G4CM690V16ATL20 Part No Technical data. Power factor monitoring (cosφ) in 1- or 3-phase mains

Size: px
Start display at page:

Download "G4CM690V16ATL20 Part No Technical data. Power factor monitoring (cosφ) in 1- or 3-phase mains"

Transcription

1 Power factor montorng (cosφ) n 1- or 3-phase mans Loadmontors - GAMMA seres Montorng of nductve and capactve consumers Multfuncton Temperature montorng of the motor wndng -ey, Fault latch Recognton of dsconnected consumers as good or fault state Sutable for VFI (10 to 100Hz) Supply voltage selectable va power modules 2 change over contacts Wdth 45mm Industral desgn G4CM690V16AT0 Read and understand these nstructons before nstallng, operatng or mantanng the equpment. Techncal data 1. Functons Load montorng (cosφ) of nductve and capactve consumers n 1- or 3-phase mans wth adjustable thresholds (cosφ1, cosφ2), tmng for start-up supresson and trppng delay separately adjustable, selectable fault latch, temperature montorng of the motor wndng wth max. 6 PTC, reset-ey and the followng functons whch are selectable by means of rotary swtch: 2MI 2MI+I< O 2MI+I< Inv. 2MAX 2MAX+I< O 2MAX+I< Inv. WI WI+I< O WI+I< Inv. Danger! ever carry out wor on lve parts! Danger of fatal njury! The product must not be used n case of obvous damage. To be nstalled by an authorzed person. MI/MAX MI/MAX+I< O MI/MAX+I< Inv. 2. Tme ranges Adjustment range -up suppresson tme: 3s 180s Trppng delay: 1s 50s 3. Indcators Green O: Green flashes: Yellow O/OFF: Red LED Falure O: Red LED Falure flashes: Mnmum montorng Mnmum montorng and recognton of dsconnected consumers (relay O f I<) Mnmum montorng and recognton of dsconnected consumers (relay OFF f I< Inv.) Maxmum montorng Maxmum montorng and recognton of dsconnected consumers (relay O f I<) Maxmum montorng and recognton of dsconnected consumers (relay OFF f I< Inv.) Montorng the wndow between MI and MAX Montorng the wndow between MI and MAX and recognton of dsconnected consumers (relay O f I<) Montorng the wndow between MI and MAX and recognton of dsconnected consumers (relay OFF f I< Inv.) Mnmum- and maxmum montorng Mnmum- and maxmum montorng and recognton of dsconnected consumers (relay O f I<) Mnmum- and maxmum montorng and recognton of dsconnected consumers (relay OFF f I< Inv.) ndcaton of supply voltage ndcaton of start-up suppresson tme ndcaton of dsconnected consumers ndcaton of falure of the correspondng threshold cosφ1 or/and cosφ2 ndcaton of trppng delay of the correspondng threshold cosφ1 or/and cosφ2 ndcaton of overtemperature Red LED Temp O/OFF: Yellow LED O/OFF: ndcaton of relay output Yellow LED O/OFF: ndcaton of relay output 4. Mechancal desgn Self-extngushng plastc housng, IP ratng IP40 Mounted on DI-Ral TS 35 accordng to E 607 Mountng poston: any Shocproof termnal connecton accordng to VBG 4 (PZ1 requred), IP ratng IP20 Tghtenng torque: max. 1m Termnal capacty: 1 x 0.5 to 2.5mm² wth/wthout multcore cable end 1 x 4mm² wthout multcore cable end 2 x 0.5 to 1.5mm² wth/wthout multcore cable end 2 x 2.5mm² flexble wthout multcore cable end 5. Input crcut Supply voltage: 12 to 500V a.c. termnals - (galvancally seperated) selectable va power module type TR3 Tolerance: accordng to specfcaton of power module Rated frequency: accordng to specfcaton of power module Rated consumpton: 3.5VA (3W) Duraton of operaton: 100% tme: 500ms Rpple and nose: - Drop-out voltage: >30% of the supply voltage Overvoltage category: III (n accordance wth IEC ) Rated surge voltage: 4V 6. Output crcut 2 potental free change over contacts Rated voltage: 0V a.c. Swtchng capacty: 10VA (5A / 0V a.c.) If the dstance between the devces s less than 5mm! Rated voltage: 2000VA (8A / 0V a.c.) If the dstance between the devces s greater than 5mm! Fusng: 5A fast actng Mechancal lfe: 20 x 10 6 operatons Electrcal lfe: 2 x 10 5 operatons at 1000VA resstve load Swtchng capacty: max. 60/mn at 100VA resstve load max. 6/mn at 1000VA resstve load (n accordance wth IEC ) Wthstand voltage across open contacts: 1000V eff a.c. Overvoltage category: III (n accordance wth IEC ) Rated surge voltage: 4V 7. Measurng crcut Measurng ranges: reversble between 8A (4,8W) and 16A (19,6W) Wave form: AC Snus: 10 to 100Hz Measurng nput voltage: termnals -- 1-phase load: 85 to 690V a.c. 3-phase load: 3~ 85 to 690/400V Overload capacty: 1-phase load: 796V a.c. 3-phase load: 3~ 796/460V a.c. Input resstance: 1.MΩ Measurng nput current: termnals - Measurng range 8A: 1 to 8A Measurng range 16A: 2 to 16A (for I>16A dstance >5mm) Overlaod capacty: 20A permanent 1A (8x16A) maxmum 7 seconds, Cooldown for mnmum 2 mnutes!

2 Techncal data I< - recognton: Current flow nterrupton: Measurng range 8A: Measurng range 16A: Current flow recognton: Measurng range 8A: Measurng range 16A: Swtchng threshold: Swtchng threshold cosφ1: Swtchng threshold cosφ2: Hysteress: 200mA 400mA 240mA 480mA 0.3 to 1 (nductve) 1 to 0.3 (capactve) 0.3 to 1 (nductve) 1 to 0.3 (capactve) approx. 5% (cosφ) Temperature montorng: Termnals: - (max. 6 PTC) Intal resstance: <1.5Ω Response value (Relas n on-poston): 3.6Ω Release value (Relas n off-poston): 1.8Ω Dsconnecton (short crcut thermstor): no Measurng voltage -: 7.5V at R 4.0Ω (n accordance wth E ) Overvoltage category: III (n accordance wth IEC ) Rated surge voltage: 4V 8. Control contact Y (equpotental wth measurng crcut) Functon: latch (termnal brdged) Loadable: no Control pulse length: - : normally closed contact n the nput crcut 9. Accuracy Base accuracy: ±3% (of maxmum scale value) Frequency response: ±0.0% / Hz Adjustment accuracy: 5% (of maxmum scale value) Repetton accuracy: ±2% Voltage nfluence: - Temperature nfluence: 0.02% / C 10. Ambent condtons Ambent temperature: - to +55 C (n accordance wth IEC ) - to +40 C (n accordance wth L 508) - to +70 C Storage temperature: Transport temperature: - to +70 C Relatve humdty: % to 85% (n accordance wth IEC class 3K3) Polluton degree: 2 (n accordance wth E ) Vbraton resstance: class 1 (n accordance wth E ) Shoc resstance: class 1 (n accordance wth E ) Functons When the supply voltage s appled (green llumnated) the output relays and swtches nto on-poston (yellow LED and Rel 2 llumnated) and the set nterval of the start-up suppresson tme () begns (green flashes). Changes of the measured power factor durng ths perod don t affect the state of the output relays and. After the nterval has expred the green llumnates steadly. Apples to all cases of applcatons: The adjusted threshold cosφ1 always has to be adjusted more to the rght than cosφ2. Otherwse both output relays swtch nto off-poston (both red LEDs Falure flash alternately). The followng specfcatons should avod ncorrect settngs: Montorng of nductve loads: Both thresholds have to be adjusted n the left half (ID) of the cosφ-scale. Montorng of capactve loads: Both thresholds have to be adjusted n the rght half (KAP) of the cosφ-scale. Montorng of loads that can be both nductve as well as capactve: cosφ1 has to be adjusted n the rght half (KAP) and cosφ2 n the left half (ID) of the cosφ-scale Mnmum montorng (2MI) for nductve loads cosφ1-regulator (e.g. electronc load of motor drops), the set nterval of the trppng delay () begns (red LED Falure of the correspondng threshold cosφ1 flashes). After the nterval has expred (red LED Falure of the correspondng threshold cosφ1 llumnated), the output relay swtches nto off-poston (yellow LED not llumnated). cosφ2-regulator, the set nterval of the trppng delay () begns (red LED Falure of the correspondng threshold cosφ2 flashes). After the nterval has expred (red LED Falure of the correspondng threshold cosφ2 llumnated), the output relay swtches nto off-poston (yellow LED not llumnated). As soon as the measured power factor exceeds the adjusted value at the correspondng regulator cosφ1 or cosφ2 (red LED Falure of the correspondng threshold cosφ1 or cosφ2 not llumnated), the output relay or swtches nto on-poston agan (yellow LED or Rel 2 llumnated). LED Falure Mnmum montorng (2MI) for capactve loads The functon 2MI can also be used to montor capactve loads. In ths case the montorng functon doesn t apples f the power factor falls below the selected threshold but apples f the power factor falls below the correspondng phase angle. Maxmum montorng (2MAX) for nductve loads cosφ2-regulator (e.g. electronc load of motor ncreases), the set nterval of the trppng delay () begns (red LED Falure of the correspondng threshold cosφ2 flashes). After the nterval has expred (red LED Falure of the correspondng threshold cosφ2 llumnated), the output relay swtches nto off-poston (yellow LED not llumnated). cosφ1-regulator, the set nterval of the trppng delay () begns (red LED Falure of the correspondng threshold cosφ1 flashes). After the nterval has expred (red LED Falure of the correspondng threshold cosφ1 llumnated), the output relay swtches nto off-poston (yellow LED not llumnated). As soon as the measured power factor falls below the adjusted value at the correspondng regulator cosφ1 or cosφ2 (red LED Falure of the correspondng threshold cosφ1 or cosφ2 not llumnated), the output relay or swtches nto on-poston agan (yellow LED or Rel 2 llumnated). LED Falure G4CM690V16AT0 Maxmum montorng (2MAX) for capactve loads The functon 2MAX can also be used to montor capactve loads. In ths case the montorng functon doesn t apples f the power factor exceeds the selected threshold but apples f the power factor exceeds the correspondng phase angle. For the selecton of the montorng functon t has to be taen nto account that dsconnected consumers effect that a measured cosφ = 1 s assumed. A measured cosφ = 0.95 up to 1 s assumed as cosφ = 1 by the devce.

3 Functons Wndow functon (WI) for nductve loads cosφ2-regulator (e.g. electronc load of motor drops), the set nterval of the trppng delay () begns (red LED Falure of the correspondng threshold cosφ2 flashes). After the nterval has expred (red LED Falure of the correspondng threshold cosφ2 llumnated), the output relays Rel 1 and swtches nto off-poston (yellow LED and not llumnated). The output relays and swtches nto on-poston agan (yellow LED and llumnated), as soon as the the measured power factor exceeds the adjusted value at the cosφ2-regulator (red LED Falure of the correspondng threshold cosφ2 not llumnated). cosφ1-regulator, the set nterval of the trppng delay () begns (red LED Falure of the correspondng threshold cosφ1 flashes). After the nterval has expred (red LED Falure of the correspondng threshold cosφ1 llumnated), the output relays and swtches nto offposton (yellow LED and not llumnated). As soon as the measured power factor falls below the value adjusted at the cosφ1- regulator (red LED Falure of the correspondng threshold cosφ1 not llumnated) the output relays and swtches nto on-poston agan (yellow LED and llumnated). G4CM690V16AT0 Mnmum- and maxmum montorng (MI/MAX) for capactve loads The functon MI/MAX can also be used to montor capactve as well as nductve/capactve loads. In ths case cosφ1 montors the more capctve part and cosφ2 the more nductve part of the wndow. Wthn ths wndow the output relays Rel1 and Rel2 reman n on-poston. If the measured power factor falls below or exceeds the adjusted wndow both output relays swtch nto off-poston. Fault latch The fault latch can be actvated va brdge between the termnals Y1 and Y2. If the fault latch s actvated and a falure has occured (red LED of the correspondng threshold or red LED Temp llumnated), the falure can only be reset f no fault s actve any more and by nterruptng the supply voltage, by pressng the reset-ey or by openng the brdge. After resettng the falure and re-applyng to the supply voltage, the output relays and swtch nto on-poston agan and the measurng cycle begns wth the set nterval of the start-up suppresson tme (). ote: The fault latch remans actve nspte of a I=0 recognton! Example: Wndow functon (WI) - tng the fault latch by nterruptng the supply voltage LED Falure LED Falure Latch actve (Brdge ) Wndow functon (WI) for capactve loads The functon WI can also be used to montor capactve as well as nductve/capactve loads. In ths case cosφ1 montors the more capctve part and cosφ2 the more nductve part of the wndow. Wthn ths wndow the output relays Rel1 and Rel2 reman n on-poston. If the measured power factor falls below or exceeds the adjusted wndow both output relays swtch nto off-poston. Mnmum- and maxmum montorng (MI/MAX) for nductve loads cosφ2-regulator (e.g. electronc load of motor drops), the set nterval of the trppng delay () begns (red LED Falure of the correspondng threshold cosφ2 flashes). After the nterval has expred (red LED Falure of the correspondng threshold cosφ2 llumnated), the output relay swtches nto off-poston (yellow LED not llumnated). The output relay swtches nto on-poston agan (yellow LED llumnated), as soon as the the measured power factor exceeds the adjusted value at the cosφ2-regulator (red LED Falure of the correspondng threshold cosφ2 not llumnated). cosφ1-regulator, the set nterval of the trppng delay () begns (red LED Falure of the correspondng threshold cosφ1 flashes). After the nterval has expred (red LED Falure of the correspondng threshold cosφ1 llumnated), the output relay swtches nto off-poston (yellow LED not llumnated). As soon as the measured power factor falls below the value adjusted at the cosφ1-regulator (red LED Falure of the correspondng threshold cosφ1 not llumnated) the output relay swtches nto on-poston agan (yellow LED llumnated). LED Falure Example: Wndow functon (WI) - tng the fault latch by pressng the reset-ey for mnmum 1 second LED Falure Latch actve (Brdge ) 1s Example: Wndow functon (WI) - tng the fault latch by openng the brdge between Y1 and Y2 LED Falure Latch actve (Brdge ) Latch actve 1s

4 G4CM690V16AT0 Functons Recognton of dsconnected consumers The followng apples for functons, where the I=0 recognton s actvated: When the current flow between and s nterrupted (yellow llumnated) and the mnmum-, wndow- or mnmum- and maxmum functon s actvated (2MI+I=0, WI+I=0, MI/MAX+I=0), the output relays and remans nto on-poston (yellow LED and LED llumnated). When the maxmum functon s actvated (2MAX+I=0), the output relays and swtches nto off-poston (yellow LED and LED Rel 2 not llumnated). When the current flow restores, the measurng cycle s restarted wth the set nterval of the start-up suppresson tme () (green flashes). I=0 wth mnmum montorng (2MI+I=0) LED Falure I=0 Inv. wth mnmum montorng (2MI+I=0 Inv.) LED Falure I=0 I=0 Inv. wth maxmum montorng (2MAX+I=0 Inv.) LED Falure I=0 I=0 wth maxmum montorng (2MAX+I=0) LED Falure I=0 The followng apples for functons, where the nverted I=0 recognton s actvated: When the current flow between and s nterrupted (yellow llumnated), the output relays behaves nverse to the above mentoned functon. If the mnmum-, wndow- or mnmum- and maxmum functon (2MI+I=0 Inv., WI+I=0 Inv., MI/MAX+I=0 Inv.) s actvated, the output relays Rel 1 and swtches nto off-poston (yellow LED and LED not llumnated). When the maxmum functon s actvated (2MAX+I=0 Inv.), the output relays and remans n on-poston (yellow LED and LED llumnated). When the current flow restores, the measurng cycle s restarted wth the set nterval of the start-up suppresson tme () (green flashes). I=0 Temperature montorng of the motor wndng If the supply voltage s appled (green llumnated) and the cumulatve resstance of the PTC-crcut s less than 3.6Ω (standard temperature of the motor), the output relay swtches nto on-poston f no other falure s appled! When the comulatve resstance of the PTCcrcut exceeds 3.6Ω (at least one of the PTCs has reached the cutoff temperature), the output relay swtches nto off-poston (yellow LED not llumnated) and a falure wll be ndcated (red LED Temp llumnated). The output relay swtches nto on-poston agan (yellow LED llumnated) respectvely the falure wll be cancelled (red LED Temp not llumnated), f the cumulatve resstance drops below 1.8Ω by coolng down of the PTC. If the fault latch s actvated, a press of th reset-ey s requred to cancel the temperature falure. Temperature montorng wthout fault latch LED Temp 3,6Ω 1,8Ω PTC Temperature montorng wth fault latch LED Temp 3,6Ω 1,8Ω PTC <1s 1s ote: If the output relay should swtch nto on-poston agan, no other falure should be appled!

5 Connectons Connected 3~ 400/690V wth power module 24V a.c. wthout fault latch I Connected 3~ 400/690V wth power module 400V a.c. wth fault latch and current transformer I >16A G4CM690V16AT0 24V~ 0V Y1 Y2 Connected 3~ 500V wth power module 500V a.c. wth fault latch I ote: Before worng on current transformer crcuts, these shall be shortcrcuted. Connected 1~ 230V wth power module 24V a.c. wthout fault latch I 24V~ 0V Connected 3~ 230/400V wth power module 230V a.c. wth fault latch and temperature montorng sensor I Dmensons Powermodul 90mm 103mm 5mm 45mm TELE Haase Steuergeräte Ges.m.b.H. Vorarlberger Allee 38 AT-1230 Venna, ASTRIA RELEASE 2017/01 Subject to alteratons and errors

4-channel universal dimming actuator 210W Installation Instructions

4-channel universal dimming actuator 210W Installation Instructions 4-channel unversal dmmng actuator 210W Order no.: 1043 00 System nformaton Ths devce s a product of the Instabus KNX/EIB-system and comples wth KNX drectves. Techncal knowledge obtaned n KNX tranng courses

More information

FIBARO WALL PLUG OPERATING MANUAL FGBWHWPE-102/FGBWHWPF-102 CONTENTS

FIBARO WALL PLUG OPERATING MANUAL FGBWHWPE-102/FGBWHWPF-102 CONTENTS OPERATING MANUAL EN FIBARO WALL PLUG FGBWHWPE-102/FGBWHWPF-102 CONTENTS #1: Descrpton and features 3 #2: Parng the accessory 4 #3: Reset 5 #4: Functonalty 6 v1.0 #5: W-F 8 #6: Confgurable parameters 9

More information

InfoTerminal Touch Installation Instructions

InfoTerminal Touch Installation Instructions Order no.: 2071 xx 1. Safety warnngs Electrcal equpment must be nstalled and ftted by qualfed electrcans only and n strct observance of the relevant accdent preventon regulatons. Cut out the crcut breaker

More information

Filling level and Temperature Sensor HFT C4 / R / MD

Filling level and Temperature Sensor HFT C4 / R / MD Fllng level and Temperature Sensor HFT C4 / R / MD Level measurng range 0.25-5.0 m Pressure measurng range 0-0.5 bar Temperature measurng range -10 100 C Voltage supply 18 30 V DC Features Fllng level

More information

VRT012 User s guide V0.1. Address: Žirmūnų g. 27, Vilnius LT-09105, Phone: (370-5) , Fax: (370-5) ,

VRT012 User s guide V0.1. Address: Žirmūnų g. 27, Vilnius LT-09105, Phone: (370-5) , Fax: (370-5) , VRT012 User s gude V0.1 Thank you for purchasng our product. We hope ths user-frendly devce wll be helpful n realsng your deas and brngng comfort to your lfe. Please take few mnutes to read ths manual

More information

In this section, user interface of the device, how to access to the parameters, description of the parameters are explained.

In this section, user interface of the device, how to access to the parameters, description of the parameters are explained. ABOUT INSTRUCTION MANUAL Instructon manual of ESM-4450 Process Controller conssts of two man sectons. Explanaton of these sectons are below. Also, there are other sectons whch nclude order nformaton and

More information

General Description. Description

General Description. Description June 0 Sheet 0 Metal-Enclosed Swtchgear MVS Medum Voltage Load Interrupter Fusble Swtch General Descrpton.0- Motor Operated MVS Swtches Applcaton Eaton s Cutler-Hammer MVS Pow-R- Drve motor operator makes

More information

IP Camera Configuration Software Instruction Manual

IP Camera Configuration Software Instruction Manual IP Camera 9483 - Confguraton Software Instructon Manual VBD 612-4 (10.14) Dear Customer, Wth your purchase of ths IP Camera, you have chosen a qualty product manufactured by RADEMACHER. Thank you for the

More information

Actuator / controller for electrothermal actuators

Actuator / controller for electrothermal actuators Actuator / controller for electrothermal actuators Code: EK-HE1-TP Datasheet STEKHE1TP_E KX devce for control of electrothermal actuators for zone valves n heatng and / or coolng systems. It has to be

More information

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA Continous voltage monitoring Mains fluctuation detection Detects voltage drop / short interruptions of at least 10ms Prevents undefined states in switching and control systems Generates reset pulse after

More information

0.5 to 125A: Multi 9 circuit breakers symetrical rail mounting

0.5 to 125A: Multi 9 circuit breakers symetrical rail mounting BS EN 69 45Va ka EC 947. 3Va a 45 6 ka EC 947. 9 ka EC 947. mensuel monthly 3 N N.5 5A: Mult 9 crcut breakers symecal ral mountng DPN Vg C6 NC mult 9 DPN vg C4 n,3a - mult 9 NCH CA 7 mult 9 C6N C63 4Va

More information

Bangalore Electricity Supply Company Limited (wholly owned Government of Karnataka undertaking)

Bangalore Electricity Supply Company Limited (wholly owned Government of Karnataka undertaking) Format - 5 Bangalore Electrcty Supply Company Lmted (wholly owned Government of Karnataka undertakng) Telephone : Emal ID : Ref No.: Offce of the.. Date: To, (Name & address of the applcant) Madam/Sr,

More information

Product Information. XY compensation unit with spring return AGE-F

Product Information. XY compensation unit with spring return AGE-F Product Informaton AGE-F AGE-F Flat. Flexble. Compact. Compensaton unt for applcatons n assembly, loadng, and unloadng of machnes and workpece carrers. The use of AGE-F makes t possble to safely grp and

More information

PT100 SCANNER. EPLC9600-CHANNEL8 96 x 96 DIN 1/4. 8 Channel PT-100 Scanner

PT100 SCANNER. EPLC9600-CHANNEL8 96 x 96 DIN 1/4. 8 Channel PT-100 Scanner PT SCANNER EPLC96CHANNEL8 96x96 /4 DIN EPLC96CHANNEL8 96 x 96 DIN /4 8 Channel PT Scanner 8 x 64 Graphcal LCD dsplay 8 PT temperature sensor nputs ONOFF control Relay or (pnp source ) transstor output

More information

Wireless Temperature Monitoring Overview

Wireless Temperature Monitoring Overview Wreless Temperature Montorng Overvew Wreless Temperature Montorng and Alerts. Your Dashboard gves you advanced montorng, alerts (SMS or Emals), graphng and PDF reports from anywhere n the world. Product

More information

TRAINING LEVEL II. RECIPIENTS Installation companies with the MD training lv1 Distributors with MD training lv1

TRAINING LEVEL II. RECIPIENTS Installation companies with the MD training lv1 Distributors with MD training lv1 TRAINING LEVEL II RECIPIENTS Installaton companes wth the MD tranng lv1 Dstrbutors wth MD tranng lv1 - Z-WAVE - APPs - LP283WD - LP15 - PSB - OCT41 - OC66 - DI32 - OF88 - AC88 - LD88 - METEO - LED88 -

More information

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status

More information

Installation manual for control panel for 2-motor 24V automations with built-in radio AUX. Electric lock. Flashing light 24V= 24V=

Installation manual for control panel for 2-motor 24V automations with built-in radio AUX. Electric lock. Flashing light 24V= 24V= Dtec E2H Installaton manual for control panel for 2-motor 24V automatons wth bult-n rado IP1967EN Power unt BATK1 TRF 24V AUX COM Memory card ANT JR5 POWER GOL4 FUSE ESC ENTER DOWN UP F1 L N 36 35 34 33

More information

EN Operating and installation instructions for RADEMACHER tubular motors... 27

EN Operating and installation instructions for RADEMACHER tubular motors... 27 Operatng and nstallaton nstructons for RADEMACHER tubular motors... 27 Applcable for the followng seres: RolloTube Intellgent Small/Medum Item numbers: 2640 06 95 / 2640 10 95 / 2660 10 95 / 2660 20 95

More information

LED Fixture Controller ELED1 Programming Guide

LED Fixture Controller ELED1 Programming Guide LED Fxture Controller ELED1 Programmng Gude ELED1-AUN ELED1-AUS Copyrght 2018 Echoflex Solutons, Inc. All rghts reserved. Product nformaton and specfcaton detals subject to change Document number: 8DC-5745

More information

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA Off-Delay 10 time ranges Supply voltage 24-240V AC/DC 1 change-over contact Width 22,5 mm Control elements Fine adjustment Setting of time range Status indication LED U/t: Supply voltage LED R: Relay status

More information

Installation and User Guide. Digidim Remote Control (303) Product description. Switching Lights On/Off using Digidim 303 Remote

Installation and User Guide. Digidim Remote Control (303) Product description. Switching Lights On/Off using Digidim 303 Remote Installaton and User Gude Dgdm Remote Control (0) Product descrpton The Dgdm Remote (0) can be used n conjuncton wth the Dm Sense to modfy the preset lght levels and recall/ store scenes, as well as actvatng

More information

Metal-Enclosed Switchgear MVS Medium Voltage Load Interrupter Fusible Switch MVS Load Interrupter Switchgear. Description.

Metal-Enclosed Switchgear MVS Medium Voltage Load Interrupter Fusible Switch MVS Load Interrupter Switchgear. Description. .0- Metal-Enclosed Swtchgear MVS Medum Voltage General Descrpton June 0 Sheet 0 MVS Load Interrupter Swtchgear Descrpton Eaton s Cutler-Hammer MVS Load Interrupter Swtchgear s an ntegrated assembly of

More information

FIBARO DIMMER 2 OPERATING MANUAL FGD-212 CONTENTS

FIBARO DIMMER 2 OPERATING MANUAL FGD-212 CONTENTS OPERATING MANUAL EN FIBARO DIMMER 2 FGD-212 CONTENTS #1: Descrpton and features 4 #2: Supported loads 5 #3: FIBARO Bypass 2 (FGB-002) 7 #4: Installaton 8 #5: Addng/removng the devce 11 #6: Operatng the

More information

FIBARO DIMMER 2 OPERATING MANUAL FGD-212 CONTENTS

FIBARO DIMMER 2 OPERATING MANUAL FGD-212 CONTENTS OPERATING MANUAL EN FIBARO DIMMER 2 FGD-212 CONTENTS #1: Descrpton and features 4 #2: Supported loads 5 #3: FIBARO Bypass 2 (FGB-002) 7 #4: Installaton 8 #5: Addng/removng the devce 11 #6: Operatng the

More information

TECHNIQUE OF FORMATION HOMOGENEOUS SAMPLE SAME OBJECTS. Muradaliyev A.Z.

TECHNIQUE OF FORMATION HOMOGENEOUS SAMPLE SAME OBJECTS. Muradaliyev A.Z. TECHNIQUE OF FORMATION HOMOGENEOUS SAMPLE SAME OBJECTS Muradalyev AZ Azerbajan Scentfc-Research and Desgn-Prospectng Insttute of Energetc AZ1012, Ave HZardab-94 E-mal:aydn_murad@yahoocom Importance of

More information

FIBARO DIMMER 2 OPERATING MANUAL FGD-212 CONTENTS

FIBARO DIMMER 2 OPERATING MANUAL FGD-212 CONTENTS OPERATING MANUAL US FIBARO DIMMER 2 FGD-212 CONTENTS #1: Descrpton and features 4 #2: Supported loads 5 #3: FIBARO Bypass 2 (FGB-002) 7 #4: Installaton 8 #5: Addng/removng the devce 11 #6: Operatng the

More information

Codian MCU MCU 4200 Series

Codian MCU MCU 4200 Series Codan MCU MCU 4200 Seres Gettng started Codan MCU MCU 4200 Seres Gettng started Copyrght Codan 2008. All rghts reserved. Ths Gettng Started Gude may not be coped, photocoped, translated, reproduced, or

More information

Avaya T3 Telephones connected to Integral 5 Setting up and using conference bridge Appendix to user s guide

Avaya T3 Telephones connected to Integral 5 Setting up and using conference bridge Appendix to user s guide Avaya T3 Telephones connected to Integral 5 Settng up and usng conference brdge Appendx to user s gude Issue 1 Integral 5 Software Release 2.6 September 2009 Use conference room Use conference room Your

More information

FIBARO DIMMER 2 OPERATING MANUAL FGD-212 ENG CONTENTS

FIBARO DIMMER 2 OPERATING MANUAL FGD-212 ENG CONTENTS OPERATING MANUAL ENG FIBARO DIMMER 2 FGD-212 CONTENTS #1: Descrpton and features 4 #2: Supported loads 5 #3: FIBARO Bypass 2 (FGB-002) 7 #4: Installaton 8 #5: Addng/removng the devce 11 #6: Operatng the

More information

Bangalore Electricity Supply Company Limited (wholly owned Government of Karnataka undertaking)

Bangalore Electricity Supply Company Limited (wholly owned Government of Karnataka undertaking) Telephone : Emal ID : Ref No.: Format 6 For HT consumers Bangalore Electrcty Supply Company Lmted (wholly owned Government of Karnataka undertakng) Offce of the.. Date: To, (Name & address of the applcant)

More information

with Optic65 and Optic25 Cameras FOR OUTDOOR TRACKING ONLY unless used in conjunction with the Indoor Tracking Accessory.

with Optic65 and Optic25 Cameras FOR OUTDOOR TRACKING ONLY unless used in conjunction with the Indoor Tracking Accessory. wth Optc6 and Optc Cameras Quck Start Gude FOR OUTDOOR TRACKING ONLY unless used n conjuncton wth the Indoor Trackng Accessory. CONGRATULATIONS ON SCORING YOUR SOLOSHOT Our category-creatng lne of personal

More information

F-5000 View Software Installation and Operation Guide Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

F-5000 View Software Installation and Operation Guide Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727) ONICON Flow and Energy Measurement F-5000 Vew Software Installaton and Operaton Gude 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727)442-5699 2032-1 / 107050 Rev B www.oncon.com

More information

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h. On-Delay 10 time ranges Supply voltage 24-240V AC/DC 1 change-over contact Width 22,5mm Control elements Fine adjustment Setting of time range Status indication LED U/t: Supply voltage LED R: Relay status

More information

Protection relay with full PLC function

Protection relay with full PLC function S U B S T A T I O N S Protecton relay wth full PLC functon SEPCOS-NG s a hgh-tech equpment that satsfes the most demandng safety requrements applcable to DC electrcal power transmsson networks. SEPCOS-NG

More information

PRIMERGY ECONEL 30. Operating manual. Introduction. Important notes. Preparing for use. Operation. Troubleshooting and tips.

PRIMERGY ECONEL 30. Operating manual. Introduction. Important notes. Preparing for use. Operation. Troubleshooting and tips. Introducton Important notes PRIMERGY ECONEL 30 Preparng for use Operaton Operatng manual Troubleshootng and tps System expansons Techncal data Index November 2002 edton Mcrosoft, MS, MS-DOS, Wndows, and

More information

EICON Remote Control User s Guide

EICON Remote Control User s Guide EICON Remote Control User s Gude Installaton of the Wrng Harness (for MRX-12 through MRX-48) 1. Verfy that the host system wrng s n good condton and that there are no shorted solenods, relays, or feld

More information

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0 monitoring in conductive liquids 4 probe inputs for level monitoring Multifunction Adjustable sensor voltage Supply voltage 24-240V AC/DC Protective separation of measuring circuit 3 normally open contacts

More information

Room temperature controller with LC-display Codes: EK-EP2-TP-... EK-EQ2-TP-... (with R.H. sensor)

Room temperature controller with LC-display Codes: EK-EP2-TP-... EK-EQ2-TP-... (with R.H. sensor) Code LED colors Accessores Room temperature controller wth LC-dsplay Codes: EK-EP2-TP-... EK-EQ2-TP-... (wth R.H. sensor) EK-EP2-TP EK-EP2-TP-RW EK-EQ2-TP EK-EQ2-TP-RW blue / green whte / red blue / green

More information

L Series Miniature Slide Switches

L Series Miniature Slide Switches Features/Benefits Positive detent Enclosed housing Maintained and momentary functions PC and panel mounting RoHS compliant Typical Applications Communications equipment Lighting devices Models Available

More information

Bild in der Größe 215x70 mm einfügen. COMAND Operator's Manual

Bild in der Größe 215x70 mm einfügen. COMAND Operator's Manual Bld n der Größe 215x70 mm enfügen COMAND Operator's Manual Welcome to COMAND! Please make yourself famlar wth your COMAND control unt and read the nstructons n ths manual before operatng the COMAND system.

More information

userguide Intrinsically safe pager, type APG7

userguide Intrinsically safe pager, type APG7 usergude Intrnscally safe pager, type APG7 1 APG7 INTRINSICALLY SAFE PAGER LIMITATIONS OF USE Ths page contans BASEEFA related. No alteratons are permtted wthout reference to the BASEEFA lason offcer THE

More information

Product documentation. Issue:

Product documentation. Issue: Product documentaton Issue: 02.05.2017 Table of Contents Product documentaton 1 enet SMART HOME system... 5 1.1 System requrements... 5 1.2 Commssonng va... 5 1.3 Operaton va enet SMART HOME app... 7 2

More information

LCD Digital Microscope

LCD Digital Microscope Operatng Instructons LCD Dgtal Mcroscope 2 Contents Contents Safety nstructons 3 System requrements 4 Package contents 4 Devce vew and keypad 5 Startng up 7 Turnng on/off 9 Image capturng 9 Recordng vdeos

More information

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA 4 time ranges 4 transition times Supply voltage 12-240V AC/DC 2 normally open contacts Width 22,5 mm Control elements Fine adjustment star contactor Setting of time range star contactor Transit time Status

More information

Modular. Robust. Flexible. SWS Quick-change system

Modular. Robust. Flexible. SWS Quick-change system Modular. Robust. Flexble. SWS Quck-change system Pneumatc tool changng system wth patented lockng system. Feld of Applcaton C an be used wherever short changeover tmes between a handlng devce and a tool

More information

6.854 Advanced Algorithms Petar Maymounkov Problem Set 11 (November 23, 2005) With: Benjamin Rossman, Oren Weimann, and Pouya Kheradpour

6.854 Advanced Algorithms Petar Maymounkov Problem Set 11 (November 23, 2005) With: Benjamin Rossman, Oren Weimann, and Pouya Kheradpour 6.854 Advanced Algorthms Petar Maymounkov Problem Set 11 (November 23, 2005) Wth: Benjamn Rossman, Oren Wemann, and Pouya Kheradpour Problem 1. We reduce vertex cover to MAX-SAT wth weghts, such that the

More information

ST70 Instruments. Operating Guide. Welcome. This Operating Guide. Contents

ST70 Instruments. Operating Guide. Welcome. This Operating Guide. Contents ST70 Instruments Operatng Gude Welcome Congratulatons on havng chosen a Raymarne ST70 nstrument. Ths gves you easy access to the mportant nformaton you need to make your boatng experence both safe and

More information

mquest Quickstart Version 11.0

mquest Quickstart Version 11.0 mquest Quckstart Verson 11.0 cluetec GmbH Emmy-Noether-Straße 17 76131 Karlsruhe Germany www.cluetec.de www.mquest.nfo cluetec GmbH Karlsruhe, 2016 Document verson 5 27.04.2016 16:59 > Propretary notce

More information

Avaya Scopia XT Meeting Center

Avaya Scopia XT Meeting Center Avaya Scopa XT Meetng Center Quck Setup Gude Sngle Montor Dual Montor Package Content: Cart Components 3x/4x IEC320 Power Cords Internatonal (4xIEC) Outlet Strp Avaya Scopa XT Meetng Center Quck Setup

More information

Cisco TelePresence MCU 4200 Series

Cisco TelePresence MCU 4200 Series Csco TelePresence MCU 4200 Seres Gettng started 61-0002-08 Contents General nformaton... 3 About the Csco TelePresence MCU 4200 Seres... 3 Package contents... 3 Port and LED locaton... 3 LED behavor...

More information

Bild in der Größe 215x70 mm einfügen. COMAND Operator's Manual

Bild in der Größe 215x70 mm einfügen. COMAND Operator's Manual Bld n der Größe 215x70 mm enfügen COMAND Operator's Manual Welcome to COMAND! Please make yourself famlar wth your COMAND control unt and read the nstructons n ths manual before operatng the COMAND system.

More information

Protection and control relays

Protection and control relays S U B S T A T I O N S Protecton and control relays The SEPCOS PRO range s a hgh-tech generaton of protecton and control relay that satsfes the most demandng safety requrements applcable to DC electrcal

More information

Bild in der Größe 215x70 mm einfügen

Bild in der Größe 215x70 mm einfügen Order No. 6515 6709 13 Part No. 219 584 77 81 USA Edton A 2006 COMAND Operator's Manual 211/219 Bld n der Größe 215x70 mm enfügen COMAND Operator's Manual Welcome to COMAND! Please make yourself famlar

More information

MRKOMNO. kéï=~ë=çñw= pfabufp=ud. aáöáí~ä=o~çáçöê~éüó. nìáåâ=êéñéêéååé=öìáçé==== båöäáëü

MRKOMNO. kéï=~ë=çñw= pfabufp=ud. aáöáí~ä=o~çáçöê~éüó. nìáåâ=êéñéêéååé=öìáçé==== båöäáëü kéï=~ë=çñw= MRKOMNO pfabufp=ud aáöáí~ä=o~çáçöê~éüó nìáåâ=êéñéêéååé=öìáçé==== båöäáëü 0123 Ths product bears the CE markng n accordance wth the provsons of the Councl Drectve 93/42/EEC of June 14, 1993

More information

Digital Control Panel 240V AC Swing Gates Model : DCP 242 REMOTE TIMER PROGRAM FUNCTION FORCE. Jumpers. Photo Sensor LED

Digital Control Panel 240V AC Swing Gates Model : DCP 242 REMOTE TIMER PROGRAM FUNCTION FORCE. Jumpers. Photo Sensor LED DGTAL COMPUTERZED CONTROL PANEL for 240V ac SWNG GATE MOTORS Model: DCP-242V1 The DCP-242V1 is a universal Control Panel (CP) that can replace any 240V AC control panel for swing gates. t is very simple

More information

Virtual Memory. Background. No. 10. Virtual Memory: concept. Logical Memory Space (review) Demand Paging(1) Virtual Memory

Virtual Memory. Background. No. 10. Virtual Memory: concept. Logical Memory Space (review) Demand Paging(1) Virtual Memory Background EECS. Operatng System Fundamentals No. Vrtual Memory Prof. Hu Jang Department of Electrcal Engneerng and Computer Scence, York Unversty Memory-management methods normally requres the entre process

More information

g700-p planetary gearbox

g700-p planetary gearbox Gearboxes g0-p planetary gearbox to 0 Nm Contents General nformaton Lst of abbrevatons nformaton Equpment The gearbox kt Functons and features Permssble radal and axal forces at output Backlash and torsonal

More information

Life Tables (Times) Summary. Sample StatFolio: lifetable times.sgp

Life Tables (Times) Summary. Sample StatFolio: lifetable times.sgp Lfe Tables (Tmes) Summary... 1 Data Input... 2 Analyss Summary... 3 Survval Functon... 5 Log Survval Functon... 6 Cumulatve Hazard Functon... 7 Percentles... 7 Group Comparsons... 8 Summary The Lfe Tables

More information

Circuit Analysis I (ENGR 2405) Chapter 3 Method of Analysis Nodal(KCL) and Mesh(KVL)

Circuit Analysis I (ENGR 2405) Chapter 3 Method of Analysis Nodal(KCL) and Mesh(KVL) Crcut Analyss I (ENG 405) Chapter Method of Analyss Nodal(KCL) and Mesh(KVL) Nodal Analyss If nstead of focusng on the oltages of the crcut elements, one looks at the oltages at the nodes of the crcut,

More information

Zwick. Materials testing I 8 ~ I J S / KAlnhalt / V4.7

Zwick. Materials testing I 8 ~ I J S / KAlnhalt / V4.7 Zwck Materals testng Copyrght (C) 1995-2002 Zwck GmbH & Co August-Nagel-StraBe 11, Ulm, Deutschland Telefon: +49 1 02 25 Telefax: +49 1 02 00 Zwck m nternet: http://wn.zwck.com und http://www.zwck.de EMal:

More information

Modular. Robust. Flexible. SWS Quick-change system

Modular. Robust. Flexible. SWS Quick-change system SWS Modular. Robust. Flexble. SWS Quck-change system Pneumatc tool changng system wth patented lockng system. Feld of Applcaton C an be used wherever short changeover tmes between a handlng devce and a

More information

SW1D Manual for Installation, Use and Maintenance

SW1D Manual for Installation, Use and Maintenance The clever drve MAN.HESWD SWD Manual for Installaton, Use and Mantenance SWD080-00 SWD080 B-00 SWD -x0 SWD -0 Manual_SWD GB Release.9 Buld 00 Page - 7 IMPORTANT Ths document s regstered by EVER and may

More information

02/11/2015

02/11/2015 DIN Rail Mount 22.5 mm ETM2 Part number 84874023 Version ETM : Controls temperature of machines using built-in PTC probes Line break or probe short-circuit detection Version ETM2 / ETM22 : Fault latching

More information

Application Specification Miniature Spring Socket Contacts 03 MAY 11 Rev C

Application Specification Miniature Spring Socket Contacts 03 MAY 11 Rev C Applcaton Specfcaton Mnature Sprng 114-13152 Socket Contacts 03 MAY 11 Rev C All numercal values are n metrc unts [wth U.S. customary unts n brackets]. Dmensons are n mllmeters [and nches]. Unless otherwse

More information

VideoJet X10 SN Network Video Server. Installation and Operating Manual

VideoJet X10 SN Network Video Server. Installation and Operating Manual VdeoJet X10 SN Network Vdeo Server en Installaton and Operatng Manual VdeoJet X10 SN VdeoJet X10 SN Table of Contents en 3 Table of Contents 1 Preface 7 1.1 About ths Manual 7 1.2 Conventons n ths Manual

More information

Bild in der Größe 215x70 mm einfügen. COMAND Operator s Manual

Bild in der Größe 215x70 mm einfügen. COMAND Operator s Manual Bld n der Größe 215x70 mm enfügen COMAND Operator s Manual Welcome to COMAND! Please make yourself famlar wth your COMAND control unt and read the nstructons n ths manual before operatng the COMAND system.

More information

Touch & See Control and visualization unit

Touch & See Control and visualization unit Code * Materal Package Dmens. [mm] EK-FOQ-GAx EK-FOQ-GBx plastc metal pcs. 86 x 86 Touch & See Control and vsualzaton unt Code: EK-EC-TP-... S TP Datasheet STEKECTP_EN KNX devce for swtchng, controllng

More information

Installation Instructions. METRAwin Version 8/ Calibration Software

Installation Instructions. METRAwin Version 8/ Calibration Software Installaton Instructons METRAwn 90 Calbraton Software 3-349-717-15 Verson 8/05.13 Copyrght Copyrght 2003-2013 GMC-I Messtechnk GmbH. All rghts reserved. These nstallaton nstructons, as well as the software

More information

Bus Capable. Flexible. High Performance Density. PG Universal Gripper

Bus Capable. Flexible. High Performance Density. PG Universal Gripper PG Bus Capable. Flexble. Hgh Performance Densty. PG Unversal Grpper Servo-electrc 2-fnger parallel grpper wth hghly precse grppng force control and long stroke Feld of Applcaton A ll-purpose, ultra-flexble

More information

A mathematical programming approach to the analysis, design and scheduling of offshore oilfields

A mathematical programming approach to the analysis, design and scheduling of offshore oilfields 17 th European Symposum on Computer Aded Process Engneerng ESCAPE17 V. Plesu and P.S. Agach (Edtors) 2007 Elsever B.V. All rghts reserved. 1 A mathematcal programmng approach to the analyss, desgn and

More information

Zelio Control-modular measurement and control relays 1

Zelio Control-modular measurement and control relays 1 Presentation, description 1 106439 RM35 TM111MW Presentation Motor temperature measurement and 50MW and RM35 TM250MW monitor the following, on 3-phase supplies: correct sequencing of phases L1, L2 and

More information

Jan 2017, REV T

Jan 2017, REV T Modular Plug Hand Tools (Premum Grade) 231652-[ ] Instructon Sheet 408-9767 Jan 2017, REV T PROPER USE GUIDELINES Cumulatve Trauma Dsorders can result from the prolonged use of manually powered hand tools.

More information

THE HEAT CONTROLLER RADIATOR THERMOSTAT FGT-001

THE HEAT CONTROLLER RADIATOR THERMOSTAT FGT-001 OPERATING MANUAL EN THE HEAT CONTROLLER RADIATOR THERMOSTAT FGT-001 CONTENTS #1: Descrpton and features 3 #2: Basc actvaton 4 #3: Addng to Z-Wave network 5 #4: Removng the devce 6 #5: Controllng the temperature

More information

Product Information. Miniature rotary unit PRH

Product Information. Miniature rotary unit PRH Product Informaton Mnature rotary unt PRH PRH Mnature rotary unt Precse. Compact. Bus capable. PRH unversal rotary unt servo-electrc mnature rotary unt wth angle > 360, center bore, and precson gear Feld

More information

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks INTERFACE Data Sheet 102057_en_01 Description PHOENIX CONTACT - 02/2008

More information

A Binarization Algorithm specialized on Document Images and Photos

A Binarization Algorithm specialized on Document Images and Photos A Bnarzaton Algorthm specalzed on Document mages and Photos Ergna Kavalleratou Dept. of nformaton and Communcaton Systems Engneerng Unversty of the Aegean kavalleratou@aegean.gr Abstract n ths paper, a

More information

Efficient Distributed File System (EDFS)

Efficient Distributed File System (EDFS) Effcent Dstrbuted Fle System (EDFS) (Sem-Centralzed) Debessay(Debsh) Fesehaye, Rahul Malk & Klara Naherstedt Unversty of Illnos-Urbana Champagn Contents Problem Statement, Related Work, EDFS Desgn Rate

More information

3D Virtual Eyeglass Frames Modeling from Multiple Camera Image Data Based on the GFFD Deformation Method

3D Virtual Eyeglass Frames Modeling from Multiple Camera Image Data Based on the GFFD Deformation Method NICOGRAPH Internatonal 2012, pp. 114-119 3D Vrtual Eyeglass Frames Modelng from Multple Camera Image Data Based on the GFFD Deformaton Method Norak Tamura, Somsangouane Sngthemphone and Katsuhro Ktama

More information

Beautiful & practical

Beautiful & practical Tps for purchasng your ktchen The 2 sdes of a ktchen Beautful & practcal For long-lastng joy n your new ktchen Experence shows that a ktchen wll last about 15 years or longer. However, t stll has to prove

More information

Operator's Manual EU4 / EU6 / EU8. External Unwinder. Made in Germany

Operator's Manual EU4 / EU6 / EU8. External Unwinder. Made in Germany Operator's Manual External Unwnder EU4 / EU6 / EU8 Made n Germany 2 Operator's Manual 2 for the followng products Part.-No. Descrpton Type 5946091 External Unwnder EU4 5946421 External Unwnder EU6 5945806

More information

EZM x72 DIN SIZE Programmable Timer & Counter

EZM x72 DIN SIZE Programmable Timer & Counter EZM-7750 72x72 DIN SIZE Programmable Tmer & Counter EZM-7750 72 x 72 DIN Sze Unversal Input Programmable Tmer & Counter wth Output Module System - 6 dgts Process (PV) and 6 dgts Set (SV) Value Dsplay -

More information

T3 Classic connected to IP Office

T3 Classic connected to IP Office elephony IP T Contact Centers Moblty Servces T3 Classc connected to IP Offce Benutzerhandbuch User s gude Manual de usuaro Manuel utlsateur Manuale d uso Gebrukersdocumentate Contents Contents Famlarse

More information

Product Information. Universal gripper EGL

Product Information. Universal gripper EGL Product Informaton EGL EGL Flexble. Robust. Bus capable. EGL unversal grpper Servo-electrc 2-fnger parallel grpper wth senstve grppng force control and long stroke Feld of applcaton unversally applcable,

More information

Bild in der Größe 215x70 mm einfügen. COMAND Operator s Manual

Bild in der Größe 215x70 mm einfügen. COMAND Operator s Manual Bld n der Größe 215x70 mm enfügen COMAND Operat s Manual Welcome to COMAND! Please make yourself famlar wth your COMAND control unt and read the nstructons n ths manual befe operatng the COMAND system.

More information

General Description. Types of Distribution Systems. Simple Radial. Primary Switch. Transformer

General Description. Types of Distribution Systems. Simple Radial. Primary Switch. Transformer January 0 Sheet 0 Secondary Unt Substatons Secondary Below 00 V Product Overvew General Descrpton.0- General Descrpton Defnton A secondary unt substaton s a closecoupled assembly consstng of enclosed prmary

More information

A New Design of the Vehicle Detection System for Measuring Outline Size

A New Design of the Vehicle Detection System for Measuring Outline Size 3rd Internatonal Conference on Mechatroncs and Industral Informatcs (ICMII 205) A New Desgn of the Vehcle Detecton System for Measurng Outlne Sze Zhou Xao-bo,a*,Zhu Yong,b,Zhu Janhu2,c School of Physcs

More information

Transit Networking in ATM/B-ISDN based on Service Category

Transit Networking in ATM/B-ISDN based on Service Category Transt Networkng n ATM/B-ISDN based on Servce Category Young-Tak Km Dept. of Informaton and Communcaton Engneerng, College of Engneerng, YeungNam Unv. E-mal : ytkm@ynucc.yeungnam.ac.kr ABSTRACT The ATM

More information

For Fuji. Pioneering TTL Li-ion Camera Flash. PIXAPRO LTD. 50 Popes Lane, Oldbury, West Midlands, B69 4PA. Company Registration No.

For Fuji. Pioneering TTL Li-ion Camera Flash. PIXAPRO LTD. 50 Popes Lane, Oldbury, West Midlands, B69 4PA. Company Registration No. Poneerng TT -on Camera Flash For Fuj PIXAPRO TD. 50 Popes ane, Oldbury, West Mdlands, B69 4PA INSTRUCTION MANUA Englsh Tel: 011 55 3113 Web: www.essentalphoto.co.uk E-mal: customerservce@essentalphoto.co.uk

More information

OPERATOR S MANUAL COMAND AND REAR-CABIN AUDIOVISUAL SYSTEM. Grafik in der Größe 216x79 mm in den Grafikrahmen importieren!

OPERATOR S MANUAL COMAND AND REAR-CABIN AUDIOVISUAL SYSTEM. Grafik in der Größe 216x79 mm in den Grafikrahmen importieren! OPERATOR S MANUAL COMAND AND REAR-CABIN AUDIOVISUAL SYSTEM Grafk n der Größe 216x79 mm n den Grafkrahmen mporteren! Welcome to COMAND and the rear-cabn audovsual system! Please make yourself famlar wth

More information

COMPRESSORS. Compressed Air Management System. SIGMA AIR MANAGER 4.0 Key technology for Industrie 4.0 For compressor and blower stations

COMPRESSORS. Compressed Air Management System. SIGMA AIR MANAGER 4.0 Key technology for Industrie 4.0 For compressor and blower stations Compressed Ar Management System SIGMA AIR MANAGER 4.0 Key technology for Industre 4.0 For compressor and blower statons www.kaeser.com SIGMA AIR MANAGER 4.0 Compressed ar control technology 4.0 from KAESER

More information

Dual In- Line Package (DIP)

Dual In- Line Package (DIP) Dual In- Lne Package (DIP) Applcaton Specfcaton Programmng Swtches 114-1056 (7000 and 7100 Seres) 03 MAY 11 Rev D All numercal values are n metrc unts [wth U.S. customary unts n brackets]. Dmensons are

More information

Owner s Manual Automotive Audio Player with USB 2.0 Host and with ipod USB Audio and Controls TOYOTA LEXUS SCION

Owner s Manual Automotive Audio Player with USB 2.0 Host and with ipod USB Audio and Controls TOYOTA LEXUS SCION VAIS TECHNOLOG Y www.vastech.com Owner s Manual Automotve Audo Player wth USB 2.0 Host and wth Pod USB Audo and Controls TOYOTA LEXUS SCION Copyrght (C) 2003-2012 VAIS Technology Publshed January 2, 2012

More information

PD-Series General Specifications

PD-Series General Specifications PD-Series General Specifications SmartGuard is an equipment ground fault protection device that combines hydraulic/magnetic circuit breaker and overload and short circuit protection and ground fault protection.

More information

ST70 Instrument User Reference Manual. Document reference: Date: June 2007

ST70 Instrument User Reference Manual. Document reference: Date: June 2007 ST70 Instrument User Reference Manual Document reference: 81284-1 Date: June 2007 Raymarne, SeaTalk, SeaTalk 2 and SeaTalk ng are trademarks of Raymarne plc Book contents copyrght Raymarne plc Contents

More information

Subspace clustering. Clustering. Fundamental to all clustering techniques is the choice of distance measure between data points;

Subspace clustering. Clustering. Fundamental to all clustering techniques is the choice of distance measure between data points; Subspace clusterng Clusterng Fundamental to all clusterng technques s the choce of dstance measure between data ponts; D q ( ) ( ) 2 x x = x x, j k = 1 k jk Squared Eucldean dstance Assumpton: All features

More information

A Fast Visual Tracking Algorithm Based on Circle Pixels Matching

A Fast Visual Tracking Algorithm Based on Circle Pixels Matching A Fast Vsual Trackng Algorthm Based on Crcle Pxels Matchng Zhqang Hou hou_zhq@sohu.com Chongzhao Han czhan@mal.xjtu.edu.cn Ln Zheng Abstract: A fast vsual trackng algorthm based on crcle pxels matchng

More information

Quantifying Performance Models

Quantifying Performance Models Quantfyng Performance Models Prof. Danel A. Menascé Department of Computer Scence George Mason Unversty www.cs.gmu.edu/faculty/menasce.html 1 Copyrght Notce Most of the fgures n ths set of sldes come from

More information

SMART PHOTO PRINTER USER'S GUIDE. Version V MODEL SmartD90-EV

SMART PHOTO PRINTER USER'S GUIDE. Version V MODEL SmartD90-EV SMART PHOTO PRINTER MODEL SmartD90-EV USER'S GUIDE Verson V1.5.2.0 1 TABLE OF CONTENTS Introducton Introducton 3 Bascs 4 Constructon of compostons 5 Operaton Easy Prnt Servce 8 Fun Prnt Servce 10 Sharng

More information

MANUAL OF OPERATION TEXT DISPLAY LCA 245 PRODUCT GROUP LCA TECHNICAL MANUAL VERSION 06/ by SYSTEME LAUER GMBH 7440 NÜRTINGEN /8091

MANUAL OF OPERATION TEXT DISPLAY LCA 245 PRODUCT GROUP LCA TECHNICAL MANUAL VERSION 06/ by SYSTEME LAUER GMBH 7440 NÜRTINGEN /8091 TEXT DISPLAY TECHNICAL MANUAL PRODUCT GROUP LCA 1988 by SYSTEME LAUER GMBH 7440 NÜRTINGEN 1 072/8091 VERSION 06/03.93 TEXT DISPLAY THE TEXT DISPLAY CAN... PRODUCT GROUP LCA The text dsplay ncorporates

More information