s SINUMERIK 840D sl

Size: px
Start display at page:

Download "s SINUMERIK 840D sl"

Transcription

1 s SINUMERIK 840D sl SINUMERIK 840D sl, CNC system sftware 6 axes ) 6FC5850-1XG21-5YA0 with HMI-sl, 6 languages, n CF Card; with license ) Exprt 6FC5850-1YG21-5YA0 SINUMERIK 840D sl, CNC system sftware 31 axes ) 6FC5850-3XG21-5YA0 with HMI-sl, 6 languages, n CF Card; with license ) Exprt 6FC5850-3YG21-5YA0 Infrmatin n the installatin and peratin fr SINUMERIK NCU 710.2, NCU 720.2, NCU PN, NCU 730.2, NCU PN. The CNC sftware 2.6 SP1 HF11 (internal versin ) cmprises the fllwing cmpnents: NCK Sftware V SNCK V PLC OpSys V (PLC 317) PLC OpSys V (PLC 319) PLC-FB15 V CP V MCP Client V SINAMICS-Sftware V Sinumerik Operate V LinuxBase V SNC V Cycles V Functinal imprvements included in Operate cmpared t Versin 2.6 SP1 HF10 PR number AP Funktinsverbesserungen Operate gegenüber Versin 2.6 SP1 HF9 PR- Nummer AP Funktinsverbesserungen NCK gegenüber Versin 2.6 SP1 HF8 PR. Nummer AP AP AP AP Functinal imprvements included in NCK and the drive as cmpared t Versin 2.6 SP1 HF7 PR number AP AP AP AP Functinal imprvements included in Operate as cmpared t Versin 2.6 SP1 HF5 PR number Siemens AG 2013 I DT MC R&D 51 Page 1 f 41

2 AP Functinal imprvements included in NCU7xx.PN with PLC319 as cmpared t Versin 2.6 SP1 HF6 RQ number AP Functinal imprvements included in NCK as cmpared t Versin 2.6 SP1 HF5 PR number AP Functinal imprvements included in Operate as cmpared t Versin 2.6 SP1 HF4 PR number AP AP AP AP AP AP AP AP AP Functinal imprvements included in Cycles as cmpared t Versin 2.6 SP1 HF4 PR number AP Functinal imprvements included in NCK as cmpared t Versin 2.6 SP1 HF3 PR number AP AP AP AP AP AP AP Functinal imprvements included in Operate as cmpared t Versin 2.6 SP1 HF3 PR number AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP Functinal imprvements included in Cycles (technlgy, measurement, JbShp) as cmpared t Versin 2.6 SP1 HF3 PR number AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP Siemens AG 2012 I DT MC R&D 51 Page 2 f 41

3 AP AP AP AP AP AP AP AP AP AP AP AP Functinal changes / extensins f the cnfigurable machine data - New MD $MCS_REV_2_BORDER_TOOL_LENGTH - New MD $MNS_BLOCK_SEARCH_MODE_MASK_JS Bitmask fr available search run mdes (ShpMill, ShpTurn single-channel) - MD DISP_PLANE_TURN write permissin nw SIEMENS Functinal imprvements included in NCK as cmpared t Versin 2.6 SP1 HF2 PR number AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP Functinal imprvements included in Operate as cmpared t Versin 2.6 SP1 HF2 PR number AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP AP Functinal imprvements included in cycles (technlgy, measuring, JbShp) as cmpared t Versin 2.6 SP1 HF2 PR number AP AP AP AP AP AP AP AP AP AP AP AP AP AP Installing the CNC sftware: The NCU service system >= V n a USB stick is required t install the CNC sftware. The sftware can be installed fr the first time using the NCU service system and TCU with full keybard r using WinSCP. Installatin withut keybard r WinSCP is nly pssible using a USB stick that has been prepared fr autmatic upgrade (refer t 1.5). The sftware may nly be installed n a SanDisk CmpactFlash GB. The Order N. [MLFB] f the empty card is 6FC5313-5AG00-0AA0. Optinally, yu can use a CF Card 8GB 6FC5313-6AG00-0AA Installing the NCU service system n a USB stick: The NCU service system is available as USB stick image in the directry emergency_btsys_ncu f the DVD supplied. The installdisk.exe prgram fr cpying is lcated next t it. Cnnect a USB stick >= 512MB, preferably Siemens 6ES7648-0DCx0-0AA0, t yur PG r PC (with Windws XP) and determine the assciated Siemens AG 2012 I DT MC R&D 51 Page 3 f 41

4 driver letters. Call up installdisk t cpy the NCU service system t the USB stick: installdisk --verbse --blcksize 1m <Image file> <Drive letter:> Example: ( -- means 2x minus characters) installdisk --verbse --blcksize 1m D:\ emergency_btsys_ncu\linuxbase-512m.img X: This means that the capacity f each USB stick is limited t 512MB. Alternatively: installdisk --verbse --blcksize 1m D:\ emergency_btsys_ncu\linuxbase-512m.img X: If the resize.img is used, then after it has been dwnladed, an NCU must be bted frm this USB stick s that the image n the stick is unzipped and the FAT partitin is generated. This means that the full capacity f the USB stick is therefre available. The cmmand specified abve is preferably executed in a DOS shell. T d this, yu require administratr rights n yur PG/PC After cmpleting installdisk, remve the USB stick frm the PG / PC and re-insert it int the PG / PC. Under Windws, yu will nw see an empty USB stick. Nw, cpy the required CNC sftware (file with the.tgz extensin) t this USB stick frm the DVD supplied, directry ncu_sw. The USB stick can nw be inserted in ne f the tw USB cnnectrs f the NCU 7x0. When it is pwered-up, the NCU bts frm this USB stick. Operatr cntrl is either frm a TCU that is cnnected t the NCU r via PG / PC using WinSCP under "Open Terminal". The use f the NCU service system is described in the dcumentatin /IM7/ n the DVD supplied. 1.2 Upgrading an NCU 7x0.2 with CNC-SW 2.6 preliminary A SanDisk 1GB CF card is required! It is nt permissible t upgrade frm ther sftware releases. A new installatin is then required! It may then be necessary t bserve Sectin 9.5 upgrading cycles. Fr an upgrade, all user data n the CF card in the directries /user, /addn, /em and the license key is kept. When upgrading systems with several NCUs / PCU50, please carefully nte Sectin 7 regarding netwrking! Bt the NCU frm the USB stick (refer t 1.1). Using F3, select the service shell. Lg-n as user "manufact". In this case, it may be necessary t use an external keybard as the user name must be written using lwer-case letters. After the $ peratr prmpt f the service shell, enter the fllwing cmmand: sc restre -update /data/<cnc-sw>.tgz The sftware update has been cmpleted when the $ prmpt reappears. Remve the USB stick. Bt the NCU by pwering it dwn/up again. The PLC, drives and NC can then be cmmissined. 1.3 New installatin IMPORTANT: With this prcedure, the cntents f the CF card are cmpletely deleted, this als applies fr an empty CF card. Bt the NCU frm the USB stick (refer t 1.1). Using F3, select the service shell. Lg n as user "manufact" - fr an empty CF card with "admin", passwrd "SUNRISE". In this case, it may be necessary t use an external keybard as the user name must be written in lwer-case letters. After the $ peratr prmpt f the service shell, enter the fllwing cmmand: sc restre -full /data/<cnc-sw>.tgz The sftware installatin has been cmpleted if the $ prmpt reappears. Remve the USB stick. Bt the NCU by pwering it dwn/up again When bting fr the first time with TCU(s), the TCU(s) must be lg nt the system. The TCU name (default TCUx) and the address f an assigned MCP must be specified. The PLC, drives and NC can then be cmmissined. Siemens AG 2012 I DT MC R&D 51 Page 4 f 41

5 1.4 Systems withut TCU If there is n OP with TCU t perate the NCU service system when installing the sftware crrespnding t 1.2 r 1.3, then peratin is als pssible frm PCU50 r PC/PG using WinSCP (Cmmands / Open Terminal) r VNC viewer. Under certain circumstances, it is nt pssible t install the sftware withut an NCU service system n the USB stick because there is nt enugh free memry space n the CF card. 1.5 Autmatic upgrade using a bt-capable USB stick: Using an apprpriately prepared USB stick >= 1GB, it is pssible t execute an autmatic "restre -updated" r "restre -full". In this case, a script (autexec.sh) and the CNC sftware must be cpied t the stick. It is nt permissible t change the name f the script. The CNC sftware cpied t the stick must be renamed update.tgz r full.tgz. The SIM/NCK rtary switch n the NCU must then be set t psitin 7 and the NCU bted frm the stick. The script nly runs when the switch is in the 7 psitin. Otherwise, the NCU bts frm the stick and a branch is then made int the service menu. Depending n the designatin f the CNC sftware, the script decides whether a "restart -update" r a "restre -full" is t be carried ut. In additin, befre the restre, the script runs a data backup f the CF card. The prgress made in the individual script steps can be tracked n the 7-segment display r als at the internal SINUMERIK Operate. The precise significance f the displays and the individual steps are described in a separate dcument. The script is available n the DVD supplied. 2. Excerpt f the new functins frm NCK Mdified braking behavir at Stp D Stpping within the cnfigured Stp D time is nw ensured. The directin f spindle rtatin can be activated via a MD bit and adapted t the rtatinal directin f M3/M4 when tapping. Prgevent-pwern ASUPS can be prcessed despite pending alarms. The max. number f part prgrams has been increased t Multi-channel sequencer prgramming PROGRAMSYNC. Multitls Mnitring fr maximum tl speed and acceleratin ADI4-Bard with NCU7xx.PN (PLC319) Online Help frm the PLC symbl table NC-cntrlled Extended stpping and retractin ESR. 3. Ntes: After installing the CNC Sftware Versin 2.6 SP1 n the CF card, a general reset must be made fr the NCU and PLC: SIM/NCK switch in psitin 1, PLC switch in psitin 3 and then pwer-dwn/pwer-up. NCU730: When alarm "2120 NCK fan alarm" is utput, then an immediate respnse (apprx. 20 secnds) must be realized in the PLC prgram and the axes shut dwn in a cntrlled fashin, if a duble-fan mdule is nt being used. NCU710 / NCU720: The NCU des nt bt if either the fan mdule is nt available r if it is defective. This nly applies t the NCU730 equipped with a duble fan mdule if bth f the fans have failed. Alarm Pwer ON after pwer failure "%1 data was restred, f which %2 machine data, %3 errrs" If %3 - the number f errrs ccurred - is greater than zer, then it is nt recmmended t cntinue prcessing with the data. In rder t avid subsequent prblems, an actual data back-up shuld be read-in (dwnladed). It is nt always pssible t prt an NCK series cmmissining archive frm 840D pwer line t 840D sl withut prcessing. Befre verwriting a licensed CF card, it is abslutely necessary t back up the license key. The key is included in the 'keys.txt' file and is lcated in the /card/keys/sinumerik path. The key can be backed-up e.g. using WinSCP frm the PG/PC. Siemens AG 2012 I DT MC R&D 51 Page 5 f 41

6 The licenses are permanently linked t the particular CF card (card ID) and can nly be used n this card. Data backups shuld be read-in (dwnladed) in the fllwing sequence - NC, PLC, drive. It makes sense t separately generate the NC, PLC and drive archives. Cntur handwheel and velcity verride using the handwheel are nly released with Prfibus MCP. The reset knb at the NCU allws the NCU mdule t restart. It cannt be guaranteed that the cmplete system can be restarted fr all cnfiguratins. This als applies t the PI service frm the PLC with FB4. A template f the actual standard basesys.ini is available in the catalg /card/siemens/system/etc. Prt 102 n X130 is interlcked as standard. If the cntrl is t be accessed via X130 using Step 7 r a SINUMERIK Operate, then prt 102 must be enabled. This can be dne by making the fllwing entry in the file /user/system/etc/basesys.ini: [LinuxBase] FirewallOpenPrts=TCP/102 If required, prt 5900 can als be enabled fr an external VNC viewer. The Ethernet handwheel f the HT2 is cnnected (marshalled) t the fifth handwheel interface. Example fr three Ethernet handwheels. The third handwheel is lcated in HT2: MD11350[0]= [0]= [0]=1 MD11350[1]= [1]= [1]=2 MD11350[2]= [2]= [2]=5 HT2: The PLC applicatin example fr the HHU (handheld unit), included in the tlbx fr Pwerline, cannt be transferred t the HT2 withut first making sme changes. The variable descriptins f the NCVAR must be adapted. FC13 nw supprts the visualizatin f fur lines. As a cnsequence, the significance f the "ROW" parameter has changed as fllws: 0 = n display utput 1 = 1st line 2 = 2nd line 3 = line 1 and line 2, alternating 4 = 3rd line 5 = line 1 and line 3, alternating 8 = 4th line F = autmatic change f all lines The cntents f the display must be saved in the "ChrArray" field, type string[64]. Example f the parameter setting fr the HT2 at FB1 (OB100): BHG :=5 BHGIn :=DB100.BhgIn_170 BHGOut :=DB100.BhgOut_150 BHGStatSend :=DB100.DBD80 BHGStatRec :=DB100.DBD84 BHGInLen := BHGOutLen := BHGTimeut := BHGCycl := BHGRecGDN :=2 // crrespnds t the setting f the rtary switch * the cnnectin bx r the MPP. BHGRecGBZN :=2 // crrespnds t the setting f the rtary switch * the cnnectin bx r the MPP. BHGRecObjN :=1 BHGSendGDN :=2 BHGSendGBZN :=1 BHGSendObjN :=1 BHGMPI BHGStp BHGNtSend * Rtary switches S1 and S2 at the cnnectin bx r MPP are used t define the DIP number with which the participant registers itself in the system (here, S1=0, S2=2). ). Address "0" is nt permissible, as with this setting, the DHCP server cannt allcate any addresses. HT2: The upper key rw is displayed in the PLC as fllws: Siemens AG 2012 I DT MC R&D 51 Page 6 f 41

7 The key n the tp left (SK1) is mapped in EBn+2 Bit 1 SK2 = EBn+2 Bit 6 SK3 = EBn+3 Bit 7 SK4 = EBn+4 Bit 4 The LEDs f the upper key rw can be activated by the PLC as fllws: Signals t handheld unit ABn+0 Bit 0 crrespnd t LED tp-left Bit 1 fr 2nd LED frm tp left, etc. HT2: Display f 12 characters incl. the decimal pint and sign with FC13. In rder t be able t use the extended display at the HT2, the values (these are generally the psitin values) must be transferred t the FC13 in the real 2 frmat. In rder that FC13 can apprpriately prcess the values, the Parameter DataType must be set t B#16#30. The values must be transferred in exactly the same way as they are read frm FB2 / FB5 in the real 2 frmat. It is nt pssible t interpret the values between utput FB2 / FB5 and input in FC13. The values read-in frm FB2 / FB5 in the real 2 frmat must be apprpriately cnverted in FC13. The Digits parameter specifies the number f decimal places (value range 1..9). The display update is managed in FC13. The signals "Acknwledge numerical display" in the EBm+5 and "New data fr selected line" in ABm+1 n lnger have t be intercnnected in the PLC. Example: - displaying fur axis psitin values that are read with FB2. - The results f the read peratin frm FB2 are saved in the real 2 frmat in DB399.DBX0.0,... DB399.DBX8.0, etc. - the display is t three places after the decimal pint. FUNCTION FC 399 : VOID TITLE = { S7_language := '9(1) English (USA) :23:07' } VERSION : 0.0 CODE_VERSION1 VAR_TEMP END_VAR BEGIN NETWORK TITLE = NETWORK //attentin: FC13 writes t AB1 f HT2 //1st axis actual psitin t rw 1 SET ; = DB399.DBX 150.7; //always ne in QB m.7 CALL FC 13 ( Rw := B#16#F,// display fur rws ChrArray := DB106.display, // string array[64] Cnvert := TRUE, Addr := DB399.DBX 0.0, // 1st result frm FB2 DataType := B#16#30, StringAddr := 16, // rw 1 address in string Digits := B#16#3, Errr := M 610.0); //2nd axis actual psitin t rw 2 CALL FC 13 ( Rw ChrArray Cnvert := B#16#0, := DB106.display, := TRUE, Siemens AG 2012 I DT MC R&D 51 Page 7 f 41

8 Addr := DB399.DBX 8.0, // 2 nd result frm FB2 DataType := B#16#30, StringAddr := 32, // rw 2 address in string Digits := B#16#3, Errr := M 610.1); //3rd axis actual psitin t rw 3 CALL FC 13 ( Rw := B#16#0, ChrArray := DB106.display, Cnvert := TRUE, Addr := DB399.DBX 16.0, // 3 rd result frm FB2 DataType := B#16#30, StringAddr := 48, // rw 3 address in string Digits := B#16#3, Errr := M 610.2); //34th axis actual psitin t rw 4 CALL FC 13 ( Rw := B#16#0, ChrArray := DB106.display, Cnvert := TRUE, Addr := DB399.DBX 24.0, // 4 th result frm FB2 DataType := B#16#30, StringAddr := 64, // rw 4 address in string Digits := B#16#3, Errr := M 610.3); BE ; END_FUNCTION Alarm 46xx: The machine data fr the Ethernet handwheel must be checked. Example fr the first handwheel: MD11350[0]=7, 11351[0]=1, 11352[0]=1 Traversing the spindle with limited trque (Fcn) r traversing the spindle t a fixed stp: The pwer displayed at the SINUMERIK Operate is calculated frm the limited trque as 100% and displayed. Frm NCK >= V nwards and ADI4 bard V , the ADI4 bard can be perated at the 840D sl with internal PLC 317. Dbsi 1, just like befre, has nt been released in cnjunctin with SINUMERIK and integrated drive cntrl. An NCU Bis >= V1.4 is required fr perating a 1GB CmpactFlashCard in an NCU730. The BIOS is nly available thrugh e_supprt as an upgrade is nly required very infrequently. Starter, in cnjunctin with 840 D sl, has, as befre, nly been released fr diagnstics. If the number f part prgrams set by the machine data apprximately crrespnd t the number f actually used part prgrams, the value in the machine data must be increased (as a result f the additinal cycles). Interplatry traversing f psitining axes is prevented with Alarm 8031 "...axis has n IPO functinality." SPI and PW are keywrds (they have always been keywrds) and cannt be used as axis identifiers. The functin G643 (internal blck blending) has been released fr applicatins in the tl change area (e.g. ptimizing the apprach t the tl change psitin). It has nt been released fr applicatins in the machining prcess itself. The functin G644 (blending with pssible dynamic perfrmance) has been released fr applicatins in the tl change area (e.g. ptimizing the apprach t the tl change psitin). It has nt been released fr applicatins in the machining prcess itself. Sftware versin, max. 6 axes: The standard pre-assignment fr the number f axes is defined as 3. The "extended measuring" functin with the distributed measuring input at the SINAMICS mdules des nt functin (MEAC, MEASA, MEAWA). N channel gaps are pssible in a system with a maximum f tw channels. Access t drive data via system variables $nn_nn has nt been released. Only the system variables Siemens AG 2012 I DT MC R&D 51 Page 8 f 41

9 transferred in telegram 116 are pssible. ESR has nt been released. Nw, analg t the 840Di functinality, ASUBs can be started via Prfibus PLC I/O. The machine data shuld be selected the same as fr 840Di. There are n fast NCK I/O (peripherals) that are mapped in the DB10 f the PLC. Hwever, the knwn ASUB start ptins (frm DB10 r FC9 via PLC prgram) are still pssible. Fast ET200 Simatic mdules can be used t replace the DMP mdules used fr Pwerline. In this case, fr the PLC317 - in cnjunctin with NCK >= V there is a pssibility f perating ne f the tw Prfibus lines in clck cycle synchrnism (details n this are prvided in a separate descriptin). When using 31-axis sftware n an NCU710.1, 6 f the 31 axes can be used and 4 channels frm 10 channels. Machine data $MN_MAXNUM_PLC_CTRL_AXES is n lnger in the data set. It has been replaced by MD MD $MN_POSCTRL_CYCLE_DELAY must be zer. Check the existing data backup. Machine data $MA_RATED_OUTVAL[] must have a value f zer. IMD (Integrated Mnitring & Diagnstic) : The feedback signal in the GUD variable _PM_MISSING_TOOL_REFRESH after writing 1 t variables is nly updated when the screen changes. Safety: There is a new handling ptin that invlves synchrnized actins r the synchrnized actin elements. Up t status 1.3 (NCK 62), using the SI ptin - synchrnized actin level 2 was simultaneusly internally set. This meant that the channel MD 28250, NUM_SYNC_ELEMENTS was able t be set t a value > 159. This situatin changes with NCK release 67. The synchrnized actin level 2 is n lnger included in Safety. This is the reasn that there is a new machine data in which the synchrnized actin elements fr SAFE.SPF are defined, MD 28251, NUM_SAFE_SYNC_ELEMENTS. With ptin SLP_I_O=1, a maximum f 500 can be written t this machine data - and fr SPL_I_O=2, a maximum f Hwever, the number (cunt) f required synchrnized actin elements shuld be determined in rder t avid that the perfrmance is unnecessarily reduced. The number (cunt) f the free SI synchrnized actin elements can be read using the system variable $AC_SAFE_SYNAC_MEM. If this variable is called befre the start and after SAFE.SPF has run, then the difference is the number (cunt) f elements that SAFE.SPF ccupies. This difference shuld be entered int MD with a certain amunt f reserve. An index 1-5 must be specified when writing t MD using synchrnized actins. Safety: Changed checksums fr safety functinality integrated in the drive. As a result f the new safety functins integrated in the drive, the checksums fr these functins must be re-acknwledged. T d this, "95" (Safety-cmmissining) must be entered int parameter p10. The parameters f the actual checksums must then be cpied t the parameters f the reference checksums: p9798 t p9799 p9898 t p9899 Then, p10 must be again set t zer. As a cnsequence, the values are autmatically saved (p971 is set t 1). Wait until the data has been cmpletely saved. The peratins can als be initiated in HMI-Advanced under IBN/NC/Safety Integrated using the sftkeys "Activate cmmissining mde" and "Deactivate cmmissining mde". The help functin M6 is n lnger utput as standard a blck search. Cunter-measure: Change the help functin grup in MD $MC_AUXFU_PREDEF_GROUP[5] int a free grup. If the value f MD18210 deviates frm the standard pre-assignment, in rder t upgrade frm SW1.4 / 2.4 t SW1.5 / 2.5, then as a minimum, MD18210 must be increased by 21 MB DRAM. HT2 can be used as handheld peratr unit frm sftware release 1.5 HF5 / 2.4 SP1 and higher. Depending n the setting in basesys.ini, the HT2 is bted frm the master (refer t the general infrmatin n netwrked systems). The master can be an NCU as well as als a PCU 50. Tl manager: There is a new handling ptin. If several real magazines are being used, then this can be enabled using an ptin. A real magazine is included in the basic scpe. Siemens AG 2012 I DT MC R&D 51 Page 9 f 41

10 Fr cmpatibility reasns, the previus ptin $ON_TECHNO_FUNCTION_MASK Bit4=1 must still be set t 1 - hwever it is nt included in the license handling. Tlbx frm V and higher and Step 7 frm V5.4 SP2 and higher are required. The retentive memry f the PLC 319 is limited t 256kB. Deleting PLC 319: After deleting the PLC, by actuating the PLC rtary switch r frm Step 7, the PLC prgram is subsequently autmatically reladed. If PLC initializatin is initiated using the peratr actin - PLC switch in psitin 3 and pwer ff/n, then the PLC prgram is nt autmatically laded. This is als then n lnger realized with the abve mentined sequence f peratr actins. The actual cycle time is n lnger available in DB5 but in DB8. The cycle time can als be called via the start infs f the OB1. The PLC mdule IM153-2 MLFB 6ES AA02-0XB0 cannt be used. Cunter-measure: 6ES AA03-0XB0 The PLC series (standard) cmmissining archive must be generated when the PLC is in the stp state. Otherwise, it cannt be guaranteed that the PLC resumes cyclic peratin after lading the data backup. The star/delta changever with FC17 requires Sinamics parameters. Prerequisites: The apprpriate DDS/MDS must be set-up in the drive! P827[0] P827[1] P827[n] must nt be equal t ne anther! The cntactr is changed ver by the applicatin => P833, bit0=1 Pulses are cancelled by the drive => P833, bit1=0 PLC utput setting: Star peratin, this is the reasn that when bting (pwering-up), a "1" shuld be set in the axis DB bit 21.5 The service interface X127 f the NCU shuld nly be used fr cmmissining and service. The machine cntrl panel (MCP) is perated n Prfibus r Ethernet. Mixed peratin is nt permissible. Prfibus1 must be cnfigured s that the sftkeys CU, Infeed, Drives are displayed at the SINUMERIK Operate. Fr PLC 319, Prfibus diagnstics using FB125 are nt pssible. PLC 319, PrfiNet functinality: CBA PLC cmmunicatin has been released. Blcks FC1007 AG_LOCK, FC1008 AG_UNLOCK, FC1010 AG_CNTRL have nt been released. The FORCEN [FORCING] functin f the PLC in cnjunctin with 840D sl has nly been released. It is pssible with the PLC317 frm PLC perating system >= V (e.g. 2.4 SP1 HF11) / PLC319 and higher with a PLC perating system >= V (e.g. 2.4 SP1 HF11) and higher. Fr 840D sl, it is nt permissible that the VDI interface signal DB10.DBX57.3 is cnnected up. HMI-Advanced sftware / cmmissining tl frm 7.6 and higher is required t cmmissin the drive. Functins t measure i and n using Starter and HMI Advanced cannt be used in parallel. If Starter measurements are required, this requires a pwer OFF=>ON and then measurements must be immediately made using Starter. Measurements perfrmed with Starter must nt be preceded with measurements perfrmed using HMI-Advanced. If a SINAMICS cmpnent is replaced r upgraded, then the firmware release must be checked and if required, brught t the riginal release status. (Key wrd: Macr ) The firmware releases can be checked in the fllwing parameters: Cntrl Unit R18 Firmware release f the CU Infeed R128 Firmware release f the infeed Drive MD R128 Firmware release f the pwer unit R148 Firmware release f the sensr mdule Initially, Starter is still required t determine the mtr cde. Line supply vltages: In rder that the system perates smthly in the final destinatin cuntry, the fllwing parameters must be set in the specified sequence P010 = 1 P210 = Rated line supply vltage f the cuntry in which the equipment is t be perated P211 = Rated line supply frequency f the cuntry in which the equipment is t be perated P340 = 1 Siemens AG 2012 I DT MC R&D 51 Page 10 f 41

11 P3410 = 4 P3900 = 3 Save RAM t ROM Pwer-dwn the system, nly pwer-up again when it is actually cnnected t the line supply in the cuntry in which the equipment is t be finally used. A line supply identificatin is perfrmed with the next ON cmmand at the ALM - and the values determined saved s that they are nt lst if the line supply fails. The APC functin increases the NCU lad. The impact n perfrmance shuld be estimated befre it is used. p1240, p1244, p1248, p1250: If, in SW V2.4, VDC cntrl and DDS changever were activated, then after an upgrade, the cntents f the indices >0 frm p1240 shuld be checked t ensure that they have the crrect value. Drive clck cycles f 62.5 µs have been released with 840D sl and SW 2.5 SP1. The fllwing cnditins then apply: - tw axes can be perated with this setting n a CU r NX. - nly the same clck cycles can be set n a duble-axis mdule Fr SINUMERIK sftware releases 1.3 and 1.4/2.4, different firmware versins f the cmpnents invlved in the safety functins (NCU, NX, Mtr Mdules, DRIVE-CLiQ mtrs) can be mixed withut having t adapt the firmware versins. Frm SINUMERIK sftware release 1.5/2.5 and higher, the fllwing applies: The firmware versins f the Mtr Mdules, Sensr Mdules and DRIVE-CLiQ mtrs invlved in the safety functins (these include integrated Sensr Mdules) must be adapted t the SINAMICS firmware versin f the NCU. This is realized autmatically when bting if parameter p9826 (firmware, autmatic) is set t 1 (standard setting). When Safety Integrated is used, parameter p9826 (firmware, autmatic) must be set t 1 and must nt be re-parameterized. Fr a Safety Integrated acceptance test, the safety firmware versins f all f the Mtr Mdules, Sensr Mdules and DRIVE-CLiQ mtrs invlved in the safety functins must be read-ut, lgged and checked against the fllwing list: Every line in the tables represents a permissible cmbinatin f the safety firmware versins. The maximum drive system utilizatin f the CU r NX must nt exceed 80% (the utilizatin level is displayed in parameter 9976[xx]). The NCU lad level as a result f the psitin cntrller and interplatr shuld nt exceed 60% in the reset state. The actual lad can be checked under Diagnsis / System resurces. Cam utput (psitin switching cycles) fr mdul rtary axes is nt pssible in a time windw < 4 IPO clck cycles. The MPPs and MCPs PN are perated in the Ethernet mde at the 840D sl. Switch psitins 9 and 10 simultaneusly "n" (PN mde) is nt permissible. The machine data t describe the spindle dynamics must be set s that they apprximately crrespnd t the actual dynamics f the spindle. f the values are unnecessarily increased, then alarms can ccur at the transitin frm spindle peratin t psitining peratin. NCU 7xx.2 PN: It is nt pssible t access Prfinet PLC I/O frm the NCK via system variables. NCU 7xx.2 PN: Prfinet interfaces 1 and 2 (upper tw) are available. The "Parking axis" functin with an SMI encder is nt pssible withut pwer ff/n. Alarm 7300: If NC archives frm sftware releases < NCK are used, Alarm 7300 is utput if MD18235=0. MD18235=20000 is the standard setting. The functin "Apprach fixed stp G75" is nt permissible fr active radius cmpensatin G41 / G42 (Alarm 14091, Index 9). During fixed-pint apprach with G75, the fixed pint is apprached with nn-linear interplatin (RTLIOF). As a result, the axis are traversed with the set jerk fr the psitining axes ($MA_JOG_AND_POS_MAX_JERK). Machine data 11295[0..9] nw cnfigures the memry. When a change is made, this is nt signaled by an alarm. Values deviating frm the standard must be remved in existing archives befre making the upgrade. Alarm 8025: Advanced Surface 6FC5800-0AS07-0YB0 is an ptin and is interlcked using an ptin data. Siemens AG 2012 I DT MC R&D 51 Page 11 f 41

12 If yu wish t use the X127 service interface with a PG/PC fr an NCU7x0.2 with SW 2.6, then it has t be nted that the netwrk interface f the PG/PC perates in the "DHCP client" mde - i.e. the "IP address is autmatically allcated". If the netwrk interface f the PG/PC has been set t a fixed IP ( xx), then althugh a ping ges t X127, neither with Step7 nr with an HMI is it pssible t g nline. The firewall is activated as the default setting. STEP 7 hardware cnfiguratin Sinumerik NCU 7xx.2 PN: The different versins V2.4 / V2.6 / V2.7 in the hardware catalg refer t the apprpriate PLC perating system f the PLC 319. The PLC perating system is part f the NCU sftware and thus depends n the NCU sftware versin. The perating system included in the sftware versin can be checked in the diagnstic screen (Diagnsis / Versin / PLC / Details). As a cnsequence, the NCU must be selected in the STEP 7 hardware cnfiguratin. Example: The NCU Sftware Versin 2.6 HF2 cmprises a PLC perating system 319-3PN/DP Versin xx. Therefre, a NCU 7xx.2 PN (V2.7) must be selected in the hardware cnfiguratin. The Sftware Versin 2.6 SP1 requires the PLC Tlbx V The NCU Link has nt been released in cmbinatin with safety axes. The behavir f the NCK with regard t the dynamic ffset values ACC, ACCLIMA, VELOLIM, VELOLIMA, JERKLIM, JERKLIMA has changed. The machine data descriptin shws the individual effect. Archives with MD = false are incmpatible. The machine data (hmi_functin_mask) must always be set. The machine data must be increased when defining mre than tw channels. Archives with 18150=150 (standard) may be incmpatible. Archives with MD > 0 are incmpatible. With MD32250 > 0, speed setpint r trque setpint standardizatin is n lnger transferred frm the drive. The interface signal "Invert M3/M4" nw als acts when tapping with G331/G332. In applicatins in which the interface signal is always set t "1", the spindle is nw rtated in the incrrect directin with G331/G332. T achieve a behavir that is cmpatible with earlier versins, the bit 22 in MD35035 must be set t "1" (the standard default is 0). Archives with MD28253=100 (ld default value) may be incmpatible. Change the MD int 200 (new default). Archives with MD19730[0] =0 are incmpatible. Sftkeys are missing in MDA. Change the MD int 804hex. Due t an implementatin errr, Spline Interplatin culd be released withut a license alarm. If this feature has been used, yu require a new license key. S far, the gear stage 1 culd be preset with 0 and 1 in the DB[axis].DBB16. Nw, a gear stage change is always requested when specifying 0 in the data byte 16. Upn acknwledgement f the gear stage change with "0", the Alarm "Actual gear stage des nt crrespnd t the setpint gear stage" is utput. It may be necessary t adapt the user PLC prgram. The functin TANGON with additinal parameter "P" has nt been released. Remedy: Use the standard setting "S". The Siemens cycles are laded upn each startup frm the CF card t the CPU. This behavir can be switched ff / n by using the service cmmands sc disable s_cycles / sc enable s_cycles and perfrming a subsequent general NC reset. The cntents f the Siemens GUD variables (SGUD) have been relcated in PGUD. T be able t lad archives cmprising SGUD, these must be prcessed. Otherwise, the cntents f the SGUD and PGUD variables may be prvided twice. Grinding technlgy: The new functin "Calculate grinding wheel peripheral speed in diameter" has nt been released due t AP The SD43235 has a speed imit f 10,000 rpm as default value. When upgrading t sftware versin NCK r later and spindle speeds exceeding 10,000 rpm, the SD43235 must be increased t the crrespnding value. The speed is limited by SD43235 if the system variable $AC_SMAXVELO_INFO[n] has the value 21. Multitl as manual tl: With repeated selectin (f tls within this manual multitl), in the sequence Siemens AG 2012 I DT MC R&D 51 Page 12 f 41

13 T="x" M06 --> T0 M06 --> T="Y" M06 --> T0 M06, the identifier manual tl is nt set upn the secnd tl selectin. As a result, the system tries t stre the multitl in the magazine with the next T0 M06. When lading the tplgy frm a Sinumerik 840D sl with NCU730.2 PN (0AA2) int an empty Starter prject, errrs ccur during uplading. The nline access t the CU_INT functins prperly. If the SINAMICS crashes after reading in a.tgz archive cmprising user data during startup, delete the file /user/sinamics/data/del4bt.txt. Operating the prgram NC_ARC_UPDATE System requirement: Windws XP with SP2 r SP3 Area f validity: This tl allws t prcess NC archives which have been created with SINUMERIK 840D sl, SW 2.5 r later, befre reading them in in SW 2.6 SP1. The definitins f data blck SGUD.DEF are adapted t the new Sftware Versin 2.6 SP1 r later. Functin: The prgram NC_ARC_UPDATE remves GUD variables frm NC archives, which are included in the files SGUD.DEF and PGUD.DEF. Operatin: 1. Cpy the file NC_ARC_UPDATE.exe int a directry n the drive C:. 2. Duble-click n NC_ARC_UPDATE.exe. Fig. 1: Start screen 3. Actuate the Next sftkey. Siemens AG 2012 I DT MC R&D 51 Page 13 f 41

14 Fig. 2: Drive and directry selectin fr riginal archive 4. Actuate the Next sftkey. Fig. 3: Display f the NC archives which can be cnverted. Siemens AG 2012 I DT MC R&D 51 Page 14 f 41

15 5. Press the buttn Arrw dwn resp. use the muse t select the archive. The selected NC archive is highlighted in blue. Fig. 4: Archive selectin 6. Actuate the sftkey Accept area:. Fig. 5: Archive selected Siemens AG 2012 I DT MC R&D 51 Page 15 f 41

16 7. Actuate the Next sftkey Fig. 6: Step display 1st step 8. Actuate the Next sftkey Fig. 7: Step prcessing Siemens AG 2012 I DT MC R&D 51 Page 16 f 41

17 9. Actuate the Start sftkey. Fig. 8: Start the 1st step 10. Actuate the OK sftkey. The selected NC archive is prcessed and a new archive called Update.arc is generated. Update.arc is stred in the same directry as the riginal archive. Fig. 9: End f prgram Siemens AG 2012 I DT MC R&D 51 Page 17 f 41

18 Machine data change as a result f the changed Drive ES SlaveOM Drive ES SlaveOM is respnsible fr allcating addresses f the drive units at the Prfibus f the PLC. Addresses are allcated in the PLC HW Cnfig. The addresses allcated here must be entered int the NC machine data MD13050[nn] and when safety is active they must be entered int MD10393[nn] - crrespnding t the axis cnfiguratin required. When Starter frm V4.1.n and higher is installed (later, als with the installatin f Tlbx V2.6), the "new" Drive ES SlaveOM is linked in. Nw - fr each CU r NX - an address space is reserved fr 6 axes - this is different than previusly. This ccurs when newly generating r adapting a PLC hardware cnfiguratin. As a result, under certain circumstances, addresses can shift r gaps can ccur. This mdified address distributin must then be cmmunicated t the NC in machine data 13050[nn] and when safety is active, in MD10393[nn] as therwise, the axis assignments are n lnger crrect. This is especially the case if yu are wrking with the existing NC data backups. The reasn fr this is that they n lnger match the PLC hardware cnfiguratin. Further, in HW Cnfig, the address f telegram 390 (PZD-2/2) f the first NX changes frm 6516 t When using additinal NC mdules, the address is incremented with an ffset f 10. Machine data MD13120[1+n] must be apprpriately adapted. If existing PLC prjects are imprted int an S7 envirnment with "new" Drive ES SlaveOM, then the ld address cnfiguratins are kept. Hwever, drive bjects that have been newly inserted in this prject have the new address allcatin. A standard "new" address allcatin is achieved using "rerganized addresses". If, fr NX bjects frm an existing cnfiguratin, "Standard telegram 1 (PZD-2/2)" is entered, then this must be replaced by telegram 390 in rder t achieve a standard, new address allcatin. Example: An NCU is cnfigured with a Sinamics Integrated and tw NX10 each with 3 axes. Address distributin with the "ld" versin f Drive ES SlaveOM: On the NX10_1, the 3rd axis has address 4420 On the NX10_2, the 1st axis has address 4460 Address distributin with the "new" versin f Drive ES SlaveOM: On the NX10_1, the 3rd axis has address 4420 On the NX10_2, the 1st axis has address 4580 Tip: When re-cnfiguring existing cnfiguratins, in rder that a cmplete change ver is made t the new addressing, a start shuld be made at the lwest slave number t initiate the address allcatin using the key "addresses". All f the slaves have been allcated new addresses, if the nte "N change" is utput fr each slave when initiating the address allcatin. Siemens AG 2012 I DT MC R&D 51 Page 18 f 41

19 "Old" versin f Drive ES SlaveOM Siemens AG 2012 I DT MC R&D 51 Page 19 f 41

20 PLC HW cnfiguring Siemens AG 2012 I DT MC R&D 51 Page 20 f 41

21 NX10_1 Siemens AG 2012 I DT MC R&D 51 Page 21 f 41

22 NX10_2 Siemens AG 2012 I DT MC R&D 51 Page 22 f 41

23 "New" versin f Drive ES SlaveOM Siemens AG 2012 I DT MC R&D 51 Page 23 f 41

24 NX10_1 Siemens AG 2012 I DT MC R&D 51 Page 24 f 41

25 NX10_2 Siemens AG 2012 I DT MC R&D 51 Page 25 f 41

26 Machine data 13050[nn] Siemens AG 2012 I DT MC R&D 51 Page 26 f 41

27 Rerganizing addresses 4. Functinal imprvements and further develpments f NCK as cmpared t V2.6 SP1 (NCK ) 5. SINUMERIK Operate Functinal extensins in SINUMERIK Operate 2.6 SP1 HF1 as cmpared t 2.6 SP1 Display f user icns in the large header f the Machine area User icns can be displayed in the secnd header line f the machine peratr area. In this case, the prgram name is displayed in the right field f the third header line. Active stp cnditins verlay the prgram name display. The user icn display is cntrlled via PLC bits. 32 bits are available fr this. 16 psitins are prvided t display the user icns in the header. The icns must be prvided as PNG files and stred in the file system (/user/hmi/ic/ic640, etc) fr the specific reslutin. The user icns are cnfigured in the sectin [UserIcns] f the file slmahdcnfig.ini. The fllwing must be stated: - The basic address f the PLC duble wrd including the bits required t cntrl the icn display and - fr each bit used, the file name f the user icn and the psitin where the user icns shall be displayed. Example: [UserIcns] USER_ICON_BASE=DB19.DBB80 ; set the start byte f the plc duble wrd that displays the icns ; (DB19.DBD80) Siemens AG 2012 I DT MC R&D 51 Page 27 f 41

28 UI_0 = icn1.png,4 UI_1 = icn2.png,6 ; shw icn1.png n psitin 4 if bit 0 (DB19.DBX83.0) is set ; shw icn2.png n psitin 6 if bit 1 (DB19.DBX83.1) is set 5.1 Functinal extensins in SINUMERIK Operate 2.6 SP1 HF3 as cmpared t 2.6 SP1 Drive reset: With immediate effect, a warm restart f the drive can n lnger be perfrmed, that means, the sftkeys Reset Extended Reset / Drive Device and Drive System have been remved. Stre setup data: _TMZ is autmatically appended t the name suggested fr the backup file. Simulatin: The htkey Crtl+ M allws t switch ver the simulatin speed between the speed currently set via verride and the maximally pssible speed. Make the fllwing cnfiguratin setting in the file slsimcnfigsettings befre activating this htkey: Parameter displayptinmask/overrideoverdrive 0 = N verdrive 1 = is deleted upn leaving the simulatin 2 = will be retained beynd leaving Ntes regarding SINUMERIK Operate: The SINUMERIK Operate 2.6 SP1 sftware is autmatically started as a cmpnent f the CNC sftware 2.6 when NCU 7x0 is started. SINUMERIK Operate is als called "internal SINUMERIK Operate" (cntrary t the "external SINUMERIK Operate" n the PCU 50.3). The internal SINUMERIK Operate can nly be perated frm an peratr panel with TCU (e.g. OP 012+TCU, HT 8,...) which is cnnected at X120 f NCU 7x0 using Ethernet. Operatr cntrl via PC/PG using the VNC viewer is pssible. The cnfiguratin data such as e.g. PLC message and alarm texts must be saved n the CF card f the NCU in the crrespnding directries under /card/user/sinumerik/hmi/... r /card/em/sinumerik/hmi/... (refer t the cmmissining instructins HMI sl). The file system n the CF card can nly be accessed "nline", i.e. nly when the NCU is running. Data can be transferred using a USB stick r netwrk cnnectin via the SINUMERIK Operate peratr interface (Cmmissining / System data area) r using a netwrk cnnectin and the RCS Cmmander tl r WinSCP. IMPORTANT: Names f cnfiguratin files must always be written in lwer case letters. When upgrading frm CNC-SW 2.4, under certain circumstances, display MD values must be manually cnverted (frm the hmi_md.ini file) int the crrespnding new NC-MD. Refer t HMI sl cmmissining instructins, sectin 9.1 fr the cnversin table. Fr string part prgrams and archives n the CF card ("lcal drive"), ptin 6FC5800-0AP12-0YB0 "additinal HMI user memry n CF card" is required. Ntice: Fr a general NCK reset, the ptin is als deleted and as a cnsequence, the "lcal drive" is n lnger available until the ptin is set again. Existing data is kept. When perating an NCU withut TCU (i.e. nly with HMI Advanced r HMI sl n PCU 50.3), the internal HMI sl must be deactivated. This is realized using a service cmmand "sc disable hmi". Operatr interface sftware HMI-Advanced 7.6 SP1 r the cmmissining tl 7.6 SP1 is required t cmmissin the drive. Only 1 SINUMERIK Operate may be active at 1 NCU - either the internal SINUMERIK Operate r 1 external HMI-Advanced r 1 SINUMERIK Operate fr PCU 50.3 / PC. Exceptins: Cmmissining / service; HMI-Advanced fr the main peratr statin with permanently assigned MCP and 1 tl lading statin with SINUMERIK Operate withut MCP. After changing the NC cnfiguratin r reading-in r dwnlading an NC series cmmissining archive, then an explicit data alignment may be necessary fr the simulatin. This is initiated in the cmmissining / HMI area using the "Simulatin Pwer On" sftkey n the 2nd vertical sftkey bar. Optin 6FC5800-0AP22-0YB0 simultaneus recrding: The prgram runtime display can be activated using MD $MC_PROCESSTIMER_MODE. Ladable cmpile cycles are nt backed up using NC series cmmissining archive because they are saved n the CF card f the NCU and are kept fr a general NC reset. They can be handled the same as HMI cnfiguratin data. The use f upper case/lwer case letters when specifying paths in SELECT instructins f jb lists, which refer t the part prgrams n the CF card r USB stick, is relevant and must be strictly bserved. Siemens AG 2012 I DT MC R&D 51 Page 28 f 41

29 Handling special characters in the editr: Text files can be edited using the SINUMERIK Operate Editr if the text files use the LF character (0aH) r the character string CRLF (0d0aH) as line r end f blck identifier. The editr cannt pen binary files. Files with the fllwing extensins.exe,.lib,.elf,.arc,.ts,.zip,.so,.png,.bmp,.ico,.cfs,.bin,.qm,.hmi,.cfg,.acx,.emf,.alm,.ard,.tgz,.pte,.cyc can neither be pened. Files that are newly generated frm the SINUMERIK Operate Editr are UTF-8-cded - and have the LF characters as end f blck identifier. Fr UTF-8-cded files, all special characters are crrectly displayed. When pening files, the SINUMERIK Operate Editr assumes that the files are UTF-8-cded. If files with anther cding are pened, e.g. with Windws page cding, then the special characters are nly crrectly displayed if the SINUMERIK Operate was changed ver t the apprpriate system language. This als invlves e.g. files that were generated using the HMI-Advanced Editr. When pening with the SINUMERIK Operate Editr, the cding f such files is nt changed. There is n autmatic cnversin int UTF-8-cding. If files were generated r prcessed with an external editr (e.g. Ntepad under Windws) and nt the SINUMERIK Operate Editr, then it shuld be nted that the file is saved, UTF-8-cded. When using Ntepad, and when saving the file as encding select "UTF-8" in the Save As dialg bx. If special characters are nt being used, then "ANSI" can als be specified as encding. Fr the V24 data transfer, the V24 mdule 6FC5312-0FA01-0AA0 must be integrated int the NCU. The functin is activated in HMI in the file /em/sinumerik/hmi/cfg/slpmcnfig.ini with the entry [V24] userv24 = true A template fr this file is prvided under /siemens/sinumerik/hmi/template/cfg. The V24 sftkeys are prvided in the PrgramManager under "Archive". The V24 baudrate is limited t max "Operatin withut SINUMERIK OP" ptin: The screen size (reslutin) fr the external Viewer cannt be set at present. 6. Infrmatin regarding the NCU base sftware: The Linux perating system f the NCU 7x0 is als knwn as the NCU base sftware, analg t the base sftware fr the PCU The assciated dcumentatin is prvided n the DVD supplied in IM7. When bting, the NCU base sftware ensures that the NC, PLC and HMI sftware start - and if it is being used - that the TCU is als bted. The NCU base sftware is user-rientated, i.e. yu must lgn with a lgin and passwrd and yu are then allcated certain access rights. Presently, this is nly relevant fr the access t a Linux service shell r fr access t the CF card using RCS cmmander r WinSCP. Fr cmmissining and service, the "manufact" lgin is used tgether with the passwrd "SUNRISE" (bserve upper and lwer case letters!). The Linux service shell is entered at the TCU by simultaneusly pressing the "Area changever" and "Recall" keys (F10 and F9), fllwed by "Scan fr Servers", "2" r by bting the NCU service system frm the USB stick. After bting the NCU 7x0 frm a USB stick with the NCU service system, the "manufact" lgin and "SUNRISE" passwrd must als be entered assuming that the CF card cntains CNC sftware that can run. If this is nt the case (e.g. if the CF card is empty), then in this case, the lgin is "admin" fllwed by "SUNRISE" as passwrd. Using the cmmand "sc help", in this service shell yu btain a list f the syntax f all f the available service cmmands Netwrking: Please bserve the current dcumentatin "Operatr cmpnents and netwrking (IM5) Versin 03/2010"! All f the settings regarding netwrking and TCU cnfiguratin can als be perfrmed using the "System Netwrk Center"; this is available n the PCU 50.3 as well as n the NCU. Imprtant system and netwrk settings f the NCU base sftware are present in the basesys.ini file in the directry /card/user/system/etc. - and can be changed there. The riginal basesys.ini is lcated under /card/siemens/system/etc with the name "template-basesys.ini". Every NCU in the plant r system netwrk shuld be allcated a unique ("infrmative") cmputer name with the entry "Hst name=..." in basesys.ini. Upper case/lwer case letters, numbers and minus symbl characters are permitted. Siemens AG 2012 I DT MC R&D 51 Page 29 f 41

30 The DHCP server f the NCU shuld always be switched n. When changing IP addresses f NCUs / PCUs, the service cmmand "sc clear dhcp" shuld be run in rder that the change becmes effective Cnfiguratin f ne NCU with TCUs and MCPs With this cnfiguratin, principally, there are n special settings required in basesys.ini. DHCP server and internal HMI-sl remain switched n Cnfiguratin f ne NCU with ne PCU 50.3, MCPs and where applicable TCUs With this cnfiguratin, the fllwing settings are required in the basesys.ini f the NCU: Hst name =... SyncMdeDHCPD_SysNet = ON_MASTER Generally, the internal HMI-sl shuld be switched ff because perating tw HMIs (HMI-Advanced and Operate) n ne NCU is nly permissible in special cases. We recmmend that PCU 50.3 base sftware frm V8.6 SP1 and higher is used n the PCU If there is a TCU (HT8) in the system that is t be switched as standard t the PCU 50.3, then the fllwing entries MaxHstIndex = 1 [hst_1] Address = <IP address f the PCU> must be entered n the NCU in the file/card/user/cmmn/tcu/<tcu-nama>/cmmn/tcu/cnfig.ini Cnfiguratin f several NCUs and where applicable 1 r several PCUs, TCUs, MCPs With this cnfiguratin, the fllwing settings are required in the basesys.ini f the NCU: unique hst name =... fr each NCU unique InternalIP=... same InternalNetMask=... precisely ne NCU with SyncMdeDHCPD_SysNet = ON_MASTER When first bting after netwrking, the DHCP master shuld first bt and then the ther statins. PCU base sftware frm V8.6 SP1 and higher is required n the PCU The default cnfiguratin "Cmplete TCUsupprt" shuld be kept in the System Netwrk Center, tab TCU supprt. "Sync mde lw pririty" is recmmended under the tab DHCP-Settings. All peratr statins in the plant/system netwrk (TCUs, HT8, PCU 50) are managed n the NCU with "ON_MASTER", i.e. the cnfig.ini files - relevant during the runtime - and als the.leases file with all f the IP addresses allcated in the system are lcated there. The cnfig.ini files are distributed t all ther NCUs / PCUs frm the master NCU with the service cmmand "sc distribute tcudata". With the service cmmand "sc clear dhcp" fllwed by pwering dwn/pwering-up the cmplete system, the NCUs / PCUs are allcated, their specified IP addresses and these are re-allcated fr the TCUs and MCPs; the.leases file is then distributed t all ther NCUs / PCUs. Imprtant: With the System Netwrk Center, tab OPs, the cnfig.ini files f all peratr statins can be directly edited n the master NCU n each PCU The data is autmatically distributed t all NCUs / PCUs with each change. 7. Cycle packages: In the CNC Sftware Versin 2.6 SP1, the fllwing cycle packages are included n the CF card: Cycles (technlgical cycles) Measuring cycles ISO cycles ShpMill cycles ShpTurn cycles Siemens AG 2012 I DT MC R&D 51 Page 30 f 41

s SINUMERIK 840D sl

s SINUMERIK 840D sl s SINUMERIK 840D sl 2010-08-10 CNC Sftware 2.6 SP1 HF2 SINUMERIK 840D sl, CNC system sftware 6 axes ) 6FC5850-1XG21-0YA0 with HMI-sl, 6 languages, n CF Card; with license ) Exprt 6FC5850-1YG21-0YA0 SINUMERIK

More information

s SINUMERIK 840D sl

s SINUMERIK 840D sl s SINUMERIK 840D sl 2011-12-19 CNC Sftware 2.7 SP1 HF6 SINUMERIK 840DE SL CNC SOFTWARE 6-3 WITH SINUMERIK OPERATE 6 LANGUAGES (EN,DE,FR,IT,SP,CHS); EXPORT SOFTWARE 2.7 SP1 HF6 ON CF CARD WITH LICENSE 6FC5850-1YG23-1YA0

More information

s SINUMERIK 840D sl

s SINUMERIK 840D sl s SINUMERIK 840D sl 2013-05-29 CNC Sftware 2.7 SP3 HF10 Installatin and perating ntes The CNC Sftware 2.7 SP3 HF10 can be perated n SINUMERIK NCUs 7x0.2 with MLBF...-_AA2 and NCUs 7x0.3. The CNC Sftware

More information

s SINUMERIK 840D sl

s SINUMERIK 840D sl s SINUMERIK 840D sl 2010-10-20 CNC Sftware 2.4 SP3 with HMI sl SINUMERIK 840D sl, CNC system sftware fr 6 axes ) 6FC5850-1XG21-2YA0 with HMI sl, in six languages, n CF card; with license ) Exprt 6FC5850-1YG21-2YA0

More information

s SINUMERIK 840D sl

s SINUMERIK 840D sl s SINUMERIK 840D sl 2010-07-13 CNC System Sftware 2.5 SP3 SINUMERIK 840D sl, NCU system sftware fr 6 axes ) 6FC5850-1XG21-1YA0 with HMI sl, in 6 languages, n CF card; with license ) Exprt 6FC5850-1YG21-1YA0

More information

DIVAR IP 3000 Field Installation Guide

DIVAR IP 3000 Field Installation Guide CCTV IP Netwrk Vide Technical Brief DIVAR IP 3000 Field Installatin Guide 1 DIVAR IP 3000 Field Installatin Guide Overview The purpse f this guide is t prvide the step-by-step prcess f installing a DIVAR

More information

s SINUMERIK 840D sl

s SINUMERIK 840D sl s SINUMERIK 840D sl 2009-10-22 ShpTurn 1.5 SP2 SINUMERIK 840D sl, CNC SOFTWARE 6-3 ) 6FC5842-1XG11-0YA0 with ShpTurn HMI, in 6 languages (EN,DE,FR,IT,SP,V-CH), n CF card; with license ) Exprt 6FC5842-1YG11-0YA0

More information

These tasks can now be performed by a special program called FTP clients.

These tasks can now be performed by a special program called FTP clients. FTP Cmmander FAQ: Intrductin FTP (File Transfer Prtcl) was first used in Unix systems a lng time ag t cpy and mve shared files. With the develpment f the Internet, FTP became widely used t uplad and dwnlad

More information

s SINUMERIK 840D sl

s SINUMERIK 840D sl s SINUMERIK 840D sl 2009-10-22 ShpMill 1.5 SP2 SINUMERIK 840D sl, CNC SOFTWARE 6-3 ) 6FC5841-1XG11-0YA0 with ShpMill, in 6 languages (EN,DE,FR,IT,SP,V-CH), n CF card; with license ) Exprt 6FC5841-1YG11-0YA0

More information

Adverse Action Letters

Adverse Action Letters Adverse Actin Letters Setup and Usage Instructins The FRS Adverse Actin Letter mdule was designed t prvide yu with a very elabrate and sphisticated slutin t help autmate and handle all f yur Adverse Actin

More information

s SINUMERIK 840D sl

s SINUMERIK 840D sl s SINUMERIK 840D sl, NCU system sftware fr 6 axes ) 6FC5841-1XG10-6YA0 with ShpMill, in 6 languages, n CF card; with license ) Exprt 6FC5841-1YG10-6YA0 SINUMERIK 840D sl, NCU system sftware, fr 31 axes

More information

1 Getting and Extracting the Upgrader

1 Getting and Extracting the Upgrader Hughes BGAN-X 9211 Upgrader User Guide (Mac) Rev 1.2 (6-Jul-17) This dcument explains hw t use the Hughes BGAN Upgrader prgram fr the 9211 User Terminal using a Mac Nte: Mac OS X Versin 10.4 r newer is

More information

1 Getting and Extracting the Upgrader

1 Getting and Extracting the Upgrader Hughes BGAN-X 9202 Upgrader User Guide (Mac) Rev 1.0 (23-Feb-12) This dcument explains hw t use the Hughes BGAN Upgrader prgram fr the 9202 User Terminal using a Mac Nte: Mac OS X Versin 10.4 r newer is

More information

HW4 Software version 3. Device Manager and Data Logging LOG-RC Series Data Loggers

HW4 Software version 3. Device Manager and Data Logging LOG-RC Series Data Loggers Page 1 f 18 HW4 Sftware versin 3 Device Manager and Data Lgging LOG-RC Series Data Lggers 2011; Page 2 f 18 Table f cntents 1 ORGANIZATION OF THE HW4 MANUALS... 3 2 OVERVIEW... 4 3 INITIAL SETUP... 4 3.1

More information

s SINUMERIK 840D sl

s SINUMERIK 840D sl s SINUMERIK 840D sl 2008-07-23 NCU System Sftware 2.5 HF2 SINUMERIK 840D sl, NCU system sftware fr 6 axes ) 6FC5850-1XG20-3YA0 with HMI sl, in 6 languages, n CF card; with license ) Exprt 6FC5850-1YG20-3YA0

More information

Campuses that access the SFS nvision Windows-based client need to allow outbound traffic to:

Campuses that access the SFS nvision Windows-based client need to allow outbound traffic to: Summary This dcument is a guide intended t guide yu thrugh the prcess f installing and cnfiguring PepleTls 8.55.27 (r current versin) via Windws Remte Applicatin (App). Remte App allws the end user t run

More information

Release Notes. Dell SonicWALL Security firmware is supported on the following appliances: Dell SonicWALL Security 200

Release Notes. Dell SonicWALL  Security firmware is supported on the following appliances: Dell SonicWALL  Security 200 Release Ntes Email Security Dell SnicWALL Email Security 8.0.1 SnicOS Cntents System Cmpatibility... 1 Enhancements in Email Security 8.0.1... 2 Reslved Issues... 3 Upgrading t Email Security 8.0.1...

More information

Quick Start Guide. Basic Concepts. DemoPad Designer - Quick Start Guide

Quick Start Guide. Basic Concepts. DemoPad Designer - Quick Start Guide Quick Start Guide This guide will explain the prcess f installing & using the DemPad Designer sftware fr PC, which allws yu t create a custmised Graphical User Interface (GUI) fr an iphne / ipad & embed

More information

Xilinx Answer Xilinx PCI Express DMA Drivers and Software Guide

Xilinx Answer Xilinx PCI Express DMA Drivers and Software Guide Xilinx Answer 65444 Xilinx PCI Express DMA Drivers and Sftware Guide Imprtant Nte: This dwnladable PDF f an Answer Recrd is prvided t enhance its usability and readability. It is imprtant t nte that Answer

More information

s SINUMERIK 840D sl

s SINUMERIK 840D sl s Installatin and Operating Ntes SINUMERIK 840DE SL CNC SOFTWARE 31-3 WITH SINUMERIK OPERATE 6 LANGUAGES (EN,DE,FR,IT,SP,CHS); EXPORT SOFTWARE 4.4 SP2 SINUMERIK 840D SL CNC SOFTWARE 31-3 WITH SINUMERIK

More information

1 Getting and Extracting the Upgrader

1 Getting and Extracting the Upgrader Hughes BGAN-X 9202 Upgrader User Guide (PC) Rev 1.0 (23-Feb-12) This dcument explains hw t use the Hughes BGAN-X Upgrader prgram fr the 9202 User Terminal using a PC. 1 Getting and Extracting the Upgrader

More information

I. Introduction: About Firmware Files, Naming, Versions, and Formats

I. Introduction: About Firmware Files, Naming, Versions, and Formats Updating Yur CTOG 250 Cmtech Traffic Optimizatin Gateway Firmware I. Intrductin: Abut Firmware Files, Naming, Versins, and Frmats The CTOG 250 Cmtech Traffic Optimizatin Gateway and its CDM 800 Gateway

More information

Firmware Upgrade Wizard v A Technical Guide

Firmware Upgrade Wizard v A Technical Guide Firmware Upgrade Wizard v4.1.1 A Technical Guide Nvember 2015 Intrductin The Firmware Upgrade Wizard prvides the fllwing features: It supprts upgrading the firmware n designated devices, see Supprted devices.

More information

Custodial Integrator. Release Notes. Version 3.11 (TLM)

Custodial Integrator. Release Notes. Version 3.11 (TLM) Custdial Integratr Release Ntes Versin 3.11 (TLM) 2018 Mrningstar. All Rights Reserved. Custdial Integratr Prduct Versin: V3.11.001 Dcument Versin: 020 Dcument Issue Date: December 14, 2018 Technical Supprt:

More information

Proper Document Usage and Document Distribution. TIP! How to Use the Guide. Managing the News Page

Proper Document Usage and Document Distribution. TIP! How to Use the Guide. Managing the News Page Managing the News Page TABLE OF CONTENTS: The News Page Key Infrmatin Area fr Members... 2 Newsletter Articles... 3 Adding Newsletter as Individual Articles... 3 Adding a Newsletter Created Externally...

More information

s SINUMERIK 840D sl

s SINUMERIK 840D sl s SINUMERIK 840D sl 2013-2-19 CNC Sftware with HMI-Embedded 1.4 SP3 HF1 SINUMERIK 840D sl, CNC system sftware 6 axes ) 6FC5840-1XG11-2YA0 with HMI Embedded, 6 languages, n CF Card; with license ) Exprt

More information

The screenshots/advice are based on upgrading Controller 10.1 RTM to 10.1 IF6 on Win2003

The screenshots/advice are based on upgrading Controller 10.1 RTM to 10.1 IF6 on Win2003 Overview The screenshts/advice are based n upgrading Cntrller 10.1 RTM t 10.1 IF6 n Win2003 Other Interim Fix (IF) upgrades are likely t be similar, but the authr cannt guarantee that the dcumentatin is

More information

Arius 3.0. Release Notes and Installation Instructions. Milliman, Inc Peachtree Road, NE Suite 1900 Atlanta, GA USA

Arius 3.0. Release Notes and Installation Instructions. Milliman, Inc Peachtree Road, NE Suite 1900 Atlanta, GA USA Release Ntes and Installatin Instructins Milliman, Inc. 3424 Peachtree Rad, NE Suite 1900 Atlanta, GA 30326 USA Tel +1 800 404 2276 Fax +1 404 237 6984 actuarialsftware.cm 1. Release ntes Release 3.0 adds

More information

HW4 Software Version 3.4.1

HW4 Software Version 3.4.1 Release ntes HW4 Sftware Versin 3.4.1 Change cntrl HW4 versin 3.4.1 includes all the functins and features f HW4 versin 3.4.0 with the fllwing mdificatins and additins: Enhancements: Nne New features Nne

More information

I. Introduction: About Firmware Files, Naming, Versions, and Formats

I. Introduction: About Firmware Files, Naming, Versions, and Formats I. Intrductin: Abut Firmware Files, Naming, Versins, and Frmats The UT-4500-A Series Upcnverters and DT-4500-A Series Dwncnverters stre their firmware in flash memry, which allws the system t uplad firmware

More information

USO RESTRITO. SNMP Agent. Functional Description and Specifications Version: 1.1 March 20, 2015

USO RESTRITO. SNMP Agent. Functional Description and Specifications Version: 1.1 March 20, 2015 Functinal Descriptin and Specificatins Versin: 1.1 March 20, 2015 SNMP Agent Simple Netwrk Management Prtcl Optin S fr IE and PM Mdules Supplement t Functinal Descriptin and Specificatins f RUB Ethernet

More information

Manual for installation and usage of the module Secure-Connect

Manual for installation and usage of the module Secure-Connect Mdule Secure-Cnnect Manual fr installatin and usage f the mdule Secure-Cnnect Page 1 / 1 5 Table f Cntents 1)Cntents f the package...3 2)Features f the mdule...4 3)Installatin f the mdule...5 Step 1: Installatin

More information

3 AXIS STAGE CONTROLLER

3 AXIS STAGE CONTROLLER CORTEX CONTROLLERS 50, St Stephen s Pl. Cambridge CB3 0JE Telephne +44(0)1223 368000 Fax +44(0)1223 462800 http://www.crtexcntrllers.cm sales@crtexcntrllers.cm 3 AXIS STAGE CONTROLLER Instructin Manual

More information

INSTALLING CCRQINVOICE

INSTALLING CCRQINVOICE INSTALLING CCRQINVOICE Thank yu fr selecting CCRQInvice. This dcument prvides a quick review f hw t install CCRQInvice. Detailed instructins can be fund in the prgram manual. While this may seem like a

More information

USER MANUAL. RoomWizard Administrative Console

USER MANUAL. RoomWizard Administrative Console USER MANUAL RmWizard Administrative Cnsle Cntents Welcme... 3 Administer yur RmWizards frm ne lcatin... 3 Abut This Manual... 4 Setup f the Administrative Cnsle... 4 Installatin... 4 The Cnsle Windw...

More information

Max 8/16 and T1/E1 Gateway, Version FAQs

Max 8/16 and T1/E1 Gateway, Version FAQs Frequently Asked Questins Max 8/16 and T1/E1 Gateway, Versin 1.5.10 FAQs The FAQs have been categrized int the fllwing tpics: Calling Calling Cmpatibility Cnfiguratin Faxing Functinality Glssary Q. When

More information

Gemini Intercom Quick Start Guide

Gemini Intercom Quick Start Guide Gemini Intercm Quick Start Guide 2 Quick Start Guide Cntents Cntents... 1 Overview... 3 First Step unpack and inspect... 3 Netwrk plan and IP addresses... 4 Management PC... 5 Install Sftware... 6 Cnfigure

More information

Microsoft Excel Extensions for Enterprise Architect

Microsoft Excel Extensions for Enterprise Architect Excel Extensins User Guide Micrsft Excel Extensins fr Enterprise Architect Micrsft Excel Extensins fr Enterprise Architect... 1 Disclaimer... 2 Dependencies... 2 Overview... 2 Installatin... 4 Verifying

More information

Element Creator for Enterprise Architect

Element Creator for Enterprise Architect Element Creatr User Guide Element Creatr fr Enterprise Architect Element Creatr fr Enterprise Architect... 1 Disclaimer... 2 Dependencies... 2 Overview... 2 Limitatins... 3 Installatin... 4 Verifying the

More information

s SINUMERIK 840D sl

s SINUMERIK 840D sl s SINUMERIK 840D sl 2014-10-28 CNC Sftware 4.4 SP4 HF2 Installatin and Operating Ntes The CNC Sftware 4.4 SP4 HF2 (internal versin 04.04.04.02.002) cmprises the fllwing cmpnents: Cmpnent Versin NCK (incl

More information

Please contact technical support if you have questions about the directory that your organization uses for user management.

Please contact technical support if you have questions about the directory that your organization uses for user management. Overview ACTIVE DATA CALENDAR LDAP/AD IMPLEMENTATION GUIDE Active Data Calendar allws fr the use f single authenticatin fr users lgging int the administrative area f the applicatin thrugh LDAP/AD. LDAP

More information

Wave IP 4.5. CRMLink Desktop User Guide

Wave IP 4.5. CRMLink Desktop User Guide Wave IP 4.5 CRMLink Desktp User Guide 2015 by Vertical Cmmunicatins, Inc. All rights reserved. Vertical Cmmunicatins and the Vertical Cmmunicatins lg and cmbinatins theref and Vertical ViewPint, Wave Cntact

More information

Contents: Module. Objectives. Lesson 1: Lesson 2: appropriately. As benefit of good. with almost any planning. it places on the.

Contents: Module. Objectives. Lesson 1: Lesson 2: appropriately. As benefit of good. with almost any planning. it places on the. 1 f 22 26/09/2016 15:58 Mdule Cnsideratins Cntents: Lessn 1: Lessn 2: Mdule Befre yu start with almst any planning. apprpriately. As benefit f gd T appreciate architecture. it places n the understanding

More information

SINUMERIK 840D sl NCU Software with HMI Embedded 1.3 SP3

SINUMERIK 840D sl NCU Software with HMI Embedded 1.3 SP3 NCU Sftware with HMI Embedded 1.3 SP3 SINUMERIK 840D sl, NCU System Sftware fr six axes ) 6FC5840-1XG10-3YA0 with HMI Embedded, in 6 languages, n CF card; with license ) Exprt 6FC5840-1YG10-3YA0 SINUMERIK

More information

ES93x INCA Add-On V1.4.0

ES93x INCA Add-On V1.4.0 ES93x INCA Add-On V1.4.0 Page 1 f 9 Cpyright The data in this dcument may nt be altered r amended withut special ntificatin frm ETAS GmbH. ETAS GmbH undertakes n further bligatin in relatin t this dcument.

More information

Procurement Contract Portal. User Guide

Procurement Contract Portal. User Guide Prcurement Cntract Prtal User Guide Cntents Intrductin...2 Access the Prtal...2 Hme Page...2 End User My Cntracts...2 Buttns, Icns, and the Actin Bar...3 Create a New Cntract Request...5 Requester Infrmatin...5

More information

Upgrading Kaltura MediaSpace TM Enterprise 1.0 to Kaltura MediaSpace TM Enterprise 2.0

Upgrading Kaltura MediaSpace TM Enterprise 1.0 to Kaltura MediaSpace TM Enterprise 2.0 Upgrading Kaltura MediaSpace TM Enterprise 1.0 t Kaltura MediaSpace TM Enterprise 2.0 Assumptins: The existing cde was checked ut f: svn+ssh://mediaspace@kelev.kaltura.cm/usr/lcal/kalsurce/prjects/m ediaspace/scial/branches/production/website/.

More information

Getting started. Roles of the Wireless Palette and the Access Point Setup Utilities

Getting started. Roles of the Wireless Palette and the Access Point Setup Utilities Getting started The Wireless Palette is a sftware applicatin fr mnitring the cmmunicatin status between the Wireless LAN PC Card and the Wireless LAN Access Pint (hereinafter referred t as the Access Pint).

More information

VMware EVO:RAIL Customer Release Notes

VMware EVO:RAIL Customer Release Notes VMware EVO:RAIL Custmer Release Ntes EVO:RAIL Release 1.2.0 Dcument Revisin: 1.2.0-2 (May 27, 2015) Cpyright 1998-2015 VMware, Inc. All rights reserved. Cpyright, trademark, and patent infrmatin: http://pubs.vmware.cm/cpyright-trademark.html.

More information

Re-Flashing Your CDM-760 Advanced High-Speed Trunking Modem

Re-Flashing Your CDM-760 Advanced High-Speed Trunking Modem Re-Flashing Yur CDM-760 Advanced High-Speed Trunking Mdem I. Intrductin: Firmware Files, Naming, Versins, and Frmats Make sure t perate the CDM-760 with its latest available firmware. Befre attempting

More information

Avocent Power Management Distribution Unit (PM PDU) Release Notes Firmware Version April 18, 2011

Avocent Power Management Distribution Unit (PM PDU) Release Notes Firmware Version April 18, 2011 Avcent Pwer Management Distributin Unit (PM PDU) Release Ntes Firmware Versin 2.0.1.8 April 18, 2011 This dcument utlines: 1. Update Instructins 2. Appliance Firmware Versin Infrmatin 3. Features/Enhancements

More information

New Product Release Package 8 XT[2] System and Software 19 Jan 2009

New Product Release Package 8 XT[2] System and Software 19 Jan 2009 New Prduct Release Package 8 XT[2] System and Sftware 19 Jan 2009 1.1 NEW OPERATIONAL FEATURES IN MULTICAM 8... 1 1.2 NEW HARDWARE FEATURES... 6 1.3 NEW SYSTEM FEATURES... 6 1.4 BUG FIXES UP TO 08.04.33...

More information

HPE AppPulse Mobile. Software Version: 2.1. IT Operations Management Integration Guide

HPE AppPulse Mobile. Software Version: 2.1. IT Operations Management Integration Guide HPE AppPulse Mbile Sftware Versin: 2.1 IT Operatins Management Integratin Guide Dcument Release Date: Nvember 2015 Cntents Overview: The IT Operatins Management Integratin 3 System Requirements 3 Hw t

More information

User Guide. Avigilon Control Center Mobile Version 2.2 for Android

User Guide. Avigilon Control Center Mobile Version 2.2 for Android User Guide Avigiln Cntrl Center Mbile Versin 2.2 fr Andrid 2011-2015, Avigiln Crpratin. All rights reserved. Unless expressly granted in writing, n license is granted with respect t any cpyright, industrial

More information

ClassFlow Administrator User Guide

ClassFlow Administrator User Guide ClassFlw Administratr User Guide ClassFlw User Engagement Team April 2017 www.classflw.cm 1 Cntents Overview... 3 User Management... 3 Manual Entry via the User Management Page... 4 Creating Individual

More information

Reference Guide. Service Pack 3 Cumulative Update 2. Revision J Issued October DocAve 6: Control Panel

Reference Guide. Service Pack 3 Cumulative Update 2. Revision J Issued October DocAve 6: Control Panel DcAve 6 Cntrl Panel Reference Guide Service Pack 3 Cumulative Update 2 Revisin J Issued Octber 2013 DcAve 6: Cntrl Panel 1 Table f Cntents Abut Cntrl Panel... 6 Submitting Dcumentatin Feedback t AvePint...

More information

Using CppSim to Generate Neural Network Modules in Simulink using the simulink_neural_net_gen command

Using CppSim to Generate Neural Network Modules in Simulink using the simulink_neural_net_gen command Using CppSim t Generate Neural Netwrk Mdules in Simulink using the simulink_neural_net_gen cmmand Michael H. Perrtt http://www.cppsim.cm June 24, 2008 Cpyright 2008 by Michael H. Perrtt All rights reserved.

More information

softpanel generic installation and operation instructions for nanobox products

softpanel generic installation and operation instructions for nanobox products 1 f 10 System Requirements... 3 Installatin... 3 Java... 3 RxTx Serial Drivers... 3 Granting a user permissin t pen a COM Prt in Mac OS X... 3 USB t Serial Drivers... 4 Mac OS X 10.6 Snw Lepard... 4 Operatin...

More information

STIDistrict AL Rollover Procedures

STIDistrict AL Rollover Procedures 2009-2010 STIDistrict AL Rllver Prcedures General Infrmatin abut STIDistrict Rllver IMPORTANT NOTE! Rllver shuld be perfrmed between June 25 and July 25 2010. During this perid, the STIState applicatin

More information

Avigilon Control Center Server User Guide. Version 6.4

Avigilon Control Center Server User Guide. Version 6.4 Avigiln Cntrl Center Server User Guide Versin 6.4 2006-2017, Avigiln Crpratin. All rights reserved. AVIGILON, the AVIGILON lg, AVIGILON CONTROL CENTER, ACC, and TRUSTED SECURITY SOLUTIONS.AVIGILON, the

More information

s SINUMERIK 840D sl

s SINUMERIK 840D sl s SINUMERIK 840D sl 2016-02-15 CNC Sftware 4.5 SP6 Installatin and Operating Ntes The CNC Sftware 4.5 SP6 (internal versin 04.05.06.00.010) cmprises the fllwing cmpnents: Cmpnent NCK SNCK SINAMICS PLC

More information

Enabling Your Personal Web Page on the SacLink

Enabling Your Personal Web Page on the SacLink 53 Enabling Yur Persnal Web Page n the SacLink *Yu need t enable yur persnal web page nly ONCE. It will be available t yu until yu graduate frm CSUS. T enable yur Persnal Web Page, fllw the steps given

More information

IT Essentials (ITE v6.0) Chapter 5 Exam Answers 100% 2016

IT Essentials (ITE v6.0) Chapter 5 Exam Answers 100% 2016 IT Essentials (ITE v6.0) Chapter 5 Exam Answers 100% 2016 1. What are tw functins f an perating system? (Chse tw.) cntrlling hardware access managing applicatins text prcessing flw chart editing prgram

More information

TN How to configure servers to use Optimise2 (ERO) when using Oracle

TN How to configure servers to use Optimise2 (ERO) when using Oracle TN 1498843- Hw t cnfigure servers t use Optimise2 (ERO) when using Oracle Overview Enhanced Reprting Optimisatin (als knwn as ERO and Optimise2 ) is a feature f Cntrller which is t speed up certain types

More information

Avigilon Control Center Virtual Matrix User Guide. Version 6.8

Avigilon Control Center Virtual Matrix User Guide. Version 6.8 Avigiln Cntrl Center Virtual Matrix User Guide Versin 6.8 2006-2018, Avigiln Crpratin. All rights reserved. AVIGILON, the AVIGILON lg, AVIGILON CONTROL CENTER, ACC, and TRUSTED SECURITY SOLUTIONS. are

More information

Integrating QuickBooks with TimePro

Integrating QuickBooks with TimePro Integrating QuickBks with TimePr With TimePr s QuickBks Integratin Mdule, yu can imprt and exprt data between TimePr and QuickBks. Imprting Data frm QuickBks The TimePr QuickBks Imprt Facility allws data

More information

Trimble Survey GNSS Firmware Version 4.81 (July 2013)

Trimble Survey GNSS Firmware Version 4.81 (July 2013) Handheld Integrated Mdular RELEASE NOTES TRIMBLE SURVEY GNSS FIRMWARE Trimble Survey GNSS Firmware Versin 4.81 (July 2013) Requirements This firmware versin includes imprvements t the Survey Receiver firmware.

More information

CCNA 1 Chapter v5.1 Answers 100%

CCNA 1 Chapter v5.1 Answers 100% CCNA 1 Chapter 6 2016 v5.1 Answers 100% 1. Which characteristic f the netwrk layer in the OSI mdel allws carrying packets fr multiple types f cmmunicatins amng many hsts? the de-encapsulatin f headers

More information

Oracle Universal Records Management Oracle Universal Records Manager Adapter for Documentum Installation Guide

Oracle Universal Records Management Oracle Universal Records Manager Adapter for Documentum Installation Guide Oracle Universal Recrds Management Oracle Universal Recrds Manager Adapter fr Dcumentum Installatin Guide December 2009 Universal Recrds Manager Adapter fr Dcumentum Installatin Guide, Cpyright 2009, Oracle.

More information

Element Creator for Enterprise Architect

Element Creator for Enterprise Architect Element Creatr User Guide Element Creatr fr Enterprise Architect Element Creatr fr Enterprise Architect... 1 Disclaimer... 2 Dependencies... 2 Overview... 2 Limitatins... 3 Installatin... 4 Verifying the

More information

DocAve 6 Service Pack 2 Control Panel

DocAve 6 Service Pack 2 Control Panel DcAve 6 Service Pack 2 Cntrl Panel Reference Guide Revisin D Issued February 2013 DcAve 6: Cntrl Panel 1 Table f Cntents Abut Cntrl Panel... 6 Submitting Dcumentatin Feedback t AvePint... 6 Befre Yu Begin...

More information

Quick Installation Guide

Quick Installation Guide Oracle Strategic Operatinal Planning Release 3.5.1 Quick Installatin Guide Quick Installatin Guide This file cntains the fllwing sectins: Purpse... 1 System Requirements... 1 Server Cnfiguratin... 1 Client

More information

Refreshing Axiom TEST with a Current Copy of Production Axiom EPM June 20, 2014

Refreshing Axiom TEST with a Current Copy of Production Axiom EPM June 20, 2014 Refreshing Axim TEST with a Current Cpy f Prductin Axim EPM June 20, 2014 Refreshing Axim TEST If yu maintain an Axim TEST envirnment yu will want t refresh it with a current cpy f yur PROD database when

More information

OO Shell for Authoring (OOSHA) User Guide

OO Shell for Authoring (OOSHA) User Guide Operatins Orchestratin Sftware Versin: 10.70 Windws and Linux Operating Systems OO Shell fr Authring (OOSHA) User Guide Dcument Release Date: Nvember 2016 Sftware Release Date: Nvember 2016 Legal Ntices

More information

NiceLabel LMS. Installation Guide for Single Server Deployment. Rev-1702 NiceLabel

NiceLabel LMS. Installation Guide for Single Server Deployment. Rev-1702 NiceLabel NiceLabel LMS Installatin Guide fr Single Server Deplyment Rev-1702 NiceLabel 2017. www.nicelabel.cm 1 Cntents 1 Cntents 2 2 Architecture 3 2.1 Server Cmpnents and Rles 3 2.2 Client Cmpnents 3 3 Prerequisites

More information

August 22, 2006 IPRO Tech Client Services Tip of the Day. Concordance and IPRO Camera Button / Backwards DB Link Setup

August 22, 2006 IPRO Tech Client Services Tip of the Day. Concordance and IPRO Camera Button / Backwards DB Link Setup Cncrdance and IPRO Camera Buttn / Backwards DB Link Setup When linking Cncrdance and IPRO, yu will need t update the DDEIVIEW.CPL file t establish the camera buttn. Setting up the camera buttn feature

More information

TRAINING GUIDE. Overview of Lucity Spatial

TRAINING GUIDE. Overview of Lucity Spatial TRAINING GUIDE Overview f Lucity Spatial Overview f Lucity Spatial In this sessin, we ll cver the key cmpnents f Lucity Spatial. Table f Cntents Lucity Spatial... 2 Requirements... 2 Setup... 3 Assign

More information

RISKMAN REFERENCE GUIDE TO USER MANAGEMENT (Non-Network Logins)

RISKMAN REFERENCE GUIDE TO USER MANAGEMENT (Non-Network Logins) Intrductin This reference guide is aimed at managers wh will be respnsible fr managing users within RiskMan where RiskMan is nt cnfigured t use netwrk lgins. This guide is used in cnjunctin with the respective

More information

Launching Xacta 360 Marketplace AMI Guide June 2017

Launching Xacta 360 Marketplace AMI Guide June 2017 Launching Xacta 360 Marketplace AMI Guide June 2017 Tels Crpratin 2017. All rights reserved. U.S. patents Ns. 6,901,346; 6,980,927; 6,983,221; 6,993,448; and 7,380,270. Xacta is a registered trademark

More information

Avigilon Control Center Server User Guide. Version 6.8

Avigilon Control Center Server User Guide. Version 6.8 Avigiln Cntrl Center Server User Guide Versin 6.8 2006-2018, Avigiln Crpratin. All rights reserved. AVIGILON, the AVIGILON lg, AVIGILON CONTROL CENTER, ACC, and TRUSTED SECURITY SOLUTIONS.AVIGILON, the

More information

Getting Started with the SDAccel Environment on Nimbix Cloud

Getting Started with the SDAccel Environment on Nimbix Cloud Getting Started with the SDAccel Envirnment n Nimbix Clud Revisin Histry The fllwing table shws the revisin histry fr this dcument. Date Versin Changes 09/17/2018 201809 Updated figures thrughut Updated

More information

Tips For Customising Configuration Wizards

Tips For Customising Configuration Wizards Tips Fr Custmising Cnfiguratin Wizards ver 2010-06-22 Cntents Overview... 2 Requirements... 2 Applicatins... 2 WinSCP and Putty... 2 Adding A Service T An Existing Wizard... 3 Gal... 3 Backup Original

More information

KNX integration for Project Designer

KNX integration for Project Designer KNX integratin fr Prject Designer Intrductin With this KNX integratin t Prject Designer it is pssible t cntrl KNX devices like n/ff, dimming, blinds, scene cntrl etc. This implementatin is intended fr

More information

CaseWare Working Papers. Data Store user guide

CaseWare Working Papers. Data Store user guide CaseWare Wrking Papers Data Stre user guide Index 1. What is a Data Stre?... 3 1.1. When using a Data Stre, the fllwing features are available:... 3 1.1.1.1. Integratin with Windws Active Directry... 3

More information

Date: October User guide. Integration through ONVIF driver. Partner Self-test. Prepared By: Devices & Integrations Team, Milestone Systems

Date: October User guide. Integration through ONVIF driver. Partner Self-test. Prepared By: Devices & Integrations Team, Milestone Systems Date: Octber 2018 User guide Integratin thrugh ONVIF driver. Prepared By: Devices & Integratins Team, Milestne Systems 2 Welcme t the User Guide fr Online Test Tl The aim f this dcument is t prvide guidance

More information

EView/400i Management Pack for Systems Center Operations Manager (SCOM)

EView/400i Management Pack for Systems Center Operations Manager (SCOM) EView/400i Management Pack fr Systems Center Operatins Manager (SCOM) Cncepts Guide Versin 7.0 July 2015 1 Legal Ntices Warranty EView Technlgy makes n warranty f any kind with regard t this manual, including,

More information

Dear Milestone Customer,

Dear Milestone Customer, Dear Milestne Custmer, With the purchase f Milestne Xprtect Transact yu have chsen a very flexible ptin t yur Milestne Xprtect Business slutin. Milestne Xprtect Transact enables yu t stre a serial data

More information

Upgrade Guide. Medtech Evolution General Practice. Version 1.9 Build (March 2018)

Upgrade Guide. Medtech Evolution General Practice. Version 1.9 Build (March 2018) Upgrade Guide Medtech Evlutin General Practice Versin 1.9 Build 1.9.0.312 (March 2018) These instructins cntain imprtant infrmatin fr all Medtech Evlutin users and IT Supprt persnnel. We suggest that these

More information

Laboratory Exercise 3 Using the PIC18

Laboratory Exercise 3 Using the PIC18 Labratry Exercise 3 Using the PIC18 Until this pint, the user has prgrammed the FPGA Interface Bard using the FTDI and has nt been intrduced t the n bard PIC18F2550 micrcntrller. The purpse f this experiment

More information

RxAXIS Security Module 09/25/2013

RxAXIS Security Module 09/25/2013 RxAXIS Security Mdule 09/25/2013 Lessn Title Intrductin: Security Mdule In this tutrial we are ging t lk at the Security Maintenance Mdule f the RxAXIS system. When used, this system gives emplyees access

More information

Proficy* SmartSignal 6.1 Installation Guide

Proficy* SmartSignal 6.1 Installation Guide Prficy* SmartSignal 6.1 IG_P-SS_6.1 R0 Prficy* SmartSignal 6.1 Disclaimer f Warranties and Liability The infrmatin cntained in this manual is believed t be accurate and reliable. Hwever, GE Intelligent

More information

DocAve 6 Control Panel

DocAve 6 Control Panel DcAve 6 Cntrl Panel DcAve 6 Cntrl Panel Reference Guide Reference Guide Service Pack 4, Cumulative Update 3 Revisin T Service Pack 4, Cumulative Update 3 Issued Nvember 2014 Revisin S Issued September

More information

INSERTING MEDIA AND OBJECTS

INSERTING MEDIA AND OBJECTS INSERTING MEDIA AND OBJECTS This sectin describes hw t insert media and bjects using the RS Stre Website Editr. Basic Insert features gruped n the tlbar. LINKS The Link feature f the Editr is a pwerful

More information

WorldShip PRE-INSTALLATION INSTRUCTIONS: INSTALLATION INSTRUCTIONS: Window (if available) Install on a Single or Workgroup Workstation

WorldShip PRE-INSTALLATION INSTRUCTIONS: INSTALLATION INSTRUCTIONS: Window (if available) Install on a Single or Workgroup Workstation PRE-INSTALLATION INSTRUCTIONS: This dcument discusses using the WrldShip DVD t install WrldShip. Yu can als install WrldShip frm the Web. G t the fllwing Web page and click the apprpriate dwnlad link:

More information

Enterprise Installation

Enterprise Installation Enterprise Installatin Mnnit Crpratin Versin 3.6.0.0 Cntents Prerequisites... 3 Web Server... 3 SQL Server... 3 Installatin... 4 Activatin Key... 4 Dwnlad... 4 Cnfiguratin Wizard... 4 Activatin... 4 Create

More information

Frequently Asked Questions

Frequently Asked Questions Frequently Asked Questins Date f Last Update: FAQ SatView 0001 SatView is nt pening and hangs at the initial start-up splash screen This is mst likely an issue with ne f the dependency, SQL LcalDB, missing

More information

REFWORKS: STEP-BY-STEP HURST LIBRARY NORTHWEST UNIVERSITY

REFWORKS: STEP-BY-STEP HURST LIBRARY NORTHWEST UNIVERSITY REFWORKS: STEP-BY-STEP HURST LIBRARY NORTHWEST UNIVERSITY Accessing RefWrks Access RefWrks frm a link in the Bibligraphy/Citatin sectin f the Hurst Library web page (http://library.nrthwestu.edu) Create

More information

UiPath Automation. Walkthrough. Walkthrough Calculate Client Security Hash

UiPath Automation. Walkthrough. Walkthrough Calculate Client Security Hash UiPath Autmatin Walkthrugh Walkthrugh Calculate Client Security Hash Walkthrugh Calculate Client Security Hash Start with the REFramewrk template. We start ff with a simple implementatin t demnstrate the

More information

Technical Paper. Installing and Configuring SAS Environment Manager in a SAS Grid Environment with a Shared Configuration Directory

Technical Paper. Installing and Configuring SAS Environment Manager in a SAS Grid Environment with a Shared Configuration Directory Technical Paper Installing and Cnfiguring Envirnment Manager in a Grid Envirnment with a Shared Cnfiguratin Directry Last Mdified: January 2018 Release Infrmatin Cntent Versin: January 2018. Trademarks

More information

Admin Report Kit for Exchange Server

Admin Report Kit for Exchange Server Admin Reprt Kit fr Exchange Server Reprting tl fr Micrsft Exchange Server Prduct Overview Admin Reprt Kit fr Exchange Server (ARKES) is an Exchange Server Management and Reprting slutin that addresses

More information