Towards the Green Data Centre. Lex Coors Vice President Data Center Technology & Engineering Group
|
|
- Richard Moore
- 5 years ago
- Views:
Transcription
1 Towards the Green Data Centre Lex Coors Vice President Data Center Technology & Engineering Group
2 DC Emissions: We Have Lift-Off! Data Centre Greenhouse Gas Emissions are projected to quadruple by 2020 We will overtake the airline industry in emissions in the next 5-10 years Brace yourselves for impact! Data centres Airlines Shipyards Steel plants Carbon dioxide emissions as percentage of world total industries, 2008 [Source:IDC U.S. and Worldwide Server Installed Base Forecast; McKinsey analysis]
3 1. Moving Parts
4 Power v Energy Power Overhead (fixed) Total Energy Usage (variable)
5 Calculating PUE A. Total Energy Usage B. IT Energy Usage A B = PUE
6 How to Recognise a Green Data Centre? Inefficient DC PUE > 2 Legacy equipment No measurement Inefficient components Overspecified by builders Generally in-house Energy-conscious DC PUE Lean design Established measurement data Demonstrable year-onyear improvements Dedicated provider Typical Interxion DC Ideal DC PUE 1 1 = IT load only Not physically possible as any part of infrastructure will involve some loss
7 2. Green Steps
8 Role of the Green Data Centre Provider Interxion approach: active focus in 3 areas: 1. External efficiency focus: industry efficiency standards 3. Customer efficiency focus: proactive support and advice to improve IT efficiency 2. Internal efficiency focus: A.Design B.Operations
9 Customer Focus: Support & Advice 1. Hands-on expert support in energy efficiency implementation efforts 2. Best practice customer installation checklist (efficiency gain 3-5%) 3. Customised hot/cold aisle designs 4. Senior advice and tools in the following areas: Measurement and analysis Implementing the latest efficiency ratings Developing and implementing first phase action plans Integrating figures and ratings with customer CSR
10 Customer Focus: Recommended Steps Step 1. Eliminate Comatose servers 2. Virtualize 3. Upgrade older equipment 4. Reduce demand for new servers 5. Introduce greener and more powerefficient servers and enable power savings features Efficiency Gain 10 25% 25-30% 10 20% 10 20% 10 20% Total 65% + Source: McKinsey and Up Time Insitute 2008
11 3. Internal DC Focus: Design & Operations
12 Good Design = Less Capex For example: On 800 m 2 kva/m 2 Capex saving Tier IV Uptime vs Tier X N+N UPS s, N+1 Generator and N+1 Cooling system : 2 UPS systems of k each = 500 k/ 800 m2 = 625/m 2 2 generators of 3, k = 1.5 MIO/ 800 m2 = 1,875/m 2 1 generator 150 k = 150k/ 800 m2 = 188/ m 2 Saving on cooling: 2 UPS * 4% loss = 64 kw ( 25K for DX system) or 31/m 2 Taken together this amounts to a saving vs. Tier IV as per Uptime doc of 31+ 2, % = 3,535/ m 2 OR 3,535 * 800 m 2 = 2,828,000 less CAPEX
13 Day 1 load: 0.7 kva/m2 * 800 m2 = 560 kva UPS load * 1.8 power ratio = 1,008 kva transformer load. In this case we could: Cash Flow Management: Modular Tier X Design a) Use for the final design 4 smaller generators (3 + 1 redundant) from 1,000 kva but we would start with 2, thus saving: 2 * 750 k (3,150 kva generators) 2 * 150 k (1,000 kva generators) = 1,200,000 saving b) Use the APC-MGE Symmetra MW 1,600 kva/kw system (instead of the smaller 800 kva/kw system) starting with the final 2 frames with only 3 power modules of 200 kw per UPS system installed, thus saving: 4 * 250 k - 2 * 350 k including 600 kva/kw of UPS modules = 300,000 saving c) Start with 2 chillers of 750 kw instead of 8 chillers of 750 kw Saving at Day 1 of: 8 * 125 k 2 * 125 k = 750,000 saving d) Assuming 100 kw/ CRAC, start with 8 CRAC units instead of 16 CRAC units Saving here at day 1 will be 16 * 20 k - 8 * 20 K = 160,000 saving Total CAPEX savings day 1: 2,460,000/ 800 m 2 = 3,075/ m 2 With substantial OPEX savings for year 1
14 The Key to Efficient Operations You have to know the Power Ratio (DCi-PO) to improve the Energy ratio (PUE)
15 Internal Focus: Operational Measures Interxion 6 year PUE Gains Industry Norm Acceptable Exceptional 1 5
16 4. Industry Focus: Measure it to Manage it
17 Industry Standards for Tomorrow Getting around the table to agree efficiency metrics and a workable rating system
18 Industry Focus: The Role of Vendors The Vendor industry should provide standard meters on all equipment to measure Energy Usage v Productivity. Transformers: Energy in v Energy out UPS: Energy in v Energy out (this will allow us to measure efficiencies as a % of load) Switchgear and cables: Getting a better understanding of properties of materials and impact of impurities on efficiency CRAC units energy in v kw and kwh cold out (CRAC unit capacity should be shown at chilled water supply 9 C, 12 C, 15 C) Chillers: Energy in Energy out (Capacity shown at above temps) So finally an open invitation to Vendors: don t drive the data centre industry, let the data centre industry drive you. Let s work together to improve the available systems.
19 Conclusions Green Data Centres are real; just ask us! But emissions (and power costs) are rising fast, so we need to do more now We must work together, particularly in measurement Data Centre providers should give leadership. In three areas: Industry standards and ratings that work Data Centre design and operational efficiency steps Support for all customer IT efficiency improvements
Switch to Perfection
Switch to Perfection Traditional Data Centre - Temperatures Ideal Air Temperature: 22 C Chilled Water: 7-9 C Heat Load per Rack: Up to 4,5 Chilling & Pump Set The challenge a thermal image Front View of
More informationDC Energy, Efficiency Challenges
DC Energy, Efficiency Challenges Choosing a density strategy Implementing a high density environment Maximizing the efficiency benefit Anticipating the dynamic data center Key points on energy usage in
More informationMSYS 4480 AC Systems Winter 2015
MSYS 4480 AC Systems Winter 2015 Module 12: DATA CENTERS By Satwinder Singh 14/05/2015 1 Data Centers Data Centers are specialized environments that safeguard your company's most valuable equipment and
More informationMEASURE MONITOR UNDERSTAND
MEASURE MONITOR UNDERSTAND Presented by Alistair Hunt Energy Monitoring, Measurement metrics Where and What 1 History & Background Company Timeline 18 Years Comrac & Sinetica founded 15 Years Raritan Integration
More informationHow much power?! Data Centre Efficiency. How much Money?! Carbon Reduction Commitment (CRC)
How much power?! Data Centre Efficiency The US EPA found in 2006 data centres used 1.5% of total US consumption (5) For Bangor University data centres use approximately 5-10% of the total university electricity
More informationData Centre Energy Efficiency. Duncan Clubb EMEA Data Centre Practice Director CS Technology
Data Centre Energy Efficiency Duncan Clubb EMEA Data Centre Practice Director CS Technology Key Messages No more silos energy efficiency only comes from a holistic approach to DC design and operation If
More informationPROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES
PROCESS & DATA CENTER COOLING How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES CONGRATULATIONS 2 BOLD PREDICTION 3 Where We Are TODAY Computer Technology NOW advances more
More informationCooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.
Cooling on Demand - scalable and smart cooling solutions Marcus Edwards B.Sc. Schroff UK Limited Data Centre cooling what a waste of money! A 1MW data center needs 177,000,000 kwh in its lifetime of 10
More informationIT infrastructure Next level for data center. Rittal The System Yavor Panayotov Data center Day
IT infrastructure Next level for data center Rittal The System Yavor Panayotov Data center Day - 2018 1 Rittal The System - Solutions Enclosures Enclosures Small enclosures Command Panel & support arm
More information30 th September Always Right Size Modular Data Centres. Cannon Technologies Ltd (2015)
30 th September 2015 Glenn Conlon Always Right Size Modular Data Centres Traditional DC Build: Image courtesy of ENP Traditional DC: IRO 20 million + @ T2/3 Image courtesy of ENP DC Halls x 2, 500 Cabinets
More informationMeeting the Energy Efficiency and Financial Challenges in IT. Liam Newcombe BCS Data Centre Specialist Group Secretary
Meeting the Energy Efficiency and Financial Challenges in IT Liam Newcombe BCS Data Centre Specialist Group Secretary Meeting the Energy and Financial Challenges in IT Recognising the Problem Recognising
More informationDCIM Solutions to improve planning and reduce operational cost across IT & Facilities
DCIM Solutions to improve planning and reduce operational cost across IT & Facilities Presented by: Chi Sen, Director, Data Centre Software Solutions, APJ & EMEA Schneider Electric Data Center Solutions
More informationPlanning a Green Datacenter
Planning a Green Datacenter Dr. Dominique Singy Contribution to: Green IT Crash Course Organisator: Green IT Special Interest Group of the Swiss Informatics Society ETH-Zurich / February 13, Green Data
More informationCapacity and Power Management: The Forgotten Factors in Disaster Recovery Planning Presented by: Clemens Pfeiffer CTO Power Assure, Inc.
Capacity and Power Management: The Forgotten Factors in Disaster Recovery Planning Presented by: Clemens Pfeiffer CTO Power Assure, Inc. The Purpose of a Data Center Provide IT equipment a healthy environment
More informationGreen Data Centers A Guideline
Green Data Centers A Guideline Sekhar Kondepudi Ph.D Associate Professor Smart Buildings & Smart Cities Vice Chair Focus Group on Smart Sustainable Cities ITU-TRCSL Workshop on Greening the Future: Bridging
More informationThe End of Redundancy. Alan Wood Sun Microsystems May 8, 2009
The End of Redundancy Alan Wood Sun Microsystems May 8, 2009 Growing Demand, Shrinking Resources By 2008, 50% of current data centers will have insufficient power and cooling capacity to meet the demands
More informationThermal management. Thermal management
Thermal management Thermal management Managing thermal loads is a major challenge for all Data Centre operators. Effecting proper control of the thermal environment drives energy consumption and ultimately
More information18 th National Award for Excellence in Energy Management. July 27, 2017
18 th National Award for Excellence in Energy Management July 27, 2017 ICICI Bank, Data Centre, August Hyderabad 30 & 31, 2017 ICICI Bank - Revolution in Digital Banking Over 100,000 Digital POS in 4 months
More informationDATA CENTER LIQUID COOLING
DATA CENTER LIQUID COOLING EFFICIENT, EFFECTIVE, SUSTAINABLE What is Liquid Cooling? Key Trends & Potential Inhibitors Why are Many Owner/Operators Making the Move? Types of Liquid Cooling Solutions Liquid
More informationCase study on Green Data Center. Reliance Jio Infocomm Limited
Case study on Green Data Center 2 What is data center? Use and functions of Data Center. Basic Infrastructure requirement for data center. Energy consumption heads in data center. 3 What is Data Center
More informationEnergy Efficiency Best Practice Guide Data Centre and IT Facilities
2 Energy Efficiency Best Practice Guide Data Centre and IT Facilities Best Practice Guide Pumping Systems Contents Medium-sized data centres energy efficiency 3 1 Introduction 4 2 The business benefits
More informationPrefabricated Data Center Solutions: Coming of Age
Prefabricated Data Center Solutions: Coming of Age Steven Carlini - Global Data Center Marketing Director April 2014 Schneider Electric 1 Schneider Electric 2 Your ability to compete relies on the design,
More informationNewave s approach for protecting mission critical application
ABB Technology Show, May 2013 Newave s approach for protecting mission critical application May 13, 2013 Slide 1 Contents Newave s company overview Electricity environment and trend Data Centre environment
More informationSTATE DATA CENTER DRAFT PROPOSAL. STATE OF OREGON DATA CENTER 28 October 2016
STATE DATA CENTER DRAFT PROPOSAL 1 PROJECT TEAM 2 SERA Architects, Inc George Hager Patrick Sullivan PAE Engineers Dave Williams Doug Nachtrieb Michael Yee JMB Consulting Group Jon Bayles MEETING GOALS
More informationEcolibrium. Cloud control. Keeping data centres cool. OCTOBER 2018 VOLUME 17.9 RRP $14.95 PRINT POST APPROVAL NUMBER PP352532/00001
Ecolibrium OCTOBER 2018 VOLUME 17.9 RRP $14.95 PRINT POST APPROVAL NUMBER PP352532/00001 Cloud control Keeping data centres cool. COVER FEATURE Cloud control Such is the growth in data centres globally
More informationEvaporative free air cooling technology Providing evaporative free air cooling solutions.
Evaporative free air cooling technology Providing evaporative free air cooling solutions. Creating an effective workspace environment data centre free air cooling technology FreeCool - Evaporative Free
More informationTotal Modular Data Centre Solutions
Sector Data Centre Total Modular Data Centre Solutions www.airedale.com BRITISH MANUFACTURER ENERGY EFFICIENCY CONTROLS SERVICE TRAINING 01 Standardised Modular Designs to fit your needs Our modular system
More informationHot vs Cold Energy Efficient Data Centers. - SVLG Data Center Center Efficiency Summit
Hot vs Cold Energy Efficient Data Centers - SVLG Data Center Center Efficiency Summit KC Mares November 2014 The Great Debate about Hardware Inlet Temperature Feb 2003: RMI report on high-performance data
More informationData Center Energy Savings By the numbers
Data Center Energy Savings By the numbers Chris Kurkjian, PE HP Critical Facility Services provided by EYP Mission Critical Facilities 2008 Hewlett-Packard Development Company, L.P. The information contained
More informationSustainable Data Centre
white paper Sustainable Data Centre Tackling the Ever-rising Data Centre Energy Costs Why Only Do Half the Job? By Kari Baden Managing Director, Dimension Data Advanced Infrastructure A whitepaper on tackling
More informationData Center Trends: How the Customer Drives Industry Advances and Design Development
Bablu Kazi, PE MORRISON HERSHFIELD MISSION CRITICAL Data Center Trends: How the Customer Drives Industry Advances and Design Development What does the Customer Need? Scalability P U E Latest Technology
More informationA separate CRAC Unit plant zone was created between the external façade and the technical space.
Nominee: FES Co Ltd Nomination title: HP Cold Cube The Doxford Facility is a highly secure Data Centre. The challenge was to take advantage of the previous investment in highly resilient infrastructure
More informationCharles Nolan. Do more with less with your data centre A customer s perspective. Director IT Infrastructure, UNSW. Brought to you by:
Charles Nolan Director IT Infrastructure, UNSW Do more with less with your data centre A customer s perspective Brought to you by: Today s Enterprise Data Centre Doing more with less High Density Data
More information3300 kw, Tier 3, Chilled Water, 70,000 ft 2
[Reference Design 22] 3300 kw, Tier 3, Chilled Water, 70,000 ft 2 DESIGN OVERVIEW Data Center IT Capacity 1100 kw per Data Hall 3 Independent Data Halls Design Application Range This design can be applied
More information7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America
7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer
More informationIXcellerate Moscow One Datacentre - Phase 1 & 2 Overview
Contents 1. Document Purpose... 2 2. Facility Overview... 2 2.1 Technical Space... 2 2.2 Load Density... 2 2.3 Resilience... 2 2.4 Engineering Plant Maintenance & Service Restoration... 3 3. Engineering
More informationIntegralna rešenja Infrastrukture Data Centra
1 2 Integralna rešenja Infrastrukture Data Centra Jason Dodier, Solutions Business Development Manager - Global Sales (Schneider Electric) Overview of Prefabricated DC's market Prefab - needs to be satisfied
More informationHow Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October
How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals Michael Gagnon Coolcentric October 13 2011 Data Center Trends Energy consumption in the Data Center (DC) 2006-61 billion
More informationSmart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA
Smart Data Centres Robert M Pe, Data Centre Consultant Services SEA 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice Content Data center
More informationMaking the impossible data center a reality.
United Nations ITU WSIS 2016 WINNER E-Environment Malaysia s First Win 2015 ASIA PACIFIC WINNER 2015 Best of Sustainability and Environmental Technology WINNER 2015 Best of Sustainability and Environmental
More informationNominee: Riello UPS with The Rosebery Group
Nominee: Riello UPS with The Rosebery Group Nomination title: Cutting Costs & Carbon Emissions With Modular UPS What was the driving force behind the project? Riello UPS is one of the world s leading manufacturers
More informationHow High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions
Intel Intelligent Power Management Intel How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Power savings through the use of Intel s intelligent
More informationInvestor day. November 17, IT business Laurent Vernerey Executive Vice President
Investor day November 17, 2010 IT business Laurent Vernerey Executive Vice President IT business strategic domain Centralized generation Residential Residential Industries Non Residential Transmission
More informationSTATE OF THE ART DATA CENTRES
DATA CENTRES STATE OF THE ART DATA CENTRES In recent years, Data Centres have become increasingly important to businesses of all sizes as a higher volume of customers choose to host their servers with
More informationDatacenter Cooling. DC Cooling Efficiency and Project experience. Osman Uzuner. Vakıfbank Central Systems Management Datacenter Operations
Datacenter Cooling DC Cooling Efficiency and Project experience Osman Uzuner Vakıfbank Central Systems Management Datacenter Operations Agenda Agenda and Intro About Vakıfbank DC Energy Consumption breakdown
More informationCustomizable Colocation: Building for the Future
Customizable Colocation: Building for the Future IronGate Data Centers meets the exact needs of customers with flexible Data Center Infrastructure solutions from Schneider Electric IronGate Data Centers
More informationCase Study Leicester City Council
Data Centre Solutions...energy efficient by design Case Study Leicester City Council Leicester City Council Deploys New Sub 1.1 PUE3 Data Centre Infrastructure. Designed & Installed by Workspace Technology
More informationDatacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary
Datacenter Efficiency Trends Cary Roberts Tellme, a Microsoft Subsidiary Power Slashing Tools P3 Kill-A-WATT Measures min, max, and instantaneous voltage and current draw Calculates power (watts), kilowatt
More informationData Center. Tai Po Data Center
Data Center Tai Po Data Center TAI PO DATA CENTER Nexcenter The Global Data Center Vision NTT Communications offers data center services at hundreds of locations worldwide under the brand name Nexcenter.
More informationPower Monitoring in the Data Centre
Power Monitoring in the Data Centre Fixed or Wireless Steve Strange RCDD ANIXTER INTERNATIONAL Agenda Energy Consumption Case Study Reasons to Monitor Power Monitoring Environmental Monitoring Asset Tags
More informationCannon T4 Modular Data Center (MDC)
SOLUTIONS Cannon T4 Modular Data Center (MDC) Cannon T4 Modular Data Centers are part of Cannon T4 Data Center Solutions Cannon T4 Data Center Solutions Overview T4 Data Centers T4 Mini Data Centers T4
More informationHow green is green? The environmental benefits of using Diesel Rotary UPS systems to support critical loads in the datacenter. Summary.
How green is green? The environmental benefits of using Diesel Rotary UPS systems to support critical loads in the datacenter Summary Diesel Rotary UPS (DRUPS) systems are best in class regarding energy
More informationOptimization in Data Centres. Jayantha Siriwardana and Saman K. Halgamuge Department of Mechanical Engineering Melbourne School of Engineering
Optimization in Data Centres Jayantha Siriwardana and Saman K. Halgamuge Department of Mechanical Engineering Melbourne School of Engineering Outline Background and Motivation Overview and scale of data
More informationNext Generation Cooling
Next Generation Cooling Server Manufacturer Perspective Practical and Cost Effective David Moss Data Center Strategist Dell 1 Why Chip, Row, or Rack? Density? Energy Don t be scared; I don t see 50kW/rack
More informationLANL High Performance Computing Facilities Operations. Rick Rivera and Farhad Banisadr. Facility Data Center Management
Slide-1 LANL High Performance Computing Facilities Operations Rick Rivera and Farhad Banisadr Facility Data Center Management Division Slide-2 Outline Overview - LANL Computer Data Centers Power and Cooling
More informationRack Colocation Hosting. Data Centre Solutions Expertly Engineered
Rack Colocation Hosting www.workspace-technology.com Data Centre Solutions Expertly Engineered We are committed to ensuring the very best data centre environment for your business Rack Colocation Hosting
More informationIT Air Conditioning Units
IT Air Conditioning Units Modern Flexible Effective Energy Saving CoolTeg Plus and CoolTop overview CoolTeg Plus CW CoolTeg Plus DX CoolTeg Plus XC CoolTop Installation Between IT racks On top of IT rack
More informationAPC by Schneider Electric Elite Data Centre Partner
Data Centre Solutions...energy efficient by design APC by Schneider Electric Elite Data Centre Partner APC s leading Elite Data Centre Solutions Partner providing customers with expert advice, integration
More informationData Centre Design and Operational Best Practices
Data Centre Design and Operational Best Practices Ed Ansett Managing Partner i 3 Solutions Group ABB 5 th July 2013 Causes of Failure in Data Centres FAILURE WHO? WHAT? System Design Consulting Engineer
More informationDATA CENTRE & COLOCATION
DATA CENTRE & COLOCATION RISING DEMAND FOR HOSTED SERVICES When it comes to hosted IT infrastructure, organisations are looking for highly resilient, highly available and highly scalable facilities at
More information1200 West 7th Street, Los Angeles, CA Smart.
Overview 1200 West 7th Street, Los Angeles, CA 90017 West 7 Center is conveniently located at 1200 West 7th Street in downtown Los Angeles near the 10 and 110 freeway. This tier III datacenter facility
More informationEcolibrium. Cloud control. Keeping data centres cool. OCTOBER 2018 VOLUME 17.9 RRP $14.95 PRINT POST APPROVAL NUMBER PP352532/00001
Ecolibrium OCTOBER 2018 VOLUME 17.9 RRP $14.95 PRINT POST APPROVAL NUMBER PP352532/00001 Cloud control Keeping data centres cool. 22 ECOLIBRIUM OCTOBER 2018 The hunter and the prey A clever modernisation
More informationReference Design Quicktour Design Summary
Quicktour Design Summary Outdoor Heat Rejection Mixed Use or Purpose Built Data Center Facility Indoor/Outdoor Power Generation Mechanical Room Electrical Room Data Center Whitespace Reclaimed Whitespace
More informationData Centre Solutions. Data Centre Solutions Expertly Engineered
Data Centre Solutions www.workspace-technology.com Data Centre Solutions Expertly Engineered We will expertly deliver your data centre using our world-class skills and capabilities. Data Centre Solutions
More informationCloud environment. dr inż. Piotr Boryło , Kraków
Cloud environment dr inż. Piotr Boryło 7.03.2018, Kraków Agenda Cloud fundamentals Greening the cloud Intercloud Fog/Edge Computing Network Function Virtualization SDN for clouds Testing the cloud vs cloud
More information1.0 Executive Summary. 2.0 Available Features & Benefits
Statement Of Work Energy Management Services Table of Contents 1.0 Executive Summary 2.0 Available Features & Benefits 3.0 Assessment Deliverables Selection 4.0 On Site Assessment Activities 5.0 Exclusions
More informationWhite Paper - Infrastructure in an energy-efficient data centre
White Paper - Infrastructure in an energy-efficient data centre Verena Schwalfenberg Dipl.-Ing. Markus Schmidt Copyright 2008 All rights reserved. Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn
More informationbrightsolid Data Hall 1 Keysource Technical Specifications
brightsolid Data Hall 1 Keysource Technical Specifications Page 1 Introduction A Data Centre is a highly controlled environment that provides IT to external organisations seeking to outsource their requirements
More informationDATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency
DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency September 27 th, 2013 Tejas Desai, PE CEM CEA LEED AP Sameer Behere, PE CEM LEED AP Agenda Problem: Quick fixes can
More informationData center redundancy. Air traffic High-speed pipes. Training Design. Costs. Guy with a wrench. Terrorism
Data center redundancy Costs Training Design Air traffic High-speed High speed pipes Guy with a wrench Terrorism Fire Communications Backup and Network power Power di t ib ti distribution Security Governance
More informationLiebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology
Liebert APM from 30 to 300 kw The Compact Row Based UPS With FlexPower Technology LIEBERT APM from 30 to 300 kw Vertiv Vertiv designs, builds and services mission critical technologies that enable the
More informationEnergy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director
Energy Logic: A Roadmap for Reducing Energy Consumption in the Data Center Emerson Network Power Ross Hammond Managing Director Agenda Energy efficiency Where We Are Today What Data Center Managers Are
More informationData Centre Energy & Cost Efficiency Simulation Software. Zahl Limbuwala
Data Centre Energy & Cost Efficiency Simulation Software Zahl Limbuwala BCS Data Centre Simulator Overview of Tools Structure of the BCS Simulator Input Data Sample Output Development Path Overview of
More informationEfficiency of Data Center cooling
Efficiency of Data Center cooling Comparison of data room layouts and cooling systems Bohumil Cimbal Product manager for Cooling Systems in CONTEG Company Objective Basic questions between investor and
More informationThe Evolving Data Center
The Evolving Data Center Dominic Loh Product Manager, Power Quality, APAC Data Centers are enabling global growth Proliferation of mobile computing Digitalization of everything Big Data 2 Evolution of
More informationHighly Efficient Power Protection for High Density Computing Applications
Highly Efficient Power Protection for High Density Computing Applications IB Power and Cooling Symposium Lennart Jonsson Eaton Corporation 2007 Eaton Corporation. All rights reserved. Impact of High Density
More informationCLOSE CONTROL AIR CONDITIONERS DATA CENTERS DESIGN SIDE NOTES
CLOSE CONTROL AIR CONDITIONERS DATA CENTERS DESIGN SIDE NOTES DATA CENTER NEEDS A MINUTE IN THE LIFE OF INTERNET Evolving technology has created the necessity for ever greater exchange of data, increasing
More informationHow High-Density Colocation and Enhanced Visibility Improve Business Performance
How High-Density Colocation and Enhanced Visibility Improve Business Performance Steven So Vice President Data Center Business Cloud Business Division NTT Com Asia Limited 11 Sep 2015 NTT Communications
More informationSIX Trends in our World
Data Center Infrastructure for Cloud and Energy Efficiency SIX Trends in our World Connectivity Simplicity StruxureWare TM for data centers TuanAnh Nguyen, Solution Engineer Manager, Vietnam Schneider
More informationHow to Increase Data Center Efficiency
How to Increase Data Center Efficiency Shivani Shukla Potkar Product Marketing Manager Pentair Electronics Protection High cooling efficiency & and reduced power consumption enhances the balance between
More informationThe Green Advantage of 10G Optical Fiber
The Green Advantage of 10G Optical Fiber What is the definition of Green? Green. The word invokes natural images of deep forests, sprawling oak trees and financial images of dollar bills. The topic of
More informationFREEING HPC FROM THE DATACENTRE
FREEING HPC FROM THE DATACENTRE ku:l sistem TM COOLING REDEFINED www.iceotope.com ku:l sistem removes the need for inefficient air cooling technologies FREEING HPC FROM THE DATACENTRE Iceotope s patented
More informationDatacentre Milton Keynes Hall C Data sheet
Datacentre Milton Keynes Hall C Data sheet Data sheet Datacentre Milton Keynes Hall C Find us With 10 datacentres, over 4,500 racks and a 10Gb resilient core network between our datacentre locations, Pulsant
More informationData Centers. The Environment. December The State of Global Environmental Sustainability in Data Center Design
Data Centers & The Environment The State of Global Environmental Sustainability in Data Center Design December 2018 Today s Data Centers Data centers have a huge impact on the world we live in. Today they
More informationEXTENDING THE LIFECYCLE OF AGEING DATA CENTRES:
EXTENDING THE LIFECYCLE OF AGEING DATA CENTRES: HOW AND WHAT SHOULD DC s DO FOR RETROFITS Jonathan Price 4 th August 2015 KEY DRIVERS FOR UPGRADING A DATA CENTRE Capacity Resilience Efficiency Lifecycle
More informationCRITICAL FACILITIES ROUNDTABLE HEAT REMOVAL IN DATA CENTERS ENGINEERED SOLUTIONS
CRITICAL FACILITIES ROUNDTABLE HEAT REMOVAL IN DATA CENTERS ENGINEERED SOLUTIONS Peter Klock, P.E., President ESC Engineering Services Company peter@escengineering.com Bill Henry, P.E., Consulting Mechanical
More informationRack Centric - High Voltage Distribution
Rack Centric - High Voltage Distribution Randy Malik Senior Technical Staff Member Research Triangle Park Raleigh, North Carolina Email: Rmalik@us.ibm.com Data Center Application Typical Data Center Energy
More informationIncreasing Data Center Efficiency through Metering and Monitoring Power Usage
White Paper Intel Information Technology Computer Manufacturing Data Center Efficiency Increasing Data Center Efficiency through Metering and Monitoring Power Usage To increase data center energy efficiency
More informationGreen Sustainable Data Centres. Checklist - EU Code of Conduct on Data Centres. Annex
Green Sustainable Data Centres Checklist - EU Code of Conduct on Data Centres Annex This course is produced under the authority of e-infranet: http://e-infranet.eu/ Course team prof. dr. Colin Pattinson,
More informationNON ISO Modular Datacenter
NON ISO Modular Datacenter NON ISO MODULAR DATACENTER Benefits NON ISO Modular Data Center is a purpose-engineered and fully > Differed Capex. integrated datacenter system designed to offer organizations
More informationPower & Cooling Considerations for Virtualized Environments
Power & Cooling Considerations for Virtualized Environments Cisco Data Center Day 2008 31-01-2008 APC-MGE Vision & Mission OUR VISION APC-MGE products ensure availability wherever data is created, transmitted
More informationRolf Brink Founder/CEO
Rolf Brink Founder/CEO +31 88 96 000 00 www.asperitas.com COPYRIGHT 2017 BY ASPERITAS Asperitas, Robertus Nurksweg 5, 2033AA Haarlem, The Netherlands Information in this document can be freely used and
More informationVirtualization and consolidation
Virtualization and consolidation Choosing a density strategy Implementing a high-density environment Maximizing the efficiency benefit Anticipating the dynamic data center Schneider Electric 1 Topical
More informationTopics Covered in this Presentation
DATA CENTER DESIGN CONSIDERATIONS AND TRENDS MUSIC CITY POWER QUALITY GROUP May 5, 2009 Daniel L. Ellis - Eaton 2008 Eaton Corporation. All rights reserved. Topics Covered in this Presentation Economic
More informationims - Modular DCIM Solution
ims - Modular DCIM Solution Data Centre Infrastructure Management System Get in touch! Andy Banks Power Management Director m. +44 (0) 7920 136987 t. +44 (0) 1539 720161 e. a.banks@mardix.co.uk Scott Findlater
More informationThe European Programme for Energy Efficiency in Data Centres: The Code of Conduct
The European Programme for Energy Efficiency in Data Centres: The Code of Conduct Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport 1 Why Data Centres? Continuing demand for
More informationRittal Cooling Solutions A. Tropp
1 Rittal Cooling Solutions Presented by Adam Tropp 2 Agenda Cooling Strategies Aisle Containment Chimney Solution Airstream Management Rittal Liquid Cooling Packages Data Monitoring 3 Cooling strategies.
More informationHVAC system design to operational efficiency: Strategies and Metrics for improved Total Cost of Ownership
HVA system design to operational efficiency: Strategies and Metrics for improved otal ost of Ownership Michel van Roozendaal Vice President Services and ontracting limate Solutions, urope, Middle ast Africa
More informationGreen IT Project: The Business Case
Green IT Project: The Business Case Indumathi Lnu University at Albany DATE We will discuss Identifying green IT projects Funding green IT projects Building the business case Case study: University at
More information84 kw, Tier 3, Direct Expansion, 937 ft 2
[Reference Design 42] 84 kw, Tier 3, Direct Expansion, 937 ft 2 DESIGN OVERVIEW Data Center IT Capacity 84 kw Target Availability Tier 3 Annualized PUE at 100% Load 1.712 Total Racks and Average Density
More information