 12 VDC Input.
This Datasheet is for the IC693PWR332 High Capacity Power Supply, 12 VDC Input http://www.qualitrol.com/shop/p-14698-ic693pwr332.aspx Provides the wiring diagrams and installation guidelines for this GE
More informationWindsor Water Treatment Plant SCADA and Power Upgrades
Windsor Water Treatment Plant SCADA and Power Upgrades John Stuart COO Windsor Utilities Commission Copyright 2011 Rockwell Automation, Inc. All rights reserved. Copyright 2011 Rockwell Automation, Inc.
More informationAppendix B. TechKnowsion PLC and SCADA Programming Proposal
Appendix B TechKnowsion PLC and SCADA Programming Proposal THIS PAGE LEFT INTENTIONALLY BLANK TechKnowsion, Inc. 3305 Vincent Road Pleasant Hill, CA 94523 925.939.8324 Voice 925.280.8324 Fax www.techknowsion.com
More informationMust possess Universal EPA Section 608 certification; OR Type I AND Type II EPA Section 608 certification.
Draft Senior HVAC Mechanic Central District Posting Date: December 14, 2015 Closing Date: December 28, 2015 Salary $18.91/hr to $30.41/hr Internal $18.91/hr to $20.88/hr Overview The Orange County, Florida,
More informationCity Council Agenda Memo
City Council Agenda Memo City Council TO: David A. Vela, Interim City Manager Meeting Date: March 26, 2015 FROM: SUBJECT: Tommy O Brien, Director of Water Utilities Award of Bid to Cardinal Contractors
More informationVersaMax IP. Proficy Machine Edition. Publication Reference Chart
Distributed I/O is designed to offer the ruggedness and reliability of a standard I/O system installed in a NEMA 4 cabinet, without the cost and effort to build the cabinet. is IP67 rated so it can be
More information18.0 CONTROLS PLATFORM AND AUTOMATION
SEWPCC Upgrading/Expansion Conceptual Design Report SECTION 18 - Table of Contents 18.0 CONTROLS PLATFORM AND AUTOMATION...18.1 18.1 INTRODUCTION...18.1 18.2 SYSTEM INFORMATION...18.1 18.3 FUNCTIONAL REQUIREMENTS
More informationPACSystems RX3i Controllers
Controllers is the high performance, modular and scalable control system that supports the PACSystem engine. This rack-based system is built on PCI standards and provides fast, consistent control between
More informationPurchasing Department Finance Group INVITATION TO BID
Purchasing Department Finance Group August 7, 2012 INVITATION TO BID The City of Norwalk, Information Technology Department, is soliciting bids for Computer Server Hardware and VMware vsphere Enterprise
More informationProposal to Join the Locate Alliance Consortium and to Procure a Common Locate Service Provider Toronto Water and Transportation Services
STAFF REPORT ACTION REQUIRED Proposal to Join the Locate Alliance Consortium and to Procure a Common Locate Service Provider Toronto Water and Transportation Services Date: June 1, 2015 To: From: Wards:
More informationComplaint Tracking Form
The City of Toronto, Purchasing and Materials Management Division (PMMD) aims to deliver exceptional, equitable, and accessible customer service. If customers are dissatisfied with the service they receive,
More informationThe Project Charter. Date of Issue Author Description. Revision Number. Version 0.9 October 27 th, 2014 Moe Yousof Initial Draft
The Project Charter Project Title: VDI Data Center Design and Build Project Sponsor: South Alberta Data Centers Inc. (SADC Inc.) Project Customer: The City of Calgary Project Manager: Moe Yousof Document
More informationCity Hall Space Selection 15 Market Square. November 27, 2017
City Hall Space Selection 15 Market Square November 27, 2017 Future City Hall Space Recommendation Recommendation Committee of the Whole recommends that Common Council approve the Offer to Amending Existing
More informationPurchasing Department Finance Group INVITATION TO BID
Purchasing Department Finance Group September 20, 2012 INVITATION TO BID The City of Norwalk, Information Technology Department, is soliciting bids for Computer Software Microsoft Server 2008 plus SQL
More informationVersaPoint I/O. Proficy Machine Edition. Publication Reference Chart
Distributed I/O The VersaPoint Distributed I/O system provides compact flexibility and allows users to install just the right amount of I/O needed for each application. Adhering to open communications
More informationADDENDUM No. 1. Please contact Ed Bonnette, CPPB, CPM, Buyer, Buyer at (970) with any questions regarding this addendum.
Financial Services Purchasing Division 215 N. Mason St. 2 nd Floor PO Box 580 Fort Collins, CO 80522 970.221.6775 970.221.6707 fcgov.com/purchasing ADDENDUM No. 1 SPECIFICATIONS AND CONTRACT DOCUMENTS
More informationSCADA Upgrades to Otay Water Treatment Plant
SCADA Upgrades to Otay Water Treatment Plant Standards Certification Education & Training Publishing Conferences & Exhibits Speaker: Dr. Noune Garounts 2012 ISA Water & Wastewater and Automatic Controls
More informationIMPORTANT PRODUCT INFORMATION
IMPORTANT PRODUCT INFORMATION May 16, 2008 READ THIS INFORMATION FIRST Product: Series 90-30 CPU Modules with Firmware Release 10.74 IC693CPU350-EJ IC693CPU360-EK IC693CPU363-DK This hardware revision
More informationVILLAGE OF DOWNERS GROVE REPORT FOR THE VILLAGE COUNCIL MEETING OCTOBER 5, 2010 AGENDA
VILLAGE OF DOWNERS GROVE REPORT FOR THE VILLAGE COUNCIL MEETING OCTOBER 5, 2010 AGENDA ITEM RES 00-04263 SUBJECT: TYPE: SUBMITTED BY: SCADA System Improvements Resolution Ordinance Motion Discussion Only
More informationStandard PACSystems 18-slot Wall (Rear) Mount. 15 Single Width, 8 Double Width (plus one for power supply) RX7i CPU and I/O, VME modules
PACSystems RX7i Programmable Controllers Racks PACSystems RX7i Racks set the pace for the latest PLC technology. They are built to support the high-power PACSystems power supplies along with the latest
More information2. Volume II, paragraph 1.2.2: Replace the following first paragraph and Table 1-4: Table 1-4: Number of GWA/SCADA Upgraded Facilities
2. Volume II, paragraph 1.2.2: Replace the following first paragraph and Table 1-4: GWA has a few facilities upgraded with supervisory control and data acquisition systems and are presently operating as
More informationINVITATION FOR BIDS For RO PLANT #2 PLC SYSTEMS UPGRADE (CIP# WTR1702)
INVITATION FOR BIDS For RO PLANT #2 PLC SYSTEMS UPGRADE (CIP# WTR1702) BID SUBMITTAL DATE, TIME, & LOCATION: EMAIL QUESTIONS TO: December 8, 2017 @ 2:00 PM Mount Pleasant Waterworks Operations Center 1619
More informationPROJECT TELEMETRY SYSTEM UPGRADES, PHASE 3 IOWA GREAT LAKES SANITARY DISTRICT MILFORD, IOWA. ADDENDUM NO. 2 August 15, 2017
PROJECT 2017-2 TELEMETRY SYSTEM UPGRADES, PHASE 3 IOWA GREAT LAKES SANITARY DISTRICT MILFORD, IOWA CONTRACTOR S BID DATE: PLACE TO FILE FOR CONTRACTOR S BIDS: Tuesday, August 22, 2017, 11:00 A.M. IGLSD
More informationADDENDUM 1 April 13, 2018 Request for Proposals: Professional Services for Server Backup Solution
Following are the questions submitted on or before April 6, 2018, in accordance with RFP specifications. All questions are published verbatim as received, without regard to errors in spelling, punctuation,
More informationMoving. Next Step. of our up on the though is. purchase. Support Team. The exact. time period NOVEMBER, 2010
Next Step Moving Forward Protecting customers today and providing a path for tomorrow FIRST EDITION (T-11-10-05 LCB) NOVEMBER, 2010 Welcomee to the first edition of the Next Step. This news bulletin is
More informationCity of Oxnard. Public Works Integrated Master Plan WATER PROJECT MEMORANDUM 2.8 SCADA ASSESSMENT. FINAL DRAFT December 2015
This document is released for the purpose of information exchange review and planning only under the authority of Hugh Steve McDonald, December 2015, State of California, PE No. 44074 and Tracy Anne Clinton,
More informationCommunity Design Guidelines Document (CDG)
Terms of Reference Community Design Guidelines Document (CDG) Block Plan Stage Supporting Document Required Created through the 2009 City of Brampton/BILD Development Process Review Project Revised Community
More informationPLC 5 BIOTOWERS SCADA SYSTEM OPERATION MANUAL. Revision 1.0 May 15, 2006
PLC 5 BIOTOWERS SCADA SYSTEM OPERATION MANUAL Revision 1.0 May 15, 2006 PLC 5 BIOTOWERS SCADA SYSTEM OPERATION MANUAL Revision 1.0 May 15, 2006 Table of Contents 1 Introduction... 4 2 Revision History...
More informationCORPORATE OVERVIEW. Electrical Instrumentation Automation Design Construction
CORPORATE OVERVIEW Celebrating 25 Years 15+ Years LTI Free Electrical Instrumentation Automation Design Construction 1 1 OVERFLOW INDUSTRIAL Overflow Industrial is an Electrical Engineering and Contracting
More informationCITY OF VANCOUVER ADMINISTRATIVE REPORT
CITY OF VANCOUVER A11 ADMINISTRATIVE REPORT Report Date: May 3, 2007 Author: Dale Bracewell Phone No.: 604.871.6440 RTS No.: 06720 VanRIMS No.: 03-1200-11 Meeting Date: May 15. 2007 TO: FROM: SUBJECT:
More informationPACSystems RX7i IC698CHS009/119
January 2010 The RX7i rack can be used for all RX7i CPU and I/O configurations, Series 90-70 I/O, and VME modules. Backplane connectors are spaced on 0.8" (20.3mm) centers to accommodate single-width RX7i
More informationLawrence Youngblood, Vice President of Corporate Development. Monitoring Remote Operations with Rational SCADA
01110000 01100101 01110010 01101001 01100101 01101110 01100011 01100101 01110011 00100000 01110000 01100101 01110010 01100110 01101111 01110010 01101101 01100001 01101110 01100011 01100101 00100000 01100100
More informationPurpose: Scope: For more detailed info, please refer to the relevant product manuals. Creating the Project:
Purpose: This purpose of this Tech Note is to provide a crude example of setting up Ethernet Global Data (EGD) communications between a PPS (PACSystems) controller and an RX3i Ethernet Network Interface
More informationWater Treatment >>> Core Business B
Water Treatment >>> Core Business B Siu Ho Wan Backup Telemetry System Davenham Engineering Limited Use Allen Bradley PLC 5 w/controlnet capability (~300 I/O) Provide the newest available communication
More informationGFK-2314 New In Stock! GE Fanuc Manuals. rx3i-plc
GFK-2314 New In Stock! GE Fanuc Manuals http://www.pdfsupply.com/automation/ge-fanuc-manuals/rx3i-plc/gfk-2314 rx3i-plc 1-919-535-3180 PACSystems RX3i System Manual www.pdfsupply.com Email: sales@pdfsupply.com
More informationLincoln County, Georgia. Office 365 & Antivirus
Lincoln County, Georgia November 16, 2018 Office 365 & Antivirus Invitation for Bid RFP 18-006 The Lincoln County Board of Commissioners is requesting bids for migration to, and implementation of, the
More informationCity of Toronto Accessibility Design Guidelines 2015
RE: DI3.2 City of Toronto Accessibility Design Guidelines 2015 Update to Disability Issues Committee Presented By: Facilities Management Division June 2 nd, 2015 Presenters: Sunil Sharma, General Manager,
More informationGE Fanuc Automation Programmable Control Products. PACSystems RX3i. System Manual GFK-2314B. May 2005
GE Fanuc Automation Programmable Control Products PACSystems RX3i System Manual GFK-2314B May 2005 Warnings, Cautions, and Notes as Used in this Publication GFL-002 Warning Warning notices are used in
More informationCHAPTER/REGIONAL TECHNOLOGY AWARD - SHORT FORM
CHAPTER/REGIONAL TECHNOLOGY AWARD - SHORT FORM 1. Category (Check one and indicate New or Existing, if applicable) Commercial Buildings New or Existing Institutional Buildings: Educational Facilities New
More informationSolicitation TOSS8187. Notice of Proposed Sole Source: DVR's and External Hard Drives. State of Utah
Solicitation TOSS8187 Notice of Proposed Sole Source: DVR's and External Hard Drives Apr 22, 2008 7:52:38 AM MDT p. 1 Notice of Proposed Sole Source: DVR's and External Hard Drives Bid Number Bid Title
More informationCOUNCIL REPORT. Item Meeting date: August 13, 2018 Engineering & Public Works
Item 7.3.5 Meeting date: August 13, 2018 Department: Prepared by: Reviewed by: SUBJECT: Engineering & Public Works COUNCIL REPORT George Elliott, P.Eng., Director of Engineering & Public Works Greg McClinchey,
More informationREAD THIS INFORMATION FIRST. IC693CPU374 CPU Module with Ethernet Interface
IMPORTANT PRODUCT INFORMATION READ THIS INFORMATION FIRST May 29, 2003 Product: IC693CPU374 CPU Module with Ethernet Interface Introduction IC693CPU374-BE (and later) with CPU Firmware Release 11.03 This
More informationREQUEST FOR PROPOSALS
REQUEST FOR PROPOSALS For the Purchase and Installation of a Security Video Management System with Three Years of Warranty and Maintenance BID NO: 15-15091 Addendum 2 BIDS DUE: October 7, 2015 @ 4:00 PM
More informationAccord Builder. User Guide
User Guide Document: V 3.6 User Guide R01 V3.6 User Guide R01 Page 1 of 110 Table of Contents 1 Introduction... 7 2 General Summary and Definitions... 8 2.1 Accord Platform and Plant... 8 2.2 PLC Control
More informationMassachusetts Water Resources Authority FY17 Proposed Capital Improvement Budget
Massachusetts Water Resources Authority FY17 Proposed Capital Improvement Budget December 16, 2015 FY17 Proposed CIP Fix it First MWRA continues to focus on Asset Protection and Long Term Redundancy initiatives;
More informationTHE CORPORATION OF THE CITY OF STRATFORD
THE CORPORATION OF THE CITY OF STRATFORD Tender Number: T16 17 Replacement of Entrance Phone Systems, Addition of CCTV Camera Systems and Wireless Fidelity/Wireless Internet (WIFI) Systems Throughout the
More informationMOSCAD WIRELESS MONITORING AND CONTROL SOLUTIONS FOR THE WATER/WASTEWATER INDUSTRY
MOSCAD WIRELESS MONITORING AND CONTROL SOLUTIONS FOR THE WATER/WASTEWATER INDUSTRY MOSCAD is a product born of Motorola s 60-year commitment to cutting edge technology. This quest for communications of
More informationPLC 22 WETLANDS & NITRIFYING BIO TOWERS SCADA SYSTEM OPERATION MANUAL. Revision 1.0 May 30, 2006
PLC 22 WETLANDS & NITRIFYING BIO TOWERS SCADA SYSTEM OPERATION MANUAL Revision 1.0 May 30, 2006 PLC 22 WETLANDS & NITRIFYING BIO TOWERS SCADA SYSTEM OPERATION MANUAL Revision 1.0 May 30, 2006 Table of
More informationDark Fiber. INVITATION TO NEGOTIATE No. JOE DUE DATE AND TIME November 2, 2018, 3:00 PM PST
Procurement, Contracts and Materials Management (PCMM) Oregon State University, 644 SW 13 th St, Corvallis, Oregon 97333-4238 T 541-737-4261 F 541-737-2170 http://pacs.oregonstate.edu/ INVITATION TO NEGOTIATE
More informationDallas Municipal Archives Archives Collections Finding Guides and Inventories
Dallas Municipal Archives Archives Collections Finding Guides and Inventories Guide No. 29A City of Dallas Water Works, 1890 1993 (Collection 91060) Processed by: Cindy Smolovik City Archivist Office of
More informationMEETING THE CHALLENGES OF UPGRADING THE PLANT CONTROL SYSTEM YIELDS MAJOR OPERATIONS BENEFITS
MEETING THE CHALLENGES OF UPGRADING THE PLANT CONTROL SYSTEM YIELDS MAJOR OPERATIONS BENEFITS Mike Richardson Water Resources Manager, Cape Fear Public Utility Authority Nan Johnson VP Municipal Business,
More informationMECHANICAL AND ELECTRICAL CONTRACTING, INSTALLATION, TESTING AND MAINTENANCE FOR THE WATER, PROCESS AND NUCLEAR INDUSTRIES
MECHANICAL AND ELECTRICAL CONTRACTING, INSTALLATION, TESTING AND MAINTENANCE FOR THE WATER, PROCESS AND NUCLEAR INDUSTRIES DESIGN INSTALLATION COMMISSIONING TESTING INSPECTION ABOUT US DETECTRONIC IS A
More informationVersaMax* IC200PNS001, IC200PNS002
July 2011 VersaMax* IC200PNS001, IC200PNS002 PROFINET Scanner Modules The VersaMax PROFINET Scanner (PNS) module interfaces a remote node of VersaMax modules to a PROFINET IO-Controller. The PROFINET Scanner
More informationAGENDA ITEM EXECUTIVE SUMMARY
202 AGENDA ITEM EXECUTIVE SUMMARY Agenda Item: Presenter & Title: Wastewater Treatment Plant SCADA System and Fiber Optic Communication System Upgrades Richard Babica, Director of Public Works Date: May
More informationLou Di Gironimo, General Manager Toronto Water, City of Toronto Toronto, Ontario, Canada
Lou Di Gironimo, General Manager Toronto Water, City of Toronto Toronto, Ontario, Canada Toronto Water Overview Serves 3.1 million residents and businesses Over $26 billion in infrastructure Infrastructure
More informationRequest for Proposals. Information Technology Consultant and Network & Information Technology Support Services
Request for Proposals Information Technology Consultant and Network & Information Technology Support Services July 18, 2018 General Description The City of Greenville is looking to select a qualified firm
More informationRequest for Proposal George West Independent School District ERate
Request for Proposal ERate 2015-2016 Infrastructure for New Wings at George West High School and George West Elementary School Due: March 9, 2015 2:00 PM Superintendent: Ty Sparks ERate 2015 RFP:, George
More informationREQUEST FOR PROPOSAL CITY OF WARRENSBURG 102 SOUTH HOLDEN STREET WARRENSBURG, MISSOURI 64093
REQUEST FOR PROPOSAL CITY OF WARRENSBURG 102 SOUTH HOLDEN STREET WARRENSBURG, MISSOURI 64093 PROPOSAL CLOSING: September 15, 2017 DATE OF PROPOSAL: August 14, 2017 CONTACT PERSON: GARY SWANSON, COMPUTER
More informationDEE JASPAR & ASSOCIATES, INC. CONSULTING CIVIL ENGINEERS 2730 UNICORN ROAD, BLDG A BAKERSFIELD, CA PHONE (661) FAX (661)
DEE JASPAR & ASSOCIATES, INC. CONSULTING CIVIL ENGINEERS 2730 UNICORN ROAD, BLDG A BAKERSFIELD, CA 93308 PHONE (661) 393-4796 FAX (661) 393-4799 ARVIN COMMUNITY SERVICES DISTRICT NOTICE TO PLANHOLDERS
More informationChapter 1 Introduction to Outside Plant
Chapter 1 Introduction to Outside Plant Chapter 1 offers an overview of outside plant (OSP) fundamentals. An introduction to standardization and valuable resources for the OSP designer are also included
More informationDEVELOPMENT OF OPERATIONAL MANUALS. Jason Whittaker. Goulburn Valley Water
DEVELOPMENT OF OPERATIONAL MANUALS Paper Presented by : Jason Whittaker Author: Jason Whittaker, Technical Officer, Goulburn Valley Water 67 th Annual Water Industry Engineers and Operators Conference
More informationPACSystems* RX3i IC694ALG232
November 2015 PACSystems* RX3i IC694ALG232 Advanced Diagnostics 16 Channel Input Analog Voltage Module The PACSystems* RX3i 16-Channel Analog Voltage Input module provides 16 single-ended or 8 differential
More informationSTATEMENT OF QUALIFICATIONS
STATEMENT OF QUALIFICATIONS Engineering for Water & Wastewater About NLS NLS Engineering is a growing firm located in Ontario, Canada. We are a team of multi-disciplined engineering and integration experts
More informationCity of Winter Garden REQUEST FOR PROPOSAL RFP CR Mail and Fulfillment Services LEGAL ADVERTISEMENT CITY OF WINTER GARDEN
City of Winter Garden REQUEST FOR PROPOSAL Mail and Fulfillment Services LEGAL ADVERTISEMENT CITY OF WINTER GARDEN REQUEST FOR PROPOSAL (RFP) NO. CR18-001 FOR A VENDOR TO PROVIDE DOMESTIC AND INTERNATIONAL
More information9611 SE 36th Street Mercer Island, WA Request for Proposal (RFP #17-11) City of Mercer Island Contracted Services for:
9611 SE 36th Street Mercer Island, WA 98040 Request for Proposal (RFP #17-11) City of Mercer Island Contracted Services for: WATER AND SEWER CONTROL SYSTEM - HARDWARE/SOFTWARE Release Date: November 21,
More informationSCHENDT ENGINEERING PRIOR EXPERIENCE
Mitchell Hall Renovation US Air Force Academy, Colorado Corp. was the prime consultant for this project. The project generally consisted of replacing all of the air handling units, exhaust fans, air curtains,
More information1200 West 7th Street, Los Angeles, CA Smart.
Overview 1200 West 7th Street, Los Angeles, CA 90017 West 7 Center is conveniently located at 1200 West 7th Street in downtown Los Angeles near the 10 and 110 freeway. This tier III datacenter facility
More informationRemote Pump Station Management Solution
Application Scenario Ordering Configuration Table How Remote Management Optimizes Pump Station Effectiveness Energy & Environment SRP-ERE001 Optimize Overall Pump Station Effectiveness Package Offering
More informationComprehensive Networking Solutions
Comprehensive Networking Solutions End to End Networking Solutions in the Water and Wastewater Sectors Standards Certification Education & Training Publishing Conferences & Exhibits Aug 5-7, 2014 Orlando,
More informationThe Internet Society. on behalf of. The IETF Administrative Oversight Committee. Request for Proposal. Three Software Tools to Support the RFC Editor:
The Internet Society on behalf of The IETF Administrative Oversight Committee Request for Proposal Three Software Tools to Support the RFC Editor: RFClint, SVGcheck, and XMLdiff Date of Issuance: October
More informationPLC 4 PRIMARY SEDIMENTATION SYSTEM SCADA SYSTEM OPERATION MANUAL. Revision 1.0 May 15, 2006
PLC 4 PRIMARY SEDIMENTATION SYSTEM SCADA SYSTEM OPERATION MANUAL Revision 1.0 May 15, 2006 PLC 4 PRIMARY SEDIMENTATION SYSTEM SCADA SYSTEM OPERATION MANUAL Revision 1.0 May 15, 2006 Table of Contents 1
More informationEvaluation of Jackson and Saylor Sanitary Sewer Lift Station During July 23-24, 2010 Storm Event. Presented by:
City of Elmhurst Evaluation of Jackson and Saylor Sanitary Sewer Lift Station During July 23-24, 2010 Storm Event Christopher B. Burke Engineering, Ltd. Presented by: Christopher B. Burke, PhD, PE, D.WRE,
More informationBy Raymond Grosch Senior System Analyst IntelliSys Inc.
IntelliSys Inc. White Paper 09 W. Washington Chicago, IL 60606 800.7.9977 www.intellisyssoftware.com Keywords: SystemVIEW, process visualization, SCADA (Supervisory Control And Data Acquisition), HMI (Human
More informationAPPENDIX 4 to LGIP INTERCONNECTION FACILITIES STUDY AGREEMENT
APPENDIX 4 to LGIP INTERCONNECTION FACILITIES STUDY AGREEMENT THIS AGREEMENT is made and entered into this day of, 20 by and between [Customer Name (Project Name, QXXXX)], a [Type of company] organized
More informationXXXX. Bear Creek Hydro Generation Project. Interconnection Facilities Study
XXXX Bear Creek Hydro Generation Project Interconnection Facilities Study Report No. SPA 2005-33 August 2005 System Planning (Lower Mainland & Vancouver Island) British Columbia Transmission Corporation
More informationFACILITIES ADVISORY COMMITTEE SPACE MODIFICATION REQUESTS
FACILITIES ADVISORY COMMITTEE SPACE MODIFICATION REQUESTS FALL 2017 Presented by Harun Biswas December 6, 2017 FACILITIES ADVISORY COMMITTEE ROLE AND ACTIVITIES Purpose: The Committee established in 2010.
More informationExxonMobil Gas Well Automation Systems.
Gas Well De-Liquification Workshop Adams Mark Hotel, March 5-7, 007 ExxonMobil Gas Well Automation Systems. Kevin D. McCain ExxonMobil USP Artificial Lift Automation Coordinator. Tim Jumper ExxonMobil
More informationImportant Product Information
Important Product Information April 15, 2009 READ THIS INFORMATION FIRST Product: IC693CPU366 CPU Module with PROFIBUS Master Upgrades IC693CPU366-CD with CPU Firmware Version 10.74 PROFIBUS Firmware Version
More informationCombustionMaster Control Solutions. Unique Combustion Control for Gas and/or Oil-Fired Boilers
CombustionMaster Control Solutions Unique Combustion Control for Gas and/or Oil-Fired Boilers Unique Combustion Control Solution for Gas and/or Oil-Fired Boilers The CombustionMaster system from Rockwell
More informationADDENDUM NO. 1. Kansas City Area Transportation Authority (KCATA) 1350 E. 17 th Street Kansas City, Missouri Point to Point Fiber Connection
Issue Date: December 9, 2016 ADDENDUM NO. 1 Kansas City Area Transportation Authority (KCATA) 1350 E. 17 th Street Kansas City, Missouri 64108 Project #16-7029-25 This Addendum is hereby made a part of
More informationAndrea Sappleton, Assistant Director of Purchasing
BID ADDENDUM NO. 1 COVER SHEET TO: FROM: Prospective Bidders Andrea Sappleton, Assistant Director of Purchasing DATE: July 6, 2015 RE: RCNJ Bid No. 15-007A Magazine Printing Services The attached Addendum
More informationPACSystems* RX3i IC694ALG233
November 2015 PACSystems* RX3i IC694ALG233 Advanced Diagnostics Analog Current Input Module 16 Channel The PACSystems* RX3i 16-Channel Analog Current Input module provides 16 single-ended input channels.
More informationCONTRACT DOCUMENTS. for the CIGAR LAKE: RECLAIMED WATER DISTRIBUTION PUMP STATION (ITB - U ) PREPARED BY
Addendum No. 2 December 19, 2006 CONTRACT DOCUMENTS for the CIGAR LAKE: RECLAIMED WATER STRIBUTION PUMP STATION (ITB - U - 07-04) PREPARED BY CPH ENGINEERS, INC. P.O. BOX 2808 SANFORD, FL 32772-2808 PHONE:
More informationHPP Kidatu (4x50 MW) - Control System Upgrade AUTOMATION
HPP Kidatu (4x50 MW) - Control System Upgrade AUTOMATION Location - Plant - End User About Location Kidatu is a town in southern Tanzania, located in Kilombero district, Morogoro region. The local population
More information