Section 5a: Schedule of Requirements and Technical Specifications/Scope of Work. Scope of Work

Size: px
Start display at page:

Download "Section 5a: Schedule of Requirements and Technical Specifications/Scope of Work. Scope of Work"

Transcription

1 Section 5a: Schedule of Requirements and Technical Specifications/Scope of Work Scope of Work Name of Project: Supply and Installation of IT Network Infrastructure for the High National Elections Commission (HNEC), Tripoli, Libya Location: Tripoli, Libya Objective: The scope of this assignment includes the design, supply and installation of the following components: Wired and wireless computer network infrastructure Access control equipment Server room infrastructure Surveillance system The Supplier shall install the cabling infrastructure of the building N2 and N3, set up the network endpoints, and set up the HNEC server rooms in a proper manner to meet the operational, security and environmental requirements. HNEC installed the network infrastructure for Building N1 under another contract. However, the selected supplier, under the terms of this contract shall also implement the network interconnectivity between Building N1 and buildings N2 and N3. The Supplier will receive drawings and floor maps of the buildings after signing the contract. The Scope of works shall be read in conjunction with the Bill of Quantities and the drawings. The details specified in the scope of work is based on the estimation provided by the Client (HNEC), and the vendor may seek any clarification required during the site visit. Items and quantities mentioned in the Bill of Quantities should be used for providing quotes, and BoQ shall prevail in case of any discrepancy between the scope of work description and BoQ. The vendor shall provide quotes inclusive of all costs needed to have the item finished: including but not limited to labour, materials, equipment, cabling, pulling, ducting, piping and all required accessories/works, transportation, overhead, and taxes. All materials and equipment shall comply with the specifications and shall be approved by UNDP and Client (HNEC) before and after the installation. When detailed specification, name or model is mentioned, the contractor shall comply with this unless the vendor can find a technically compliant equivalent and get prior approval from UNDP & Client. A tender briefing and site visit will be conducted on 19 February 2019 at 11:00 am (Libya time) to clarify any issues related to this tender and vendors are encouraged to attend the site visit. Any questions and clarifications required should be ed to the UNDP Libya address procurement.ly@undp.org and the deadline for submitting questions and clarifications shall be 5 days before the bid submission deadline. Any questions or queries submitted after this deadline will not be considered or answered. 1

2 Requirements The technical requirements and specifications toward the scope of the work are mentioned below. The supplier shall install and configure all network switches provided by HNEC & UNDP. There is no need to supply network switches for IT data network; however, the supplier shall provide switches as specified in the BoQ for the surveillance network. GENERAL REQUIREMENTS 1. Each jack shall be Single (only data points for tally Center) RJ45 endpoint, which allows plugging either Ethernet cable. Some points are dual Jack and the estimated number of single and dual jacks are mentioned in the price Schedule Form (Form F). 2. The approach of the network must be a hierarchical model with modular topology. 3. The hierarchical model components shall be the access layer, the distribution layer, and the core (backbone) layer. 4. Core layer requirements a. Network design shall support redundant point-to-point L3 interconnections in the core (triangles, not squares) b. Network design shall avoid L2 loops c. Network design shall include at least two L3 core layer switches to support the redundancy d. The switches must interconnect with each other by high-speed channel (more than 1Gb/s bandwidth) or with link aggregation (up to 4 x 1Gb/s) e. The links to the distribution layer switches must be implemented with fibre-optic channels at 1Gb/s bandwidth f. The installation, testing of inter-building and intra-building fibre-optic, and UTP cables must be implemented according to NECA/FOA or ANSI/TIA-568-D/C standard. g. The core layer devices shall locate at the basement of Building N1, in the datacenter. 5. Distribution layer requirements a. Each building must have at least two distribution layer switches for redundancy b. High availability in the distribution layer shall be provided through dual equal-cost paths from the distribution layer switches to each core layer switch and from the access layer switches (of the same building) to each distribution layer switch. c. The design shall have the mechanisms to avoid L2 loops d. The design shall implement default gateway redundancy e. The links from the distribution layer switch to the core layer and the access layer switches must be implemented with 1Gb/s fibre-optic channels f. The distribution layer switches of the same building must interconnect with each other by 1 Gbs/s fibre-optic channels (or with higher channel than 10Gb/s bandwidth if possible) g. The installation and testing of inter-building and intra-building fibre-optic cables must be implemented according to NECA/FOA or ANSI/TIA-568-D/C standard. 6. Access layer requirements a. Each floor of the building must have its access layer switches b. The switches in the access layer shall be connected to two separate distribution layer switches of the same building for redundancy c. Default gateway redundancy using dual connections to redundant systems (distribution layer switches) d. The links from the access layer switch to the distribution layer switches must be implemented with 1Gb/s fibre-optic channels e. The end nodes must be connected to the access layer switches at least with UTP cat Six (6) cables at 1Gb/s bandwidth 2

3 f. The installation, testing of inter-building and intra-building fibre-optic, and UTP cables must be implemented according to NECA/FOA or ANSI/TIA-568-D/C standard. REQUIREMENT 1: WIRED NETWORK This chapter describes the number of nodes per buildings and floors. The number of data points also include cabling for the voice network. The voice network cabling shall be identical to the wired data network cabling, and the required number of voice sockets are included in the total number of network ports specified in this section (798). A. Building N2 Building N2 consists of, ground floor, first and second floors. This building will host the Tally centre. Below table describes the network nodes distribution for the building N2. Table 1.1 Describes the Infrastructure Requirements for the Building (B2), Ground Floor. Office 1 Office 2 Office 3 Office 4 Office 5 Aisle TOTAL A B NUM-PERSON-MAP PC Socket IP PHONE PRINTER Socket CAMERA ACCESS POINT Data IP Projector 1 1 Data port for IPTV 3 3 TOTAL Single Jack 15 Double Jack ACCESS CONTROL NUM-PATCH- 5 PANEL-24 NUM-SWITCH-48 3 Fiber-patch-cord-12 5 CABLE-FIBER 5 Size-Rack-UNIT 36 Table 1.2 Describes the Infrastructure Requirements for the Building (B2), First Floor. Data Intake Entry 1 NUM-OFFICE office 1 office 2 Data Entry2 Clearance Correction Aisle TOTAL office 3 office 4 office 5 office 6 3

4 Table 1.3 Describes the Infrastructure Requirements for the Building (B2), Second Floor. Column1 ARCHIVE AUDIT MGMT MGMT2 Aisle NONE TOTAL & QUALITY NUM-OFFICE office 1 office 2 office 3 office 4 office 5 office 6 NUM-PERSON-MAP PC IP PHONE PRINTER CAMERA ACCESS POINT IP TV TOTAL single jack 25 double Jack ACCESS CONTROL NUM-PERSON-MAP PC IP PHONE PRINTER CAMERA ACCESS POINT Dataport IP Projector Data port for IP Monitor TOTAL single jack 90 double jack ACCESS CONTROL NUM-PATCH-PANEL NUM-SWITCH-48 6 Fiber-patch-cord CABLE-FIBER 12 Size-Rack-UNIT 36 NUM-PATCH-PANEL NUM-SWITCH-48 3 Fiber-patch-cord-12 1 CABLE-FIBER 8 Size-Rack-UNIT 36 4

5 B. Building N3 Building N3 consists of, ground floor, first and second floors. This building hosts the Call centre. Table 1.4 Describes the Infrastructure Requirements for the Building (B3), Ground Floor. Ground Floor TOTAL المقهى Aisle المراقبين التوعية قسم التدريب حجرة الكابينات تسجيل المرشحين office 1 office 2 office 3 office 4 office 5 office 6 office 7 NUM-OFFICE NUM-PERSON- 0 MAP PC Socket IP PHONE PRINTER Socket CAMERA ACCESS POINT IP TV TOTAL Single Jack 8 Double Jack ACCESS CONTROL NUM-PATCH- 4 PANEL-24 NUM-SWITCH-48 2 Fiber-patch-cord CABLE-FIBER 4 Size-Rack-UNIT 36 Table 1.5 Describes the Infrastructure Requirements for the Building (B3), First Floor. OFFICE Aisle NUM-OFFICE NUM-PERSON-MAP 0 0 PC Socket IP PHONE PRINTER Socket CAMERA ACCESS POINT IP TV TOTAL single jack 13 double 5

6 jack ACCESS CONTROL NUM-PATCH-PANEL-24 4 NUM-SWITCH-48 2 Fiber-patch-cord-12 4 CABLE-FIBER 4 Size-Rack-UNIT 36 Table 1.6 Describes the Infrastructure Requirements for the Building (B3), Second Floor. OFFICE Aisle TOTAL NUM-OFFICE NUM-PERSON-MAP 0 0 PC Socket IP PHONE PRINTER Socket CAMERA ACCESS POINT IP TV TOTAL single jack 15 double jack ACCESS CONTROL NUM-PATCH-PANEL-24 5 NUM-SWITCH-48 3 Fiber-patch-cord-12 1 CABLE-FIBER 1 Size-Rack-UNIT 36 C. Gates (Security blocks) Gates include two small rooms in the perimeter of the compound. Table 1.7 Location Network Nodes (Data and Phone) Left Gate 3 Right Gate 3 TV data ports Access control room 8 IP phone voice port 2 REQUIREMENT 2: WIRELESS NETWORK UNDP and HNEC will provide access points, and AP controller and the supplier shall provide additional items such as small steel poles, cables etc. (if required based on the site survey) for the installation, and configure the devices as required by the HNEC. Table 2.1 Wireless Network Quantity 6

7 2.1 Installation and configuration of ACCESS POINT Cisco Aironet 183x series x 20 with Cisco AP controller x 1 1 REQUIREMENT 3: SERVER ROOM - POWER DISTRIBUTION SYSTEMS AND RAISED FLOOR Main electrical distribution panels must have sufficient clearance to enable easy access and repair. The distance between the electrical distribution panel and active ICT equipment should be at least 1 meter unless agreed by UNDP & client due to space constraints. The supplier shall identify an appropriate area for cable penetration after discussing with HNEC. Also, external and internal conduit paths shall be electrically isolated from each other. The supplier shall identify and supply appropriate electrical cables (from the generator to the server room, estimated distance is 150m) and circuit breakers x 2 as recommended by the UPS manufacturer (estimate for 15kv APC UPS is 3pole circuit breakers, and 25 mm * 4, i.e. 4 cables in one copper wire cable, not copper filaments and the cable shall have a rubber buffer between the cables). The vendor shall supply UPS 15Kva X 2pcs with external battery packs. The UPS should support 1+1 configuration, i.e. can be connected in parallel to provide either fail-safe redundancy or increased capacity, coldstart operation, expandable runtime, network management card for remote monitoring/control and external battery pack (Tower with Included Accessories Hot-swappable, replaceable batteries) Server room installation services and items including but not limited to: Table 3.1 Server Room - Power distribution systems and raised floor (building Two (2) floor One (1)) Power cable 4 x 16 mm Power cable 3 x 6 mm circuit breaker 80 A Power cable 25mm*4 from the generator to the server room, 150m est distance (recommended specs, subject to UPS specification) and three (3) pole circuit breakers as required for the UPS 15Kva Power system Installation including UPS and connectivity with all related accessories such as additional power cables from the generator, circuit breakers etc. for 2 x 15Kva UPS Anti-static raised floor for the server room Size 42 sqft est (7.8 X 5.3) raised floor panels raised floor lifting raised floor accessories raised floor installation Rack Power Distribution Unit The supplier shall equip server room with an anti-static raised floor with a load bearing capacity of 4 x 42U racks of 600 Kg each and 2 x 32U racks of 375 Kg each. The Supplier must procure the raised floor and provide information about the cost of the procurement per sq/m. The Supplier shall also provide cost information about the installation of the raised floor in the bid response documents. The cost shall include raised Floor (Sqm) materials & installation with all Accessories. (Installation of the all necessary components for the raised floor, raised floor ramp and cable management systems are the sole responsibility of the vendor. During the installation the contractor should place the panels and cable management trays according to the requirements of HNEC ICT department) 7

8 Raised floor location: Server Room (Building N2) The anti-static raised floor must have the following features: Finished floor system height up to 12 inches. Floor panels with anti-static coverage, such as Static Dissipative Vinyl, High-Pressure Laminates, Aluminum-based fire resistant / noncombustible material or similar Floor Type: Reinforced Bolted Stringer type with under the floor cable & power trays Increased weight bearing abilities up to Heavy Grade or Extra Heavy Grade Systems (by MOB PF2 PS SPU specification) Metal components must have nickel or powder coatings in preference to zinc passivation to mitigate the risk of zinc whiskers. The raised access floor shall be installed in the way to accommodate all the network cables, power cables and fire suppression system paths required. The floor itself must also be hardwearing, anti-static and be able to withstand high temperatures and heavyweights. Detailed list of raised floor panels, additional panel requirements and accessories are listed for easy reference. Table 3.2 S No Type (Picture) Product Name Qty 1 Raised floor Main kit: Antistatic load bearing 12 inches (Square feet) 42 (Est) 2 Perforated Air Flow Panel 4 3 Underfloor fans with air ducts for airflow panel 6 4 Infinity Air Grate for Steel w/levelers or similar 2 5 The PLUGG 5" Circle Grommet or similar 6 6 KoldLok Integral 1010 Unit or similar inch Grommet 3 8

9 8 4" x 4" Cable Guard 4 9 Panel Lifter and Holder Kit 2 10 Ramp Kit Complete (if required based on the design) inch Multi-level cable trays with vertical support for Raised floor 42 Sqm as required REQUIREMENT 4: SERVER ROOM - COOLING SYSTEM The Supplier shall install cooling equipment for the server room. Cooling units can be installed against walls. There must be sufficient clearance to enable easy access and repair. The distance between cooling equipment and active ICT equipment should be at least 1 meter unless agreed by UNDP & client due to space constraints. Table Cooling System 4.1 Cooling system DC room size 7.8 X 5.3 X 3.3 (24000 btu/hr or higher) Installation & Commissioning including Indoor units, pipes and accessories Installation 1 REQUIREMENT 5: SERVER ROOM - FIRE SUPPRESSION SYSTEM For the fire alarm and prevention (against fires class A, B and C) fire suppression system shall be installed by the vendor. The system shall conform to the following technical requirements: The system must work with synthetic/chemical fire suppression gas and extinguishes a fire by removing the free radicals or heat elements from the fire triangle (Oxygen, Heat and Fuel). The manufacturer of the suppression system hardware and detection components shall be ISO 9000 certified Designed for server rooms/datacenters (without negative influence on the servers, network devices, cables, jacks and so on) Waterless, Non-corrosive, No residue and oily deposits, No influence on business continuity, Electrically non-conductive Extinguishes fire through absorption and chemical reaction Discharge no later than 10 seconds The Supplier shall procure all the required equipment to implement the fire suppression system in the server room of Building N2 (1 unit). Table Fire suppression system 9

10 5.1 Fire suppression system DC room size 7.8 X 5.3 X Fire suppression system installation, configuration and training 1 REQUIREMENT 6: SURVEILLANCE SYSTEM The Supplier shall install the surveillance system including the network video recorder, CCTV camera and central management system. Installation of the entire surveillance system network including cabling, pulling, piping, cover ducting and all required accessories and works. Table Surveillance system NVR 128 Channel support 30 days data shall be stored locally in a compressed video 6.1 format (12 months standard equipment warranty) Indoor IP Cam (CCTV) 6.2 Please see FORM F: Price Schedule Form for specifications 6.3 Outdoor IP Cam (CCTV) Please see FORM F: Price Schedule Form for specifications Outdoor PTZ IP Cam (CCTV) 30X 4MP Fibre Cable outdoor OM4 (estimated m) Optical Distribution frame (ODF) 12 port SC Fiber Patch Cords Cables SC to LC Distribution Box outdoor 15U IP 66 or above Network Switch 16 Port + 2SFP ports, POE Inverter 850VA + battery 65A with power stabiliser Fibre cable Splicing, pulling, ducting and installation Surveillance System & network Installation, configuration and Training 1 Total REQUIREMENT 7: ACCESS CONTROL SYSTEM All server rooms, the entrance of the buildings, conference halls, server rooms and IT operation rooms must be equipped with an access control solution with centralised administration and control of sites and all users. The supplier shall supply and install the access control system as specified below: 7 Access control system 7.1 The supplier shall procure all the required items for the implementation of the access control requirements (Paxton NET2 or equivalent (Please see description provided below and FORM F: Price Schedule Form for specifications) 12 10

11 7.2 Installation and configuration and Training 1 Total The supplier shall procure all the required items for the implementation of the access control requirements (recommended Brand Paxton NET2 or equivalent). Key features of the system must conform to the following requirements: Central control of privileges Manage the users and all doors of server rooms Event reporting Integrate other systems - intruder alarm, fire alarm, lighting, CCTV, Notification Proximity, magistrate, keypads and biometric type of readers must be compatible The components must plug directly into the LAN ADDITIONAL INFORMATION UNDP and HNEC will provide some network equipment as mentioned below and subject to the contract; the selected supplier shall procure items listed in the final price schedule form and any additional items required for the completion of the project. 1. Switches and modules (Not required to supply switch for IT network installation. Switches as specified in the price schedule for surveillance system shall be supplied by the vendor) The vendor shall procure all the required equipment and accessories including but not limited: 1. Fire suppression system 2. UPS 3. Cooling equipment 4. Access control equipment 5. Anti-static raised floor 6. Surveillance system equipment including CCTV camera. 7. Cables, dual RJ45 jack, patch panels, ducts and other accessories and equipment required for wired and wireless network installation Project timeline The overall project duration is nine (9) weeks starting from the date of signing the contract. The project shall include the following stages: Table 15 N Project Phases Timeline 1 Preparation and planning stage One (1) week 2 Installation stage Six (6) weeks - (2.1 Building N2 Three (3) weeks) - (2.2 Building N3, Gates, Security rooms Three (3) weeks) 3 Testing, acceptance and training stage Two (2) weeks Total Duration Nine (9) weeks 4 Warranty period Six (6) months The supplier, One (1) week after the signing of the contract shall perform the preliminary assessment of the buildings and present a detailed project implementation plan. Project plan itself shall include the network plan, testing, acceptance plan, and the detailed timeline of installation. Detailed network plan including: Data network endpoints locations in the offices Voice network endpoints locations in the offices 11

12 Intermediate network equipment locations Wi-Fi access points locations Cabling pathways represented on the floor plans Technical specialists from HNEC shall approve the installation plan before starting the installation stage. Overall installation work shall be completed within Six (6) weeks. The supplier shall start the installation from Building N2 and N3, security rooms and gates. During the installation, the Supplier shall provide reports to HNEC after finishing each stage and perform weekly meetings per request of HNEC staff to discuss the installation progress. At the end of the project, the supplier shall perform the testing and acceptance of the network (Two (2) weeks). The testing shall be performed with the presence and close cooperation of the HNEC IT specialists assigned for the management of this project and should be completed within the specified time. The testing shall include all the required tests described in the project implementation plan. With the testing, the supplier shall organise hands-on training for the HNEC staff on the management and maintenance of network infrastructure. After the installation of the network, the Supplier shall provide Six (6) month warranty fixing network faults correction of technical defects and malfunctions identified during the warranty period technical support for IT staff of HNEC Project deliverables During the project, the supplier shall provide the following deliverables Table 16 N Deliverable Description 1 2 Project implementation plan (document) Detailed network design (document) The project implementation plan includes: 1. Project implementation timeline 2. List of required hardware 3. Testing and acceptance plan o Testing strategy o Timing of testing o Test plan 4. Deliverables acceptance objectives and approach 5. Training plan 6. Acceptance Criteria & Activities The project plan shall be delivered at the end of the first stage. The Customer shall approve the project plan. Detailed network plan includes: Network endpoints locations in the offices Phone endpoint locations in the offices Intermediate network equipment locations The detailed location plan of the wireless device and cables. (Wireless coverage areas of access points) Cabling pathways represented on the floor plans Detailed network design shall be delivered at the end of the installation. The Customer shall approve the document. 12

13 3 Implementation of the network according to the design Installation of the network according to the network design document Cabling and labelling Ducting, piping and all required civil works Installation of network/phone endpoints Installation of network devices including access points and switches Installation of the fire prevention system in server rooms Installation of the cooling systems Installation of the raised anti-static floor in server rooms Installation of access control solution Installation of the surveillance system and CCTV camera 5 6 Testing acceptance of the network Training on knowledge transfer Testing organised and delivered in accordance with the test strategy and plan. Training courses delivered as required. 1. Training 1: Training for network technicians. During the training, all the details related to the network architecture and installation details should be provided by the vendor. 2. Training 2: Management of the surveillance system and CCTV camera. 7 Warranty support The Supplier shall deliver Six (6) months warranty service: fixing network faults correction of technical defects and malfunctions technical support for IT staff of HNEC 13

RFP Annex A Terms of Reference UNHCR HQ Data Centre Colocation Service

RFP Annex A Terms of Reference UNHCR HQ Data Centre Colocation Service RFP 2017 845 Annex A Terms of Reference UNHCR HQ Data Centre Colocation Service Version 1 Contents Project objectives... 1 Background... 1 Scope... 1 Timeframe and Cost... 4 Stakeholders, roles and responsibilities...

More information

Tender No: MUST/ 011/

Tender No: MUST/ 011/ MERU UNIVERSITY OF SCIENCE AND TECHNOLOGY NETWORK INFRASTRUCTURE ADDENDUM Tender No: MUST/ 0/207-208. SERVER ROOM The 30 kva UPS SOCOMEC and the 30 KVA AVR SOCOMEC makes should be provided. Concrete sealing

More information

Total Amount Carried Forward To Bill summary Page

Total Amount Carried Forward To Bill summary Page BILL 1: GROUND FLOOR Supply, Deliver, Install, Set to Work and Commission the Following. 1.01 4 Pair, 24 AWG UTP cable, CAT 6, 305 metres per roll. As siemon or equal &approved equivalent 1.02 CAT 6 Face

More information

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120 DESIGN GUIDELINES PRESTO INSTALLATION & CONNECTIVITY PAGE 1 of 4 ELECTRICAL CONNECTIVITY AND WIRING Communications Conduits Conduits designated for Presto equipment data wiring shall be clearly identified

More information

IXcellerate Moscow One Datacentre - Phase 1 & 2 Overview

IXcellerate Moscow One Datacentre - Phase 1 & 2 Overview Contents 1. Document Purpose... 2 2. Facility Overview... 2 2.1 Technical Space... 2 2.2 Load Density... 2 2.3 Resilience... 2 2.4 Engineering Plant Maintenance & Service Restoration... 3 3. Engineering

More information

Subject: Quotation for Setup/Up Gradation of Data Center in Karachi

Subject: Quotation for Setup/Up Gradation of Data Center in Karachi REQUEST FOR QUOTATION (RFQ) FACSIMILE/EMAIL Company/Individual Name: Business address: Telephone Fax Email Subject: Quotation for Setup/Up Gradation of Data Center in Karachi Dear Sir/Madam, On behalf

More information

Tarleton State University. Specifications

Tarleton State University. Specifications Tarleton State University Campus Communication Infrastructure Specifications Cabling Standards Summary This document identifies Tarleton State University communication infrastructure standards. The communication

More information

Open Access. Definitions

Open Access. Definitions Open-IX Data Center Technical Standards Version 2.0, January 1, 2018 Questions: dc-group@open-ix.org The purpose of the Open- IX Data Center Technical Standards document is to establish a recommended standard

More information

brightsolid Data Hall 1 Keysource Technical Specifications

brightsolid Data Hall 1 Keysource Technical Specifications brightsolid Data Hall 1 Keysource Technical Specifications Page 1 Introduction A Data Centre is a highly controlled environment that provides IT to external organisations seeking to outsource their requirements

More information

JT Rue Des Pres DATA CENTRE

JT Rue Des Pres DATA CENTRE JT Rue Des Pres DATA CENTRE Facility Product Description JT s Data Centre Hosting Service provides a secure computer room environment with protected and backup power, security and bandwidth. Data Centre

More information

UNPRICED BID Tender no: INF/ISRF/ELE/91/2018 Name of work : INSTALLATION OF CCTV CAMERAS FOR ISRF PROJECT SITE SL NO DESCRIPTION OF WORK UNIT QTY (A) UNIT RATE SUPPLY (Rs.) Basic Supply Rate/Unit Including

More information

DATA CENTRE. JT First Tower Lane. Facility Product Description. Data Centre Services

DATA CENTRE. JT First Tower Lane. Facility Product Description. Data Centre Services JT First Tower Lane DATA CENTRE Facility Product Description JT s Data Centre Hosting Service provides a secure computer room environment with protected incoming power supplies and a fully resilient network

More information

NZQA registered unit standard version 2 Page 1 of 7. Demonstrate basic knowledge of electronic security data protocols and cabling

NZQA registered unit standard version 2 Page 1 of 7. Demonstrate basic knowledge of electronic security data protocols and cabling Page 1 of 7 Title Demonstrate basic knowledge of electronic security data protocols and cabling Level 3 Credits 15 Purpose This unit standard is for electronic security installers engaged in the installation

More information

TENDER NOTICE NO. A (01)/PSEB/ for Purchase and Installation of Office Equipment s /Items for PSEB, Islamabad Office

TENDER NOTICE NO. A (01)/PSEB/ for Purchase and Installation of Office Equipment s /Items for PSEB, Islamabad Office TENDER NOTICE NO. A ()/PSEB/27-45 for Purchase and Installation of Office Equipment s /Items for PSEB, Office (Guarantee) Limited invites sealed bids from all the eligible reputed manufacturers/suppliers

More information

DATACENTER COLOCATION. Flexible, Secure and Connected

DATACENTER COLOCATION. Flexible, Secure and Connected DATACENTER COLOCATION Flexible, Secure and Connected Flexible Solutions for Your Requirements Contents Your Goals 2 Compound and Buildings 4 Security 6 Infrastructure 8 Free Choice 10 Good Reasons 12 Our

More information

v2.5 was updated May 10, v2.6 is an updated copy from March 1, 2017.

v2.5 was updated May 10, v2.6 is an updated copy from March 1, 2017. Changes in v2.6: v2.5 was updated May 10, 2016. v2.6 is an updated copy from March 1, 2017. Modifications to 4. Horizontal Pathways section with feedback incorporated from UofA Facilities and Operations

More information

Huawei Railway Communication Service Solution Guide

Huawei Railway Communication Service Solution Guide Huawei Railway Communication Service Solution Guide Huawei Technologies Co., Ltd. Keywords Railway transport, service solution, subsystem, design,, solution implementation Abstract Huawei Railway Communication

More information

2 Telecommunications Data Center Facility Requirements

2 Telecommunications Data Center Facility Requirements Generic Requirements for Telecommunications Data Center Equipment and Spaces GR-3160-CORE Table of Contents Table of Contents Generic Requirements Notice of Disclaimer..................... iii Preface...........................................

More information

UNIVERSITY OF CALICUT (Purchase Division)

UNIVERSITY OF CALICUT (Purchase Division) No. 12831/PURCHASE-ASST-A1/2013/CU UNIVERSITY OF CALICUT (Purchase Division) Calicut University. P.O., Dated, 07.06.2013. TENDER NOTICE Sealed and competitive tenders are invited for the installation of

More information

Ultrafast Fibre UFB Services Agreement Service Description for Central Office and POI Co-location Service

Ultrafast Fibre UFB Services Agreement Service Description for Central Office and POI Co-location Service Ultrafast Fibre UFB Services Agreement Service Description for Central Office and POI Co-location Service 1 Interpretation 1.1 The Central Office and POI Co-location Service described in this Service Description

More information

Connectix Specification Guide for Category 6 U/UTP and Optical Fibre Cabling System Architecture

Connectix Specification Guide for Category 6 U/UTP and Optical Fibre Cabling System Architecture Connectix Specification Guide for Category 6 U/UTP and Optical Fibre Cabling System Architecture Issue Document Status Date: Prepared: Checked: 6 Cat 6 U/UTP, Optical Fibre and MER/SER Guidelines 29/03/2018

More information

SPECIFICATION STANDARD COPPER RISER AND INTRABUILDING CABLING

SPECIFICATION STANDARD COPPER RISER AND INTRABUILDING CABLING PART 1: GENERAL 1.01 SCOPE OF WORK A. The Designer and Contractor are responsible to be familiar with the provisions contained herein and with other Sections of this Specification as applicable to the

More information

Governing Standards. All wiring and components shall meet the applicable requirements of the NEC.

Governing Standards. All wiring and components shall meet the applicable requirements of the NEC. 1.1 SCOPE. This section covers the furnishing and installation of Video Surveillance Systems (VSS), including Video Management System (VMS) software, Cameras, and all associated equipment, devices, and

More information

RE Series Rack from Eaton Product Presentation

RE Series Rack from Eaton Product Presentation RE Series Rack from Eaton Product Presentation AUG 2018 Quick Overview What is Eaton s RE Series Rack Platform? RE Series is an amalgamation of the NR & RE Series with many value-add component enhancements;

More information

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO Cabling Standards Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO 1. Purpose CABLING STANDARDS This technical note

More information

DATA CENTRE. JT Five Oaks. Facility Product Description. Data Centre Services

DATA CENTRE. JT Five Oaks. Facility Product Description. Data Centre Services JT Five Oaks DATA CENTRE Facility Product Description JT s Data Centre Hosting Service provides a secure computer room environment with protected and backup power, security and bandwidth. Data Centre specification

More information

TENDER DOCUMENT NATIONAL INSTITUTE OF PUBLIC FINANCE AND POLICY. New Delhi SUPPLY OF LAN EQUIPMENTS AND INSTALLATION OF LAN IN THE CAMPUS

TENDER DOCUMENT NATIONAL INSTITUTE OF PUBLIC FINANCE AND POLICY. New Delhi SUPPLY OF LAN EQUIPMENTS AND INSTALLATION OF LAN IN THE CAMPUS TENDER DOCUMENT SUPPLY OF LAN EQUIPMENTS AND INSTALLATION OF LAN IN THE CAMPUS Issue Of Tender January 10, 2019 onwards Last Date of Submission of Tender- 29.1.2019 Opening of Technical Bid 29.1.2019 3.30

More information

SPI PowerNet requirements for the non-contestable Interface Works at Deer Park Terminal Station

SPI PowerNet requirements for the non-contestable Interface Works at Deer Park Terminal Station SPI PowerNet requirements for the non-contestable Interface Works at Deer Park Terminal Station SPI PowerNet Reference: ZD23 Version: 1.1 Issue date: 15 May 2014 Contents 1 Scope... 3 2 Deer Park Terminal

More information

w w w. s i g n a m a x. c o m Power over Ethernet PoE A P P L I C A T I O N S G U I D E

w w w. s i g n a m a x. c o m Power over Ethernet PoE A P P L I C A T I O N S G U I D E TM w w w. s i g n a m a x. c o m Power over Ethernet PoE A P P L I C A T I O N S G U I D E Your Guide to PoE Table of Contents Your Guide to PoE...1 PoE Background...1 A Brief History...2 PoE Device Types...3

More information

DIT/BPR&BTD/OA/1206/

DIT/BPR&BTD/OA/1206/ UCO BANK Department of Information Technology Request for Proposal (RFP) For Building of Data Centre Infrastructure for non-cbs servers at 6th Floor, HO DIT (Re-tendering) RFP Ref No: DIT/BPR&BTD/OA/1206/2018-19

More information

Ultrafast Fibre UFB Services Agreement Service Description for Central Office and POI Co-location Service

Ultrafast Fibre UFB Services Agreement Service Description for Central Office and POI Co-location Service Ultrafast Fibre UFB s Agreement Description for Central Office and POI Co-location 1 Interpretation 1.1 The Central Office and POI Co-location described in this Description will be available from the date

More information

CENTRAL ELECTRONICS LIMITED Material management division

CENTRAL ELECTRONICS LIMITED Material management division CENTRAL ELECTRONICS LIMITED Material management division Corrigendum-II Dated: 04092018 Sub: Tender titled Rate Contract for Supply, Install, Testing & Commissioning and Warranty of Security System in

More information

f) Telecommunications Equipment Rooms

f) Telecommunications Equipment Rooms SECTION 270000 - COMMUNICATIONS PART 1 - GENERAL 1.1 GENERAL REQUIREMENTS A. The Contractor is held responsible to be familiar with the provisions contained herein and with other Sections of this Specification

More information

Chorus UFB Services Agreement Service Description for Central Office and POI Co-location Service

Chorus UFB Services Agreement Service Description for Central Office and POI Co-location Service Chorus UFB Services Agreement Service Description for Central Office and POI Co-location Service 1 Interpretation 1.1 The Central Office and POI Co-location Service described in this Service Description

More information

Qs & As from CSD RFP pre-submission conference

Qs & As from CSD RFP pre-submission conference Qs & As from CSD RFP 19-503 pre-submission conference Q: Who was there? A: The attendance sheet follows. Q: There are 4 exterior cameras on light poles shown in the prints, are 3 of those 360 cameras and

More information

Table of Contents. 1 Introduction. 2 Facility and Space Planning Requirements

Table of Contents. 1 Introduction. 2 Facility and Space Planning Requirements 1 Introduction 1.1 Purpose and Scope.................................. 1 1 1.2 Telecommunications Service Provider (TSP) Role................ 1 1 1.3 Equipment Manufacturer Role............................

More information

16. PERFORMANCE BANK GUARANTEE

16. PERFORMANCE BANK GUARANTEE 15. PAYMENT TERMS The terms of payment are as under: (i) No advance payment against purchase order. (ii) Mode of payment to Bidder- After completion of supply installation and commissioning the Surveillance

More information

ATTACHMENT - III SCOPE OF WORK

ATTACHMENT - III SCOPE OF WORK ATTACHMENT - III SCOPE OF WORK INTRODUCTION: Mumbai Pune Solapur Pipeline (MPSPL) is one of the HPCL s cross country product pipeline from Mumbai to Solapur. Dedicated optical fiber based telecommunication

More information

Computer Network Design Guide Existing Systems 1 / 6

Computer Network Design Guide Existing Systems 1 / 6 COMPUTER NETWORK DESIGN GUIDELINE FOR EXISTING SYSTEMS DOCUMENT NUMBER: 16765 APPLICATION: ELEMENTARY, MIDDLE AND HIGH SCHOOL DATE OF ISSUE: 11-27-06 - First Issued NOTES: The attached guideline should

More information

SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS

SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS CONTENTS PAGE 1. GENERAL... 5-1 1.1. Introduction... 5-1 1.2. Equipment Layout Requirements... 5-1 2. EQUIPMENT FRAMES... 5-2 2.1. Introduction...

More information

Data Center Consultants for the upcoming IIT Bombay HPC+BYOH Data Center

Data Center Consultants for the upcoming IIT Bombay HPC+BYOH Data Center Data Center Consultants for the upcoming IIT Bombay HPC+BYOH Data Center IIT Bombay Computer Center invites Data Center Consultants to submit their bids for the contract for the design and project management

More information

SPECIFICATIONS FOR IP BASED CCTV SYSTEM CAMERAS

SPECIFICATIONS FOR IP BASED CCTV SYSTEM CAMERAS SPECIFICATIONS FOR IP BASED CCTV SYSTEM SR # DETAILS Quantity CAMERAS 1 3 MEGA PIXEL NETWORK IR CAMERA 10 3 Mega Pixel Full HD Weather Proof Network IR / Night Vision Camera Minimum 3 MP (2048 x 1536)

More information

3M Data Center Solutions. Innovation. is the. Solution

3M Data Center Solutions. Innovation. is the. Solution 3M Data Center Solutions Innovation is the Solution Biometric Physical Security Multi-factor biometric access control reader for data center physical security needs. Air Filtration Filters help provide

More information

Training Offer. Catalogue

Training Offer. Catalogue Training Offer Catalogue docnr. 3.0 rev.date: 04 August 2008 2/13 Introduction, "The transmission quality of a cabling installation depends on the cabling system used, as well as the installation itself."

More information

1.0 Executive Summary

1.0 Executive Summary Statement of Work - 1 - Power and Cooling Assessment for Data Center Professional Services Service 1.0 Executive Summary Table of Contents 1.0 Executive Summary 2.0 Features & Benefits 3.0 Details of Service

More information

Powered Fiber Cable System

Powered Fiber Cable System CommScope Powered Fiber Cable System Template Rev. 3/2/2016 CommScope provides this information as a courtesy to its customers and potential customers. Customers should review the information to ensure

More information

THE CORPORATION OF THE CITY OF STRATFORD

THE CORPORATION OF THE CITY OF STRATFORD THE CORPORATION OF THE CITY OF STRATFORD Tender Number: T16 17 Replacement of Entrance Phone Systems, Addition of CCTV Camera Systems and Wireless Fidelity/Wireless Internet (WIFI) Systems Throughout the

More information

Open IX Data Center Technical Standards

Open IX Data Center Technical Standards Open IX Data Center Technical Standards Comments/Questions: dc group@open ix.org Last updated: November 1, 2013 Version: 1.0 Developed by: Open IX Data Center/MMR Standards Committee Gabe Cole RTE Group

More information

PIONEERS OF The Structured Cabling Systems

PIONEERS OF The Structured Cabling Systems ems t s y gs F n O i l S b EER red Ca N O I P uctu r t S The w w w. n c c - k s a. n e t Network Code Company (Ncc) is one of the Well Known Establishments & Companies Under M/s AlMuhkam Contracting Group

More information

SECTION SPECIAL SYSTEMS. Website and Construction Cameras

SECTION SPECIAL SYSTEMS. Website and Construction Cameras PART 1 GENERAL SECTION 01121 SPECIAL SYSTEMS 1.01 WORK INCLUDED A. Project Construction Site Cameras and Video Streaming Servers B. Project Web site C. Network & Infrastructure D. Internet Connectivity

More information

Site Preparation for ClearCube Installation. Rev. F

Site Preparation for ClearCube Installation. Rev. F Site Preparation for ClearCube Installation Rev. F EXECUTIVE SUMMARY Because of the centralized nature of the ClearCube architecture, installation of the system requires a certain degree of site preparation.

More information

Cabling Infrastructure

Cabling Infrastructure Presented by: Jim McGlynn PE RCDD/LAN Specialist O Neal/Gaj A telecommunications and technology consulting firm that specializes in the hospitality industry. Program Discussion: Goals Technology Definitions

More information

Aironet and WLAN Controller Product Power Options

Aironet and WLAN Controller Product Power Options Aironet and WLAN Controller Product Power Options Document ID: 21480 Contents Introduction Prerequisites Requirements Components Used Conventions Cisco Discovery Protocol Power Options Aironet 350 Series

More information

SECTION FARE COLLECTION SYSTEM

SECTION FARE COLLECTION SYSTEM SECTION 17830 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for the Ticket Vending Machines (TVMs) and for the Clipper Network Card Interface Devices (CIDs) as a subsystem of the station

More information

Power-Over-Ethernet Weatherproof 18" x 16" x 8" Enclosure with Equipment Mounting Plate and Cooling Fans

Power-Over-Ethernet Weatherproof 18 x 16 x 8 Enclosure with Equipment Mounting Plate and Cooling Fans Power-Over-Ethernet Weatherproof 18" x 16" x 8" Equipment Mounting Plate and Cooling Fans Applications and Features Applications: Remote Wireless LAN WiFi equipment installations using Power- Over-Ethernet

More information

Course Description. Audience. Prerequisites. : Course CTDC : Certified TIA-942 Design Consultant. Course Outline :: CTDC ::

Course Description. Audience. Prerequisites. : Course CTDC : Certified TIA-942 Design Consultant. Course Outline :: CTDC :: Module Title Duration : Course CTDC : Certified TIA-942 Design Consultant : 3 days Course Description Data centres are at the core of many organisations. Downtime of the data centre could lead to major

More information

(Data Center Networks & Cloud Computing Security)

(Data Center Networks & Cloud Computing Security) BPSDC (Data Center Networks & Cloud Computing Security) Lecture 3 Data Center Standars Service Level Agreement 2 Building a Data Center is just a Start What is Service Level Agreement (SLA)? An official

More information

RfP No. APSFL/CCTVPMA/231/2016, Dated:

RfP No. APSFL/CCTVPMA/231/2016, Dated: S.No 1 2 3 RfP No. APSFL/CCTVPMA/231/2016, Dated: 30.05.2018 RfP for Selection of Project Monitoring Agency (PMA) for implementation of cloud based IP CCTV Surveillance System in AP Corrigendum 2 Dated:

More information

Ref. No. : MDI/ CCTV Cameras /2017 Date: May,9,2017

Ref. No. : MDI/ CCTV Cameras /2017 Date: May,9,2017 Ref. No. : MDI/ CCTV Cameras /2017 Date: May,9,2017 Dear Sir, Subject: Invitation of Sealed quotations for CCTV Cameras Sealed Quotations are invited CCTV Cameras. As per the scope of work and on the terms

More information

Great Falls Public School Districts 1 & A th Street South Great Falls, MT February 16, 2018

Great Falls Public School Districts 1 & A th Street South Great Falls, MT February 16, 2018 Great Falls Public School Districts 1 & A 1100 4th Street South Great Falls, MT 59405 February 16, 2018 Request for Quote for E-rate Category 2 Equipment SLD Entity Number: 134909 Applicant Form 470 Identifier:

More information

Installation Service. 1.0 Executive Summary. Factory Trained Technician Train Customer Support Staff On Basic Operation Of The Equipment

Installation Service. 1.0 Executive Summary. Factory Trained Technician Train Customer Support Staff On Basic Operation Of The Equipment Installation Service Statement of Work Start-up Service for Cooling Start-up - 1 - Service for Cooling Service 1.0 Executive Summary Table of Contents 1.0 Executive Summary 2.0 Features & Benefits 3.0

More information

IP67 Certified 2T2R 5GHz Outdoor Wireless-N Access Point - PoE-Powered 300Mbps a/n WiFi AP

IP67 Certified 2T2R 5GHz Outdoor Wireless-N Access Point - PoE-Powered 300Mbps a/n WiFi AP IP67 Certified 2T2R 5GHz Outdoor Wireless-N Access Point - PoE-Powered 300Mbps 802.11a/n WiFi AP Product ID: R300WN22MO5E The R300WN22MO5E Outdoor Wireless Access Point lets you add 5GHz Wireless-N network

More information

Network Construction Guide Specification Telecommunications Infrastructure Standards V 2.6

Network Construction Guide Specification Telecommunications Infrastructure Standards V 2.6 Network Construction Guide Specification Telecommunications Infrastructure Standards 11-16-2018 V 2.6 Springfield Public Schools R12 Prepared by: Approved by: Released by: Springfield Public Schools R12

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist TES A. Roads-Service, Lanes Common Items Trails and service roads provide adequate access to buildings for maintenance B. Testing Results-provided to the local government construction representative Data

More information

GOVERNMENT OF KHYBER PAKHTUNKHWA, FINANCE DEPARTMENT TENDER NOTICE

GOVERNMENT OF KHYBER PAKHTUNKHWA, FINANCE DEPARTMENT TENDER NOTICE GOVERNMENT OF KHYBER PAKHTUNKHWA, FINANCE DEPARTMENT TENDER NOTICE Sealed tenders are invited from well reputed firms duly registered with Income Tax and Sales Tax Departments for the supply and installation

More information

Installing the Cisco MDS 9020 Fabric Switch

Installing the Cisco MDS 9020 Fabric Switch CHAPTER 2 This chapter describes how to install the Cisco MDS 9020 Fabric Switch and its components, and it includes the following information: Pre-Installation, page 2-2 Installing the Switch in a Cabinet

More information

PoP ROOM: INSIDE AND OUTSIDE PLANT RULES & REGULATIONS

PoP ROOM: INSIDE AND OUTSIDE PLANT RULES & REGULATIONS PoP ROOM: INSIDE AND OUTSIDE PLANT RULES & REGULATIONS Version 14 November 19, 2014 Digital Realty Table of Contents INTRODUCTION... 3 ACCESS TO THE POP ROOMS, ISP & OSP... 3 PoP- MoP Forms... 3 Who must

More information

(Detailed Terms, Technical Specifications, and Bidding Format) This section describes the main objective to be achieved through this procurement.

(Detailed Terms, Technical Specifications, and Bidding Format) This section describes the main objective to be achieved through this procurement. ITEM:- Supply and Installation of Servers for Private Cloud Annexure Tender No: - 201601945 IIT Bombay is setting up a cloud to host important applications and data for a national project. The cloud is

More information

DATA CENTER CABLING DESIGN FUNDAMENTALS

DATA CENTER CABLING DESIGN FUNDAMENTALS White Paper DATA CENTER CABLING DESIGN FUNDAMENTALS Telecommunications Cabling Infrastructure Requirements according the Availability Classes I-IV of Introduction With the completion by end of Q1 2016,

More information

جامعة العلوم والتكنولوجيا األردنية

جامعة العلوم والتكنولوجيا األردنية جامعة العلوم والتكنولوجيا األردنية دائرة العطاءات المركزية عطاء رقم ( 51 )2015/ شراء أجهزة شبكة فرعية Network Access Switches Page 1 of 6 Section 1: Overview Jordan University of Science and Technology

More information

Creating the Perfect Data Center Environment

Creating the Perfect Data Center Environment Creating the Perfect Data Center Environment A wide range of factory laminated HPL and static dissipative floor coverings are available. The perfect data center environment requires the ability to handle

More information

Business Customer Demarcation Information

Business Customer Demarcation Information Business Customer Demarcation Information The intent of this document is to clearly define Communications terminology and deployment with reference to business data customers and services. 1. What is a

More information

XBR V4 INSTALLATION AND USER GUIDE

XBR V4 INSTALLATION AND USER GUIDE XBR V4 INSTALLATION AND USER GUIDE xbr V4 Installation and User Guide Page 1 of 18 Revision History Dash#/Rev Date Author Description 0.1 04/03/2013 Eric Anderson Initial draft 0.2 04/08/2013 Eric Anderson

More information

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models TOT Series Manual North American CE and UK Models CE Models UK Models North American Models Table of Content 1. Important Safety Instructions 2. Description Shipping Carton & Packing Material Placement

More information

Thin clients JC500X - 1 Reference guide

Thin clients JC500X - 1 Reference guide Thin clients JC500X - 1 Reference guide 1. Product introduction 1-1 product overview Using Intel N2840 BayTrail dual-core embedded processor ( or Intel J2900), low power consumption new fashionable appearance,

More information

15 Ways Belden Helps Reduce Human Error to Improve Uptime

15 Ways Belden Helps Reduce Human Error to Improve Uptime 15 Ways Belden Helps Reduce Human Error to Improve Uptime Up to 75% of data center downtime is caused by human error. While no data center is capable of being completely immune to mistakes, implementing

More information

Power-Over-Ethernet (PoE) Weatherproof 14 x12 x7 Enclosure with Mounting Plate and Cooling Fan. Model: NB F. Applications and Features

Power-Over-Ethernet (PoE) Weatherproof 14 x12 x7 Enclosure with Mounting Plate and Cooling Fan. Model: NB F. Applications and Features Power-Over-Ethernet (PoE) Weatherproof 14 x12 x7 Mounting Plate and Cooling Fan Model: NB141207-40F Applications and Features Applications: Remote Wireless LAN WiFi equipment installations using Power-Over-

More information

Data Center Integrated solutions

Data Center Integrated solutions Data Center Integrated solutions PERFORMANCE AND RELIABILITY AT THE HEART OF DATA CENTERS 01 The growing number of business and technical demands placed on data centers today are becoming increasingly

More information

Data Center Integrated solutions

Data Center Integrated solutions Data Center Integrated solutions PERFORMANCE AND RELIABILITY AT THE HEART OF DATA CENTERS The growing number of business and technical demands placed on data centers today are becoming increasingly critical:

More information

or

or Infinite possibilities for your data center The F-Series TeraFrame T M Cabinet System The F-Series TeraFrame Cabinet System from Chatsworth Products, Inc. (CPI) provides configurable thermal management

More information

Art and Science of Building NUS Data Centres

Art and Science of Building NUS Data Centres Art and Science of Building NUS Data Centres DATA CENTRE @ NUS Contents I. Nostalgia II. III. IV. Science of Elements in a Data Centre NUS DC Live Migration the Art and Challenges Milestones in Pictures

More information

Junos WebApp Secure 5.0 Hardware Guide

Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a

More information

TIA/EIA 568A Sub-system HORIZONTAL CABLING

TIA/EIA 568A Sub-system HORIZONTAL CABLING TIA/EIA 568A Sub-system HORIZONTAL CABLING Horizontal Cabling WA 100(120)Ω CAT 3 TP TP 100(120)Ω CAT 5 150Ω STP-A 62.5(50)/125µ FIBER HC/FD WA Horizontal Media Considerations UTP/FTP Consider bandwidth,

More information

Dude Solutions Business Continuity Overview

Dude Solutions Business Continuity Overview Dude Solutions Business Continuity Overview Table of Contents Overview.... 2 Primary and Disaster Recovery Data Centers.... 2 Network Infrastructure.... 3 Emergency Processes.... 3 Power and Cooling Systems....

More information

Siemon PON Fiber Cabling Solutions

Siemon PON Fiber Cabling Solutions Siemon PON Fiber Cabling Solutions WWW.SIEMON.COM 8 Siemon Enterprise PON Fiber Cabling Solution Siemon Enterprise Passive Optical Network (PON) Fiber Cabling Solution improves the modularity, flexibility

More information

ZXA10 C320 Product Introduction V2.0

ZXA10 C320 Product Introduction V2.0 ZXA10 C320 Product Introduction V2.0 The small-capacity OLT C320 overview ZXA10 C320 Compact Frame: 2U height, 19-inch rack installation Unified Platform: GPON/P2P/XG-PON1 User-side Interfaces: 8/16*xPON

More information

Fiber Backbone Cabling in Buildings

Fiber Backbone Cabling in Buildings White Paper Fiber Backbone Cabling in Buildings www.commscope.com Contents Introduction 3 Backbone Cabling Speeds 3 Optical Fiber in the Backbone 4 b/s Optical Fiber Backbone 4 Migrating to 40 Gbps and

More information

APC APPLICATION NOTE #74

APC APPLICATION NOTE #74 #74 Configuration of InfraStruXure for Data Centers to Support Dell PowerEdge 1855 Abstract Many companies are making plans to incorporate Dell PowerEdge Blade Servers into their data center applications.

More information

Tier IV Standards as Specified in the TIA 942 Document

Tier IV Standards as Specified in the TIA 942 Document S No Architectural Proximity of visitor parking to data 18.3 m / 60 ft minimum separation with physical barriers to prevent vehicles from 1 center perimeter building walls driving closer 2 Building Construction

More information

Back-UPS RS APC Back-UPS RS 800VA 120V Black

Back-UPS RS APC Back-UPS RS 800VA 120V Black Back-UPS RS APC Back-UPS RS 800VA 120V Black APC Back-UPS RS, 540 Watts / 800 VA,Input 120V / Output 120V Includes: CD with software, Cord management straps, Free trial of anti-virus : firewall : email

More information

REQUEST FOR PROPOSAL:

REQUEST FOR PROPOSAL: REQUEST FOR PROPOSAL: FIBER CABLING INSTALLATION TO CONNECT SIX ADDITIONAL VIEWING STATIONS AT THE EMERGENCY OPERATION CENTER (EOC) WITH THE REGIONAL VIDEO COMMAND CENTER (RVCC) VIDEO FEED I. DESCRIPTION

More information

2.3 SCOPE OF WORK MATRIX TO BE INCLUDED IN DISTRICT PROJECTS

2.3 SCOPE OF WORK MATRIX TO BE INCLUDED IN DISTRICT PROJECTS NOCCCD Cabling Infrastructure Standards - Page 1 2.3 SCOPE OF WORK MATRI TO BE INCLUDED IN DISTRICT PROJECTS For each project, a Scope of Work Matrix is to be created by the construction manager and updated

More information

ADDENDUM # 7 RFP DARK FIBER OPTIC CABLE INFRASTRUCTURE LEASE

ADDENDUM # 7 RFP DARK FIBER OPTIC CABLE INFRASTRUCTURE LEASE September 25, 2013 (emailed to all proposers on this date) ADDENDUM # 7 RFP 021402 DARK FIBER OPTIC CABLE INFRASTRUCTURE LEASE Please note the following answers to questions that were asked prior to the

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Communications. UNM IT/Telecommunications Guide Specification Communications

Communications. UNM IT/Telecommunications Guide Specification Communications The material below covers specific information we definitely want to be included in the contract documents and may not be a completed specification section. This material is to be highlighted in your preliminary

More information

DATA CENTRE & COLOCATION

DATA CENTRE & COLOCATION DATA CENTRE & COLOCATION RISING DEMAND FOR HOSTED SERVICES When it comes to hosted IT infrastructure, organisations are looking for highly resilient, highly available and highly scalable facilities at

More information

Data Cabling / Low Voltage Technology Specifications

Data Cabling / Low Voltage Technology Specifications P19-02- Forsyth County Schools Data Cabling / Low Voltage Technology Specifications 1. General requirements 1.1 On premise connectivity All building closets (IDF) aside from the main closet (MDF) shall

More information

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series Owner s Manual 19 Pro Series Rack Mount (RK) Faceplate Isolate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) Colours Restore. Power Conditioners Audio / Video Power Isolation

More information

DATACENTER BERLIN Definitely a Good Perspective

DATACENTER BERLIN Definitely a Good Perspective DATACENTER BERLIN Definitely a Good Perspective We Do not Take any Chances: For the Security of Your IT Systems. Contents Your Goals 2 Compound and Buildings 4 Security 6 Infrastructure 8 Free Choice 14

More information

IP67 Certified 2T2R 2.4GHz Outdoor Wireless-N Access Point - PoE-Powered 300 Mbps b/g/n WiFi AP

IP67 Certified 2T2R 2.4GHz Outdoor Wireless-N Access Point - PoE-Powered 300 Mbps b/g/n WiFi AP IP67 Certified 2T2R 2.4GHz Outdoor Wireless-N Access Point - PoE-Powered 300 Mbps 802.11b/g/n WiFi AP Product ID: R300WN22ODE The R300WN22ODE Outdoor Wireless Access Point lets you add 2.4GHz Wireless-N

More information